trigger

The trigger commands module.

These commands are used in the following models: DPO4K, MDO4KB

THIS FILE IS AUTO-GENERATED, IT SHOULD NOT BE MANUALLY MODIFIED.

Please report an issue if one is found.

Commands and Queries
- TRIGger FORCe
- TRIGger:A SETLevel
- TRIGger:A:BANDWidth:RF:HIGH?
- TRIGger:A:BANDWidth:RF:LOW?
- TRIGger:A:BUS {I2C|SPI|CAN|RS232C|PARallel|USB|LIN|FLEXRay|AUDio|ETHERnet|MIL1553B}
- TRIGger:A:BUS:B<x>:ARINC429A:CONDition {STARt|END|LABel|DATA|LABELANDDATA|ERRor}
- TRIGger:A:BUS:B<x>:ARINC429A:CONDition?
- TRIGger:A:BUS:B<x>:ARINC429A:ERRTYPE {ANY|GAP|WORD|PARity}
- TRIGger:A:BUS:B<x>:ARINC429A:ERRTYPE?
- TRIGger:A:BUS:B<x>:ARINC429A:LABel:HIVALue <QString>
- TRIGger:A:BUS:B<x>:ARINC429A:LABel:HIVALue?
- TRIGger:A:BUS:B<x>:ARINC429A:LABel:QUALifier {LESSthan|MOREthan|Equal|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:ARINC429A:LABel:QUALifier?
- TRIGger:A:BUS:B<x>:ARINC429A:LABel:VALue <QString>
- TRIGger:A:BUS:B<x>:ARINC429A:LABel:VALue?
- TRIGger:A:BUS:B<x>:ARINC429A:SDI <QString>
- TRIGger:A:BUS:B<x>:ARINC429A:SDI?
- TRIGger:A:BUS:B<x>:ARINC429A:SSM <QString>
- TRIGger:A:BUS:B<x>:ARINC429A:SSM?
- TRIGger:A:BUS:B<x>:AUDio:CONDition {SOF|DATA}
- TRIGger:A:BUS:B<x>:AUDio:CONDition?
- TRIGger:A:BUS:B<x>:AUDio:DATa:HIVALue <String>
- TRIGger:A:BUS:B<x>:AUDio:DATa:HIVALue?
- TRIGger:A:BUS:B<x>:AUDio:DATa:OFFSet <NR1>
- TRIGger:A:BUS:B<x>:AUDio:DATa:OFFSet?
- TRIGger:A:BUS:B<x>:AUDio:DATa:QUALifier {LESSthan|MOREthan|EQual|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:AUDio:DATa:QUALifier?
- TRIGger:A:BUS:B<x>:AUDio:DATa:VALue <String>
- TRIGger:A:BUS:B<x>:AUDio:DATa:VALue?
- TRIGger:A:BUS:B<x>:AUDio:DATa:WORD {EITher|LEFt|RIGht}
- TRIGger:A:BUS:B<x>:AUDio:DATa:WORD?
- TRIGger:A:BUS:B<x>:CAN:ADDRess:MODe {STandard|EXTENDed}
- TRIGger:A:BUS:B<x>:CAN:ADDRess:MODe?
- TRIGger:A:BUS:B<x>:CAN:ADDRess:VALue <QString>
- TRIGger:A:BUS:B<x>:CAN:ADDRess:VALue?
- TRIGger:A:BUS:B<x>:CAN:CONDition {SOF|FRAMEtype|IDentifier|DATA|IDANDDATA|EOF|ACKMISS|ERROR|FORMERRor|ANYERRor|FDBRS|FDESI}
- TRIGger:A:BUS:B<x>:CAN:CONDition?
- TRIGger:A:BUS:B<x>:CAN:DATa:DIRection {READ|WRITE|NOCARE}
- TRIGger:A:BUS:B<x>:CAN:DATa:DIRection?
- TRIGger:A:BUS:B<x>:CAN:DATa:OFFSet <NR1>
- TRIGger:A:BUS:B<x>:CAN:DATa:OFFSet?
- TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier {LESSthan|Than|EQual|UNEQual|LESSEQual|EQual}
- TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier?
- TRIGger:A:BUS:B<x>:CAN:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:CAN:DATa:SIZe?
- TRIGger:A:BUS:B<x>:CAN:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:CAN:DATa:VALue?
- TRIGger:A:BUS:B<x>:CAN:FD:BRSBIT {ZERo|OFF|0|ONE|ON|1|NOCARE|X|x}
- TRIGger:A:BUS:B<x>:CAN:FD:BRSBIT?
- TRIGger:A:BUS:B<x>:CAN:FD:ESIBIT {ZERo|OFF|0|ONE|ON|1|NOCARE|X|x}
- TRIGger:A:BUS:B<x>:CAN:FD:ESIBIT?
- TRIGger:A:BUS:B<x>:CAN:FRAMEtype {DATA|REMote|ERRor|OVERLoad}
- TRIGger:A:BUS:B<x>:CAN:FRAMEtype?
- TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe {STandard|EXTENDed}
- TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe?
- TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue <QString>
- TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue?
- TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:DESTinationport:VALue <QString>
- TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:DESTinationport:VALue?
- TRIGger:A:BUS:B<x>:FLEXray:CONDition {SOF|FRAMEType|IDentifier|CYCLEcount|HEADer|DATA|IDANDDATA|EOF|ERROR}
- TRIGger:A:BUS:B<x>:FLEXray:CONDition?
- TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:HIVALue <QString>
- TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:HIVALue?
- TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:QUALifier {LESSthan|MOREthan|EQual|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:QUALifier?
- TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:VALue <QString>
- TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:VALue?
- TRIGger:A:BUS:B<x>:FLEXray:DATa:HIVALue <QString>
- TRIGger:A:BUS:B<x>:FLEXray:DATa:HIVALue?
- TRIGger:A:BUS:B<x>:FLEXray:DATa:OFFSet <NR1>
- TRIGger:A:BUS:B<x>:FLEXray:DATa:OFFSet?
- TRIGger:A:BUS:B<x>:FLEXray:DATa:QUALifier {LESSthan|MOREthan|EQual|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:FLEXray:DATa:QUALifier?
- TRIGger:A:BUS:B<x>:FLEXray:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:FLEXray:DATa:SIZe?
- TRIGger:A:BUS:B<x>:FLEXray:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:FLEXray:DATa:VALue?
- TRIGger:A:BUS:B<x>:FLEXray:EOFTYPE {STATic|DYNAMic|ANY}
- TRIGger:A:BUS:B<x>:FLEXray:EOFTYPE?
- TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE {CRCHeader|CRCTrailer|SYNCFrame|STARTupnosync|NULLFRStatic|NULLFRDynamic}
- TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE?
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIVALue <QString>
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIVALue?
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:QUALifier {LESSthan|MOREthan|EQual|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:QUALifier?
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VALue <QString>
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VALue?
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEType {NORMal|PAYLoad|NULL|SYNC|STARTup}
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEType?
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:CRC <QString>
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:CRC?
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:CYCLEcount <QString>
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:CYCLEcount?
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:FRAMEID <QString>
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:FRAMEID?
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:INDBits <QString>
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:INDBits?
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:PAYLength <QString>
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:PAYLength?
- TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe {ADDR7|ADDR10}
- TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe?
- TRIGger:A:BUS:B<x>:I2C:ADDRess:TYPe {GENeralcall|STARtbyte|HSmode|EEPROM|USER}
- TRIGger:A:BUS:B<x>:I2C:ADDRess:TYPe?
- TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue <QString>
- TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue?
- TRIGger:A:BUS:B<x>:I2C:CONDition {STARt|STOP|REPEATstart|ACKMISS|ADDRess|DATA|ADDRANDDATA}
- TRIGger:A:BUS:B<x>:I2C:CONDition?
- TRIGger:A:BUS:B<x>:I2C:DATa:DIRection {READ|WRITE|NOCARE}
- TRIGger:A:BUS:B<x>:I2C:DATa:DIRection?
- TRIGger:A:BUS:B<x>:I2C:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:I2C:DATa:SIZe?
- TRIGger:A:BUS:B<x>:I2C:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:I2C:DATa:VALue?
- TRIGger:A:BUS:B<x>:LIN:CONDition {SYNCField|IDentifier|DATA|IDANDDATA|WAKEup|SLEEP|ERROR}
- TRIGger:A:BUS:B<x>:LIN:CONDition?
- TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue <QString>
- TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue?
- TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier {LESSthan|MOREthan|EQual|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier?
- TRIGger:A:BUS:B<x>:LIN:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:LIN:DATa:SIZe?
- TRIGger:A:BUS:B<x>:LIN:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:LIN:DATa:VALue?
- TRIGger:A:BUS:B<x>:LIN:ERRTYPE {SYNC|PARity|CHecksum|HEADertime|RESPtime|FRAMetime}
- TRIGger:A:BUS:B<x>:LIN:ERRTYPE?
- TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue <QString>
- TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue?
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:HIVALue <QString>
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:HIVALue?
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:QUALifier {LESSthan|MOREthan|EQual|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:QUALifier?
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:VALue <QString>
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:VALue?
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:COUNt <QString>
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:COUNt?
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:PARity {0|1|X|ZERo|ONE|NOCARE|OFF|ON}
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:PARity?
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:SUBADdress <QString>
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:SUBADdress?
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:TRBit {RX|TX|X}
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:TRBit?
- TRIGger:A:BUS:B<x>:MIL1553B:CONDition {SYNC|COMMAND|STATus|DATA|TIMe|ERRor}
- TRIGger:A:BUS:B<x>:MIL1553B:CONDition?
- TRIGger:A:BUS:B<x>:MIL1553B:DATa:PARity {0|1|X|ZERo|ONE|NOCARE|OFF|ON}
- TRIGger:A:BUS:B<x>:MIL1553B:DATa:PARity?
- TRIGger:A:BUS:B<x>:MIL1553B:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:MIL1553B:DATa:VALue?
- TRIGger:A:BUS:B<x>:MIL1553B:ERRTYPE {PARity|SYNC|MANCHester|DATA}
- TRIGger:A:BUS:B<x>:MIL1553B:ERRTYPE?
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:HIVALue <QString>
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:HIVALue?
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:QUALifier {LESSthan|MOREthan|EQual|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:QUALifier?
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:VALue <QString>
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:VALue?
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:BCR {0|1|X|ZERo|ONE|NOCARE|OFF|ON}
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:BCR?
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:BUSY {0|1|X|ZERo|ONE|NOCARE|OFF|ON}
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:BUSY?
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:DBCA {0|1|X|ZERo|ONE|NOCARE|OFF|ON}
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:DBCA?
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:INSTR {0|1|X|ZERo|ONE|NOCARE|OFF|ON}
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:INSTR?
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:ME {0|1|X|ZERo|ONE|NOCARE|OFF|ON}
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:ME?
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:SRQ {0|1|X|ZERo|ONE|NOCARE|OFF|ON}
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:SRQ?
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:SUBSF {0|1|X|ZERo|ONE|NOCARE|OFF|ON}
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:SUBSF?
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:TF {0|1|X|ZERo|ONE|NOCARE|OFF|ON}
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:TF?
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:PARity {0|1|X|ZERo|ONE|NOCARE|OFF|ON}
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:PARity?
- TRIGger:A:BUS:B<x>:MIL1553B:TIMe:LESSLimit <NR3>
- TRIGger:A:BUS:B<x>:MIL1553B:TIMe:LESSLimit?
- TRIGger:A:BUS:B<x>:MIL1553B:TIMe:MORELimit <NR3>
- TRIGger:A:BUS:B<x>:MIL1553B:TIMe:MORELimit?
- TRIGger:A:BUS:B<x>:MIL1553B:TIMe:QUALifier {LESSthan|MOREthan|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:MIL1553B:TIMe:QUALifier?
- TRIGger:A:BUS:B<x>:PARallel:VALue <QString>
- TRIGger:A:BUS:B<x>:PARallel:VALue?
- TRIGger:A:BUS:B<x>:RS232C:CONDition {RXSTArt|RXDATA|RXENDPacket|TXSTArt|TXDATA|TXENDPacket}
- TRIGger:A:BUS:B<x>:RS232C:CONDition?
- TRIGger:A:BUS:B<x>:RS232C:RX:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:RS232C:RX:DATa:SIZe?
- TRIGger:A:BUS:B<x>:RS232C:RX:DATa:VALue
- TRIGger:A:BUS:B<x>:RS232C:RX:DATa:VALue?
- TRIGger:A:BUS:B<x>:RS232C:TX:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:RS232C:TX:DATa:SIZe?
- TRIGger:A:BUS:B<x>:RS232C:TX:DATa:VALue
- TRIGger:A:BUS:B<x>:RS232C:TX:DATa:VALue?
- TRIGger:A:BUS:B<x>:SPI:CONDition {SS|STARTofframe|MISO|MOSI|MISOMOSI}
- TRIGger:A:BUS:B<x>:SPI:CONDition?
- TRIGger:A:BUS:B<x>:SPI:DATa:IN:VALue <QString>
- TRIGger:A:BUS:B<x>:SPI:DATa:IN:VALue?
- TRIGger:A:BUS:B<x>:SPI:DATa:MISO:VALue <QString>
- TRIGger:A:BUS:B<x>:SPI:DATa:MISO:VALue?
- TRIGger:A:BUS:B<x>:SPI:DATa:MOSI:VALue <QString>
- TRIGger:A:BUS:B<x>:SPI:DATa:MOSI:VALue?
- TRIGger:A:BUS:B<x>:SPI:DATa:OUT:VALue <QString>
- TRIGger:A:BUS:B<x>:SPI:DATa:OUT:VALue?
- TRIGger:A:BUS:B<x>:SPI:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:SPI:DATa:SIZe?
- TRIGger:A:BUS:B<x>:USB:ADDRess:HIVALue <QString>
- TRIGger:A:BUS:B<x>:USB:ADDRess:HIVALue?
- TRIGger:A:BUS:B<x>:USB:ADDRess:VALue <Qstring>
- TRIGger:A:BUS:B<x>:USB:ADDRess:VALue?
- TRIGger:A:BUS:B<x>:USB:CONDition {SYNC|RESET|SUSPEND|RESUME|EOP|TOKENPacket|DATAPacket|HANDSHAKEPacket|SPECIALPacket|ERRor}
- TRIGger:A:BUS:B<x>:USB:CONDition?
- TRIGger:A:BUS:B<x>:USB:DATa:HIVALue <QString>
- TRIGger:A:BUS:B<x>:USB:DATa:HIVALue?
- TRIGger:A:BUS:B<x>:USB:DATa:OFFSet <NR1>
- TRIGger:A:BUS:B<x>:USB:DATa:OFFSet?
- TRIGger:A:BUS:B<x>:USB:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:USB:DATa:SIZe?
- TRIGger:A:BUS:B<x>:USB:DATa:TYPe {ANY|DATA<x>}
- TRIGger:A:BUS:B<x>:USB:DATa:TYPe?
- TRIGger:A:BUS:B<x>:USB:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:USB:DATa:VALue?
- TRIGger:A:BUS:B<x>:USB:ENDPoint:VALue <QString>
- TRIGger:A:BUS:B<x>:USB:ENDPoint:VALue?
- TRIGger:A:BUS:B<x>:USB:ERRTYPE {PID|CRC5|CRC16|BITSTUFFing}
- TRIGger:A:BUS:B<x>:USB:ERRTYPE?
- TRIGger:A:BUS:B<x>:USB:HANDSHAKEType {ANY|NAK|ACK|STALL}
- TRIGger:A:BUS:B<x>:USB:HANDSHAKEType?
- TRIGger:A:BUS:B<x>:USB:QUALifier {LESSthan|MOREthan|EQual|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:USB:QUALifier?
- TRIGger:A:BUS:B<x>:USB:SOFFRAMENUMber <QString>
- TRIGger:A:BUS:B<x>:USB:SOFFRAMENUMber?
- TRIGger:A:BUS:B<x>:USB:SPECIALType {ANY|PREamble|RESERVed}
- TRIGger:A:BUS:B<x>:USB:SPECIALType?
- TRIGger:A:BUS:B<x>:USB:SPLit:ET:VALue {NOCARE|CONTRol|ISOchronous|BULK|INTERRUPT}
- TRIGger:A:BUS:B<x>:USB:SPLit:ET:VALue?
- TRIGger:A:BUS:B<x>:USB:SPLit:HUB:VALue <QString>
- TRIGger:A:BUS:B<x>:USB:SPLit:HUB:VALue?
- TRIGger:A:BUS:B<x>:USB:SPLit:PORT:VALue <QString>
- TRIGger:A:BUS:B<x>:USB:SPLit:PORT:VALue?
- TRIGger:A:BUS:B<x>:USB:SPLit:SC:VALue {NOCARE|SSPLIT|CSPLIT}
- TRIGger:A:BUS:B<x>:USB:SPLit:SC:VALue?
- TRIGger:A:BUS:B<x>:USB:SPLit:SE:VALue {NOCARE|FULLSPeed|LOWSPeed|ISOSTART|ISOMID|ISOEND|ISOALL}
- TRIGger:A:BUS:B<x>:USB:SPLit:SE:VALue?
- TRIGger:A:BUS:B<x>:USB:TOKENType {ANY|SOF|OUT|IN|SETUP}
- TRIGger:A:BUS:B<x>:USB:TOKENType?
- TRIGger:A:BUS:SOUrce {B<x>}
- TRIGger:A:BUS:SOUrce?
- TRIGger:A:BUS?
- TRIGger:A:EDGE:COUPling {AC|DC|HFRej|LFRej|NOISErej}
- TRIGger:A:EDGE:COUPling?
- TRIGger:A:EDGE:SLOpe {RISe|FALL|EITHer}
- TRIGger:A:EDGE:SLOpe?
- TRIGger:A:EDGE:SOUrce {AUX|CH<x>|D<x>|LINE|RF}
- TRIGger:A:EDGE:SOUrce?
- TRIGger:A:EDGE?
- TRIGger:A:HOLDoff:TIMe <NR3>
- TRIGger:A:HOLDoff:TIMe?
- TRIGger:A:HOLDoff?
- TRIGger:A:LEVel:AUXin {<NR3>|ECL|TTL}
- TRIGger:A:LEVel:AUXin?
- TRIGger:A:LEVel:CH<x> {<NR3>|ECL|TTL}
- TRIGger:A:LEVel:CH<x>?
- TRIGger:A:LEVel:D<x> {<NR3>|ECL|TTL}
- TRIGger:A:LEVel:D<x>?
- TRIGger:A:LOGIc:CLAss {LOGIC|SETHold}
- TRIGger:A:LOGIc:CLAss?
- TRIGger:A:LOGIc:FUNCtion {AND|NANd|NOR|OR}
- TRIGger:A:LOGIc:FUNCtion?
- TRIGger:A:LOGIc:INPut:CH<x> {HIGH|LOW|X}
- TRIGger:A:LOGIc:INPut:CH<x>?
- TRIGger:A:LOGIc:INPut:CLOCk:EDGE {FALL|RISe}
- TRIGger:A:LOGIc:INPut:CLOCk:EDGE?
- TRIGger:A:LOGIc:INPut:CLOCk:SOUrce {CH<x>|D<x>|RF|NONE}
- TRIGger:A:LOGIc:INPut:CLOCk:SOUrce?
- TRIGger:A:LOGIc:INPut:D<x> {HIGH|LOW|X}
- TRIGger:A:LOGIc:INPut:D<x>?
- TRIGger:A:LOGIc:INPut:RF {HIGH|LOW|X}
- TRIGger:A:LOGIc:INPut:RF?
- TRIGger:A:LOGIc:INPut?
- TRIGger:A:LOGIc:PATtern:DELTatime <NR3>
- TRIGger:A:LOGIc:PATtern:DELTatime?
- TRIGger:A:LOGIc:PATtern:WHEn {TRUe|FALSe|LESSthan|MOREthan|EQual|UNEQual}
- TRIGger:A:LOGIc:PATtern:WHEn?
- TRIGger:A:LOGIc:PATtern?
- TRIGger:A:LOGIc:THReshold:CH<x> {<NR3>|ECL|TTL}
- TRIGger:A:LOGIc:THReshold:CH<x>?
- TRIGger:A:LOGIc:THReshold:D<x> {<NR3>|ECL|TTL}
- TRIGger:A:LOGIc:THReshold:D<x>?
- TRIGger:A:LOGIc:THReshold:RF {<NR3>}
- TRIGger:A:LOGIc:THReshold:RF?
- TRIGger:A:LOGIc?
- TRIGger:A:LOWerthreshold:AUX {<NR3>|ECL|TTL}
- TRIGger:A:LOWerthreshold:AUX?
- TRIGger:A:LOWerthreshold:CH<x> {ECL|TTL|<NR3>}
- TRIGger:A:LOWerthreshold:CH<x>?
- TRIGger:A:LOWerthreshold:D<x> {<NR3>|ECL|TTL}
- TRIGger:A:LOWerthreshold:D<x>?
- TRIGger:A:LOWerthreshold:EXT {<NR3>|ECL|TTL}
- TRIGger:A:LOWerthreshold:EXT?
- TRIGger:A:LOWerthreshold:RF {<NR3>}
- TRIGger:A:LOWerthreshold:RF?
- TRIGger:A:MODe {AUTO|NORMal}
- TRIGger:A:MODe?
- TRIGger:A:PULSEWidth:HIGHLimit <NR3>
- TRIGger:A:PULSEWidth:HIGHLimit?
- TRIGger:A:PULSEWidth:LOWLimit <NR3>
- TRIGger:A:PULSEWidth:LOWLimit?
- TRIGger:A:PULSEWidth:POLarity {NEGative|POSitive}
- TRIGger:A:PULSEWidth:POLarity?
- TRIGger:A:PULSEWidth:SOUrce {CH<x>|LINE|AUX|D<x>|RF}
- TRIGger:A:PULSEWidth:SOUrce?
- TRIGger:A:PULSEWidth:WHEn {LESSthan|MOREthan|EQual|UNEQual|WIThin|OUTside}
- TRIGger:A:PULSEWidth:WHEn?
- TRIGger:A:PULSEWidth:WIDth <NR3>
- TRIGger:A:PULSEWidth:WIDth?
- TRIGger:A:PULse:CLAss {RUNt|WIDth|TRANsition|TIMEOut}
- TRIGger:A:PULse:CLAss?
- TRIGger:A:RISEFall:DELTatime <NR3>
- TRIGger:A:RISEFall:DELTatime?
- TRIGger:A:RISEFall:POLarity {EITher|NEGative|POSitive}
- TRIGger:A:RISEFall:POLarity?
- TRIGger:A:RISEFall:SOUrce {CH<x>}
- TRIGger:A:RISEFall:SOUrce?
- TRIGger:A:RISEFall:WHEn {SLOWer|FASTer|EQual|UNEQual}
- TRIGger:A:RISEFall:WHEn?
- TRIGger:A:RISEFall?
- TRIGger:A:RUNT:POLarity {EITher|NEGative|POSitive}
- TRIGger:A:RUNT:POLarity?
- TRIGger:A:RUNT:SOUrce {CH<x>|RF}
- TRIGger:A:RUNT:SOUrce?
- TRIGger:A:RUNT:WHEn {LESSthan|MOREthan|EQual|UNEQual|OCCURS}
- TRIGger:A:RUNT:WHEn?
- TRIGger:A:RUNT:WIDth <NR3>
- TRIGger:A:RUNT:WIDth?
- TRIGger:A:RUNT?
- TRIGger:A:SETHold:CLOCk:EDGE {FALL|RISe}
- TRIGger:A:SETHold:CLOCk:EDGE?
- TRIGger:A:SETHold:CLOCk:SOUrce {CH<x>|D<x>|AUX}
- TRIGger:A:SETHold:CLOCk:SOUrce?
- TRIGger:A:SETHold:CLOCk:THReshold {<NR3>|TTL}
- TRIGger:A:SETHold:CLOCk:THReshold?
- TRIGger:A:SETHold:CLOCk?
- TRIGger:A:SETHold:DATa:SOUrce {CH<x>|D<x>|AUX}
- TRIGger:A:SETHold:DATa:SOUrce?
- TRIGger:A:SETHold:DATa:THReshold {<NR3>|TTL}
- TRIGger:A:SETHold:DATa:THReshold?
- TRIGger:A:SETHold:DATa?
- TRIGger:A:SETHold:HOLDTime <NR3>
- TRIGger:A:SETHold:HOLDTime?
- TRIGger:A:SETHold:SETTime <NR3>
- TRIGger:A:SETHold:SETTime?
- TRIGger:A:SETHold:THReshold:CH<x> {<NR3>|ECL|TTL}
- TRIGger:A:SETHold:THReshold:CH<x>?
- TRIGger:A:SETHold:THReshold:D<x> {<NR3>|ECL|TTL}
- TRIGger:A:SETHold:THReshold:D<x>?
- TRIGger:A:SETHold?
- TRIGger:A:TIMEOut:POLarity {STAYSHigh|STAYSLow|EITher}
- TRIGger:A:TIMEOut:POLarity?
- TRIGger:A:TIMEOut:SOUrce {CH<x>|LINE|AUX|D<x>|RF}
- TRIGger:A:TIMEOut:SOUrce?
- TRIGger:A:TIMEOut:TIMe <NR3>
- TRIGger:A:TIMEOut:TIMe?
- TRIGger:A:TRANsition:DELTatime <NR3>
- TRIGger:A:TRANsition:DELTatime?
- TRIGger:A:TRANsition:POLarity {EITher|NEGative|POSitive}
- TRIGger:A:TRANsition:POLarity?
- TRIGger:A:TRANsition:SOUrce {CH<x>}
- TRIGger:A:TRANsition:SOUrce?
- TRIGger:A:TRANsition:WHEn {SLOWer|FASTer|EQual|UNEQual}
- TRIGger:A:TRANsition:WHEn?
- TRIGger:A:TRANsition?
- TRIGger:A:TYPe {EDGe|LOGIc|PULSe|BUS|VIDeo}
- TRIGger:A:TYPe?
- TRIGger:A:UPPerthreshold:CH<x> {<NR3>|ECL|TTL}
- TRIGger:A:UPPerthreshold:CH<x>?
- TRIGger:A:UPPerthreshold:RF {<NR3>}
- TRIGger:A:UPPerthreshold:RF?
- TRIGger:A:VIDeo:CUSTom:FORMat {INTERLAced|PROGressive}
- TRIGger:A:VIDeo:CUSTom:FORMat?
- TRIGger:A:VIDeo:CUSTom:LINEPeriod <NR3>
- TRIGger:A:VIDeo:CUSTom:LINEPeriod?
- TRIGger:A:VIDeo:CUSTom:SYNCInterval <NR3>
- TRIGger:A:VIDeo:CUSTom:SYNCInterval?
- TRIGger:A:VIDeo:CUSTom:TYPe {INTERLAced|PROGressive}
- TRIGger:A:VIDeo:CUSTom:TYPe?
- TRIGger:A:VIDeo:FIELD {ODD|EVEN|ALLFields|ALLLines|NUMERic}
- TRIGger:A:VIDeo:FIELD?
- TRIGger:A:VIDeo:HOLDoff:FIELD <NR3>
- TRIGger:A:VIDeo:HOLDoff:FIELD?
- TRIGger:A:VIDeo:LINE <NR1>
- TRIGger:A:VIDeo:LINE?
- TRIGger:A:VIDeo:POLarity {NEGative|POSitive}
- TRIGger:A:VIDeo:POLarity?
- TRIGger:A:VIDeo:SOUrce {CH<x>}
- TRIGger:A:VIDeo:SOUrce?
- TRIGger:A:VIDeo:STANdard {NTSc|PAL|SECAM|BILevelcustom|TRILevelcustom|HD480P60|HD576P50|HD720P30|HD720P50|HD720P60|HD875I60|HD1080P24|HD1080SF24|HD1080I50|HD1080I60|HD1080P25|HD1080P30|HD1080P50|HD1080P60}
- TRIGger:A:VIDeo:STANdard?
- TRIGger:A:VIDeo:SYNC {ODD|EVEN|ALLFields|ALLLines|NUMERic}
- TRIGger:A:VIDeo:SYNC?
- TRIGger:A:VIDeo?
- TRIGger:A?
- TRIGger:B SETLevel
- TRIGger:B:BY {EVENTS|TIMe}
- TRIGger:B:BY?
- TRIGger:B:EDGE:COUPling {DC|HFRej|LFRej|NOISErej}
- TRIGger:B:EDGE:COUPling?
- TRIGger:B:EDGE:SLOpe {RISe|FALL}
- TRIGger:B:EDGE:SLOpe?
- TRIGger:B:EDGE:SOUrce {CH<x>|AUX|LINE|RF}
- TRIGger:B:EDGE:SOUrce?
- TRIGger:B:EDGE?
- TRIGger:B:EVENTS:COUNt <NR1>
- TRIGger:B:EVENTS:COUNt?
- TRIGger:B:EVENTS?
- TRIGger:B:LEVel {TTL|<NR3>}
- TRIGger:B:LEVel:CH<x> {ECL|TTL|<NR3>}
- TRIGger:B:LEVel:CH<x>?
- TRIGger:B:LEVel:D<x> {ECL|TTL|<NR3>}
- TRIGger:B:LEVel:D<x>?
- TRIGger:B:LEVel?
- TRIGger:B:LOWerthreshold:CH<x> {ECL|TTL|<NR3>}
- TRIGger:B:LOWerthreshold:CH<x>?
- TRIGger:B:LOWerthreshold:D<x> {<NR3>|ECL|TTL}
- TRIGger:B:LOWerthreshold:D<x>?
- TRIGger:B:STATE {ON|OFF|<NR1>}
- TRIGger:B:STATE?
- TRIGger:B:TIMe <NR3>
- TRIGger:B:TIMe?
- TRIGger:B:TYPe EDGE
- TRIGger:B:TYPe?
- TRIGger:B?
- TRIGger:EXTernal:PRObe <NR3>
- TRIGger:EXTernal:PRObe?
- TRIGger:EXTernal:YUNIts?
- TRIGger:EXTernal?
- TRIGger:FREQuency?
- TRIGger:STATE?
- TRIGger?

Trigger

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger command.

Description
  • This command forces a trigger event to occur. The query returns the current trigger parameters for the instrument.
Usage
  • Using the .query() method will send the TRIGger? query.
  • Using the .verify(value) method will send the TRIGger? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger value command.
SCPI Syntax
- TRIGger FORCe
- TRIGger?
Info
  • FORCe creates a trigger event. If TRIGger:STATE is set to READy, the acquisition will complete. Otherwise, this command will be ignored. This is equivalent to pressing the Force button on the front panel.
Properties
  • .a: The TRIGger:A command.
  • .b: The TRIGger:B command.
  • .external: The TRIGger:EXTernal command.
  • .frequency: The TRIGger:FREQuency command.
  • .state: The TRIGger:STATE command.

a property

Return the TRIGger:A command.

Description
  • This command sets the A trigger level automatically to 50% of the range of the minimum and maximum values of the trigger input signal. The query returns current trigger parameters. The trigger level is the voltage threshold through which the trigger source signal must pass to generate a trigger event. This command is equivalent to pushing the LEVEL knob on the front panel.
Usage
  • Using the .query() method will send the TRIGger:A? query.
  • Using the .verify(value) method will send the TRIGger:A? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A value command.
SCPI Syntax
- TRIGger:A SETLevel
- TRIGger:A?
Info
  • SETLevel sets the trigger level to 50% of the range of the minimum and maximum values of the trigger input signal.
Sub-properties
  • .bandwidth: The TRIGger:A:BANDWidth command tree.
  • .bus: The TRIGger:A:BUS command.
  • .edge: The TRIGger:A:EDGE command.
  • .holdoff: The TRIGger:A:HOLDoff command.
  • .level: The TRIGger:A:LEVel command tree.
  • .logic: The TRIGger:A:LOGIc command.
  • .lowerthreshold: The TRIGger:A:LOWerthreshold command tree.
  • .mode: The TRIGger:A:MODe command.
  • .pulsewidth: The TRIGger:A:PULSEWidth command tree.
  • .pulse: The TRIGger:A:PULse command tree.
  • .runt: The TRIGger:A:RUNT command.
  • .sethold: The TRIGger:A:SETHold command.
  • .timeout: The TRIGger:A:TIMEOut command tree.
  • .type: The TRIGger:A:TYPe command.
  • .upperthreshold: The TRIGger:A:UPPerthreshold command tree.
  • .video: The TRIGger:A:VIDeo command.
  • .transition: The TRIGger:A:TRANsition command.
  • .risefall: The TRIGger:A:RISEFall command.

b property

Return the TRIGger:B command.

Description
  • Sets the B trigger level to 50% of minimum and maximum. The query form of this command returns the B trigger parameters. This command is similar to selecting B Event (Delayed) Trigger Setup from the Trigger menu and then viewing the current setups.
Usage
  • Using the .query() method will send the TRIGger:B? query.
  • Using the .verify(value) method will send the TRIGger:B? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:B value command.
SCPI Syntax
- TRIGger:B SETLevel
- TRIGger:B?
Info
  • SETLevel sets the B trigger level to 50% of MIN and MAX.
Sub-properties
  • .by: The TRIGger:B:BY command.
  • .edge: The TRIGger:B:EDGE command.
  • .events: The TRIGger:B:EVENTS command.
  • .level: The TRIGger:B:LEVel command.
  • .lowerthreshold: The TRIGger:B:LOWerthreshold command tree.
  • .state: The TRIGger:B:STATE command.
  • .time: The TRIGger:B:TIMe command.
  • .type: The TRIGger:B:TYPe command.

external property

external: TriggerExternal

Return the TRIGger:EXTernal command.

Description
  • Returns all external trigger-related parameters for the probe attached to the Aux Input connector.
Usage
  • Using the .query() method will send the TRIGger:EXTernal? query.
  • Using the .verify(value) method will send the TRIGger:EXTernal? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:EXTernal?
Sub-properties
  • .probe: The TRIGger:EXTernal:PRObe command.
  • .yunits: The TRIGger:EXTernal:YUNIts command.

frequency property

frequency: TriggerFrequency

Return the TRIGger:FREQuency command.

Description
  • Returns the trigger frequency in hertz if available. If the trigger frequency is not currently available, the IEEE Not A Number (NaN = 99.10E+36) value is returned. The maximum precision of the returned frequency is 12 digits. Use the DISPLAY:TRIGFREQUENCY command to enable/disable the calculation of the trigger frequency.
Usage
  • Using the .query() method will send the TRIGger:FREQuency? query.
  • Using the .verify(value) method will send the TRIGger:FREQuency? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:FREQuency?

state property

state: TriggerState

Return the TRIGger:STATE command.

Description
  • This query-only command returns the current state of the triggering system.
Usage
  • Using the .query() method will send the TRIGger:STATE? query.
  • Using the .verify(value) method will send the TRIGger:STATE? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:STATE?

TriggerA

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A command.

Description
  • This command sets the A trigger level automatically to 50% of the range of the minimum and maximum values of the trigger input signal. The query returns current trigger parameters. The trigger level is the voltage threshold through which the trigger source signal must pass to generate a trigger event. This command is equivalent to pushing the LEVEL knob on the front panel.
Usage
  • Using the .query() method will send the TRIGger:A? query.
  • Using the .verify(value) method will send the TRIGger:A? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A value command.
SCPI Syntax
- TRIGger:A SETLevel
- TRIGger:A?
Info
  • SETLevel sets the trigger level to 50% of the range of the minimum and maximum values of the trigger input signal.
Properties
  • .bandwidth: The TRIGger:A:BANDWidth command tree.
  • .bus: The TRIGger:A:BUS command.
  • .edge: The TRIGger:A:EDGE command.
  • .holdoff: The TRIGger:A:HOLDoff command.
  • .level: The TRIGger:A:LEVel command tree.
  • .logic: The TRIGger:A:LOGIc command.
  • .lowerthreshold: The TRIGger:A:LOWerthreshold command tree.
  • .mode: The TRIGger:A:MODe command.
  • .pulsewidth: The TRIGger:A:PULSEWidth command tree.
  • .pulse: The TRIGger:A:PULse command tree.
  • .runt: The TRIGger:A:RUNT command.
  • .sethold: The TRIGger:A:SETHold command.
  • .timeout: The TRIGger:A:TIMEOut command tree.
  • .type: The TRIGger:A:TYPe command.
  • .upperthreshold: The TRIGger:A:UPPerthreshold command tree.
  • .video: The TRIGger:A:VIDeo command.
  • .transition: The TRIGger:A:TRANsition command.
  • .risefall: The TRIGger:A:RISEFall command.

bandwidth property

bandwidth: TriggerABandwidth

Return the TRIGger:A:BANDWidth command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BANDWidth? query.
  • Using the .verify(value) method will send the TRIGger:A:BANDWidth? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .rf: The TRIGger:A:BANDWidth:RF command tree.

bus property

Return the TRIGger:A:BUS command.

Description
  • This command specifies the bus type to trigger on. It supports CAN, I 2 C, SPI, RS-232, Ethernet, MIL-STD-1553, LIN, USB, audio, FlexRay buses (with the appropriate application module installed) as well as parallel signals (with option 3-MSO only.). There are two buses, B1-B2. Each bus can be independently set to one of the serial trigger types.
Usage
  • Using the .query() method will send the TRIGger:A:BUS? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS value command.
SCPI Syntax
- TRIGger:A:BUS {I2C|SPI|CAN|RS232C|PARallel|USB|LIN|FLEXRay|AUDio|ETHERnet|MIL1553B}
- TRIGger:A:BUS?
Info
  • I2C specifies the Inter-IC bus.
  • SPI specifies the Serial Peripheral Interface bus (not available on two-channel models).
  • CAN specifies the Controller Area Network bus.
  • RS232C specifies the RS-232C bus.
  • PARallel specifies the Parallel bus.
  • USB specifies the USB bus.
  • LIN specifies the LIN bus.
  • FLEXRay specifies the FLexRay bus.
  • AUDio specifies the audio bus.
  • ETHERnet specifies the Ethernet bus.
  • MIL1553B specifies the MIL-STD-1553 bus.
Sub-properties
  • .b: The TRIGger:A:BUS:B<x> command tree.
  • .source: The TRIGger:A:BUS:SOUrce command.

edge property

Return the TRIGger:A:EDGE command.

Description
  • Returns the trigger source, coupling, and slope for the A edge trigger.
Usage
  • Using the .query() method will send the TRIGger:A:EDGE? query.
  • Using the .verify(value) method will send the TRIGger:A:EDGE? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:EDGE?
Sub-properties
  • .coupling: The TRIGger:A:EDGE:COUPling command.
  • .slope: The TRIGger:A:EDGE:SLOpe command.
  • .source: The TRIGger:A:EDGE:SOUrce command.

holdoff property

holdoff: TriggerAHoldoff

Return the TRIGger:A:HOLDoff command.

Description
  • Returns the A trigger holdoff parameters. These parameters specify the time period during which the trigger circuitry is not looking to generate a trigger event.
Usage
  • Using the .query() method will send the TRIGger:A:HOLDoff? query.
  • Using the .verify(value) method will send the TRIGger:A:HOLDoff? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:HOLDoff?
Sub-properties
  • .time: The TRIGger:A:HOLDoff:TIMe command.

level property

Return the TRIGger:A:LEVel command tree.

Usage
  • Using the .query() method will send the TRIGger:A:LEVel? query.
  • Using the .verify(value) method will send the TRIGger:A:LEVel? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .auxin: The TRIGger:A:LEVel:AUXin command.
  • .ch: The TRIGger:A:LEVel:CH<x> command.
  • .d: The TRIGger:A:LEVel:D<x> command.

logic property

Return the TRIGger:A:LOGIc command.

Description
  • Returns all of the A logic trigger parameters.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:LOGIc?
Sub-properties
  • .class: The TRIGger:A:LOGIc:CLAss command.
  • .function: The TRIGger:A:LOGIc:FUNCtion command.
  • .input: The TRIGger:A:LOGIc:INPut command.
  • .pattern: The TRIGger:A:LOGIc:PATtern command.
  • .threshold: The TRIGger:A:LOGIc:THReshold command tree.

lowerthreshold property

lowerthreshold: TriggerALowerthreshold

Return the TRIGger:A:LOWerthreshold command tree.

Usage
  • Using the .query() method will send the TRIGger:A:LOWerthreshold? query.
  • Using the .verify(value) method will send the TRIGger:A:LOWerthreshold? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .ch: The TRIGger:A:LOWerthreshold:CH<x> command.
  • .d: The TRIGger:A:LOWerthreshold:D<x> command.
  • .rf: The TRIGger:A:LOWerthreshold:RF command.
  • .aux: The TRIGger:A:LOWerthreshold:AUX command.
  • .ext: The TRIGger:A:LOWerthreshold:EXT command.

mode property

Return the TRIGger:A:MODe command.

Description
  • This command sets or queries the A trigger mode. This command is equivalent to pushing the Mode button on the front panel.
Usage
  • Using the .query() method will send the TRIGger:A:MODe? query.
  • Using the .verify(value) method will send the TRIGger:A:MODe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:MODe value command.
SCPI Syntax
- TRIGger:A:MODe {AUTO|NORMal}
- TRIGger:A:MODe?
Info
  • AUTO generates a trigger if one is not detected within a specified time period.
  • NORMal waits for a valid trigger event.

pulse property

Return the TRIGger:A:PULse command tree.

Usage
  • Using the .query() method will send the TRIGger:A:PULse? query.
  • Using the .verify(value) method will send the TRIGger:A:PULse? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .class: The TRIGger:A:PULse:CLAss command.

pulsewidth property

pulsewidth: TriggerAPulsewidth

Return the TRIGger:A:PULSEWidth command tree.

Usage
  • Using the .query() method will send the TRIGger:A:PULSEWidth? query.
  • Using the .verify(value) method will send the TRIGger:A:PULSEWidth? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .highlimit: The TRIGger:A:PULSEWidth:HIGHLimit command.
  • .lowlimit: The TRIGger:A:PULSEWidth:LOWLimit command.
  • .polarity: The TRIGger:A:PULSEWidth:POLarity command.
  • .source: The TRIGger:A:PULSEWidth:SOUrce command.
  • .when: The TRIGger:A:PULSEWidth:WHEn command.
  • .width: The TRIGger:A:PULSEWidth:WIDth command.

risefall property

risefall: TriggerARisefall

Return the TRIGger:A:RISEFall command.

Description
  • Returns transition time trigger parameters.
Usage
  • Using the .query() method will send the TRIGger:A:RISEFall? query.
  • Using the .verify(value) method will send the TRIGger:A:RISEFall? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:RISEFall?
Sub-properties
  • .deltatime: The TRIGger:A:RISEFall:DELTatime command.
  • .polarity: The TRIGger:A:RISEFall:POLarity command.
  • .source: The TRIGger:A:RISEFall:SOUrce command.
  • .when: The TRIGger:A:RISEFall:WHEn command.

runt property

Return the TRIGger:A:RUNT command.

Description
  • Returns the current A runt trigger parameters.
Usage
  • Using the .query() method will send the TRIGger:A:RUNT? query.
  • Using the .verify(value) method will send the TRIGger:A:RUNT? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:RUNT?
Sub-properties
  • .polarity: The TRIGger:A:RUNT:POLarity command.
  • .source: The TRIGger:A:RUNT:SOUrce command.
  • .when: The TRIGger:A:RUNT:WHEn command.
  • .width: The TRIGger:A:RUNT:WIDth command.

sethold property

sethold: TriggerASethold

Return the TRIGger:A:SETHold command.

Description
  • Returns the clock edge polarity, voltage threshold and source input; data voltage threshold and source; and both setup and hold times for setup and hold violation triggering.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:SETHold?
Sub-properties
  • .clock: The TRIGger:A:SETHold:CLOCk command.
  • .data: The TRIGger:A:SETHold:DATa command.
  • .holdtime: The TRIGger:A:SETHold:HOLDTime command.
  • .settime: The TRIGger:A:SETHold:SETTime command.
  • .threshold: The TRIGger:A:SETHold:THReshold command tree.

timeout property

timeout: TriggerATimeout

Return the TRIGger:A:TIMEOut command tree.

Usage
  • Using the .query() method will send the TRIGger:A:TIMEOut? query.
  • Using the .verify(value) method will send the TRIGger:A:TIMEOut? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .polarity: The TRIGger:A:TIMEOut:POLarity command.
  • .source: The TRIGger:A:TIMEOut:SOUrce command.
  • .time: The TRIGger:A:TIMEOut:TIMe command.

transition property

transition: TriggerATransition

Return the TRIGger:A:TRANsition command.

Description
  • Returns transition time trigger parameters.
Usage
  • Using the .query() method will send the TRIGger:A:TRANsition? query.
  • Using the .verify(value) method will send the TRIGger:A:TRANsition? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:TRANsition?
Sub-properties
  • .deltatime: The TRIGger:A:TRANsition:DELTatime command.
  • .polarity: The TRIGger:A:TRANsition:POLarity command.
  • .source: The TRIGger:A:TRANsition:SOUrce command.
  • .when: The TRIGger:A:TRANsition:WHEn command.

type property

Return the TRIGger:A:TYPe command.

Description
  • This command sets the type of A trigger (either edge, logic, pulse, bus or video). If you set the trigger type to LOGIc, you also need to set the logic trigger class (logic or setup/hold) using the command TRIGGER:A:LOGIC:CLASS. If you set the trigger type to PULSe, you also need to set the pulse trigger class (either runt, width, transition or timeout), using the command TRIGGER:A:PULSE:CLASS. If you set the trigger type to BUS, you also need to set the bus type (CAN, I 2 C, SPI, RS-232, Ethernet, MIL-STD-1553, LIN, USB, audio, FlexRay, or parallel) using the command TRIGGER:A:BUS.
Usage
  • Using the .query() method will send the TRIGger:A:TYPe? query.
  • Using the .verify(value) method will send the TRIGger:A:TYPe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:TYPe value command.
SCPI Syntax
- TRIGger:A:TYPe {EDGe|LOGIc|PULSe|BUS|VIDeo}
- TRIGger:A:TYPe?
Info
  • EDGe is the default trigger. A trigger event occurs when a signal passes through a specified voltage level in a specified direction and is controlled by the TRIGGER:A:EDGE commands.
  • LOGIc specifies that a trigger occurs when specified conditions are met and is controlled by the TRIGGER:A:LOGIC commands. This trigger type is equivalent to the logic and setup/hold triggers found in the user interface. Use TRIGGER:A:LOGIC:CLASS to further select the logic trigger class (either LOGIC or SETHOLD).
  • PULSe specifies that a trigger occurs when a specified pulse is found. Use TRIGGER:A:PULSE:CLASS to further select the pulse trigger class (either runt, width, transition or timeout).
  • BUS specifies that a trigger occurs when a bus signal is found. Supports CAN, I2C, SPI, RS-232, Ethernet, MIL-STD-1553, LIN, USB, audio, FlexRay buses (with the appropriate application module installed) as well as parallel buses. Requires the installation of option 3-MSO. Use TRIGGER:A:BUS to set the bus type.
  • VIDeo specifies that the trigger occurs when a video signal is found.

upperthreshold property

upperthreshold: TriggerAUpperthreshold

Return the TRIGger:A:UPPerthreshold command tree.

Usage
  • Using the .query() method will send the TRIGger:A:UPPerthreshold? query.
  • Using the .verify(value) method will send the TRIGger:A:UPPerthreshold? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .ch: The TRIGger:A:UPPerthreshold:CH<x> command.
  • .rf: The TRIGger:A:UPPerthreshold:RF command.

video property

Return the TRIGger:A:VIDeo command.

Description
  • Returns the A trigger video parameters.
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:VIDeo?
Sub-properties
  • .custom: The TRIGger:A:VIDeo:CUSTom command tree.
  • .holdoff: The TRIGger:A:VIDeo:HOLDoff command tree.
  • .line: The TRIGger:A:VIDeo:LINE command.
  • .polarity: The TRIGger:A:VIDeo:POLarity command.
  • .source: The TRIGger:A:VIDeo:SOUrce command.
  • .standard: The TRIGger:A:VIDeo:STANdard command.
  • .sync: The TRIGger:A:VIDeo:SYNC command.
  • .field: The TRIGger:A:VIDeo:FIELD command.

TriggerABandwidth

Bases: SCPICmdRead

The TRIGger:A:BANDWidth command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BANDWidth? query.
  • Using the .verify(value) method will send the TRIGger:A:BANDWidth? query and raise an AssertionError if the returned value does not match value.
Properties
  • .rf: The TRIGger:A:BANDWidth:RF command tree.

rf property

Return the TRIGger:A:BANDWidth:RF command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BANDWidth:RF? query.
  • Using the .verify(value) method will send the TRIGger:A:BANDWidth:RF? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .high: The TRIGger:A:BANDWidth:RF:HIGH command.
  • .low: The TRIGger:A:BANDWidth:RF:LOW command.

TriggerABandwidthRf

Bases: SCPICmdRead

The TRIGger:A:BANDWidth:RF command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BANDWidth:RF? query.
  • Using the .verify(value) method will send the TRIGger:A:BANDWidth:RF? query and raise an AssertionError if the returned value does not match value.
Properties
  • .high: The TRIGger:A:BANDWidth:RF:HIGH command.
  • .low: The TRIGger:A:BANDWidth:RF:LOW command.

high property

Return the TRIGger:A:BANDWidth:RF:HIGH command.

Description
  • Returns the high end of the power level trigger bandwidth range as an NR3 value in hertz. This is the value that is displayed in the user interface when the trigger source is RF. This command requires the MDO4TRIG advanced trigger feature to be enabled.
Usage
  • Using the .query() method will send the TRIGger:A:BANDWidth:RF:HIGH? query.
  • Using the .verify(value) method will send the TRIGger:A:BANDWidth:RF:HIGH? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:BANDWidth:RF:HIGH?

low property

Return the TRIGger:A:BANDWidth:RF:LOW command.

Description
  • Returns the low end of the power level trigger bandwidth range as an NR3 value in hertz. This is the value that is displayed in the user interface when the trigger source is RF. This command requires the MDO4TRIG advanced trigger feature to be enabled.
Usage
  • Using the .query() method will send the TRIGger:A:BANDWidth:RF:LOW? query.
  • Using the .verify(value) method will send the TRIGger:A:BANDWidth:RF:LOW? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:BANDWidth:RF:LOW?

TriggerABandwidthRfHigh

Bases: SCPICmdRead

The TRIGger:A:BANDWidth:RF:HIGH command.

Description
  • Returns the high end of the power level trigger bandwidth range as an NR3 value in hertz. This is the value that is displayed in the user interface when the trigger source is RF. This command requires the MDO4TRIG advanced trigger feature to be enabled.
Usage
  • Using the .query() method will send the TRIGger:A:BANDWidth:RF:HIGH? query.
  • Using the .verify(value) method will send the TRIGger:A:BANDWidth:RF:HIGH? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:BANDWidth:RF:HIGH?

TriggerABandwidthRfLow

Bases: SCPICmdRead

The TRIGger:A:BANDWidth:RF:LOW command.

Description
  • Returns the low end of the power level trigger bandwidth range as an NR3 value in hertz. This is the value that is displayed in the user interface when the trigger source is RF. This command requires the MDO4TRIG advanced trigger feature to be enabled.
Usage
  • Using the .query() method will send the TRIGger:A:BANDWidth:RF:LOW? query.
  • Using the .verify(value) method will send the TRIGger:A:BANDWidth:RF:LOW? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:BANDWidth:RF:LOW?

TriggerABus

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS command.

Description
  • This command specifies the bus type to trigger on. It supports CAN, I 2 C, SPI, RS-232, Ethernet, MIL-STD-1553, LIN, USB, audio, FlexRay buses (with the appropriate application module installed) as well as parallel signals (with option 3-MSO only.). There are two buses, B1-B2. Each bus can be independently set to one of the serial trigger types.
Usage
  • Using the .query() method will send the TRIGger:A:BUS? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS value command.
SCPI Syntax
- TRIGger:A:BUS {I2C|SPI|CAN|RS232C|PARallel|USB|LIN|FLEXRay|AUDio|ETHERnet|MIL1553B}
- TRIGger:A:BUS?
Info
  • I2C specifies the Inter-IC bus.
  • SPI specifies the Serial Peripheral Interface bus (not available on two-channel models).
  • CAN specifies the Controller Area Network bus.
  • RS232C specifies the RS-232C bus.
  • PARallel specifies the Parallel bus.
  • USB specifies the USB bus.
  • LIN specifies the LIN bus.
  • FLEXRay specifies the FLexRay bus.
  • AUDio specifies the audio bus.
  • ETHERnet specifies the Ethernet bus.
  • MIL1553B specifies the MIL-STD-1553 bus.
Properties
  • .b: The TRIGger:A:BUS:B<x> command tree.
  • .source: The TRIGger:A:BUS:SOUrce command.

b property

Return the TRIGger:A:BUS:B<x> command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .arinc429a: The TRIGger:A:BUS:B<x>:ARINC429A command tree.
  • .audio: The TRIGger:A:BUS:B<x>:AUDio command tree.
  • .can: The TRIGger:A:BUS:B<x>:CAN command tree.
  • .ethernet: The TRIGger:A:BUS:B<x>:ETHERnet command tree.
  • .flexray: The TRIGger:A:BUS:B<x>:FLEXray command tree.
  • .i2c: The TRIGger:A:BUS:B<x>:I2C command tree.
  • .lin: The TRIGger:A:BUS:B<x>:LIN command tree.
  • .mil1553b: The TRIGger:A:BUS:B<x>:MIL1553B command tree.
  • .parallel: The TRIGger:A:BUS:B<x>:PARallel command tree.
  • .rs232c: The TRIGger:A:BUS:B<x>:RS232C command tree.
  • .spi: The TRIGger:A:BUS:B<x>:SPI command tree.
  • .usb: The TRIGger:A:BUS:B<x>:USB command tree.

source property

Return the TRIGger:A:BUS:SOUrce command.

Description
  • This command specifies the source for a serial or parallel bus trigger, with the appropriate application module installed.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:SOUrce value command.
SCPI Syntax
- TRIGger:A:BUS:SOUrce {B<x>}
- TRIGger:A:BUS:SOUrce?
Info
  • B1 specifies the Bus 1 source.
  • B2 specifies the Bus 2 source.
  • B3 specifies the Bus 3 source.
  • B4 specifies the Bus 4 source.

TriggerABusBItem

Bases: ValidatedDynamicNumberCmd, SCPICmdRead

The TRIGger:A:BUS:B<x> command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>? query and raise an AssertionError if the returned value does not match value.
Properties
  • .arinc429a: The TRIGger:A:BUS:B<x>:ARINC429A command tree.
  • .audio: The TRIGger:A:BUS:B<x>:AUDio command tree.
  • .can: The TRIGger:A:BUS:B<x>:CAN command tree.
  • .ethernet: The TRIGger:A:BUS:B<x>:ETHERnet command tree.
  • .flexray: The TRIGger:A:BUS:B<x>:FLEXray command tree.
  • .i2c: The TRIGger:A:BUS:B<x>:I2C command tree.
  • .lin: The TRIGger:A:BUS:B<x>:LIN command tree.
  • .mil1553b: The TRIGger:A:BUS:B<x>:MIL1553B command tree.
  • .parallel: The TRIGger:A:BUS:B<x>:PARallel command tree.
  • .rs232c: The TRIGger:A:BUS:B<x>:RS232C command tree.
  • .spi: The TRIGger:A:BUS:B<x>:SPI command tree.
  • .usb: The TRIGger:A:BUS:B<x>:USB command tree.

arinc429a property

Return the TRIGger:A:BUS:B<x>:ARINC429A command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:ARINC429A? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:ARINC429A? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .condition: The TRIGger:A:BUS:B<x>:ARINC429A:CONDition command.
  • .errtype: The TRIGger:A:BUS:B<x>:ARINC429A:ERRTYPE command.
  • .label: The TRIGger:A:BUS:B<x>:ARINC429A:LABel command tree.
  • .sdi: The TRIGger:A:BUS:B<x>:ARINC429A:SDI command.
  • .ssm: The TRIGger:A:BUS:B<x>:ARINC429A:SSM command.

audio property

Return the TRIGger:A:BUS:B<x>:AUDio command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:AUDio? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:AUDio? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .condition: The TRIGger:A:BUS:B<x>:AUDio:CONDition command.
  • .data: The TRIGger:A:BUS:B<x>:AUDio:DATa command tree.

can property

Return the TRIGger:A:BUS:B<x>:CAN command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .condition: The TRIGger:A:BUS:B<x>:CAN:CONDition command.
  • .data: The TRIGger:A:BUS:B<x>:CAN:DATa command tree.
  • .fd: The TRIGger:A:BUS:B<x>:CAN:FD command tree.
  • .frametype: The TRIGger:A:BUS:B<x>:CAN:FRAMEtype command.
  • .identifier: The TRIGger:A:BUS:B<x>:CAN:IDentifier command tree.
  • .address: The TRIGger:A:BUS:B<x>:CAN:ADDRess command tree.

ethernet property

Return the TRIGger:A:BUS:B<x>:ETHERnet command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:ETHERnet? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:ETHERnet? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .tcpheader: The TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader command tree.

flexray property

Return the TRIGger:A:BUS:B<x>:FLEXray command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .condition: The TRIGger:A:BUS:B<x>:FLEXray:CONDition command.
  • .cyclecount: The TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount command tree.
  • .data: The TRIGger:A:BUS:B<x>:FLEXray:DATa command tree.
  • .eoftype: The TRIGger:A:BUS:B<x>:FLEXray:EOFTYPE command.
  • .errtype: The TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE command.
  • .frameid: The TRIGger:A:BUS:B<x>:FLEXray:FRAMEID command tree.
  • .frametype: The TRIGger:A:BUS:B<x>:FLEXray:FRAMEType command.
  • .header: The TRIGger:A:BUS:B<x>:FLEXray:HEADER command tree.

i2c property

Return the TRIGger:A:BUS:B<x>:I2C command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .address: The TRIGger:A:BUS:B<x>:I2C:ADDRess command tree.
  • .condition: The TRIGger:A:BUS:B<x>:I2C:CONDition command.
  • .data: The TRIGger:A:BUS:B<x>:I2C:DATa command tree.

lin property

Return the TRIGger:A:BUS:B<x>:LIN command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .condition: The TRIGger:A:BUS:B<x>:LIN:CONDition command.
  • .data: The TRIGger:A:BUS:B<x>:LIN:DATa command tree.
  • .errtype: The TRIGger:A:BUS:B<x>:LIN:ERRTYPE command.
  • .identifier: The TRIGger:A:BUS:B<x>:LIN:IDentifier command tree.

mil1553b property

Return the TRIGger:A:BUS:B<x>:MIL1553B command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .command: The TRIGger:A:BUS:B<x>:MIL1553B:COMMAND command tree.
  • .condition: The TRIGger:A:BUS:B<x>:MIL1553B:CONDition command.
  • .data: The TRIGger:A:BUS:B<x>:MIL1553B:DATa command tree.
  • .errtype: The TRIGger:A:BUS:B<x>:MIL1553B:ERRTYPE command.
  • .status: The TRIGger:A:BUS:B<x>:MIL1553B:STATus command tree.
  • .time: The TRIGger:A:BUS:B<x>:MIL1553B:TIMe command tree.

parallel property

Return the TRIGger:A:BUS:B<x>:PARallel command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:PARallel? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:PARallel? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .value: The TRIGger:A:BUS:B<x>:PARallel:VALue command.

rs232c property

Return the TRIGger:A:BUS:B<x>:RS232C command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .condition: The TRIGger:A:BUS:B<x>:RS232C:CONDition command.
  • .rx: The TRIGger:A:BUS:B<x>:RS232C:RX command tree.
  • .tx: The TRIGger:A:BUS:B<x>:RS232C:TX command tree.

spi property

Return the TRIGger:A:BUS:B<x>:SPI command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .condition: The TRIGger:A:BUS:B<x>:SPI:CONDition command.
  • .data: The TRIGger:A:BUS:B<x>:SPI:DATa command tree.

usb property

Return the TRIGger:A:BUS:B<x>:USB command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .address: The TRIGger:A:BUS:B<x>:USB:ADDRess command tree.
  • .condition: The TRIGger:A:BUS:B<x>:USB:CONDition command.
  • .data: The TRIGger:A:BUS:B<x>:USB:DATa command tree.
  • .endpoint: The TRIGger:A:BUS:B<x>:USB:ENDPoint command tree.
  • .errtype: The TRIGger:A:BUS:B<x>:USB:ERRTYPE command.
  • .handshaketype: The TRIGger:A:BUS:B<x>:USB:HANDSHAKEType command.
  • .qualifier: The TRIGger:A:BUS:B<x>:USB:QUALifier command.
  • .sofframenumber: The TRIGger:A:BUS:B<x>:USB:SOFFRAMENUMber command.
  • .specialtype: The TRIGger:A:BUS:B<x>:USB:SPECIALType command.
  • .split: The TRIGger:A:BUS:B<x>:USB:SPLit command tree.
  • .tokentype: The TRIGger:A:BUS:B<x>:USB:TOKENType command.

TriggerABusBItemArinc429a

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:ARINC429A command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:ARINC429A? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:ARINC429A? query and raise an AssertionError if the returned value does not match value.
Properties
  • .condition: The TRIGger:A:BUS:B<x>:ARINC429A:CONDition command.
  • .errtype: The TRIGger:A:BUS:B<x>:ARINC429A:ERRTYPE command.
  • .label: The TRIGger:A:BUS:B<x>:ARINC429A:LABel command tree.
  • .sdi: The TRIGger:A:BUS:B<x>:ARINC429A:SDI command.
  • .ssm: The TRIGger:A:BUS:B<x>:ARINC429A:SSM command.

condition property

Return the TRIGger:A:BUS:B<x>:ARINC429A:CONDition command.

Description
  • This command sets the condition (word start, label, matching data, word end, or error) to be used to trigger on CAN bus data. B is the bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:ARINC429A:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:ARINC429A:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:ARINC429A:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:ARINC429A:CONDition {STARt|END|LABel|DATA|LABELANDDATA|ERRor}
- TRIGger:A:BUS:B<x>:ARINC429A:CONDition?
Info
  • STARt enables triggering on the first bit of a word.
  • END enables triggering on the 32nd bit of a word.
  • LABel enables trigger on a matching label.
  • DATA enables triggering on matching packet data field(s).
  • LABELANDDATA enables triggering on matching label and matching packet data field(s).
  • ERROR enables triggering on a specified packet error.

errtype property

Return the TRIGger:A:BUS:B<x>:ARINC429A:ERRTYPE command.

Description
  • This command specifies the error type when triggering on an ARINC429 bus signal. The trigger condition needs to be set to ERROR (using TRIGGER:A:BUS:BX:ARINC429A:CONDITION). B is the bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:ARINC429A:ERRTYPE? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:ARINC429A:ERRTYPE? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:ARINC429A:ERRTYPE value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:ARINC429A:ERRTYPE {ANY|GAP|WORD|PARity}
- TRIGger:A:BUS:B<x>:ARINC429A:ERRTYPE?
Info
  • ANY sets the error type to match any of the other available error types.
  • GAP sets the error type to match on gap violations (less than 4 bits idle time between two packets on the bus).
  • WORD sets the error type to match on word errors (incorrect number of bits in a word or bits that violate return to zero transmission).
  • PARity sets the error type to match on parity errors (parity value results in even parity count for a word).

label property

Return the TRIGger:A:BUS:B<x>:ARINC429A:LABel command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:ARINC429A:LABel? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:ARINC429A:LABel? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .hivalue: The TRIGger:A:BUS:B<x>:ARINC429A:LABel:HIVALue command.
  • .qualifier: The TRIGger:A:BUS:B<x>:ARINC429A:LABel:QUALifier command.
  • .value: The TRIGger:A:BUS:B<x>:ARINC429A:LABel:VALue command.

sdi property

Return the TRIGger:A:BUS:B<x>:ARINC429A:SDI command.

Description
  • This command specifies the value for the SDI field to be used when triggering on the ARINC429 bus data field(s). The trigger condition must be set to DATA or LABELANDDATA (using TRIGGER:A:BUS:BX:ARINC429A:CONDITION). The default is all X’s (don’t care). B is the bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:ARINC429A:SDI? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:ARINC429A:SDI? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:ARINC429A:SDI value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:ARINC429A:SDI <QString>
- TRIGger:A:BUS:B<x>:ARINC429A:SDI?

ssm property

Return the TRIGger:A:BUS:B<x>:ARINC429A:SSM command.

Description
  • This command specifies the value for the SSM field to be used when triggering on the ARINC429 bus data field(s). The trigger condition must be set to DATA or LABELANDDATA (using TRIGGER:A:BUS:BX:ARINC429A:CONDITION). The default is all X’s (don’t care). B is the bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:ARINC429A:SSM? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:ARINC429A:SSM? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:ARINC429A:SSM value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:ARINC429A:SSM <QString>
- TRIGger:A:BUS:B<x>:ARINC429A:SSM?

TriggerABusBItemArinc429aCondition

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:ARINC429A:CONDition command.

Description
  • This command sets the condition (word start, label, matching data, word end, or error) to be used to trigger on CAN bus data. B is the bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:ARINC429A:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:ARINC429A:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:ARINC429A:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:ARINC429A:CONDition {STARt|END|LABel|DATA|LABELANDDATA|ERRor}
- TRIGger:A:BUS:B<x>:ARINC429A:CONDition?
Info
  • STARt enables triggering on the first bit of a word.
  • END enables triggering on the 32nd bit of a word.
  • LABel enables trigger on a matching label.
  • DATA enables triggering on matching packet data field(s).
  • LABELANDDATA enables triggering on matching label and matching packet data field(s).
  • ERROR enables triggering on a specified packet error.

TriggerABusBItemArinc429aErrtype

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:ARINC429A:ERRTYPE command.

Description
  • This command specifies the error type when triggering on an ARINC429 bus signal. The trigger condition needs to be set to ERROR (using TRIGGER:A:BUS:BX:ARINC429A:CONDITION). B is the bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:ARINC429A:ERRTYPE? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:ARINC429A:ERRTYPE? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:ARINC429A:ERRTYPE value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:ARINC429A:ERRTYPE {ANY|GAP|WORD|PARity}
- TRIGger:A:BUS:B<x>:ARINC429A:ERRTYPE?
Info
  • ANY sets the error type to match any of the other available error types.
  • GAP sets the error type to match on gap violations (less than 4 bits idle time between two packets on the bus).
  • WORD sets the error type to match on word errors (incorrect number of bits in a word or bits that violate return to zero transmission).
  • PARity sets the error type to match on parity errors (parity value results in even parity count for a word).

TriggerABusBItemArinc429aLabel

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:ARINC429A:LABel command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:ARINC429A:LABel? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:ARINC429A:LABel? query and raise an AssertionError if the returned value does not match value.
Properties
  • .hivalue: The TRIGger:A:BUS:B<x>:ARINC429A:LABel:HIVALue command.
  • .qualifier: The TRIGger:A:BUS:B<x>:ARINC429A:LABel:QUALifier command.
  • .value: The TRIGger:A:BUS:B<x>:ARINC429A:LABel:VALue command.

hivalue property

Return the TRIGger:A:BUS:B<x>:ARINC429A:LABel:HIVALue command.

Description
  • When the trigger condition is set to LABel, and the qualifier is set to either INrange or OUTrange, this command specifies the upper value of the range for a trigger on the label field. (Use the command TRIGGER:A:BUS:BX:ARINC429A:LABEL:VALUE to specify the lower value of the range). The default is all X’s (don’t care). B is the bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:ARINC429A:LABel:HIVALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:ARINC429A:LABel:HIVALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:ARINC429A:LABel:HIVALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:ARINC429A:LABel:HIVALue <QString>
- TRIGger:A:BUS:B<x>:ARINC429A:LABel:HIVALue?

qualifier property

Return the TRIGger:A:BUS:B<x>:ARINC429A:LABel:QUALifier command.

Description
  • This command specifies the qualifier to be used when triggering on the ARINC429 label field. The trigger condition must be set to LABel or LABELANDDATA. The default qualifier is ‘Equal to’. B is the bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:ARINC429A:LABel:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:ARINC429A:LABel:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:ARINC429A:LABel:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:ARINC429A:LABel:QUALifier {LESSthan|MOREthan|Equal|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:ARINC429A:LABel:QUALifier?
Info
  • LESSthan sets label qualifier to less than.
  • MOREthan sets the label qualifier to greater than.
  • EQual sets the label qualifier to equal.
  • UNEQual sets the label qualifier to not equal.
  • LESSEQual sets the label qualifier to less than or equal.
  • MOREEQual sets the label qualifier to greater than or equal.
  • INrange sets the label qualifier to in range.
  • OUTrange sets the label qualifier to out of range.

value property

Return the TRIGger:A:BUS:B<x>:ARINC429A:LABel:VALue command.

Description
  • This command specifies the low value to be used when triggering on the ARINC429 bus label field. The trigger condition must be set to LABel or LABELANDDATA (using TRIGGER:A:BUS:BX:ARINC429A:CONDITION). The default is all X’s (don’t care). B is the bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:ARINC429A:LABel:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:ARINC429A:LABel:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:ARINC429A:LABel:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:ARINC429A:LABel:VALue <QString>
- TRIGger:A:BUS:B<x>:ARINC429A:LABel:VALue?

TriggerABusBItemArinc429aLabelHivalue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:ARINC429A:LABel:HIVALue command.

Description
  • When the trigger condition is set to LABel, and the qualifier is set to either INrange or OUTrange, this command specifies the upper value of the range for a trigger on the label field. (Use the command TRIGGER:A:BUS:BX:ARINC429A:LABEL:VALUE to specify the lower value of the range). The default is all X’s (don’t care). B is the bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:ARINC429A:LABel:HIVALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:ARINC429A:LABel:HIVALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:ARINC429A:LABel:HIVALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:ARINC429A:LABel:HIVALue <QString>
- TRIGger:A:BUS:B<x>:ARINC429A:LABel:HIVALue?

TriggerABusBItemArinc429aLabelQualifier

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:ARINC429A:LABel:QUALifier command.

Description
  • This command specifies the qualifier to be used when triggering on the ARINC429 label field. The trigger condition must be set to LABel or LABELANDDATA. The default qualifier is ‘Equal to’. B is the bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:ARINC429A:LABel:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:ARINC429A:LABel:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:ARINC429A:LABel:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:ARINC429A:LABel:QUALifier {LESSthan|MOREthan|Equal|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:ARINC429A:LABel:QUALifier?
Info
  • LESSthan sets label qualifier to less than.
  • MOREthan sets the label qualifier to greater than.
  • EQual sets the label qualifier to equal.
  • UNEQual sets the label qualifier to not equal.
  • LESSEQual sets the label qualifier to less than or equal.
  • MOREEQual sets the label qualifier to greater than or equal.
  • INrange sets the label qualifier to in range.
  • OUTrange sets the label qualifier to out of range.

TriggerABusBItemArinc429aLabelValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:ARINC429A:LABel:VALue command.

Description
  • This command specifies the low value to be used when triggering on the ARINC429 bus label field. The trigger condition must be set to LABel or LABELANDDATA (using TRIGGER:A:BUS:BX:ARINC429A:CONDITION). The default is all X’s (don’t care). B is the bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:ARINC429A:LABel:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:ARINC429A:LABel:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:ARINC429A:LABel:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:ARINC429A:LABel:VALue <QString>
- TRIGger:A:BUS:B<x>:ARINC429A:LABel:VALue?

TriggerABusBItemArinc429aSdi

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:ARINC429A:SDI command.

Description
  • This command specifies the value for the SDI field to be used when triggering on the ARINC429 bus data field(s). The trigger condition must be set to DATA or LABELANDDATA (using TRIGGER:A:BUS:BX:ARINC429A:CONDITION). The default is all X’s (don’t care). B is the bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:ARINC429A:SDI? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:ARINC429A:SDI? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:ARINC429A:SDI value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:ARINC429A:SDI <QString>
- TRIGger:A:BUS:B<x>:ARINC429A:SDI?

TriggerABusBItemArinc429aSsm

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:ARINC429A:SSM command.

Description
  • This command specifies the value for the SSM field to be used when triggering on the ARINC429 bus data field(s). The trigger condition must be set to DATA or LABELANDDATA (using TRIGGER:A:BUS:BX:ARINC429A:CONDITION). The default is all X’s (don’t care). B is the bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:ARINC429A:SSM? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:ARINC429A:SSM? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:ARINC429A:SSM value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:ARINC429A:SSM <QString>
- TRIGger:A:BUS:B<x>:ARINC429A:SSM?

TriggerABusBItemAudio

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:AUDio command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:AUDio? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:AUDio? query and raise an AssertionError if the returned value does not match value.
Properties
  • .condition: The TRIGger:A:BUS:B<x>:AUDio:CONDition command.
  • .data: The TRIGger:A:BUS:B<x>:AUDio:DATa command tree.

condition property

Return the TRIGger:A:BUS:B<x>:AUDio:CONDition command.

Description
  • This command sets the condition (start of frame or matching data) to be used when triggering on an audio bus signal. B is the bus number (1-2).
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:AUDio:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:AUDio:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:AUDio:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:AUDio:CONDition {SOF|DATA}
- TRIGger:A:BUS:B<x>:AUDio:CONDition?
Info
  • SOF enables triggering on the start of frame.
  • DATA enables triggering on matching data.

data property

Return the TRIGger:A:BUS:B<x>:AUDio:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:AUDio:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:AUDio:DATa? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .hivalue: The TRIGger:A:BUS:B<x>:AUDio:DATa:HIVALue command.
  • .offset: The TRIGger:A:BUS:B<x>:AUDio:DATa:OFFSet command.
  • .qualifier: The TRIGger:A:BUS:B<x>:AUDio:DATa:QUALifier command.
  • .value: The TRIGger:A:BUS:B<x>:AUDio:DATa:VALue command.
  • .word: The TRIGger:A:BUS:B<x>:AUDio:DATa:WORD command.

TriggerABusBItemAudioCondition

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:AUDio:CONDition command.

Description
  • This command sets the condition (start of frame or matching data) to be used when triggering on an audio bus signal. B is the bus number (1-2).
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:AUDio:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:AUDio:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:AUDio:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:AUDio:CONDition {SOF|DATA}
- TRIGger:A:BUS:B<x>:AUDio:CONDition?
Info
  • SOF enables triggering on the start of frame.
  • DATA enables triggering on matching data.

TriggerABusBItemAudioData

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:AUDio:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:AUDio:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:AUDio:DATa? query and raise an AssertionError if the returned value does not match value.
Properties
  • .hivalue: The TRIGger:A:BUS:B<x>:AUDio:DATa:HIVALue command.
  • .offset: The TRIGger:A:BUS:B<x>:AUDio:DATa:OFFSet command.
  • .qualifier: The TRIGger:A:BUS:B<x>:AUDio:DATa:QUALifier command.
  • .value: The TRIGger:A:BUS:B<x>:AUDio:DATa:VALue command.
  • .word: The TRIGger:A:BUS:B<x>:AUDio:DATa:WORD command.

hivalue property

Return the TRIGger:A:BUS:B<x>:AUDio:DATa:HIVALue command.

Description
  • This command sets the upper word value to be used when triggering on an audio bus signal. The trigger condition must be set to DATA using TRIGGER:A:BUS:BX:AUDIO:CONDITION. B is the bus number (1-2).
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:AUDio:DATa:HIVALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:AUDio:DATa:HIVALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:AUDio:DATa:HIVALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:AUDio:DATa:HIVALue <String>
- TRIGger:A:BUS:B<x>:AUDio:DATa:HIVALue?

offset property

Return the TRIGger:A:BUS:B<x>:AUDio:DATa:OFFSet command.

Description
  • This command sets the data offset value to be used when triggering on an audio bus signal. The trigger condition must be set to DATA using TRIGGER:A:BUS:BX:AUDIO:CONDITION. B is the bus number (1-2).
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:AUDio:DATa:OFFSet? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:AUDio:DATa:OFFSet? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:AUDio:DATa:OFFSet value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:AUDio:DATa:OFFSet <NR1>
- TRIGger:A:BUS:B<x>:AUDio:DATa:OFFSet?
Info
  • <NR1> is the data offset value.

qualifier property

Return the TRIGger:A:BUS:B<x>:AUDio:DATa:QUALifier command.

Description
  • This command sets the qualifier (<, >, =, <=, >=, not =, in range, out of range) to be used when triggering on an audio bus signal. The trigger condition must be set to DATA using TRIGGER:A:BUS:BX:AUDIO:CONDITION. B is the bus number (1-2).
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:AUDio:DATa:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:AUDio:DATa:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:AUDio:DATa:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:AUDio:DATa:QUALifier {LESSthan|MOREthan|EQual|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:AUDio:DATa:QUALifier?
Info
  • LESSthan sets the qualifier to less than.
  • MOREthan sets the qualifier to greater than.
  • EQual sets the qualifier to equal.
  • UNEQual sets the qualifier to not equal.
  • LESSEQual sets the qualifier to less than or equal.
  • MOREEQual sets the qualifier to greater than or equal.
  • INrange sets the qualifier to in range.
  • OUTrange sets the qualifier to out of range.

value property

Return the TRIGger:A:BUS:B<x>:AUDio:DATa:VALue command.

Description
  • This command sets the lower word value to be used when triggering on an audio bus signal. The trigger condition must be set to DATA using TRIGGER:A:BUS:BX:AUDIO:CONDITION. B is the bus number (1-2).
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:AUDio:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:AUDio:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:AUDio:DATa:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:AUDio:DATa:VALue <String>
- TRIGger:A:BUS:B<x>:AUDio:DATa:VALue?
Info
  • <String> specifies the trigger data lower word.

word property

Return the TRIGger:A:BUS:B<x>:AUDio:DATa:WORD command.

Description
  • This command sets the alignment of the data (left, right or either) to be used to trigger on an audio bus signal. The trigger condition must be set to DATA using TRIGGER:A:BUS:BX:AUDIO:CONDITION. B is the bus number (1-2).
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:AUDio:DATa:WORD? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:AUDio:DATa:WORD? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:AUDio:DATa:WORD value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:AUDio:DATa:WORD {EITher|LEFt|RIGht}
- TRIGger:A:BUS:B<x>:AUDio:DATa:WORD?
Info
  • EITher aligns the trigger data to either left or right.
  • LEFt aligns the trigger data to the left.
  • RIGht aligns the trigger data to the right.

TriggerABusBItemAudioDataHivalue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:AUDio:DATa:HIVALue command.

Description
  • This command sets the upper word value to be used when triggering on an audio bus signal. The trigger condition must be set to DATA using TRIGGER:A:BUS:BX:AUDIO:CONDITION. B is the bus number (1-2).
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:AUDio:DATa:HIVALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:AUDio:DATa:HIVALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:AUDio:DATa:HIVALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:AUDio:DATa:HIVALue <String>
- TRIGger:A:BUS:B<x>:AUDio:DATa:HIVALue?

TriggerABusBItemAudioDataOffset

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:AUDio:DATa:OFFSet command.

Description
  • This command sets the data offset value to be used when triggering on an audio bus signal. The trigger condition must be set to DATA using TRIGGER:A:BUS:BX:AUDIO:CONDITION. B is the bus number (1-2).
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:AUDio:DATa:OFFSet? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:AUDio:DATa:OFFSet? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:AUDio:DATa:OFFSet value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:AUDio:DATa:OFFSet <NR1>
- TRIGger:A:BUS:B<x>:AUDio:DATa:OFFSet?
Info
  • <NR1> is the data offset value.

TriggerABusBItemAudioDataQualifier

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:AUDio:DATa:QUALifier command.

Description
  • This command sets the qualifier (<, >, =, <=, >=, not =, in range, out of range) to be used when triggering on an audio bus signal. The trigger condition must be set to DATA using TRIGGER:A:BUS:BX:AUDIO:CONDITION. B is the bus number (1-2).
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:AUDio:DATa:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:AUDio:DATa:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:AUDio:DATa:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:AUDio:DATa:QUALifier {LESSthan|MOREthan|EQual|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:AUDio:DATa:QUALifier?
Info
  • LESSthan sets the qualifier to less than.
  • MOREthan sets the qualifier to greater than.
  • EQual sets the qualifier to equal.
  • UNEQual sets the qualifier to not equal.
  • LESSEQual sets the qualifier to less than or equal.
  • MOREEQual sets the qualifier to greater than or equal.
  • INrange sets the qualifier to in range.
  • OUTrange sets the qualifier to out of range.

TriggerABusBItemAudioDataValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:AUDio:DATa:VALue command.

Description
  • This command sets the lower word value to be used when triggering on an audio bus signal. The trigger condition must be set to DATA using TRIGGER:A:BUS:BX:AUDIO:CONDITION. B is the bus number (1-2).
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:AUDio:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:AUDio:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:AUDio:DATa:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:AUDio:DATa:VALue <String>
- TRIGger:A:BUS:B<x>:AUDio:DATa:VALue?
Info
  • <String> specifies the trigger data lower word.

TriggerABusBItemAudioDataWord

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:AUDio:DATa:WORD command.

Description
  • This command sets the alignment of the data (left, right or either) to be used to trigger on an audio bus signal. The trigger condition must be set to DATA using TRIGGER:A:BUS:BX:AUDIO:CONDITION. B is the bus number (1-2).
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:AUDio:DATa:WORD? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:AUDio:DATa:WORD? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:AUDio:DATa:WORD value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:AUDio:DATa:WORD {EITher|LEFt|RIGht}
- TRIGger:A:BUS:B<x>:AUDio:DATa:WORD?
Info
  • EITher aligns the trigger data to either left or right.
  • LEFt aligns the trigger data to the left.
  • RIGht aligns the trigger data to the right.

TriggerABusBItemCan

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN? query and raise an AssertionError if the returned value does not match value.
Properties
  • .condition: The TRIGger:A:BUS:B<x>:CAN:CONDition command.
  • .data: The TRIGger:A:BUS:B<x>:CAN:DATa command tree.
  • .fd: The TRIGger:A:BUS:B<x>:CAN:FD command tree.
  • .frametype: The TRIGger:A:BUS:B<x>:CAN:FRAMEtype command.
  • .identifier: The TRIGger:A:BUS:B<x>:CAN:IDentifier command tree.
  • .address: The TRIGger:A:BUS:B<x>:CAN:ADDRess command tree.

address property

Return the TRIGger:A:BUS:B<x>:CAN:ADDRess command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:ADDRess? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:ADDRess? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .mode: The TRIGger:A:BUS:B<x>:CAN:ADDRess:MODe command.
  • .value: The TRIGger:A:BUS:B<x>:CAN:ADDRess:VALue command.

condition property

Return the TRIGger:A:BUS:B<x>:CAN:CONDition command.

Description
  • This command sets the condition (start of frame, frame type, identifier, matching data, end of frame, missing ACK field, bit-stuffing error, form error, any error, CAN FD BRS bit, or CAN FD ESI bit) to be used to search on CAN bus data. B is the bus number (1-2).
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:CONDition {SOF|FRAMEtype|IDentifier|DATA|IDANDDATA|EOF|ACKMISS|ERROR|FORMERRor|ANYERRor|FDBRS|FDESI}
- TRIGger:A:BUS:B<x>:CAN:CONDition?
Info
  • SOF enables triggering on the start of frame.
  • FRAMEtype enables triggering on the type of frame.
  • IDentifier enables triggering on a matching identifier.
  • DATA enables triggering on matching data.
  • IDANDDATA enables triggering on a matching identifier and matching data.
  • EOF enables triggering on the end of frame.
  • ACKMISS enables triggering on a missing acknowledge.
  • ERROR enables triggering on bit stuffing errors.
  • FORMERRor enables triggering on packet form errors.
  • ANYERRor enables triggering on any packet error (missing ACK, bit stuffing error, or form error).
  • FDBRS enables triggering on a CAN FD frame’s BRS bit.
  • FDESI enables triggering on a CAN FD frame’s ESI bit.

data property

Return the TRIGger:A:BUS:B<x>:CAN:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .direction: The TRIGger:A:BUS:B<x>:CAN:DATa:DIRection command.
  • .offset: The TRIGger:A:BUS:B<x>:CAN:DATa:OFFSet command.
  • .qualifier: The TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier command.
  • .size: The TRIGger:A:BUS:B<x>:CAN:DATa:SIZe command.
  • .value: The TRIGger:A:BUS:B<x>:CAN:DATa:VALue command.

fd property

Return the TRIGger:A:BUS:B<x>:CAN:FD command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:FD? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:FD? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .brsbit: The TRIGger:A:BUS:B<x>:CAN:FD:BRSBIT command.
  • .esibit: The TRIGger:A:BUS:B<x>:CAN:FD:ESIBIT command.

frametype property

Return the TRIGger:A:BUS:B<x>:CAN:FRAMEtype command.

Description
  • This command sets the frame type (data, remote, error or overload) to be used when triggering on a CAN bus signal. The trigger condition must be set to FRAMEtype (using TRIGGER:A:BUS:BX:CAN:CONDITION). B is the bus number (1-2).
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:FRAMEtype? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:FRAMEtype? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:FRAMEtype value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:FRAMEtype {DATA|REMote|ERRor|OVERLoad}
- TRIGger:A:BUS:B<x>:CAN:FRAMEtype?
Info
  • DATA specifies a data frame type.
  • REMote specifies a remote frame type.
  • ERRor specifies an error frame type.
  • OVERLold specifies an overload frame type.

identifier property

Return the TRIGger:A:BUS:B<x>:CAN:IDentifier command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .mode: The TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe command.
  • .value: The TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue command.

TriggerABusBItemCanAddress

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:ADDRess command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:ADDRess? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:ADDRess? query and raise an AssertionError if the returned value does not match value.
Properties
  • .mode: The TRIGger:A:BUS:B<x>:CAN:ADDRess:MODe command.
  • .value: The TRIGger:A:BUS:B<x>:CAN:ADDRess:VALue command.

mode property

Return the TRIGger:A:BUS:B<x>:CAN:ADDRess:MODe command.

Description
  • This command sets the addressing mode (standard or extended format) to be used when triggering on a CAN bus signal. The trigger condition must be set to IDANDDATA OR DATA (using TRIGGER:A:BUS:BX:CAN:CONDITION). B is the bus number (1-2).
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:ADDRess:MODe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:ADDRess:MODe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:ADDRess:MODe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:ADDRess:MODe {STandard|EXTENDed}
- TRIGger:A:BUS:B<x>:CAN:ADDRess:MODe?
Info
  • STandard specifies the standard addressing mode.
  • EXTENDed specifies the extended addressing mode.

value property

Return the TRIGger:A:BUS:B<x>:CAN:ADDRess:VALue command.

Description
  • This command sets the binary address value to be used when triggering on a CAN bus signal. The trigger condition must be set to IDANDDATA OR DATA (using TRIGGER:A:BUS:BX:CAN:CONDITION). B is the bus number (1-2).
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:ADDRess:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:ADDRess:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:ADDRess:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:ADDRess:VALue <QString>
- TRIGger:A:BUS:B<x>:CAN:ADDRess:VALue?
Info
  • <QString> is up to 29 bits specifying the binary identifier value. The only allowed characters in the QString are 0, 1, and X.

TriggerABusBItemCanAddressMode

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:ADDRess:MODe command.

Description
  • This command sets the addressing mode (standard or extended format) to be used when triggering on a CAN bus signal. The trigger condition must be set to IDANDDATA OR DATA (using TRIGGER:A:BUS:BX:CAN:CONDITION). B is the bus number (1-2).
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:ADDRess:MODe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:ADDRess:MODe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:ADDRess:MODe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:ADDRess:MODe {STandard|EXTENDed}
- TRIGger:A:BUS:B<x>:CAN:ADDRess:MODe?
Info
  • STandard specifies the standard addressing mode.
  • EXTENDed specifies the extended addressing mode.

TriggerABusBItemCanAddressValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:ADDRess:VALue command.

Description
  • This command sets the binary address value to be used when triggering on a CAN bus signal. The trigger condition must be set to IDANDDATA OR DATA (using TRIGGER:A:BUS:BX:CAN:CONDITION). B is the bus number (1-2).
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:ADDRess:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:ADDRess:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:ADDRess:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:ADDRess:VALue <QString>
- TRIGger:A:BUS:B<x>:CAN:ADDRess:VALue?
Info
  • <QString> is up to 29 bits specifying the binary identifier value. The only allowed characters in the QString are 0, 1, and X.

TriggerABusBItemCanCondition

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:CONDition command.

Description
  • This command sets the condition (start of frame, frame type, identifier, matching data, end of frame, missing ACK field, bit-stuffing error, form error, any error, CAN FD BRS bit, or CAN FD ESI bit) to be used to search on CAN bus data. B is the bus number (1-2).
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:CONDition {SOF|FRAMEtype|IDentifier|DATA|IDANDDATA|EOF|ACKMISS|ERROR|FORMERRor|ANYERRor|FDBRS|FDESI}
- TRIGger:A:BUS:B<x>:CAN:CONDition?
Info
  • SOF enables triggering on the start of frame.
  • FRAMEtype enables triggering on the type of frame.
  • IDentifier enables triggering on a matching identifier.
  • DATA enables triggering on matching data.
  • IDANDDATA enables triggering on a matching identifier and matching data.
  • EOF enables triggering on the end of frame.
  • ACKMISS enables triggering on a missing acknowledge.
  • ERROR enables triggering on bit stuffing errors.
  • FORMERRor enables triggering on packet form errors.
  • ANYERRor enables triggering on any packet error (missing ACK, bit stuffing error, or form error).
  • FDBRS enables triggering on a CAN FD frame’s BRS bit.
  • FDESI enables triggering on a CAN FD frame’s ESI bit.

TriggerABusBItemCanData

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa? query and raise an AssertionError if the returned value does not match value.
Properties
  • .direction: The TRIGger:A:BUS:B<x>:CAN:DATa:DIRection command.
  • .offset: The TRIGger:A:BUS:B<x>:CAN:DATa:OFFSet command.
  • .qualifier: The TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier command.
  • .size: The TRIGger:A:BUS:B<x>:CAN:DATa:SIZe command.
  • .value: The TRIGger:A:BUS:B<x>:CAN:DATa:VALue command.

direction property

Return the TRIGger:A:BUS:B<x>:CAN:DATa:DIRection command.

Description
  • This command sets the data direction (read, write or ‘nocare’) to be used to search on a CAN bus signal. The trigger condition must be set to IDentifier (using TRIGGER:A:BUS:BX:CAN:CONDITION). The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:DATa:DIRection? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:DIRection? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:DIRection value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:DATa:DIRection {READ|WRITE|NOCARE}
- TRIGger:A:BUS:B<x>:CAN:DATa:DIRection?
Info
  • READ sets the CAN data direction to READ.
  • WRITE sets the CAN data direction to WRITE.
  • NOCARE sets the CAN data direction to either.

offset property

Return the TRIGger:A:BUS:B<x>:CAN:DATa:OFFSet command.

Description
  • This command sets or queries the data offset value, in bytes, to use when triggering on the CAN data field. The bus number is specified by x. The trigger condition must be set to DATA or IDANDDATA.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:DATa:OFFSet? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:OFFSet? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:OFFSet value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:DATa:OFFSet <NR1>
- TRIGger:A:BUS:B<x>:CAN:DATa:OFFSet?
Info
  • <NR1> is an integer whose minimum and default values are -1 (don’t care), and the maximum is up to 7 (for CAN 2.0) or up to 63 (for ISO CAN FD and Non-ISO CAN FD).

qualifier property

Return the TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier command.

Description
  • This command sets the qualifier (<, >, =, not =, <=) to be used when triggering on a CAN bus signal. The trigger condition must be set to IDANDDATA OR DATA (using TRIGGER:A:BUS:BX:CAN:CONDITION). B is the bus number (1-2).
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier {LESSthan|Than|EQual|UNEQual|LESSEQual|EQual}
- TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier?
Info
  • LESSthan sets the oscilloscope to trigger when the data is less than the qualifier value.
  • Than sets the oscilloscope to trigger when the data is than the qualifier value.
  • EQual sets the oscilloscope to trigger when the data is equal to the qualifier value.
  • UNEQual sets the oscilloscope to trigger when the data is not equal to the qualifier value.
  • LESSEQual sets the oscilloscope to trigger when the data is less than or equal to the qualifier value.
  • EQual sets the oscilloscope to trigger when the data is than or equal to the qualifier value.

size property

Return the TRIGger:A:BUS:B<x>:CAN:DATa:SIZe command.

Description
  • This command sets the length of the data string, in bytes, to be used when triggering on a CAN bus signal. The trigger condition must be set to IDANDDATA or DATa (using TRIGGER:A:BUS:BX:CAN:CONDITION). The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:CAN:DATa:SIZe?
Info
  • <NR1> is the length of the data string in bytes.

value property

Return the TRIGger:A:BUS:B<x>:CAN:DATa:VALue command.

Description
  • This command sets the binary data value to be used when triggering on a CAN bus signal. The trigger condition must be set to IDANDDATA or DATa (using TRIGGER:A:BUS:BX:CAN:CONDITION). The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:CAN:DATa:VALue?
Info
  • <QString> is the data value in binary format. The only allowed characters in the QString are 0, 1, and X.

TriggerABusBItemCanDataDirection

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:DATa:DIRection command.

Description
  • This command sets the data direction (read, write or ‘nocare’) to be used to search on a CAN bus signal. The trigger condition must be set to IDentifier (using TRIGGER:A:BUS:BX:CAN:CONDITION). The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:DATa:DIRection? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:DIRection? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:DIRection value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:DATa:DIRection {READ|WRITE|NOCARE}
- TRIGger:A:BUS:B<x>:CAN:DATa:DIRection?
Info
  • READ sets the CAN data direction to READ.
  • WRITE sets the CAN data direction to WRITE.
  • NOCARE sets the CAN data direction to either.

TriggerABusBItemCanDataOffset

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:DATa:OFFSet command.

Description
  • This command sets or queries the data offset value, in bytes, to use when triggering on the CAN data field. The bus number is specified by x. The trigger condition must be set to DATA or IDANDDATA.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:DATa:OFFSet? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:OFFSet? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:OFFSet value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:DATa:OFFSet <NR1>
- TRIGger:A:BUS:B<x>:CAN:DATa:OFFSet?
Info
  • <NR1> is an integer whose minimum and default values are -1 (don’t care), and the maximum is up to 7 (for CAN 2.0) or up to 63 (for ISO CAN FD and Non-ISO CAN FD).

TriggerABusBItemCanDataQualifier

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier command.

Description
  • This command sets the qualifier (<, >, =, not =, <=) to be used when triggering on a CAN bus signal. The trigger condition must be set to IDANDDATA OR DATA (using TRIGGER:A:BUS:BX:CAN:CONDITION). B is the bus number (1-2).
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier {LESSthan|Than|EQual|UNEQual|LESSEQual|EQual}
- TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier?
Info
  • LESSthan sets the oscilloscope to trigger when the data is less than the qualifier value.
  • Than sets the oscilloscope to trigger when the data is than the qualifier value.
  • EQual sets the oscilloscope to trigger when the data is equal to the qualifier value.
  • UNEQual sets the oscilloscope to trigger when the data is not equal to the qualifier value.
  • LESSEQual sets the oscilloscope to trigger when the data is less than or equal to the qualifier value.
  • EQual sets the oscilloscope to trigger when the data is than or equal to the qualifier value.

TriggerABusBItemCanDataSize

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:DATa:SIZe command.

Description
  • This command sets the length of the data string, in bytes, to be used when triggering on a CAN bus signal. The trigger condition must be set to IDANDDATA or DATa (using TRIGGER:A:BUS:BX:CAN:CONDITION). The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:CAN:DATa:SIZe?
Info
  • <NR1> is the length of the data string in bytes.

TriggerABusBItemCanDataValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:DATa:VALue command.

Description
  • This command sets the binary data value to be used when triggering on a CAN bus signal. The trigger condition must be set to IDANDDATA or DATa (using TRIGGER:A:BUS:BX:CAN:CONDITION). The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:CAN:DATa:VALue?
Info
  • <QString> is the data value in binary format. The only allowed characters in the QString are 0, 1, and X.

TriggerABusBItemCanFd

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:FD command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:FD? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:FD? query and raise an AssertionError if the returned value does not match value.
Properties
  • .brsbit: The TRIGger:A:BUS:B<x>:CAN:FD:BRSBIT command.
  • .esibit: The TRIGger:A:BUS:B<x>:CAN:FD:ESIBIT command.

brsbit property

Return the TRIGger:A:BUS:B<x>:CAN:FD:BRSBIT command.

Description
  • This command specifies the binary data value to be used to search on CAN FD BRS bits. This only applies if the search condition has been set to FDBRSBIT (using TRIGger:A:BUS:B<x>:CAN:CONDition ). B is the bus number (1-2).
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:FD:BRSBIT? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:FD:BRSBIT? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:FD:BRSBIT value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:FD:BRSBIT {ZERo|OFF|0|ONE|ON|1|NOCARE|X|x}
- TRIGger:A:BUS:B<x>:CAN:FD:BRSBIT?
Info
  • ZERo , OFF, and 0 specify that the BRS bit must have value 0. If queried, the command will always return 0 if set with these arguments.
  • ONE , ON, and 1 specify that the BRS bit must have value 1. If queried, the command will always return 1 if set with these arguments.
  • NOCARE , X, and x specify that the BRS bit may be either 1 or 0. If queried, the command will always return X if set with these arguments.

esibit property

Return the TRIGger:A:BUS:B<x>:CAN:FD:ESIBIT command.

Description
  • This command specifies the binary data value to be used to search on CAN FD ESI bits. This only applies if the search condition has been set to FDESIBIT (using TRIGger:A:BUS:B<x>:CAN:CONDition ). B is the bus number (1-2).
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:FD:ESIBIT? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:FD:ESIBIT? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:FD:ESIBIT value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:FD:ESIBIT {ZERo|OFF|0|ONE|ON|1|NOCARE|X|x}
- TRIGger:A:BUS:B<x>:CAN:FD:ESIBIT?
Info
  • ZERo , OFF, and 0 specify that the BRS bit must have value 0. If queried, the command will always return 0 if set with these arguments.
  • ONE , ON, and 1 specify that the BRS bit must have value 1. If queried, the command will always return 1 if set with these arguments.
  • NOCARE , X, and x specify that the BRS bit may be either 1 or 0. If queried, the command will always return X if set with these arguments.

TriggerABusBItemCanFdBrsbit

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:FD:BRSBIT command.

Description
  • This command specifies the binary data value to be used to search on CAN FD BRS bits. This only applies if the search condition has been set to FDBRSBIT (using TRIGger:A:BUS:B<x>:CAN:CONDition ). B is the bus number (1-2).
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:FD:BRSBIT? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:FD:BRSBIT? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:FD:BRSBIT value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:FD:BRSBIT {ZERo|OFF|0|ONE|ON|1|NOCARE|X|x}
- TRIGger:A:BUS:B<x>:CAN:FD:BRSBIT?
Info
  • ZERo , OFF, and 0 specify that the BRS bit must have value 0. If queried, the command will always return 0 if set with these arguments.
  • ONE , ON, and 1 specify that the BRS bit must have value 1. If queried, the command will always return 1 if set with these arguments.
  • NOCARE , X, and x specify that the BRS bit may be either 1 or 0. If queried, the command will always return X if set with these arguments.

TriggerABusBItemCanFdEsibit

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:FD:ESIBIT command.

Description
  • This command specifies the binary data value to be used to search on CAN FD ESI bits. This only applies if the search condition has been set to FDESIBIT (using TRIGger:A:BUS:B<x>:CAN:CONDition ). B is the bus number (1-2).
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:FD:ESIBIT? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:FD:ESIBIT? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:FD:ESIBIT value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:FD:ESIBIT {ZERo|OFF|0|ONE|ON|1|NOCARE|X|x}
- TRIGger:A:BUS:B<x>:CAN:FD:ESIBIT?
Info
  • ZERo , OFF, and 0 specify that the BRS bit must have value 0. If queried, the command will always return 0 if set with these arguments.
  • ONE , ON, and 1 specify that the BRS bit must have value 1. If queried, the command will always return 1 if set with these arguments.
  • NOCARE , X, and x specify that the BRS bit may be either 1 or 0. If queried, the command will always return X if set with these arguments.

TriggerABusBItemCanFrametype

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:FRAMEtype command.

Description
  • This command sets the frame type (data, remote, error or overload) to be used when triggering on a CAN bus signal. The trigger condition must be set to FRAMEtype (using TRIGGER:A:BUS:BX:CAN:CONDITION). B is the bus number (1-2).
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:FRAMEtype? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:FRAMEtype? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:FRAMEtype value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:FRAMEtype {DATA|REMote|ERRor|OVERLoad}
- TRIGger:A:BUS:B<x>:CAN:FRAMEtype?
Info
  • DATA specifies a data frame type.
  • REMote specifies a remote frame type.
  • ERRor specifies an error frame type.
  • OVERLold specifies an overload frame type.

TriggerABusBItemCanIdentifier

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:IDentifier command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier? query and raise an AssertionError if the returned value does not match value.
Properties
  • .mode: The TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe command.
  • .value: The TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue command.

mode property

Return the TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe command.

Description
  • This command sets the addressing mode (standard or extended format) to be used when triggering on a CAN bus signal. The trigger condition must be set to IDANDDATA OR DATA (using TRIGGER:A:BUS:BX:CAN:CONDITION). B is the bus number (1-2).
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe {STandard|EXTENDed}
- TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe?
Info
  • STandard specifies the standard addressing mode.
  • EXTENDed specifies the extended addressing mode.

value property

Return the TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue command.

Description
  • This command sets the binary address value to be used when triggering on a CAN bus signal. The trigger condition must be set to IDANDDATA OR DATA (using TRIGGER:A:BUS:BX:CAN:CONDITION). B is the bus number (1-2).
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue <QString>
- TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue?
Info
  • <QString> is up to 29 bits specifying the binary identifier value. The only allowed characters in the QString are 0, 1, and X.

TriggerABusBItemCanIdentifierMode

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe command.

Description
  • This command sets the addressing mode (standard or extended format) to be used when triggering on a CAN bus signal. The trigger condition must be set to IDANDDATA OR DATA (using TRIGGER:A:BUS:BX:CAN:CONDITION). B is the bus number (1-2).
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe {STandard|EXTENDed}
- TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe?
Info
  • STandard specifies the standard addressing mode.
  • EXTENDed specifies the extended addressing mode.

TriggerABusBItemCanIdentifierValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue command.

Description
  • This command sets the binary address value to be used when triggering on a CAN bus signal. The trigger condition must be set to IDANDDATA OR DATA (using TRIGGER:A:BUS:BX:CAN:CONDITION). B is the bus number (1-2).
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue <QString>
- TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue?
Info
  • <QString> is up to 29 bits specifying the binary identifier value. The only allowed characters in the QString are 0, 1, and X.

TriggerABusBItemEthernet

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:ETHERnet command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:ETHERnet? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:ETHERnet? query and raise an AssertionError if the returned value does not match value.
Properties
  • .tcpheader: The TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader command tree.

tcpheader property

Return the TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .destinationport: The TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:DESTinationport command tree.

TriggerABusBItemEthernetTcpheader

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader? query and raise an AssertionError if the returned value does not match value.
Properties
  • .destinationport: The TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:DESTinationport command tree.

destinationport property

Return the TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:DESTinationport command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:DESTinationport? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:DESTinationport? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .value: The TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:DESTinationport:VALue command.

TriggerABusBItemEthernetTcpheaderDestinationport

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:DESTinationport command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:DESTinationport? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:DESTinationport? query and raise an AssertionError if the returned value does not match value.
Properties
  • .value: The TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:DESTinationport:VALue command.

value property

Return the TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:DESTinationport:VALue command.

Description
  • When the Ethernet trigger condition is set TCPHeader, this command specifies the 16-bit destination port address value that is to be used in the trigger (along with the acknowledgement value, source port address and the sequence number). The default is all X’s (don’t care). B is the bus number B1-B4.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:DESTinationport:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:DESTinationport:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:DESTinationport:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:DESTinationport:VALue <QString>
- TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:DESTinationport:VALue?

TriggerABusBItemEthernetTcpheaderDestinationportValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:DESTinationport:VALue command.

Description
  • When the Ethernet trigger condition is set TCPHeader, this command specifies the 16-bit destination port address value that is to be used in the trigger (along with the acknowledgement value, source port address and the sequence number). The default is all X’s (don’t care). B is the bus number B1-B4.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:DESTinationport:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:DESTinationport:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:DESTinationport:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:DESTinationport:VALue <QString>
- TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:DESTinationport:VALue?

TriggerABusBItemFlexray

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray? query and raise an AssertionError if the returned value does not match value.
Properties
  • .condition: The TRIGger:A:BUS:B<x>:FLEXray:CONDition command.
  • .cyclecount: The TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount command tree.
  • .data: The TRIGger:A:BUS:B<x>:FLEXray:DATa command tree.
  • .eoftype: The TRIGger:A:BUS:B<x>:FLEXray:EOFTYPE command.
  • .errtype: The TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE command.
  • .frameid: The TRIGger:A:BUS:B<x>:FLEXray:FRAMEID command tree.
  • .frametype: The TRIGger:A:BUS:B<x>:FLEXray:FRAMEType command.
  • .header: The TRIGger:A:BUS:B<x>:FLEXray:HEADER command tree.

condition property

Return the TRIGger:A:BUS:B<x>:FLEXray:CONDition command.

Description
  • This command specifies the condition to use when triggering on a FlexRay bus signal (start of frame, frame type, ID, cycle count, header, data, ID and data, EOF, error). B is the bus number B1-B2.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:CONDition {SOF|FRAMEType|IDentifier|CYCLEcount|HEADer|DATA|IDANDDATA|EOF|ERROR}
- TRIGger:A:BUS:B<x>:FLEXray:CONDition?
Info
  • SOF sets the trigger condition to start of frame.
  • FRAMEType sets the trigger condition to frame type.
  • IDentifier sets the trigger condition to identifier.
  • CYCLEcount sets the trigger condition to cycle count.
  • HEADer sets the trigger condition to header.
  • DATA sets the trigger condition to data.
  • IDANDDATA sets the trigger condition to id and data.
  • EOF sets the trigger condition to end of frame.
  • ERROR sets the trigger condition to error.

cyclecount property

Return the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .hivalue: The TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:HIVALue command.
  • .qualifier: The TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:QUALifier command.
  • .value: The TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:VALue command.

data property

Return the TRIGger:A:BUS:B<x>:FLEXray:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .hivalue: The TRIGger:A:BUS:B<x>:FLEXray:DATa:HIVALue command.
  • .offset: The TRIGger:A:BUS:B<x>:FLEXray:DATa:OFFSet command.
  • .qualifier: The TRIGger:A:BUS:B<x>:FLEXray:DATa:QUALifier command.
  • .size: The TRIGger:A:BUS:B<x>:FLEXray:DATa:SIZe command.
  • .value: The TRIGger:A:BUS:B<x>:FLEXray:DATa:VALue command.

eoftype property

Return the TRIGger:A:BUS:B<x>:FLEXray:EOFTYPE command.

Description
  • This command specifies the end of file type (static, dynamic or any) when triggering on the FlexRay bus EOF field. The trigger condition needs to be set to EOF (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:EOFTYPE? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:EOFTYPE? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:EOFTYPE value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:EOFTYPE {STATic|DYNAMic|ANY}
- TRIGger:A:BUS:B<x>:FLEXray:EOFTYPE?
Info
  • STATic specifies triggering on the STATIC end of file type.
  • DYNAMic specifies triggering on the DYNAMIC end of file type.
  • ANY specifies triggering on a STATIC or DYNAMIC end of file type.

errtype property

Return the TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE command.

Description
  • This command specifies the error type when triggering on the FlexRay bus signal. The trigger condition needs to be set to ERROR (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE {CRCHeader|CRCTrailer|SYNCFrame|STARTupnosync|NULLFRStatic|NULLFRDynamic}
- TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE?
Info
  • CRCHeader sets the error type to CRCHeader.
  • CRCTrailer sets the error type to CRCTrailer.
  • SYNCFrame sets the error type to SYNCFrame.
  • STARTupnosync sets the error type to STARTupnosync.
  • NULLFRStatic sets the error type to NULLFRStatic.
  • NULLFRDynamic sets the error type to NULLFRDynamic.

frameid property

Return the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .hivalue: The TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIVALue command.
  • .qualifier: The TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:QUALifier command.
  • .value: The TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VALue command.

frametype property

Return the TRIGger:A:BUS:B<x>:FLEXray:FRAMEType command.

Description
  • This command specifies the frame type (normal, payload, null, sync or startup) when triggering on the FlexRay bus signal. The trigger condition needs to be set to FRAMEType (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEType? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEType? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEType value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEType {NORMal|PAYLoad|NULL|SYNC|STARTup}
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEType?
Info
  • NORMal specifies the normal frame type.
  • PAYLoad specifies the payload frame type.
  • NULL specifies the null frame type.
  • SYNC specifies the sync frame type.
  • STARTup specifies the startup frame type.

header property

Return the TRIGger:A:BUS:B<x>:FLEXray:HEADER command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .crc: The TRIGger:A:BUS:B<x>:FLEXray:HEADER:CRC command.
  • .cyclecount: The TRIGger:A:BUS:B<x>:FLEXray:HEADER:CYCLEcount command.
  • .frameid: The TRIGger:A:BUS:B<x>:FLEXray:HEADER:FRAMEID command.
  • .indbits: The TRIGger:A:BUS:B<x>:FLEXray:HEADER:INDBits command.
  • .paylength: The TRIGger:A:BUS:B<x>:FLEXray:HEADER:PAYLength command.

TriggerABusBItemFlexrayCondition

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:CONDition command.

Description
  • This command specifies the condition to use when triggering on a FlexRay bus signal (start of frame, frame type, ID, cycle count, header, data, ID and data, EOF, error). B is the bus number B1-B2.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:CONDition {SOF|FRAMEType|IDentifier|CYCLEcount|HEADer|DATA|IDANDDATA|EOF|ERROR}
- TRIGger:A:BUS:B<x>:FLEXray:CONDition?
Info
  • SOF sets the trigger condition to start of frame.
  • FRAMEType sets the trigger condition to frame type.
  • IDentifier sets the trigger condition to identifier.
  • CYCLEcount sets the trigger condition to cycle count.
  • HEADer sets the trigger condition to header.
  • DATA sets the trigger condition to data.
  • IDANDDATA sets the trigger condition to id and data.
  • EOF sets the trigger condition to end of frame.
  • ERROR sets the trigger condition to error.

TriggerABusBItemFlexrayCyclecount

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount? query and raise an AssertionError if the returned value does not match value.
Properties
  • .hivalue: The TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:HIVALue command.
  • .qualifier: The TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:QUALifier command.
  • .value: The TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:VALue command.

hivalue property

Return the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:HIVALue command.

Description
  • This command specifies the high value when triggering on a FlexRay bus cycle count field. (Use TRIGGER:A:BUS:BX:FLEXRAY:CYCLECOUNT:VALUE to set the low value.) The trigger condition must be set to CYCLEcount (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:HIVALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:HIVALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:HIVALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:HIVALue <QString>
- TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:HIVALue?
Info
  • <QString> is a quoted string that is the cycle count high value.

qualifier property

Return the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:QUALifier command.

Description
  • This command specifies the qualifier (<, >, =, <=, >=, not =, in range, out of range) to use when triggering on the FlexRay bus cycle count field. The trigger condition must be set to CYCLEcount (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:QUALifier {LESSthan|MOREthan|EQual|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:QUALifier?
Info
  • LESSthan sets the cycle count qualifier to less than.
  • MOREthan sets the cycle count qualifier to more than.
  • EQual sets the cycle count qualifier to equal.
  • UNEQual sets the cycle count qualifier to not equal.
  • LESSEQual sets the cycle count qualifier to less than or equal.
  • MOREEQual sets the cycle count qualifier to greater than or equal.
  • INrange sets the cycle count qualifier to in range.
  • OUTrange sets the cycle count qualifier to out of range.

value property

Return the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:VALue command.

Description
  • This command specifies the low value when triggering on the FlexRay bus cycle count field. (Use TRIGGER:A:BUS:BX:FLEXRAY:CYCLECOUNT:HIVALUE to set the upper value.) The trigger condition must be set to CYCLEcount (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:VALue <QString>
- TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:VALue?
Info
  • <QString> is a quoted binary data string that represents the cycle count low value.

TriggerABusBItemFlexrayCyclecountHivalue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:HIVALue command.

Description
  • This command specifies the high value when triggering on a FlexRay bus cycle count field. (Use TRIGGER:A:BUS:BX:FLEXRAY:CYCLECOUNT:VALUE to set the low value.) The trigger condition must be set to CYCLEcount (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:HIVALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:HIVALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:HIVALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:HIVALue <QString>
- TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:HIVALue?
Info
  • <QString> is a quoted string that is the cycle count high value.

TriggerABusBItemFlexrayCyclecountQualifier

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:QUALifier command.

Description
  • This command specifies the qualifier (<, >, =, <=, >=, not =, in range, out of range) to use when triggering on the FlexRay bus cycle count field. The trigger condition must be set to CYCLEcount (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:QUALifier {LESSthan|MOREthan|EQual|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:QUALifier?
Info
  • LESSthan sets the cycle count qualifier to less than.
  • MOREthan sets the cycle count qualifier to more than.
  • EQual sets the cycle count qualifier to equal.
  • UNEQual sets the cycle count qualifier to not equal.
  • LESSEQual sets the cycle count qualifier to less than or equal.
  • MOREEQual sets the cycle count qualifier to greater than or equal.
  • INrange sets the cycle count qualifier to in range.
  • OUTrange sets the cycle count qualifier to out of range.

TriggerABusBItemFlexrayCyclecountValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:VALue command.

Description
  • This command specifies the low value when triggering on the FlexRay bus cycle count field. (Use TRIGGER:A:BUS:BX:FLEXRAY:CYCLECOUNT:HIVALUE to set the upper value.) The trigger condition must be set to CYCLEcount (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:VALue <QString>
- TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:VALue?
Info
  • <QString> is a quoted binary data string that represents the cycle count low value.

TriggerABusBItemFlexrayData

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa? query and raise an AssertionError if the returned value does not match value.
Properties
  • .hivalue: The TRIGger:A:BUS:B<x>:FLEXray:DATa:HIVALue command.
  • .offset: The TRIGger:A:BUS:B<x>:FLEXray:DATa:OFFSet command.
  • .qualifier: The TRIGger:A:BUS:B<x>:FLEXray:DATa:QUALifier command.
  • .size: The TRIGger:A:BUS:B<x>:FLEXray:DATa:SIZe command.
  • .value: The TRIGger:A:BUS:B<x>:FLEXray:DATa:VALue command.

hivalue property

Return the TRIGger:A:BUS:B<x>:FLEXray:DATa:HIVALue command.

Description
  • This command specifies the high value when triggering on the FlexRay bus data field. (Use TRIGGER:A:BUS:BX:FLEXRAY:DATA:VALUE to set the lower value.) The trigger condition needs to be set to ID or IDANDDATA (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:HIVALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:HIVALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:HIVALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:DATa:HIVALue <QString>
- TRIGger:A:BUS:B<x>:FLEXray:DATa:HIVALue?
Info
  • <QString> is a quoted string that is the binary data high value.

offset property

Return the TRIGger:A:BUS:B<x>:FLEXray:DATa:OFFSet command.

Description
  • This command specifies the offset of the data string, in bytes, when triggering on the FlexRay bus data field. The trigger condition needs to be set to ID or IDANDDATA (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:OFFSet? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:OFFSet? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:OFFSet value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:DATa:OFFSet <NR1>
- TRIGger:A:BUS:B<x>:FLEXray:DATa:OFFSet?
Info
  • <NR1> is the offset of the data string in bytes. A byte offset of -1 signifies ‘don’t care’, and no byte offset is used. The instrument will trigger on or match any byte value that fits.

qualifier property

Return the TRIGger:A:BUS:B<x>:FLEXray:DATa:QUALifier command.

Description
  • This command specifies the qualifier (<, >, =, <=, >=, not =, in range, out of range) to use when triggering on the FlexRay bus data field. The trigger condition needs to be set to ID or IDANDDATA (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:DATa:QUALifier {LESSthan|MOREthan|EQual|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:FLEXray:DATa:QUALifier?
Info
  • LESSthan sets the data qualifier to less than.
  • MOREthan sets the data qualifier to greater than.
  • EQual sets the data qualifier to eqaual.
  • UNEQual sets the data qualifier to not equal.
  • LESSEQual sets the data qualifier to less than or equal.
  • MOREEQual sets the data qualifier to greater than or equal.
  • INrange sets the data qualifier to in range.
  • OUTrange sets the data qualifier to out of range.

size property

Return the TRIGger:A:BUS:B<x>:FLEXray:DATa:SIZe command.

Description
  • This command specifies the length of the data string, in bytes, when triggering on the FlexRay bus data field. The trigger condition needs to be set to ID or IDANDDATA (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:FLEXray:DATa:SIZe?
Info
  • <NR1> is the FlexRay data string length, in bytes.

value property

Return the TRIGger:A:BUS:B<x>:FLEXray:DATa:VALue command.

Description
  • This command specifies the low value when triggering on the FlexRay bus data field. (Use TRIGGER:A:BUS:BX:FLEXRAY:DATA:HIVALUE to set the upper value.) The trigger condition needs to be set to ID or IDANDDATA (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:FLEXray:DATa:VALue?
Info
  • <QString> is a quoted string.

TriggerABusBItemFlexrayDataHivalue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:DATa:HIVALue command.

Description
  • This command specifies the high value when triggering on the FlexRay bus data field. (Use TRIGGER:A:BUS:BX:FLEXRAY:DATA:VALUE to set the lower value.) The trigger condition needs to be set to ID or IDANDDATA (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:HIVALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:HIVALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:HIVALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:DATa:HIVALue <QString>
- TRIGger:A:BUS:B<x>:FLEXray:DATa:HIVALue?
Info
  • <QString> is a quoted string that is the binary data high value.

TriggerABusBItemFlexrayDataOffset

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:DATa:OFFSet command.

Description
  • This command specifies the offset of the data string, in bytes, when triggering on the FlexRay bus data field. The trigger condition needs to be set to ID or IDANDDATA (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:OFFSet? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:OFFSet? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:OFFSet value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:DATa:OFFSet <NR1>
- TRIGger:A:BUS:B<x>:FLEXray:DATa:OFFSet?
Info
  • <NR1> is the offset of the data string in bytes. A byte offset of -1 signifies ‘don’t care’, and no byte offset is used. The instrument will trigger on or match any byte value that fits.

TriggerABusBItemFlexrayDataQualifier

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:DATa:QUALifier command.

Description
  • This command specifies the qualifier (<, >, =, <=, >=, not =, in range, out of range) to use when triggering on the FlexRay bus data field. The trigger condition needs to be set to ID or IDANDDATA (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:DATa:QUALifier {LESSthan|MOREthan|EQual|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:FLEXray:DATa:QUALifier?
Info
  • LESSthan sets the data qualifier to less than.
  • MOREthan sets the data qualifier to greater than.
  • EQual sets the data qualifier to eqaual.
  • UNEQual sets the data qualifier to not equal.
  • LESSEQual sets the data qualifier to less than or equal.
  • MOREEQual sets the data qualifier to greater than or equal.
  • INrange sets the data qualifier to in range.
  • OUTrange sets the data qualifier to out of range.

TriggerABusBItemFlexrayDataSize

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:DATa:SIZe command.

Description
  • This command specifies the length of the data string, in bytes, when triggering on the FlexRay bus data field. The trigger condition needs to be set to ID or IDANDDATA (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:FLEXray:DATa:SIZe?
Info
  • <NR1> is the FlexRay data string length, in bytes.

TriggerABusBItemFlexrayDataValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:DATa:VALue command.

Description
  • This command specifies the low value when triggering on the FlexRay bus data field. (Use TRIGGER:A:BUS:BX:FLEXRAY:DATA:HIVALUE to set the upper value.) The trigger condition needs to be set to ID or IDANDDATA (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:FLEXray:DATa:VALue?
Info
  • <QString> is a quoted string.

TriggerABusBItemFlexrayEoftype

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:EOFTYPE command.

Description
  • This command specifies the end of file type (static, dynamic or any) when triggering on the FlexRay bus EOF field. The trigger condition needs to be set to EOF (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:EOFTYPE? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:EOFTYPE? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:EOFTYPE value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:EOFTYPE {STATic|DYNAMic|ANY}
- TRIGger:A:BUS:B<x>:FLEXray:EOFTYPE?
Info
  • STATic specifies triggering on the STATIC end of file type.
  • DYNAMic specifies triggering on the DYNAMIC end of file type.
  • ANY specifies triggering on a STATIC or DYNAMIC end of file type.

TriggerABusBItemFlexrayErrtype

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE command.

Description
  • This command specifies the error type when triggering on the FlexRay bus signal. The trigger condition needs to be set to ERROR (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE {CRCHeader|CRCTrailer|SYNCFrame|STARTupnosync|NULLFRStatic|NULLFRDynamic}
- TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE?
Info
  • CRCHeader sets the error type to CRCHeader.
  • CRCTrailer sets the error type to CRCTrailer.
  • SYNCFrame sets the error type to SYNCFrame.
  • STARTupnosync sets the error type to STARTupnosync.
  • NULLFRStatic sets the error type to NULLFRStatic.
  • NULLFRDynamic sets the error type to NULLFRDynamic.

TriggerABusBItemFlexrayFrameid

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:FRAMEID command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID? query and raise an AssertionError if the returned value does not match value.
Properties
  • .hivalue: The TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIVALue command.
  • .qualifier: The TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:QUALifier command.
  • .value: The TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VALue command.

hivalue property

Return the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIVALue command.

Description
  • This command specifies the high value when triggering on the FlexRay bus frame ID field. (Use TRIGGER:A:BUS:BX:FLEXRAY:FRAMEID:VALUE to set the low value.) The trigger condition needs to be set to IDentifier (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIVALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIVALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIVALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIVALue <QString>
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIVALue?
Info
  • <QString> is a quoted string that is the binary frame ID high value.

qualifier property

Return the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:QUALifier command.

Description
  • This command specifies the qualifier to use when triggering on the FlexRay bus frame ID field. The trigger condition needs to be set to IDentifier (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:QUALifier {LESSthan|MOREthan|EQual|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:QUALifier?
Info
  • LESSthan sets the frame ID qualifier to less than.
  • MOREthan sets the frame ID qualifier to greater than.
  • EQual sets the frame ID qualifier to equal.
  • UNEQual sets the frame ID qualifier to not equal.
  • LESSEQual sets the frame ID qualifier to less than or equal.
  • MOREEQual sets the frame ID qualifier to greater than or equal.
  • INrange sets the frame ID qualifier to in range.
  • OUTrange sets the frame ID qualifier to out of range.

value property

Return the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VALue command.

Description
  • This command specifies the low value when triggering on the FlexRay bus frame ID field. (Use TRIGGER:A:BUS:BX:FLEXRAY:FRAMEID:HIVALUE to set the high value.) The trigger condition needs to be set to IDentifier (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VALue <QString>
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VALue?
Info
  • <QString> is a quoted string that is the FlexRay frame ID low value.

TriggerABusBItemFlexrayFrameidHivalue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIVALue command.

Description
  • This command specifies the high value when triggering on the FlexRay bus frame ID field. (Use TRIGGER:A:BUS:BX:FLEXRAY:FRAMEID:VALUE to set the low value.) The trigger condition needs to be set to IDentifier (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIVALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIVALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIVALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIVALue <QString>
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIVALue?
Info
  • <QString> is a quoted string that is the binary frame ID high value.

TriggerABusBItemFlexrayFrameidQualifier

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:QUALifier command.

Description
  • This command specifies the qualifier to use when triggering on the FlexRay bus frame ID field. The trigger condition needs to be set to IDentifier (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:QUALifier {LESSthan|MOREthan|EQual|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:QUALifier?
Info
  • LESSthan sets the frame ID qualifier to less than.
  • MOREthan sets the frame ID qualifier to greater than.
  • EQual sets the frame ID qualifier to equal.
  • UNEQual sets the frame ID qualifier to not equal.
  • LESSEQual sets the frame ID qualifier to less than or equal.
  • MOREEQual sets the frame ID qualifier to greater than or equal.
  • INrange sets the frame ID qualifier to in range.
  • OUTrange sets the frame ID qualifier to out of range.

TriggerABusBItemFlexrayFrameidValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VALue command.

Description
  • This command specifies the low value when triggering on the FlexRay bus frame ID field. (Use TRIGGER:A:BUS:BX:FLEXRAY:FRAMEID:HIVALUE to set the high value.) The trigger condition needs to be set to IDentifier (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VALue <QString>
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VALue?
Info
  • <QString> is a quoted string that is the FlexRay frame ID low value.

TriggerABusBItemFlexrayFrametype

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:FRAMEType command.

Description
  • This command specifies the frame type (normal, payload, null, sync or startup) when triggering on the FlexRay bus signal. The trigger condition needs to be set to FRAMEType (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEType? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEType? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEType value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEType {NORMal|PAYLoad|NULL|SYNC|STARTup}
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEType?
Info
  • NORMal specifies the normal frame type.
  • PAYLoad specifies the payload frame type.
  • NULL specifies the null frame type.
  • SYNC specifies the sync frame type.
  • STARTup specifies the startup frame type.

TriggerABusBItemFlexrayHeader

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:HEADER command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER? query and raise an AssertionError if the returned value does not match value.
Properties
  • .crc: The TRIGger:A:BUS:B<x>:FLEXray:HEADER:CRC command.
  • .cyclecount: The TRIGger:A:BUS:B<x>:FLEXray:HEADER:CYCLEcount command.
  • .frameid: The TRIGger:A:BUS:B<x>:FLEXray:HEADER:FRAMEID command.
  • .indbits: The TRIGger:A:BUS:B<x>:FLEXray:HEADER:INDBits command.
  • .paylength: The TRIGger:A:BUS:B<x>:FLEXray:HEADER:PAYLength command.

crc property

Return the TRIGger:A:BUS:B<x>:FLEXray:HEADER:CRC command.

Description
  • This command specifies the CRC portion of the binary header string when triggering on the FlexRay bus signal. The trigger condition needs to be set to HEADer (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:CRC? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:CRC? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:CRC value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:CRC <QString>
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:CRC?
Info
  • <QString> is a quoted string that is the CRC portion of the binary header string.

cyclecount property

Return the TRIGger:A:BUS:B<x>:FLEXray:HEADER:CYCLEcount command.

Description
  • This command specifies the cycle count portion of the binary header string when triggering on the FlexRay bus header. The trigger condition needs to be set to HEADer (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:CYCLEcount? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:CYCLEcount? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:CYCLEcount value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:CYCLEcount <QString>
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:CYCLEcount?
Info
  • <QString> is a quoted string that is the cycle count portion of the binary header string.

frameid property

Return the TRIGger:A:BUS:B<x>:FLEXray:HEADER:FRAMEID command.

Description
  • This command specifies the frame ID portion of the binary header string when triggering on the FlexRay bus header. The trigger condition needs to be set to HEADer (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:FRAMEID? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:FRAMEID? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:FRAMEID value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:FRAMEID <QString>
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:FRAMEID?
Info
  • <QString> is a quoted string that represents the frame ID portion of the binary header string.

indbits property

Return the TRIGger:A:BUS:B<x>:FLEXray:HEADER:INDBits command.

Description
  • This command specifies the indicator bits portion of the binary header string when triggering on the FlexRay bus header. The trigger condition needs to be set to HEADer (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:INDBits? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:INDBits? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:INDBits value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:INDBits <QString>
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:INDBits?
Info
  • <QString> is a quoted string that is the indicator bits portion of the binary header string.

paylength property

Return the TRIGger:A:BUS:B<x>:FLEXray:HEADER:PAYLength command.

Description
  • This command specifies the payload length portion of the binary header string when triggering on the FlexRay bus header. The trigger condition needs to be set to HEADer (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:PAYLength? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:PAYLength? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:PAYLength value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:PAYLength <QString>
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:PAYLength?
Info
  • <QString> is the length of the payload portion of the Binary header string.

TriggerABusBItemFlexrayHeaderCrc

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:HEADER:CRC command.

Description
  • This command specifies the CRC portion of the binary header string when triggering on the FlexRay bus signal. The trigger condition needs to be set to HEADer (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:CRC? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:CRC? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:CRC value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:CRC <QString>
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:CRC?
Info
  • <QString> is a quoted string that is the CRC portion of the binary header string.

TriggerABusBItemFlexrayHeaderCyclecount

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:HEADER:CYCLEcount command.

Description
  • This command specifies the cycle count portion of the binary header string when triggering on the FlexRay bus header. The trigger condition needs to be set to HEADer (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:CYCLEcount? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:CYCLEcount? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:CYCLEcount value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:CYCLEcount <QString>
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:CYCLEcount?
Info
  • <QString> is a quoted string that is the cycle count portion of the binary header string.

TriggerABusBItemFlexrayHeaderFrameid

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:HEADER:FRAMEID command.

Description
  • This command specifies the frame ID portion of the binary header string when triggering on the FlexRay bus header. The trigger condition needs to be set to HEADer (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:FRAMEID? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:FRAMEID? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:FRAMEID value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:FRAMEID <QString>
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:FRAMEID?
Info
  • <QString> is a quoted string that represents the frame ID portion of the binary header string.

TriggerABusBItemFlexrayHeaderIndbits

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:HEADER:INDBits command.

Description
  • This command specifies the indicator bits portion of the binary header string when triggering on the FlexRay bus header. The trigger condition needs to be set to HEADer (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:INDBits? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:INDBits? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:INDBits value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:INDBits <QString>
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:INDBits?
Info
  • <QString> is a quoted string that is the indicator bits portion of the binary header string.

TriggerABusBItemFlexrayHeaderPaylength

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:HEADER:PAYLength command.

Description
  • This command specifies the payload length portion of the binary header string when triggering on the FlexRay bus header. The trigger condition needs to be set to HEADer (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:PAYLength? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:PAYLength? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:PAYLength value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:PAYLength <QString>
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:PAYLength?
Info
  • <QString> is the length of the payload portion of the Binary header string.

TriggerABusBItemI2c

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:I2C command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C? query and raise an AssertionError if the returned value does not match value.
Properties
  • .address: The TRIGger:A:BUS:B<x>:I2C:ADDRess command tree.
  • .condition: The TRIGger:A:BUS:B<x>:I2C:CONDition command.
  • .data: The TRIGger:A:BUS:B<x>:I2C:DATa command tree.

address property

Return the TRIGger:A:BUS:B<x>:I2C:ADDRess command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .mode: The TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe command.
  • .type: The TRIGger:A:BUS:B<x>:I2C:ADDRess:TYPe command.
  • .value: The TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue command.

condition property

Return the TRIGger:A:BUS:B<x>:I2C:CONDition command.

Description
  • This command specifies the trigger condition for an I 2 C trigger. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:CONDition {STARt|STOP|REPEATstart|ACKMISS|ADDRess|DATA|ADDRANDDATA}
- TRIGger:A:BUS:B<x>:I2C:CONDition?
Info
  • STARt specifies a search based on start condition.
  • STOP specifies a search based on stop condition.
  • REPEATstart specifies a search based on repeat of start condition.
  • ACKMISS specifies a search based on missing acknowledgement condition.
  • ADDRess specifies a search based on address.
  • DATA specifies a search based on data.
  • ADDRANDDATA specifies a search based on address and data.

data property

Return the TRIGger:A:BUS:B<x>:I2C:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .direction: The TRIGger:A:BUS:B<x>:I2C:DATa:DIRection command.
  • .size: The TRIGger:A:BUS:B<x>:I2C:DATa:SIZe command.
  • .value: The TRIGger:A:BUS:B<x>:I2C:DATa:VALue command.

TriggerABusBItemI2cAddress

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:I2C:ADDRess command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess? query and raise an AssertionError if the returned value does not match value.
Properties
  • .mode: The TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe command.
  • .type: The TRIGger:A:BUS:B<x>:I2C:ADDRess:TYPe command.
  • .value: The TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue command.

mode property

Return the TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe command.

Description
  • This command specifies the I 2 C address mode to 7 or 10-bit. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe {ADDR7|ADDR10}
- TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe?
Info
  • ADDR7 specifies the 7-bit I2C address mode.
  • ADDR10 specifies the 10-bit I2C address mode.

type property

Return the TRIGger:A:BUS:B<x>:I2C:ADDRess:TYPe command.

Description
  • This command specifies the I 2 C address type. The only supported address type is USER. Applies to bus , where x
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:TYPe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:TYPe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:TYPe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:ADDRess:TYPe {GENeralcall|STARtbyte|HSmode|EEPROM|USER}
- TRIGger:A:BUS:B<x>:I2C:ADDRess:TYPe?
Info
  • GENeralcall specifies a general call address.
  • STARtbyte specifies a start byte address.
  • HSmode specifies a high-speed mode address.
  • EEPROM specifies an EEPROM address.
  • USER specifies a user address.

value property

Return the TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue command.

Description
  • This command specifies the binary address string used for the I 2 C trigger if the trigger condition is ADDRESS or ADDRANDDATA. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue <QString>
- TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue?
Info
  • <QString> is up to 7 or 10-bits depending on the address mode that specifies the address. The only allowed characters in the QString are 0, 1, and X.

TriggerABusBItemI2cAddressMode

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe command.

Description
  • This command specifies the I 2 C address mode to 7 or 10-bit. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe {ADDR7|ADDR10}
- TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe?
Info
  • ADDR7 specifies the 7-bit I2C address mode.
  • ADDR10 specifies the 10-bit I2C address mode.

TriggerABusBItemI2cAddressType

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:I2C:ADDRess:TYPe command.

Description
  • This command specifies the I 2 C address type. The only supported address type is USER. Applies to bus , where x
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:TYPe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:TYPe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:TYPe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:ADDRess:TYPe {GENeralcall|STARtbyte|HSmode|EEPROM|USER}
- TRIGger:A:BUS:B<x>:I2C:ADDRess:TYPe?
Info
  • GENeralcall specifies a general call address.
  • STARtbyte specifies a start byte address.
  • HSmode specifies a high-speed mode address.
  • EEPROM specifies an EEPROM address.
  • USER specifies a user address.

TriggerABusBItemI2cAddressValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue command.

Description
  • This command specifies the binary address string used for the I 2 C trigger if the trigger condition is ADDRESS or ADDRANDDATA. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue <QString>
- TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue?
Info
  • <QString> is up to 7 or 10-bits depending on the address mode that specifies the address. The only allowed characters in the QString are 0, 1, and X.

TriggerABusBItemI2cCondition

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:I2C:CONDition command.

Description
  • This command specifies the trigger condition for an I 2 C trigger. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:CONDition {STARt|STOP|REPEATstart|ACKMISS|ADDRess|DATA|ADDRANDDATA}
- TRIGger:A:BUS:B<x>:I2C:CONDition?
Info
  • STARt specifies a search based on start condition.
  • STOP specifies a search based on stop condition.
  • REPEATstart specifies a search based on repeat of start condition.
  • ACKMISS specifies a search based on missing acknowledgement condition.
  • ADDRess specifies a search based on address.
  • DATA specifies a search based on data.
  • ADDRANDDATA specifies a search based on address and data.

TriggerABusBItemI2cData

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:I2C:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa? query and raise an AssertionError if the returned value does not match value.
Properties
  • .direction: The TRIGger:A:BUS:B<x>:I2C:DATa:DIRection command.
  • .size: The TRIGger:A:BUS:B<x>:I2C:DATa:SIZe command.
  • .value: The TRIGger:A:BUS:B<x>:I2C:DATa:VALue command.

direction property

Return the TRIGger:A:BUS:B<x>:I2C:DATa:DIRection command.

Description
  • This command specifies the I 2 C trigger type to be valid on a Read, Write, or Either condition. Read or write is indicated by the R/W bit in the I 2 C protocol. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:DATa:DIRection? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa:DIRection? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa:DIRection value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:DATa:DIRection {READ|WRITE|NOCARE}
- TRIGger:A:BUS:B<x>:I2C:DATa:DIRection?
Info
  • READ specifies read as the data direction.
  • WRITE specifies write as the data direction.
  • NOCARE specifies either as the data direction.

size property

Return the TRIGger:A:BUS:B<x>:I2C:DATa:SIZe command.

Description
  • This command specifies the length of the data string in bytes to be used for an I2C trigger if the trigger condition is DATA or ADDRANDDATA. Applies to bus , where the bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:I2C:DATa:SIZe?
Info
  • <NR1> is the length of the data string in bytes.

value property

Return the TRIGger:A:BUS:B<x>:I2C:DATa:VALue command.

Description
  • This command specifies the binary data string used for I2C triggering if the trigger condition is DATA or ADDRANDDATA. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:I2C:DATa:VALue?
Info
  • <QString> is the binary data string, where the number of bits is 8 times the number of bytes specified. The only allowed characters in the string are 0, 1, and X.

TriggerABusBItemI2cDataDirection

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:I2C:DATa:DIRection command.

Description
  • This command specifies the I 2 C trigger type to be valid on a Read, Write, or Either condition. Read or write is indicated by the R/W bit in the I 2 C protocol. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:DATa:DIRection? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa:DIRection? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa:DIRection value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:DATa:DIRection {READ|WRITE|NOCARE}
- TRIGger:A:BUS:B<x>:I2C:DATa:DIRection?
Info
  • READ specifies read as the data direction.
  • WRITE specifies write as the data direction.
  • NOCARE specifies either as the data direction.

TriggerABusBItemI2cDataSize

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:I2C:DATa:SIZe command.

Description
  • This command specifies the length of the data string in bytes to be used for an I2C trigger if the trigger condition is DATA or ADDRANDDATA. Applies to bus , where the bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:I2C:DATa:SIZe?
Info
  • <NR1> is the length of the data string in bytes.

TriggerABusBItemI2cDataValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:I2C:DATa:VALue command.

Description
  • This command specifies the binary data string used for I2C triggering if the trigger condition is DATA or ADDRANDDATA. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:I2C:DATa:VALue?
Info
  • <QString> is the binary data string, where the number of bits is 8 times the number of bytes specified. The only allowed characters in the string are 0, 1, and X.

TriggerABusBItemLin

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:LIN command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN? query and raise an AssertionError if the returned value does not match value.
Properties
  • .condition: The TRIGger:A:BUS:B<x>:LIN:CONDition command.
  • .data: The TRIGger:A:BUS:B<x>:LIN:DATa command tree.
  • .errtype: The TRIGger:A:BUS:B<x>:LIN:ERRTYPE command.
  • .identifier: The TRIGger:A:BUS:B<x>:LIN:IDentifier command tree.

condition property

Return the TRIGger:A:BUS:B<x>:LIN:CONDition command.

Description
  • This command specifies the trigger condition for LIN. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:CONDition {SYNCField|IDentifier|DATA|IDANDDATA|WAKEup|SLEEP|ERROR}
- TRIGger:A:BUS:B<x>:LIN:CONDition?
Info
  • SYNCField sets the LIN trigger condition to sync field.
  • IDentifier sets the LIN trigger condition to identifier.
  • DATA sets the LIN trigger condition to data.
  • IDANDDATA sets the LIN trigger condition to id and data.
  • WAKEup sets the LIN trigger condition to wake up.
  • SLEEP sets the LIN trigger condition to sleep.
  • ERROR sets the LIN trigger condition to error.

data property

Return the TRIGger:A:BUS:B<x>:LIN:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .hivalue: The TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue command.
  • .qualifier: The TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier command.
  • .size: The TRIGger:A:BUS:B<x>:LIN:DATa:SIZe command.
  • .value: The TRIGger:A:BUS:B<x>:LIN:DATa:VALue command.

errtype property

Return the TRIGger:A:BUS:B<x>:LIN:ERRTYPE command.

Description
  • This command specifies the error type be used for LIN trigger. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:ERRTYPE? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:ERRTYPE? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:ERRTYPE value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:ERRTYPE {SYNC|PARity|CHecksum|HEADertime|RESPtime|FRAMetime}
- TRIGger:A:BUS:B<x>:LIN:ERRTYPE?
Info
  • SYNC sets the LIN error type to SYNC.
  • PARity sets the LIN error type to parity.
  • CHecksum sets the LIN error type to checksum.
  • HEADertime sets the LIN error type to header time.
  • RESPtime sets the LIN error type to response time.
  • FRAMetime sets the LIN error type to frame time.

identifier property

Return the TRIGger:A:BUS:B<x>:LIN:IDentifier command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:IDentifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:IDentifier? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .value: The TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue command.

TriggerABusBItemLinCondition

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:LIN:CONDition command.

Description
  • This command specifies the trigger condition for LIN. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:CONDition {SYNCField|IDentifier|DATA|IDANDDATA|WAKEup|SLEEP|ERROR}
- TRIGger:A:BUS:B<x>:LIN:CONDition?
Info
  • SYNCField sets the LIN trigger condition to sync field.
  • IDentifier sets the LIN trigger condition to identifier.
  • DATA sets the LIN trigger condition to data.
  • IDANDDATA sets the LIN trigger condition to id and data.
  • WAKEup sets the LIN trigger condition to wake up.
  • SLEEP sets the LIN trigger condition to sleep.
  • ERROR sets the LIN trigger condition to error.

TriggerABusBItemLinData

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:LIN:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa? query and raise an AssertionError if the returned value does not match value.
Properties
  • .hivalue: The TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue command.
  • .qualifier: The TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier command.
  • .size: The TRIGger:A:BUS:B<x>:LIN:DATa:SIZe command.
  • .value: The TRIGger:A:BUS:B<x>:LIN:DATa:VALue command.

hivalue property

Return the TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue command.

Description
  • This command specifies the high data value string used for a LIN bus trigger when the trigger condition is DATA or IDANDDATA and the data qualifier is INRANGE or OUTRANGE. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue <QString>
- TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue?
Info
  • <QString> is a quoted string that is the binary data string used for LIN trigger if the trigger condition is ID or IDANDDATA.

qualifier property

Return the TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier command.

Description
  • This command specifies the LIN data qualifier. This only applies if the trigger condition is IDANDDATA or DATA. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier {LESSthan|MOREthan|EQual|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier?
Info
  • LESSthan sets the LIN data qualifier to less than.
  • MOREthan sets the LIN data qualifier to greater than.
  • EQual sets the LIN data qualifier to equal.
  • UNEQual sets the LIN data qualifier to not equal.
  • LESSEQual sets the LIN data qualifier to less than or equal.
  • MOREEQual sets the LIN data qualifier to greater than or equal.
  • INrange sets the LIN data qualifier to in range.
  • OUTrange sets the LIN data qualifier to out of range.

size property

Return the TRIGger:A:BUS:B<x>:LIN:DATa:SIZe command.

Description
  • This command specifies the length of the data string in bytes to be used for LIN trigger. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:LIN:DATa:SIZe?
Info
  • <NR1> is the size of the data string in bytes.

value property

Return the TRIGger:A:BUS:B<x>:LIN:DATa:VALue command.

Description
  • This command specifies the binary data string to be used for LIN trigger condition if trigger condition is ID or IDANDDATA. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:LIN:DATa:VALue?
Info
  • <QString> is a quoted string that is the LIN trigger data value.

TriggerABusBItemLinDataHivalue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue command.

Description
  • This command specifies the high data value string used for a LIN bus trigger when the trigger condition is DATA or IDANDDATA and the data qualifier is INRANGE or OUTRANGE. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue <QString>
- TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue?
Info
  • <QString> is a quoted string that is the binary data string used for LIN trigger if the trigger condition is ID or IDANDDATA.

TriggerABusBItemLinDataQualifier

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier command.

Description
  • This command specifies the LIN data qualifier. This only applies if the trigger condition is IDANDDATA or DATA. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier {LESSthan|MOREthan|EQual|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier?
Info
  • LESSthan sets the LIN data qualifier to less than.
  • MOREthan sets the LIN data qualifier to greater than.
  • EQual sets the LIN data qualifier to equal.
  • UNEQual sets the LIN data qualifier to not equal.
  • LESSEQual sets the LIN data qualifier to less than or equal.
  • MOREEQual sets the LIN data qualifier to greater than or equal.
  • INrange sets the LIN data qualifier to in range.
  • OUTrange sets the LIN data qualifier to out of range.

TriggerABusBItemLinDataSize

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:LIN:DATa:SIZe command.

Description
  • This command specifies the length of the data string in bytes to be used for LIN trigger. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:LIN:DATa:SIZe?
Info
  • <NR1> is the size of the data string in bytes.

TriggerABusBItemLinDataValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:LIN:DATa:VALue command.

Description
  • This command specifies the binary data string to be used for LIN trigger condition if trigger condition is ID or IDANDDATA. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:LIN:DATa:VALue?
Info
  • <QString> is a quoted string that is the LIN trigger data value.

TriggerABusBItemLinErrtype

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:LIN:ERRTYPE command.

Description
  • This command specifies the error type be used for LIN trigger. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:ERRTYPE? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:ERRTYPE? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:ERRTYPE value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:ERRTYPE {SYNC|PARity|CHecksum|HEADertime|RESPtime|FRAMetime}
- TRIGger:A:BUS:B<x>:LIN:ERRTYPE?
Info
  • SYNC sets the LIN error type to SYNC.
  • PARity sets the LIN error type to parity.
  • CHecksum sets the LIN error type to checksum.
  • HEADertime sets the LIN error type to header time.
  • RESPtime sets the LIN error type to response time.
  • FRAMetime sets the LIN error type to frame time.

TriggerABusBItemLinIdentifier

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:LIN:IDentifier command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:IDentifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:IDentifier? query and raise an AssertionError if the returned value does not match value.
Properties
  • .value: The TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue command.

value property

Return the TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue command.

Description
  • This command specifies the binary address string used for LIN bus trigger if the trigger condition is ID or IDANDDATA. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue <QString>
- TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue?
Info
  • <QString> is the binary address string used for LIN trigger if the trigger condition is ID or IDANDDATA.

TriggerABusBItemLinIdentifierValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue command.

Description
  • This command specifies the binary address string used for LIN bus trigger if the trigger condition is ID or IDANDDATA. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue <QString>
- TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue?
Info
  • <QString> is the binary address string used for LIN trigger if the trigger condition is ID or IDANDDATA.

TriggerABusBItemMil1553b

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:MIL1553B command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B? query and raise an AssertionError if the returned value does not match value.
Properties
  • .command: The TRIGger:A:BUS:B<x>:MIL1553B:COMMAND command tree.
  • .condition: The TRIGger:A:BUS:B<x>:MIL1553B:CONDition command.
  • .data: The TRIGger:A:BUS:B<x>:MIL1553B:DATa command tree.
  • .errtype: The TRIGger:A:BUS:B<x>:MIL1553B:ERRTYPE command.
  • .status: The TRIGger:A:BUS:B<x>:MIL1553B:STATus command tree.
  • .time: The TRIGger:A:BUS:B<x>:MIL1553B:TIMe command tree.

command property

Return the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .address: The TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess command tree.
  • .count: The TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:COUNt command.
  • .parity: The TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:PARity command.
  • .subaddress: The TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:SUBADdress command.
  • .trbit: The TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:TRBit command.

condition property

Return the TRIGger:A:BUS:B<x>:MIL1553B:CONDition command.

Description
  • This command specifies a word type or condition within a MIL-STD-1553 bus word to trigger on. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:CONDition {SYNC|COMMAND|STATus|DATA|TIMe|ERRor}
- TRIGger:A:BUS:B<x>:MIL1553B:CONDition?
Info
  • SYNC refers to the 3-bit sync pulse that precedes each word.
  • COMMAND is one of 3 16-bit word types. It specifies the function that a remote terminal is to perform.
  • STATus is one of 3 16-bit word types. Remote terminals respond to valid message transmissions via status words.
  • DATA is one of 3 16-bit word types.
  • TIMe specifies to trigger on either the RT (remote terminal response time), or the IMG (Inter-message Gap). Use the commands TRIGGER:A:BUS:BX:MIL1553B:TIME:QUALIFIER, TRIGGER:A:BUS:BX:MIL1553B:TIME:LESSLIMIT, and TRIGGER:A:BUS:BX:MIL1553B:TIME:MORELIMIT to specify the time parameters.
  • ERRor specifies to trigger upon a signaling error. (You can specify which type of error - Parity, Sync, Manchester or Non-contiguous Data - by using the TRIGGER:A:BUS:BX:MIL1553B:ERRTYPE command.).

data property

Return the TRIGger:A:BUS:B<x>:MIL1553B:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:DATa? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .parity: The TRIGger:A:BUS:B<x>:MIL1553B:DATa:PARity command.
  • .value: The TRIGger:A:BUS:B<x>:MIL1553B:DATa:VALue command.

errtype property

Return the TRIGger:A:BUS:B<x>:MIL1553B:ERRTYPE command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to ERRor, this command specifies the signaling error type to be used in the trigger: Parity, Sync, Manchester or Data. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:ERRTYPE? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:ERRTYPE? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:ERRTYPE value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:ERRTYPE {PARity|SYNC|MANCHester|DATA}
- TRIGger:A:BUS:B<x>:MIL1553B:ERRTYPE?

status property

Return the TRIGger:A:BUS:B<x>:MIL1553B:STATus command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .address: The TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess command tree.
  • .bit: The TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT command tree.
  • .parity: The TRIGger:A:BUS:B<x>:MIL1553B:STATus:PARity command.

time property

Return the TRIGger:A:BUS:B<x>:MIL1553B:TIMe command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:TIMe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:TIMe? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .lesslimit: The TRIGger:A:BUS:B<x>:MIL1553B:TIMe:LESSLimit command.
  • .morelimit: The TRIGger:A:BUS:B<x>:MIL1553B:TIMe:MORELimit command.
  • .qualifier: The TRIGger:A:BUS:B<x>:MIL1553B:TIMe:QUALifier command.

TriggerABusBItemMil1553bCommand

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:MIL1553B:COMMAND command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND? query and raise an AssertionError if the returned value does not match value.
Properties
  • .address: The TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess command tree.
  • .count: The TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:COUNt command.
  • .parity: The TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:PARity command.
  • .subaddress: The TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:SUBADdress command.
  • .trbit: The TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:TRBit command.

address property

Return the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .hivalue: The TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:HIVALue command.
  • .qualifier: The TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:QUALifier command.
  • .value: The TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:VALue command.

count property

Return the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:COUNt command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to COMMAND, this command specifies the bit pattern for the 5-bit Word Count/Mode Code sub-address field that is to be used in the trigger. (Use the command TRIGGER:A:BUS:BX:MIL1553B:COMMAND:SUBADDRESS to specify Word Count or Mode Code.) In Word Count mode, this field defines the number of data words that is to be transmitted, or received, depending on the T/R bit setting. (Use the command TRIGGER:A:BUS:BX:MIL1553B:COMMAND:TRBIT to set the T/R bit.) A word count value of 0 actually indicates a transfer of 32 data words. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:COUNt? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:COUNt? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:COUNt value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:COUNt <QString>
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:COUNt?
Info
  • QString is a quoted string of up to 5 characters, where the allowable characters are 0, 1 and X. The bits specified in the quoted string replace the least significant bits, leaving any unspecified upper bits unchanged.

parity property

Return the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:PARity command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to COMMAND, this command specifies the Command word parity that is to be used in the trigger. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:PARity? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:PARity? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:PARity value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:PARity {0|1|X|ZERo|ONE|NOCARE|OFF|ON}
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:PARity?
Info
  • 0
  • 1
  • X sets the value to X (‘don’t care’) which is the default.
  • ZERO sets the value to 0.
  • ONE sets the value to 1.
  • NOCARE sets the value to X (‘don’t care’) which is the default.
  • OFF sets the value to 0.
  • ON sets the value to 1.

subaddress property

Return the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:SUBADdress command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to COMMAND, this command specifies the 5 bit sub-address that is to be used in the trigger. When the sub-address value is set to 00000 or 11111 binary, it specifies that the command is a ‘Mode Code’ command. Any other value specifies that it is a ‘Word Count’ command. The default is all X’s (don’t care). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:SUBADdress? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:SUBADdress? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:SUBADdress value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:SUBADdress <QString>
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:SUBADdress?

trbit property

Return the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:TRBit command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to COMMAND, this command specifies that the transmit/receive bit (bit 9) is to be used in the trigger. The transmit/receive bit defines the direction of information flow, and is always from the point of view of the remote terminal. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:TRBit? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:TRBit? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:TRBit value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:TRBit {RX|TX|X}
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:TRBit?
Info
  • RX (logic 0) directs the instrument to trigger on a TX or ‘transmit’ from a remote terminal .
  • TX (logic 1) directs the instrument to trigger on an RX or ‘receive’ from a remote terminal.
  • X indicates ‘don’t care’.

TriggerABusBItemMil1553bCommandAddress

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess? query and raise an AssertionError if the returned value does not match value.
Properties
  • .hivalue: The TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:HIVALue command.
  • .qualifier: The TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:QUALifier command.
  • .value: The TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:VALue command.

hivalue property

Return the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:HIVALue command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to COMMAND, and the qualifier is set to INrange or OUTrange, this command specifies the upper limit of the range for the remote terminal address field. (Use the command TRIGGER:A:BUS:BX:MIL1553B:COMMAND:ADDRESS:VALUE to specify the lower limit of the range.) The default is all X’s (don’t care). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:HIVALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:HIVALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:HIVALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:HIVALue <QString>
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:HIVALue?

qualifier property

Return the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:QUALifier command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to COMMAND, this command specifies the qualifier to be used with the remote terminal address field. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:QUALifier {LESSthan|MOREthan|EQual|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:QUALifier?
Info
  • LESSthan sets the Command Address qualifier to less than.
  • MOREthan sets the Command Address qualifier to greater than.
  • EQual sets the Command Address qualifier to equal.
  • UNEQual sets the Command Address qualifier to not equal.
  • LESSEQual sets the Command Address qualifier to less than or equal.
  • MOREEQual sets the Command Address qualifier to greater than or equal.
  • INrange sets the Command Address qualifier to in range.
  • OUTrange sets the Command Address qualifier to out of range.

value property

Return the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:VALue command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to COMMAND, and the qualifier is set to LESSthan, MOREthan, EQual, UNEQual, LESSEQual or MOREEQual, this command specifies the value of the 5-bit remote terminal address to be used in the trigger. When the MIL-STD-1553 bus trigger condition is set to COMMAND, and the qualifier is set to INrange or OUTrange, this command specifies the lower limit of the remote terminal address range. The default is all X’s (don’t care). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:VALue <QString>
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:VALue?

TriggerABusBItemMil1553bCommandAddressHivalue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:HIVALue command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to COMMAND, and the qualifier is set to INrange or OUTrange, this command specifies the upper limit of the range for the remote terminal address field. (Use the command TRIGGER:A:BUS:BX:MIL1553B:COMMAND:ADDRESS:VALUE to specify the lower limit of the range.) The default is all X’s (don’t care). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:HIVALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:HIVALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:HIVALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:HIVALue <QString>
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:HIVALue?

TriggerABusBItemMil1553bCommandAddressQualifier

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:QUALifier command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to COMMAND, this command specifies the qualifier to be used with the remote terminal address field. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:QUALifier {LESSthan|MOREthan|EQual|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:QUALifier?
Info
  • LESSthan sets the Command Address qualifier to less than.
  • MOREthan sets the Command Address qualifier to greater than.
  • EQual sets the Command Address qualifier to equal.
  • UNEQual sets the Command Address qualifier to not equal.
  • LESSEQual sets the Command Address qualifier to less than or equal.
  • MOREEQual sets the Command Address qualifier to greater than or equal.
  • INrange sets the Command Address qualifier to in range.
  • OUTrange sets the Command Address qualifier to out of range.

TriggerABusBItemMil1553bCommandAddressValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:VALue command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to COMMAND, and the qualifier is set to LESSthan, MOREthan, EQual, UNEQual, LESSEQual or MOREEQual, this command specifies the value of the 5-bit remote terminal address to be used in the trigger. When the MIL-STD-1553 bus trigger condition is set to COMMAND, and the qualifier is set to INrange or OUTrange, this command specifies the lower limit of the remote terminal address range. The default is all X’s (don’t care). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:VALue <QString>
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:VALue?

TriggerABusBItemMil1553bCommandCount

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:COUNt command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to COMMAND, this command specifies the bit pattern for the 5-bit Word Count/Mode Code sub-address field that is to be used in the trigger. (Use the command TRIGGER:A:BUS:BX:MIL1553B:COMMAND:SUBADDRESS to specify Word Count or Mode Code.) In Word Count mode, this field defines the number of data words that is to be transmitted, or received, depending on the T/R bit setting. (Use the command TRIGGER:A:BUS:BX:MIL1553B:COMMAND:TRBIT to set the T/R bit.) A word count value of 0 actually indicates a transfer of 32 data words. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:COUNt? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:COUNt? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:COUNt value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:COUNt <QString>
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:COUNt?
Info
  • QString is a quoted string of up to 5 characters, where the allowable characters are 0, 1 and X. The bits specified in the quoted string replace the least significant bits, leaving any unspecified upper bits unchanged.

TriggerABusBItemMil1553bCommandParity

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:PARity command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to COMMAND, this command specifies the Command word parity that is to be used in the trigger. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:PARity? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:PARity? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:PARity value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:PARity {0|1|X|ZERo|ONE|NOCARE|OFF|ON}
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:PARity?
Info
  • 0
  • 1
  • X sets the value to X (‘don’t care’) which is the default.
  • ZERO sets the value to 0.
  • ONE sets the value to 1.
  • NOCARE sets the value to X (‘don’t care’) which is the default.
  • OFF sets the value to 0.
  • ON sets the value to 1.

TriggerABusBItemMil1553bCommandSubaddress

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:SUBADdress command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to COMMAND, this command specifies the 5 bit sub-address that is to be used in the trigger. When the sub-address value is set to 00000 or 11111 binary, it specifies that the command is a ‘Mode Code’ command. Any other value specifies that it is a ‘Word Count’ command. The default is all X’s (don’t care). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:SUBADdress? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:SUBADdress? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:SUBADdress value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:SUBADdress <QString>
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:SUBADdress?

TriggerABusBItemMil1553bCommandTrbit

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:TRBit command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to COMMAND, this command specifies that the transmit/receive bit (bit 9) is to be used in the trigger. The transmit/receive bit defines the direction of information flow, and is always from the point of view of the remote terminal. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:TRBit? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:TRBit? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:TRBit value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:TRBit {RX|TX|X}
- TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:TRBit?
Info
  • RX (logic 0) directs the instrument to trigger on a TX or ‘transmit’ from a remote terminal .
  • TX (logic 1) directs the instrument to trigger on an RX or ‘receive’ from a remote terminal.
  • X indicates ‘don’t care’.

TriggerABusBItemMil1553bCondition

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:MIL1553B:CONDition command.

Description
  • This command specifies a word type or condition within a MIL-STD-1553 bus word to trigger on. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:CONDition {SYNC|COMMAND|STATus|DATA|TIMe|ERRor}
- TRIGger:A:BUS:B<x>:MIL1553B:CONDition?
Info
  • SYNC refers to the 3-bit sync pulse that precedes each word.
  • COMMAND is one of 3 16-bit word types. It specifies the function that a remote terminal is to perform.
  • STATus is one of 3 16-bit word types. Remote terminals respond to valid message transmissions via status words.
  • DATA is one of 3 16-bit word types.
  • TIMe specifies to trigger on either the RT (remote terminal response time), or the IMG (Inter-message Gap). Use the commands TRIGGER:A:BUS:BX:MIL1553B:TIME:QUALIFIER, TRIGGER:A:BUS:BX:MIL1553B:TIME:LESSLIMIT, and TRIGGER:A:BUS:BX:MIL1553B:TIME:MORELIMIT to specify the time parameters.
  • ERRor specifies to trigger upon a signaling error. (You can specify which type of error - Parity, Sync, Manchester or Non-contiguous Data - by using the TRIGGER:A:BUS:BX:MIL1553B:ERRTYPE command.).

TriggerABusBItemMil1553bData

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:MIL1553B:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:DATa? query and raise an AssertionError if the returned value does not match value.
Properties
  • .parity: The TRIGger:A:BUS:B<x>:MIL1553B:DATa:PARity command.
  • .value: The TRIGger:A:BUS:B<x>:MIL1553B:DATa:VALue command.

parity property

Return the TRIGger:A:BUS:B<x>:MIL1553B:DATa:PARity command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to DATa, this command specifies the data parity bit to be used in the trigger. Returned values are 0, 1, or X (don’t care). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:DATa:PARity? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:DATa:PARity? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:DATa:PARity value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:DATa:PARity {0|1|X|ZERo|ONE|NOCARE|OFF|ON}
- TRIGger:A:BUS:B<x>:MIL1553B:DATa:PARity?
Info
  • 0
  • 1
  • X sets the value to X (‘don’t care’) which is the default.
  • ZERO sets the value to 0.
  • ONE sets the value to 1.
  • NOCARE sets the value to X (‘don’t care’) which is the default.
  • OFF sets the value to 0.
  • ON sets the value to 1.

value property

Return the TRIGger:A:BUS:B<x>:MIL1553B:DATa:VALue command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to DATa, this command specifies the data binary pattern to be used in the trigger. This is a 16-bit field. The default is all X’s (don’t care). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:DATa:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:MIL1553B:DATa:VALue?

TriggerABusBItemMil1553bDataParity

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:MIL1553B:DATa:PARity command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to DATa, this command specifies the data parity bit to be used in the trigger. Returned values are 0, 1, or X (don’t care). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:DATa:PARity? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:DATa:PARity? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:DATa:PARity value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:DATa:PARity {0|1|X|ZERo|ONE|NOCARE|OFF|ON}
- TRIGger:A:BUS:B<x>:MIL1553B:DATa:PARity?
Info
  • 0
  • 1
  • X sets the value to X (‘don’t care’) which is the default.
  • ZERO sets the value to 0.
  • ONE sets the value to 1.
  • NOCARE sets the value to X (‘don’t care’) which is the default.
  • OFF sets the value to 0.
  • ON sets the value to 1.

TriggerABusBItemMil1553bDataValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:MIL1553B:DATa:VALue command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to DATa, this command specifies the data binary pattern to be used in the trigger. This is a 16-bit field. The default is all X’s (don’t care). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:DATa:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:MIL1553B:DATa:VALue?

TriggerABusBItemMil1553bErrtype

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:MIL1553B:ERRTYPE command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to ERRor, this command specifies the signaling error type to be used in the trigger: Parity, Sync, Manchester or Data. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:ERRTYPE? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:ERRTYPE? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:ERRTYPE value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:ERRTYPE {PARity|SYNC|MANCHester|DATA}
- TRIGger:A:BUS:B<x>:MIL1553B:ERRTYPE?

TriggerABusBItemMil1553bStatus

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:MIL1553B:STATus command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus? query and raise an AssertionError if the returned value does not match value.
Properties
  • .address: The TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess command tree.
  • .bit: The TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT command tree.
  • .parity: The TRIGger:A:BUS:B<x>:MIL1553B:STATus:PARity command.

address property

Return the TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .hivalue: The TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:HIVALue command.
  • .qualifier: The TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:QUALifier command.
  • .value: The TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:VALue command.

bit property

Return the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .bcr: The TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:BCR command.
  • .busy: The TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:BUSY command.
  • .dbca: The TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:DBCA command.
  • .instr: The TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:INSTR command.
  • .me: The TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:ME command.
  • .srq: The TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:SRQ command.
  • .subsf: The TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:SUBSF command.
  • .tf: The TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:TF command.

parity property

Return the TRIGger:A:BUS:B<x>:MIL1553B:STATus:PARity command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to STATus, this command specifies the status parity bit value to be used in the trigger. Returned values are 0, 1, or X (don’t care, which is the default). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:PARity? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:PARity? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:PARity value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:PARity {0|1|X|ZERo|ONE|NOCARE|OFF|ON}
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:PARity?
Info
  • 0
  • 1
  • X sets the value to X (‘don’t care’) which is the default.
  • ZERO sets the value to 0.
  • ONE sets the value to 1.
  • NOCARE sets the value to X (‘don’t care’) which is the default.
  • OFF sets the value to 0.
  • ON sets the value to 1.

TriggerABusBItemMil1553bStatusAddress

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess? query and raise an AssertionError if the returned value does not match value.
Properties
  • .hivalue: The TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:HIVALue command.
  • .qualifier: The TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:QUALifier command.
  • .value: The TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:VALue command.

hivalue property

Return the TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:HIVALue command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to STATus, and the qualifier is set to INrange or OUTrange, this command specifies the upper limit for the 5 bit remote terminal address field of the Status word. (Use the command TRIGGER:A:BUS:BX:MIL1553B:STATUS:ADDRESS:VALUE to specify the lower limit.) The default is all X’s (don’t care). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:HIVALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:HIVALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:HIVALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:HIVALue <QString>
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:HIVALue?

qualifier property

Return the TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:QUALifier command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to STATus, this command specifies the qualifier to be used with the address field. The default is EQUAL. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:QUALifier {LESSthan|MOREthan|EQual|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:QUALifier?
Info
  • LESSthan sets the Status Address qualifier to less than.
  • MOREthan sets the Status Address qualifier to greater than.
  • EQual sets the Status Address qualifier to equal.
  • UNEQual sets the Status Address qualifier to not equal.
  • LESSEQual sets the Status Address qualifier to less than or equal.
  • MOREEQual sets the Status Address qualifier to greater than or equal.
  • INrange sets the Status Address qualifier to in range.
  • OUTrange sets the Status Address qualifier to out of range.

value property

Return the TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:VALue command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to STATus, and the qualifier is set to LESSthan, MOREthan, EQual, UNEQual, LESSEQual or MOREEQual, this command specifies the value of the 5-bit remote terminal address to be used in the trigger. When the MIL-STD-1553 bus trigger condition is set to STATus, and the qualifier is set to INrange or OUTrange, this command specifies the lower limit of the range. (Use the command TRIGGER:A:BUS:BX:MIL1553B:STATUS:ADDRESS:HIVALUE to specify the upper limit of the range.) The default is all X’s (don’t care). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:VALue <QString>
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:VALue?

TriggerABusBItemMil1553bStatusAddressHivalue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:HIVALue command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to STATus, and the qualifier is set to INrange or OUTrange, this command specifies the upper limit for the 5 bit remote terminal address field of the Status word. (Use the command TRIGGER:A:BUS:BX:MIL1553B:STATUS:ADDRESS:VALUE to specify the lower limit.) The default is all X’s (don’t care). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:HIVALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:HIVALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:HIVALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:HIVALue <QString>
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:HIVALue?

TriggerABusBItemMil1553bStatusAddressQualifier

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:QUALifier command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to STATus, this command specifies the qualifier to be used with the address field. The default is EQUAL. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:QUALifier {LESSthan|MOREthan|EQual|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:QUALifier?
Info
  • LESSthan sets the Status Address qualifier to less than.
  • MOREthan sets the Status Address qualifier to greater than.
  • EQual sets the Status Address qualifier to equal.
  • UNEQual sets the Status Address qualifier to not equal.
  • LESSEQual sets the Status Address qualifier to less than or equal.
  • MOREEQual sets the Status Address qualifier to greater than or equal.
  • INrange sets the Status Address qualifier to in range.
  • OUTrange sets the Status Address qualifier to out of range.

TriggerABusBItemMil1553bStatusAddressValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:VALue command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to STATus, and the qualifier is set to LESSthan, MOREthan, EQual, UNEQual, LESSEQual or MOREEQual, this command specifies the value of the 5-bit remote terminal address to be used in the trigger. When the MIL-STD-1553 bus trigger condition is set to STATus, and the qualifier is set to INrange or OUTrange, this command specifies the lower limit of the range. (Use the command TRIGGER:A:BUS:BX:MIL1553B:STATUS:ADDRESS:HIVALUE to specify the upper limit of the range.) The default is all X’s (don’t care). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:VALue <QString>
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:ADDRess:VALue?

TriggerABusBItemMil1553bStatusBit

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT? query and raise an AssertionError if the returned value does not match value.
Properties
  • .bcr: The TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:BCR command.
  • .busy: The TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:BUSY command.
  • .dbca: The TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:DBCA command.
  • .instr: The TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:INSTR command.
  • .me: The TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:ME command.
  • .srq: The TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:SRQ command.
  • .subsf: The TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:SUBSF command.
  • .tf: The TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:TF command.

bcr property

Return the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:BCR command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to STATus, this command specifies the status word broadcast command received (BCR) bit value (bit 15) to be used in the trigger. Returned values are 0, 1, or X (don’t care, which is the default). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:BCR? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:BCR? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:BCR value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:BCR {0|1|X|ZERo|ONE|NOCARE|OFF|ON}
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:BCR?
Info
  • 0
  • 1
  • X sets the value to X (‘don’t care’) which is the default.
  • ZERO sets the value to 0.
  • ONE sets the value to 1.
  • NOCARE sets the value to X (‘don’t care’) which is the default.
  • OFF sets the value to 0.
  • ON sets the value to 1.

busy property

Return the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:BUSY command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to STATus, this command specifies the status word busy bit value (bit 16) to be used in the trigger. Returned values are 0, 1, or X (don’t care, which is the default). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:BUSY? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:BUSY? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:BUSY value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:BUSY {0|1|X|ZERo|ONE|NOCARE|OFF|ON}
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:BUSY?
Info
  • 0
  • 1
  • X sets the value to X (‘don’t care’) which is the default.
  • ZERO sets the value to 0.
  • ONE sets the value to 1.
  • NOCARE sets the value to X (‘don’t care’) which is the default.
  • OFF sets the value to 0.
  • ON sets the value to 1.

dbca property

Return the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:DBCA command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to STATus, this command specifies the status word dynamic bus control acceptance (DBCA) bit value (bit 18) to be used in the trigger. Returned values are 0, 1, or X (don’t care, which is the default). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:DBCA? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:DBCA? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:DBCA value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:DBCA {0|1|X|ZERo|ONE|NOCARE|OFF|ON}
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:DBCA?
Info
  • 0
  • 1
  • X sets the value to X (‘don’t care’) which is the default.
  • ZERO sets the value to 0.
  • ONE sets the value to 1.
  • NOCARE sets the value to X (‘don’t care’) which is the default.
  • OFF sets the value to 0.
  • ON sets the value to 1.

instr property

Return the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:INSTR command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to STATus, this command specifies the status word instrumentation bit value (bit 10) to be used in the trigger. Returned values are 0, 1, or X (don’t care, which is the default). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:INSTR? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:INSTR? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:INSTR value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:INSTR {0|1|X|ZERo|ONE|NOCARE|OFF|ON}
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:INSTR?
Info
  • 0
  • 1
  • X sets the value to X (‘don’t care’) which is the default.
  • ZERO sets the value to 0.
  • ONE sets the value to 1.
  • NOCARE sets the value to X (‘don’t care’) which is the default.
  • OFF sets the value to 0.
  • ON sets the value to 1.

me property

Return the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:ME command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to STATus, this command specifies the status word message error bit value (bit 9) to be used in the trigger. Returned values are 0, 1, or X (don’t care, which is the default). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:ME? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:ME? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:ME value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:ME {0|1|X|ZERo|ONE|NOCARE|OFF|ON}
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:ME?
Info
  • 0
  • 1
  • X sets the value to X (‘don’t care’) which is the default.
  • ZERO sets the value to 0.
  • ONE sets the value to 1.
  • NOCARE sets the value to X (‘don’t care’) which is the default.
  • OFF sets the value to 0.
  • ON sets the value to 1.

srq property

Return the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:SRQ command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to STATus, this command specifies the status word service request (SRQ) bit value (bit 11) to be used in the trigger. Returned values are 0, 1, or X (don’t care, which is the default). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:SRQ? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:SRQ? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:SRQ value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:SRQ {0|1|X|ZERo|ONE|NOCARE|OFF|ON}
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:SRQ?
Info
  • 0
  • 1
  • X sets the value to X (‘don’t care’) which is the default.
  • ZERO sets the value to 0.
  • ONE sets the value to 1.
  • NOCARE sets the value to X (‘don’t care’) which is the default.
  • OFF sets the value to 0.
  • ON sets the value to 1.

subsf property

Return the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:SUBSF command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to STATus, this command specifies the status word subsystem flag bit value (bit 17) to be used in the trigger. Returned values are 0, 1, or X (don’t care, which is the default). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:SUBSF? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:SUBSF? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:SUBSF value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:SUBSF {0|1|X|ZERo|ONE|NOCARE|OFF|ON}
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:SUBSF?
Info
  • 0
  • 1
  • X sets the value to X (‘don’t care’) which is the default.
  • ZERO sets the value to 0.
  • ONE sets the value to 1.
  • NOCARE sets the value to X (‘don’t care’) which is the default.
  • OFF sets the value to 0.
  • ON sets the value to 1.

tf property

Return the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:TF command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to STATus, this command specifies the status word terminal flag bit value (bit 19) to be used in the trigger. Returned values are 0, 1, or X (don’t care, which is the default). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:TF? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:TF? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:TF value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:TF {0|1|X|ZERo|ONE|NOCARE|OFF|ON}
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:TF?
Info
  • 0
  • 1
  • X sets the value to X (‘don’t care’) which is the default.
  • ZERO sets the value to 0.
  • ONE sets the value to 1.
  • NOCARE sets the value to X (‘don’t care’) which is the default.
  • OFF sets the value to 0.
  • ON sets the value to 1.

TriggerABusBItemMil1553bStatusBitBcr

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:BCR command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to STATus, this command specifies the status word broadcast command received (BCR) bit value (bit 15) to be used in the trigger. Returned values are 0, 1, or X (don’t care, which is the default). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:BCR? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:BCR? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:BCR value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:BCR {0|1|X|ZERo|ONE|NOCARE|OFF|ON}
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:BCR?
Info
  • 0
  • 1
  • X sets the value to X (‘don’t care’) which is the default.
  • ZERO sets the value to 0.
  • ONE sets the value to 1.
  • NOCARE sets the value to X (‘don’t care’) which is the default.
  • OFF sets the value to 0.
  • ON sets the value to 1.

TriggerABusBItemMil1553bStatusBitBusy

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:BUSY command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to STATus, this command specifies the status word busy bit value (bit 16) to be used in the trigger. Returned values are 0, 1, or X (don’t care, which is the default). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:BUSY? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:BUSY? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:BUSY value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:BUSY {0|1|X|ZERo|ONE|NOCARE|OFF|ON}
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:BUSY?
Info
  • 0
  • 1
  • X sets the value to X (‘don’t care’) which is the default.
  • ZERO sets the value to 0.
  • ONE sets the value to 1.
  • NOCARE sets the value to X (‘don’t care’) which is the default.
  • OFF sets the value to 0.
  • ON sets the value to 1.

TriggerABusBItemMil1553bStatusBitDbca

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:DBCA command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to STATus, this command specifies the status word dynamic bus control acceptance (DBCA) bit value (bit 18) to be used in the trigger. Returned values are 0, 1, or X (don’t care, which is the default). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:DBCA? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:DBCA? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:DBCA value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:DBCA {0|1|X|ZERo|ONE|NOCARE|OFF|ON}
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:DBCA?
Info
  • 0
  • 1
  • X sets the value to X (‘don’t care’) which is the default.
  • ZERO sets the value to 0.
  • ONE sets the value to 1.
  • NOCARE sets the value to X (‘don’t care’) which is the default.
  • OFF sets the value to 0.
  • ON sets the value to 1.

TriggerABusBItemMil1553bStatusBitInstr

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:INSTR command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to STATus, this command specifies the status word instrumentation bit value (bit 10) to be used in the trigger. Returned values are 0, 1, or X (don’t care, which is the default). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:INSTR? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:INSTR? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:INSTR value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:INSTR {0|1|X|ZERo|ONE|NOCARE|OFF|ON}
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:INSTR?
Info
  • 0
  • 1
  • X sets the value to X (‘don’t care’) which is the default.
  • ZERO sets the value to 0.
  • ONE sets the value to 1.
  • NOCARE sets the value to X (‘don’t care’) which is the default.
  • OFF sets the value to 0.
  • ON sets the value to 1.

TriggerABusBItemMil1553bStatusBitMe

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:ME command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to STATus, this command specifies the status word message error bit value (bit 9) to be used in the trigger. Returned values are 0, 1, or X (don’t care, which is the default). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:ME? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:ME? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:ME value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:ME {0|1|X|ZERo|ONE|NOCARE|OFF|ON}
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:ME?
Info
  • 0
  • 1
  • X sets the value to X (‘don’t care’) which is the default.
  • ZERO sets the value to 0.
  • ONE sets the value to 1.
  • NOCARE sets the value to X (‘don’t care’) which is the default.
  • OFF sets the value to 0.
  • ON sets the value to 1.

TriggerABusBItemMil1553bStatusBitSrq

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:SRQ command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to STATus, this command specifies the status word service request (SRQ) bit value (bit 11) to be used in the trigger. Returned values are 0, 1, or X (don’t care, which is the default). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:SRQ? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:SRQ? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:SRQ value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:SRQ {0|1|X|ZERo|ONE|NOCARE|OFF|ON}
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:SRQ?
Info
  • 0
  • 1
  • X sets the value to X (‘don’t care’) which is the default.
  • ZERO sets the value to 0.
  • ONE sets the value to 1.
  • NOCARE sets the value to X (‘don’t care’) which is the default.
  • OFF sets the value to 0.
  • ON sets the value to 1.

TriggerABusBItemMil1553bStatusBitSubsf

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:SUBSF command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to STATus, this command specifies the status word subsystem flag bit value (bit 17) to be used in the trigger. Returned values are 0, 1, or X (don’t care, which is the default). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:SUBSF? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:SUBSF? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:SUBSF value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:SUBSF {0|1|X|ZERo|ONE|NOCARE|OFF|ON}
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:SUBSF?
Info
  • 0
  • 1
  • X sets the value to X (‘don’t care’) which is the default.
  • ZERO sets the value to 0.
  • ONE sets the value to 1.
  • NOCARE sets the value to X (‘don’t care’) which is the default.
  • OFF sets the value to 0.
  • ON sets the value to 1.

TriggerABusBItemMil1553bStatusBitTf

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:TF command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to STATus, this command specifies the status word terminal flag bit value (bit 19) to be used in the trigger. Returned values are 0, 1, or X (don’t care, which is the default). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:TF? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:TF? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:TF value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:TF {0|1|X|ZERo|ONE|NOCARE|OFF|ON}
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:TF?
Info
  • 0
  • 1
  • X sets the value to X (‘don’t care’) which is the default.
  • ZERO sets the value to 0.
  • ONE sets the value to 1.
  • NOCARE sets the value to X (‘don’t care’) which is the default.
  • OFF sets the value to 0.
  • ON sets the value to 1.

TriggerABusBItemMil1553bStatusParity

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:MIL1553B:STATus:PARity command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to STATus, this command specifies the status parity bit value to be used in the trigger. Returned values are 0, 1, or X (don’t care, which is the default). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:PARity? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:PARity? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:STATus:PARity value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:PARity {0|1|X|ZERo|ONE|NOCARE|OFF|ON}
- TRIGger:A:BUS:B<x>:MIL1553B:STATus:PARity?
Info
  • 0
  • 1
  • X sets the value to X (‘don’t care’) which is the default.
  • ZERO sets the value to 0.
  • ONE sets the value to 1.
  • NOCARE sets the value to X (‘don’t care’) which is the default.
  • OFF sets the value to 0.
  • ON sets the value to 1.

TriggerABusBItemMil1553bTime

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:MIL1553B:TIMe command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:TIMe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:TIMe? query and raise an AssertionError if the returned value does not match value.
Properties
  • .lesslimit: The TRIGger:A:BUS:B<x>:MIL1553B:TIMe:LESSLimit command.
  • .morelimit: The TRIGger:A:BUS:B<x>:MIL1553B:TIMe:MORELimit command.
  • .qualifier: The TRIGger:A:BUS:B<x>:MIL1553B:TIMe:QUALifier command.

lesslimit property

Return the TRIGger:A:BUS:B<x>:MIL1553B:TIMe:LESSLimit command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to TIMe, this command specifies either the minimum remote terminal response time (RT) limit for the amount of time the terminal has to transmit, or it specifies the minimum inter-message gap (IMG). (You can specify RT or IMG using the TRIGGER:A:BUS:BX:MIL1553B:CONDITION TIMe command.) B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:TIMe:LESSLimit? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:TIMe:LESSLimit? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:TIMe:LESSLimit value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:TIMe:LESSLimit <NR3>
- TRIGger:A:BUS:B<x>:MIL1553B:TIMe:LESSLimit?
Info
  • <NR3> is a floating point number that specifies either the minimum remote terminal response time (RT) or the inter-message gap (IMG) in seconds.

morelimit property

Return the TRIGger:A:BUS:B<x>:MIL1553B:TIMe:MORELimit command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to TIMe, this command specifies either the maximum remote terminal response time (RT) limit for the amount of time the terminal has to transmit, or it specifies the maximum inter-message gap (IMG). (You can specify the RT and IMG using the TRIGGER:A:BUS:BX:MIL1553B:CONDITION TIMe command.)
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:TIMe:MORELimit? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:TIMe:MORELimit? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:TIMe:MORELimit value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:TIMe:MORELimit <NR3>
- TRIGger:A:BUS:B<x>:MIL1553B:TIMe:MORELimit?
Info
  • <NR3> is a floating point number that specifies either the maximum remote terminal response time (RT) or the inter-message gap (IMG) in seconds.

qualifier property

Return the TRIGger:A:BUS:B<x>:MIL1553B:TIMe:QUALifier command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to TIMe, this command specifies the trigger data time qualifier. (This includes a smaller set of arguments than other qualifier commands.) B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:TIMe:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:TIMe:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:TIMe:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:TIMe:QUALifier {LESSthan|MOREthan|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:MIL1553B:TIMe:QUALifier?
Info
  • LESSthan sets the Time qualifier to less than minimum.
  • MOREthan sets the Time qualifier to greater than maximum.
  • INrange sets the Time qualifier to inside range.
  • OUTrange sets the Time qualifier to out of range.

TriggerABusBItemMil1553bTimeLesslimit

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:MIL1553B:TIMe:LESSLimit command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to TIMe, this command specifies either the minimum remote terminal response time (RT) limit for the amount of time the terminal has to transmit, or it specifies the minimum inter-message gap (IMG). (You can specify RT or IMG using the TRIGGER:A:BUS:BX:MIL1553B:CONDITION TIMe command.) B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:TIMe:LESSLimit? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:TIMe:LESSLimit? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:TIMe:LESSLimit value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:TIMe:LESSLimit <NR3>
- TRIGger:A:BUS:B<x>:MIL1553B:TIMe:LESSLimit?
Info
  • <NR3> is a floating point number that specifies either the minimum remote terminal response time (RT) or the inter-message gap (IMG) in seconds.

TriggerABusBItemMil1553bTimeMorelimit

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:MIL1553B:TIMe:MORELimit command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to TIMe, this command specifies either the maximum remote terminal response time (RT) limit for the amount of time the terminal has to transmit, or it specifies the maximum inter-message gap (IMG). (You can specify the RT and IMG using the TRIGGER:A:BUS:BX:MIL1553B:CONDITION TIMe command.)
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:TIMe:MORELimit? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:TIMe:MORELimit? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:TIMe:MORELimit value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:TIMe:MORELimit <NR3>
- TRIGger:A:BUS:B<x>:MIL1553B:TIMe:MORELimit?
Info
  • <NR3> is a floating point number that specifies either the maximum remote terminal response time (RT) or the inter-message gap (IMG) in seconds.

TriggerABusBItemMil1553bTimeQualifier

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:MIL1553B:TIMe:QUALifier command.

Description
  • When the MIL-STD-1553 bus trigger condition is set to TIMe, this command specifies the trigger data time qualifier. (This includes a smaller set of arguments than other qualifier commands.) B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:MIL1553B:TIMe:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:TIMe:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:MIL1553B:TIMe:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:MIL1553B:TIMe:QUALifier {LESSthan|MOREthan|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:MIL1553B:TIMe:QUALifier?
Info
  • LESSthan sets the Time qualifier to less than minimum.
  • MOREthan sets the Time qualifier to greater than maximum.
  • INrange sets the Time qualifier to inside range.
  • OUTrange sets the Time qualifier to out of range.

TriggerABusBItemParallel

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:PARallel command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:PARallel? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:PARallel? query and raise an AssertionError if the returned value does not match value.
Properties
  • .value: The TRIGger:A:BUS:B<x>:PARallel:VALue command.

value property

Return the TRIGger:A:BUS:B<x>:PARallel:VALue command.

Description
  • This command specifies the binary data string to be used for a Parallel trigger. Applies to bus , where x
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:PARallel:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:PARallel:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:PARallel:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:PARallel:VALue <QString>
- TRIGger:A:BUS:B<x>:PARallel:VALue?
Info
  • <QString> is the binary data string.

TriggerABusBItemParallelValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:PARallel:VALue command.

Description
  • This command specifies the binary data string to be used for a Parallel trigger. Applies to bus , where x
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:PARallel:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:PARallel:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:PARallel:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:PARallel:VALue <QString>
- TRIGger:A:BUS:B<x>:PARallel:VALue?
Info
  • <QString> is the binary data string.

TriggerABusBItemRs232c

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:RS232C command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C? query and raise an AssertionError if the returned value does not match value.
Properties
  • .condition: The TRIGger:A:BUS:B<x>:RS232C:CONDition command.
  • .rx: The TRIGger:A:BUS:B<x>:RS232C:RX command tree.
  • .tx: The TRIGger:A:BUS:B<x>:RS232C:TX command tree.

condition property

Return the TRIGger:A:BUS:B<x>:RS232C:CONDition command.

Description
  • This command specifies the condition for an RS-232C trigger, where x B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:RS232C:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:RS232C:CONDition {RXSTArt|RXDATA|RXENDPacket|TXSTArt|TXDATA|TXENDPacket}
- TRIGger:A:BUS:B<x>:RS232C:CONDition?
Info
  • RXSTArt specifies a search based on the RX Start Bit.
  • RXDATA specifies a search based on RX Data.
  • RXENDPacket specifies a search based on the RX End of Packet condition.
  • TXSTArt specifies a search base on the TX Start Bit.
  • TXDATA specifies a search based on TX Data.
  • TXENDPacket specifies a search based on the TX End of Packet condition.

rx property

Return the TRIGger:A:BUS:B<x>:RS232C:RX command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:RX? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:RX? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .data: The TRIGger:A:BUS:B<x>:RS232C:RX:DATa command tree.

tx property

Return the TRIGger:A:BUS:B<x>:RS232C:TX command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:TX? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:TX? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .data: The TRIGger:A:BUS:B<x>:RS232C:TX:DATa command tree.

TriggerABusBItemRs232cCondition

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:RS232C:CONDition command.

Description
  • This command specifies the condition for an RS-232C trigger, where x B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:RS232C:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:RS232C:CONDition {RXSTArt|RXDATA|RXENDPacket|TXSTArt|TXDATA|TXENDPacket}
- TRIGger:A:BUS:B<x>:RS232C:CONDition?
Info
  • RXSTArt specifies a search based on the RX Start Bit.
  • RXDATA specifies a search based on RX Data.
  • RXENDPacket specifies a search based on the RX End of Packet condition.
  • TXSTArt specifies a search base on the TX Start Bit.
  • TXDATA specifies a search based on TX Data.
  • TXENDPacket specifies a search based on the TX End of Packet condition.

TriggerABusBItemRs232cRx

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:RS232C:RX command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:RX? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:RX? query and raise an AssertionError if the returned value does not match value.
Properties
  • .data: The TRIGger:A:BUS:B<x>:RS232C:RX:DATa command tree.

data property

Return the TRIGger:A:BUS:B<x>:RS232C:RX:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:RX:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:RX:DATa? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .size: The TRIGger:A:BUS:B<x>:RS232C:RX:DATa:SIZe command.
  • .value: The TRIGger:A:BUS:B<x>:RS232C:RX:DATa:VALue command.

TriggerABusBItemRs232cRxData

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:RS232C:RX:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:RX:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:RX:DATa? query and raise an AssertionError if the returned value does not match value.
Properties
  • .size: The TRIGger:A:BUS:B<x>:RS232C:RX:DATa:SIZe command.
  • .value: The TRIGger:A:BUS:B<x>:RS232C:RX:DATa:VALue command.

size property

Return the TRIGger:A:BUS:B<x>:RS232C:RX:DATa:SIZe command.

Description
  • This command specifies the length of the data string in Bytes for an RS-232 Trigger if the trigger condition is RXDATA. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:RX:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:RX:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:RS232C:RX:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:RS232C:RX:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:RS232C:RX:DATa:SIZe?
Info
  • <NR1> is the length of the data string in bytes.

value property

Return the TRIGger:A:BUS:B<x>:RS232C:RX:DATa:VALue command.

Description
  • This command specifies the binary data string for an RS-232 trigger if the trigger condition involves RX. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:RX:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:RX:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write() method will send the TRIGger:A:BUS:B<x>:RS232C:RX:DATa:VALue command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:RS232C:RX:DATa:VALue
- TRIGger:A:BUS:B<x>:RS232C:RX:DATa:VALue?
Info
  • <Qstring> is the binary data string to be used for the trigger.

TriggerABusBItemRs232cRxDataSize

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:RS232C:RX:DATa:SIZe command.

Description
  • This command specifies the length of the data string in Bytes for an RS-232 Trigger if the trigger condition is RXDATA. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:RX:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:RX:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:RS232C:RX:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:RS232C:RX:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:RS232C:RX:DATa:SIZe?
Info
  • <NR1> is the length of the data string in bytes.

TriggerABusBItemRs232cRxDataValue

Bases: SCPICmdWriteNoArguments, SCPICmdRead

The TRIGger:A:BUS:B<x>:RS232C:RX:DATa:VALue command.

Description
  • This command specifies the binary data string for an RS-232 trigger if the trigger condition involves RX. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:RX:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:RX:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write() method will send the TRIGger:A:BUS:B<x>:RS232C:RX:DATa:VALue command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:RS232C:RX:DATa:VALue
- TRIGger:A:BUS:B<x>:RS232C:RX:DATa:VALue?
Info
  • <Qstring> is the binary data string to be used for the trigger.

TriggerABusBItemRs232cTx

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:RS232C:TX command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:TX? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:TX? query and raise an AssertionError if the returned value does not match value.
Properties
  • .data: The TRIGger:A:BUS:B<x>:RS232C:TX:DATa command tree.

data property

Return the TRIGger:A:BUS:B<x>:RS232C:TX:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:TX:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:TX:DATa? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .size: The TRIGger:A:BUS:B<x>:RS232C:TX:DATa:SIZe command.
  • .value: The TRIGger:A:BUS:B<x>:RS232C:TX:DATa:VALue command.

TriggerABusBItemRs232cTxData

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:RS232C:TX:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:TX:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:TX:DATa? query and raise an AssertionError if the returned value does not match value.
Properties
  • .size: The TRIGger:A:BUS:B<x>:RS232C:TX:DATa:SIZe command.
  • .value: The TRIGger:A:BUS:B<x>:RS232C:TX:DATa:VALue command.

size property

Return the TRIGger:A:BUS:B<x>:RS232C:TX:DATa:SIZe command.

Description
  • This command specifies the length of the data string for an RS-232 trigger if the trigger condition is TXDATA. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:TX:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:TX:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:RS232C:TX:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:RS232C:TX:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:RS232C:TX:DATa:SIZe?
Info
  • <NR1> is the length of the data string in Bytes.

value property

Return the TRIGger:A:BUS:B<x>:RS232C:TX:DATa:VALue command.

Description
  • This command specifies the binary data string for an RS-232 trigger if the condition involves TX. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:TX:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:TX:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write() method will send the TRIGger:A:BUS:B<x>:RS232C:TX:DATa:VALue command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:RS232C:TX:DATa:VALue
- TRIGger:A:BUS:B<x>:RS232C:TX:DATa:VALue?
Info
  • <Qstring> is the binary data string to be used for the trigger.

TriggerABusBItemRs232cTxDataSize

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:RS232C:TX:DATa:SIZe command.

Description
  • This command specifies the length of the data string for an RS-232 trigger if the trigger condition is TXDATA. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:TX:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:TX:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:RS232C:TX:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:RS232C:TX:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:RS232C:TX:DATa:SIZe?
Info
  • <NR1> is the length of the data string in Bytes.

TriggerABusBItemRs232cTxDataValue

Bases: SCPICmdWriteNoArguments, SCPICmdRead

The TRIGger:A:BUS:B<x>:RS232C:TX:DATa:VALue command.

Description
  • This command specifies the binary data string for an RS-232 trigger if the condition involves TX. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:TX:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:TX:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write() method will send the TRIGger:A:BUS:B<x>:RS232C:TX:DATa:VALue command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:RS232C:TX:DATa:VALue
- TRIGger:A:BUS:B<x>:RS232C:TX:DATa:VALue?
Info
  • <Qstring> is the binary data string to be used for the trigger.

TriggerABusBItemSpi

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:SPI command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI? query and raise an AssertionError if the returned value does not match value.
Properties
  • .condition: The TRIGger:A:BUS:B<x>:SPI:CONDition command.
  • .data: The TRIGger:A:BUS:B<x>:SPI:DATa command tree.

condition property

Return the TRIGger:A:BUS:B<x>:SPI:CONDition command.

Description
  • This command specifies the trigger condition for a SPI trigger. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SPI:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SPI:CONDition {SS|STARTofframe|MISO|MOSI|MISOMOSI}
- TRIGger:A:BUS:B<x>:SPI:CONDition?
Info
  • SS specifies the Slave Selection condition.
  • STARTofframe is applicable when BUS:B<x>:SPI:FRAMING is set to IDLEtime. When the trigger condition is set to STARTofframe, the instrument triggers on the first SPI clock after an idle time when there are no clocks.
  • MISO specifies the Master-In Slave-Out condition.
  • MOSI specifies the Master-Out Slave-In condition.
  • MISOMOSI specifies the Master-In Slave-Out and Master-Out Slave-In conditions.

data property

Return the TRIGger:A:BUS:B<x>:SPI:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .size: The TRIGger:A:BUS:B<x>:SPI:DATa:SIZe command.
  • .in: The TRIGger:A:BUS:B<x>:SPI:DATa:IN command tree.
  • .miso: The TRIGger:A:BUS:B<x>:SPI:DATa:MISO command tree.
  • .out: The TRIGger:A:BUS:B<x>:SPI:DATa:OUT command tree.
  • .mosi: The TRIGger:A:BUS:B<x>:SPI:DATa:MOSI command tree.

TriggerABusBItemSpiCondition

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:SPI:CONDition command.

Description
  • This command specifies the trigger condition for a SPI trigger. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SPI:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SPI:CONDition {SS|STARTofframe|MISO|MOSI|MISOMOSI}
- TRIGger:A:BUS:B<x>:SPI:CONDition?
Info
  • SS specifies the Slave Selection condition.
  • STARTofframe is applicable when BUS:B<x>:SPI:FRAMING is set to IDLEtime. When the trigger condition is set to STARTofframe, the instrument triggers on the first SPI clock after an idle time when there are no clocks.
  • MISO specifies the Master-In Slave-Out condition.
  • MOSI specifies the Master-Out Slave-In condition.
  • MISOMOSI specifies the Master-In Slave-Out and Master-Out Slave-In conditions.

TriggerABusBItemSpiData

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:SPI:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa? query and raise an AssertionError if the returned value does not match value.
Properties
  • .size: The TRIGger:A:BUS:B<x>:SPI:DATa:SIZe command.
  • .in: The TRIGger:A:BUS:B<x>:SPI:DATa:IN command tree.
  • .miso: The TRIGger:A:BUS:B<x>:SPI:DATa:MISO command tree.
  • .out: The TRIGger:A:BUS:B<x>:SPI:DATa:OUT command tree.
  • .mosi: The TRIGger:A:BUS:B<x>:SPI:DATa:MOSI command tree.

in_ property

Return the TRIGger:A:BUS:B<x>:SPI:DATa:IN command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:IN? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:IN? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .value: The TRIGger:A:BUS:B<x>:SPI:DATa:IN:VALue command.

miso property

Return the TRIGger:A:BUS:B<x>:SPI:DATa:MISO command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MISO? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MISO? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .value: The TRIGger:A:BUS:B<x>:SPI:DATa:MISO:VALue command.

mosi property

Return the TRIGger:A:BUS:B<x>:SPI:DATa:MOSI command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MOSI? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MOSI? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .value: The TRIGger:A:BUS:B<x>:SPI:DATa:MOSI:VALue command.

out property

Return the TRIGger:A:BUS:B<x>:SPI:DATa:OUT command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:OUT? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:OUT? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .value: The TRIGger:A:BUS:B<x>:SPI:DATa:OUT:VALue command.

size property

Return the TRIGger:A:BUS:B<x>:SPI:DATa:SIZe command.

Description
  • This command specifies the length of the data string to be used for a SPI trigger if the trigger condition is DATa. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SPI:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:SPI:DATa:SIZe?
Info
  • <NR1> is the length of the data string in bytes.

TriggerABusBItemSpiDataIn

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:SPI:DATa:IN command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:IN? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:IN? query and raise an AssertionError if the returned value does not match value.
Properties
  • .value: The TRIGger:A:BUS:B<x>:SPI:DATa:IN:VALue command.

value property

Return the TRIGger:A:BUS:B<x>:SPI:DATa:IN:VALue command.

Description
  • This command specifies the binary data string to be used for a SPI trigger if the trigger condition is MISO or MISOMOSI. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:IN:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:IN:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:IN:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SPI:DATa:IN:VALue <QString>
- TRIGger:A:BUS:B<x>:SPI:DATa:IN:VALue?
Info
  • <QString> is the binary data string, where the number of bits is 8 times the number of bytes specified. The only allowed characters in the string are 0, 1, and X.

TriggerABusBItemSpiDataInValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:SPI:DATa:IN:VALue command.

Description
  • This command specifies the binary data string to be used for a SPI trigger if the trigger condition is MISO or MISOMOSI. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:IN:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:IN:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:IN:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SPI:DATa:IN:VALue <QString>
- TRIGger:A:BUS:B<x>:SPI:DATa:IN:VALue?
Info
  • <QString> is the binary data string, where the number of bits is 8 times the number of bytes specified. The only allowed characters in the string are 0, 1, and X.

TriggerABusBItemSpiDataMiso

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:SPI:DATa:MISO command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MISO? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MISO? query and raise an AssertionError if the returned value does not match value.
Properties
  • .value: The TRIGger:A:BUS:B<x>:SPI:DATa:MISO:VALue command.

value property

Return the TRIGger:A:BUS:B<x>:SPI:DATa:MISO:VALue command.

Description
  • This command specifies the binary data string to be used for a SPI trigger if the trigger condition is MISO or MISOMOSI. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MISO:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MISO:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MISO:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SPI:DATa:MISO:VALue <QString>
- TRIGger:A:BUS:B<x>:SPI:DATa:MISO:VALue?
Info
  • <QString> is the binary data string, where the number of bits is 8 times the number of bytes specified. The only allowed characters in the string are 0, 1, and X.

TriggerABusBItemSpiDataMisoValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:SPI:DATa:MISO:VALue command.

Description
  • This command specifies the binary data string to be used for a SPI trigger if the trigger condition is MISO or MISOMOSI. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MISO:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MISO:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MISO:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SPI:DATa:MISO:VALue <QString>
- TRIGger:A:BUS:B<x>:SPI:DATa:MISO:VALue?
Info
  • <QString> is the binary data string, where the number of bits is 8 times the number of bytes specified. The only allowed characters in the string are 0, 1, and X.

TriggerABusBItemSpiDataMosi

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:SPI:DATa:MOSI command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MOSI? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MOSI? query and raise an AssertionError if the returned value does not match value.
Properties
  • .value: The TRIGger:A:BUS:B<x>:SPI:DATa:MOSI:VALue command.

value property

Return the TRIGger:A:BUS:B<x>:SPI:DATa:MOSI:VALue command.

Description
  • This command specifies the binary data string to be used for a SPI trigger if the trigger condition is MOSI or MISOMOSI. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MOSI:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MOSI:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MOSI:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SPI:DATa:MOSI:VALue <QString>
- TRIGger:A:BUS:B<x>:SPI:DATa:MOSI:VALue?
Info
  • <QString> is the binary data string with the number of bits specified by the TRIGGER:A:BUS:BX:SPI:DATA:SIZE command. The only allowed characters in the QString are 0, 1, and X.

TriggerABusBItemSpiDataMosiValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:SPI:DATa:MOSI:VALue command.

Description
  • This command specifies the binary data string to be used for a SPI trigger if the trigger condition is MOSI or MISOMOSI. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MOSI:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MOSI:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MOSI:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SPI:DATa:MOSI:VALue <QString>
- TRIGger:A:BUS:B<x>:SPI:DATa:MOSI:VALue?
Info
  • <QString> is the binary data string with the number of bits specified by the TRIGGER:A:BUS:BX:SPI:DATA:SIZE command. The only allowed characters in the QString are 0, 1, and X.

TriggerABusBItemSpiDataOut

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:SPI:DATa:OUT command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:OUT? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:OUT? query and raise an AssertionError if the returned value does not match value.
Properties
  • .value: The TRIGger:A:BUS:B<x>:SPI:DATa:OUT:VALue command.

value property

Return the TRIGger:A:BUS:B<x>:SPI:DATa:OUT:VALue command.

Description
  • This command specifies the binary data string to be used for a SPI trigger if the trigger condition is MOSI or MISOMOSI. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:OUT:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:OUT:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:OUT:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SPI:DATa:OUT:VALue <QString>
- TRIGger:A:BUS:B<x>:SPI:DATa:OUT:VALue?
Info
  • <QString> is the binary data string with the number of bits specified by the TRIGGER:A:BUS:BX:SPI:DATA:SIZE command. The only allowed characters in the QString are 0, 1, and X.

TriggerABusBItemSpiDataOutValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:SPI:DATa:OUT:VALue command.

Description
  • This command specifies the binary data string to be used for a SPI trigger if the trigger condition is MOSI or MISOMOSI. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:OUT:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:OUT:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:OUT:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SPI:DATa:OUT:VALue <QString>
- TRIGger:A:BUS:B<x>:SPI:DATa:OUT:VALue?
Info
  • <QString> is the binary data string with the number of bits specified by the TRIGGER:A:BUS:BX:SPI:DATA:SIZE command. The only allowed characters in the QString are 0, 1, and X.

TriggerABusBItemSpiDataSize

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:SPI:DATa:SIZe command.

Description
  • This command specifies the length of the data string to be used for a SPI trigger if the trigger condition is DATa. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SPI:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:SPI:DATa:SIZe?
Info
  • <NR1> is the length of the data string in bytes.

TriggerABusBItemUsb

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:USB command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB? query and raise an AssertionError if the returned value does not match value.
Properties
  • .address: The TRIGger:A:BUS:B<x>:USB:ADDRess command tree.
  • .condition: The TRIGger:A:BUS:B<x>:USB:CONDition command.
  • .data: The TRIGger:A:BUS:B<x>:USB:DATa command tree.
  • .endpoint: The TRIGger:A:BUS:B<x>:USB:ENDPoint command tree.
  • .errtype: The TRIGger:A:BUS:B<x>:USB:ERRTYPE command.
  • .handshaketype: The TRIGger:A:BUS:B<x>:USB:HANDSHAKEType command.
  • .qualifier: The TRIGger:A:BUS:B<x>:USB:QUALifier command.
  • .sofframenumber: The TRIGger:A:BUS:B<x>:USB:SOFFRAMENUMber command.
  • .specialtype: The TRIGger:A:BUS:B<x>:USB:SPECIALType command.
  • .split: The TRIGger:A:BUS:B<x>:USB:SPLit command tree.
  • .tokentype: The TRIGger:A:BUS:B<x>:USB:TOKENType command.

address property

Return the TRIGger:A:BUS:B<x>:USB:ADDRess command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:ADDRess? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:ADDRess? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .hivalue: The TRIGger:A:BUS:B<x>:USB:ADDRess:HIVALue command.
  • .value: The TRIGger:A:BUS:B<x>:USB:ADDRess:VALue command.

condition property

Return the TRIGger:A:BUS:B<x>:USB:CONDition command.

Description
  • This command specifies the trigger condition for the USB trigger. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:CONDition {SYNC|RESET|SUSPEND|RESUME|EOP|TOKENPacket|DATAPacket|HANDSHAKEPacket|SPECIALPacket|ERRor}
- TRIGger:A:BUS:B<x>:USB:CONDition?
Info
  • SYNC indicates triggering on a Sync field of a packet.
  • RESET sets triggering on a reset condition.
  • SUSPEND sets triggering on a suspend condition.
  • RESUME sets triggering on a resume condition.
  • EOP indicates triggering on an end-of-packet signal.
  • TOKENPacket indicates triggering on a token packet.
  • DATAPacket indicates triggering on a data packet.
  • HANDSHAKEPacket indicates triggering on a handshake packet.
  • SPECIALPacket indicates triggering on a special status packet.
  • ERRor indicates triggering on an error condition.

data property

Return the TRIGger:A:BUS:B<x>:USB:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:DATa? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .hivalue: The TRIGger:A:BUS:B<x>:USB:DATa:HIVALue command.
  • .offset: The TRIGger:A:BUS:B<x>:USB:DATa:OFFSet command.
  • .size: The TRIGger:A:BUS:B<x>:USB:DATa:SIZe command.
  • .type: The TRIGger:A:BUS:B<x>:USB:DATa:TYPe command.
  • .value: The TRIGger:A:BUS:B<x>:USB:DATa:VALue command.

endpoint property

Return the TRIGger:A:BUS:B<x>:USB:ENDPoint command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:ENDPoint? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:ENDPoint? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .value: The TRIGger:A:BUS:B<x>:USB:ENDPoint:VALue command.

errtype property

Return the TRIGger:A:BUS:B<x>:USB:ERRTYPE command.

Description
  • This command specifies the error type to be used when the trigger condition is set to ERRor. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:ERRTYPE? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:ERRTYPE? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:ERRTYPE value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:ERRTYPE {PID|CRC5|CRC16|BITSTUFFing}
- TRIGger:A:BUS:B<x>:USB:ERRTYPE?
Info
  • PID indicates the error type is set to packet ID.
  • CRC5 indicates the error type is set to 5-bit CRC.
  • CRC16 indicates the error type is set to 16-bit CRC.
  • BITSTUFFing indicates the error type is set to bit stuffing.

handshaketype property

Return the TRIGger:A:BUS:B<x>:USB:HANDSHAKEType command.

Description
  • This command specifies the handshake type for the USB trigger. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:HANDSHAKEType? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:HANDSHAKEType? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:HANDSHAKEType value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:HANDSHAKEType {ANY|NAK|ACK|STALL}
- TRIGger:A:BUS:B<x>:USB:HANDSHAKEType?
Info
  • ANY indicates the oscilloscope will trigger on any handshake type.
  • NAK indicates the oscilloscope will trigger when a device cannot send or receive data.
  • ACK indicates the oscilloscope will trigger when a packet is successfully received.
  • STALL indicates the oscilloscope will trigger when a device requires intervention from the host.

qualifier property

Return the TRIGger:A:BUS:B<x>:USB:QUALifier command.

Description
  • This command specifies the USB trigger qualifier for address, endpoint and data. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:QUALifier {LESSthan|MOREthan|EQual|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:USB:QUALifier?
Info
  • LESSthan triggers on an input value that is less than a set value.
  • MOREthan triggers on an input value that is greater than a set value.
  • EQual triggers on an input value that is equal to a set value.
  • UNEQual triggers on an input value that is not equal to a set value.
  • LESSEQual triggers on an input value that is less than or equal to a set value.
  • MOREEQual triggers on an input value that is more than or equal to a set value.
  • INrange triggers on an input value that is within a range set by two values.
  • OUTrange triggers on an input value that is outside of a range set by two values.

sofframenumber property

Return the TRIGger:A:BUS:B<x>:USB:SOFFRAMENUMber command.

Description
  • This command specifies the binary data string to be used for start of frame number, when the trigger condition is Token Packet and the token type is Start of Frame. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:SOFFRAMENUMber? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:SOFFRAMENUMber? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:SOFFRAMENUMber value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:SOFFRAMENUMber <QString>
- TRIGger:A:BUS:B<x>:USB:SOFFRAMENUMber?
Info
  • <QString> within the range 000 0000 0000 to 111 1111 1111 (000 hex to 7FF hex).

specialtype property

Return the TRIGger:A:BUS:B<x>:USB:SPECIALType command.

Description
  • This command specifies the packet ID (PID) for the special packet. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:SPECIALType? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:SPECIALType? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:SPECIALType value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:SPECIALType {ANY|PREamble|RESERVed}
- TRIGger:A:BUS:B<x>:USB:SPECIALType?
Info
  • ANY indicates any type of special packet.
  • PREamble indicates a preamble special packet.
  • RESERVed indicates a reserved special packet.

split property

Return the TRIGger:A:BUS:B<x>:USB:SPLit command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:SPLit? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:SPLit? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .et: The TRIGger:A:BUS:B<x>:USB:SPLit:ET command tree.
  • .hub: The TRIGger:A:BUS:B<x>:USB:SPLit:HUB command tree.
  • .port: The TRIGger:A:BUS:B<x>:USB:SPLit:PORT command tree.
  • .sc: The TRIGger:A:BUS:B<x>:USB:SPLit:SC command tree.
  • .se: The TRIGger:A:BUS:B<x>:USB:SPLit:SE command tree.

tokentype property

Return the TRIGger:A:BUS:B<x>:USB:TOKENType command.

Description
  • This command specifies the token type for the USB trigger. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:TOKENType? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:TOKENType? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:TOKENType value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:TOKENType {ANY|SOF|OUT|IN|SETUP}
- TRIGger:A:BUS:B<x>:USB:TOKENType?
Info
  • ANY
  • SOF indicates a SOF (start-of-frame) token type.
  • OUT indicates an OUT token type.
  • IN indicates an IN token type.
  • SETUP indicates a SETUP token type.

TriggerABusBItemUsbAddress

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:USB:ADDRess command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:ADDRess? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:ADDRess? query and raise an AssertionError if the returned value does not match value.
Properties
  • .hivalue: The TRIGger:A:BUS:B<x>:USB:ADDRess:HIVALue command.
  • .value: The TRIGger:A:BUS:B<x>:USB:ADDRess:VALue command.

hivalue property

Return the TRIGger:A:BUS:B<x>:USB:ADDRess:HIVALue command.

Description
  • This command specifies the binary address string for the upper limit for inside-of-range and outside-of-range qualifiers for the USB trigger. Use the command TRIGGER:A:BUS:BX:USB:ADDRESS:VALUE to set the lower limit. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:ADDRess:HIVALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:ADDRess:HIVALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:ADDRess:HIVALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:ADDRess:HIVALue <QString>
- TRIGger:A:BUS:B<x>:USB:ADDRess:HIVALue?
Info
  • <QString> within the range 0000000 to 1111111 (00 hex to 7F hex).

value property

Return the TRIGger:A:BUS:B<x>:USB:ADDRess:VALue command.

Description
  • This command specifies the binary address string to be used for USB trigger. This command also specifies the binary address string for the lower limit for inside-of-range and outside-of-range qualifiers for the USB trigger. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:ADDRess:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:ADDRess:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:ADDRess:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:ADDRess:VALue <Qstring>
- TRIGger:A:BUS:B<x>:USB:ADDRess:VALue?
Info
  • <QString> within the range 0000000 to 1111111 (00 hex to 7F hex).

TriggerABusBItemUsbAddressHivalue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:USB:ADDRess:HIVALue command.

Description
  • This command specifies the binary address string for the upper limit for inside-of-range and outside-of-range qualifiers for the USB trigger. Use the command TRIGGER:A:BUS:BX:USB:ADDRESS:VALUE to set the lower limit. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:ADDRess:HIVALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:ADDRess:HIVALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:ADDRess:HIVALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:ADDRess:HIVALue <QString>
- TRIGger:A:BUS:B<x>:USB:ADDRess:HIVALue?
Info
  • <QString> within the range 0000000 to 1111111 (00 hex to 7F hex).

TriggerABusBItemUsbAddressValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:USB:ADDRess:VALue command.

Description
  • This command specifies the binary address string to be used for USB trigger. This command also specifies the binary address string for the lower limit for inside-of-range and outside-of-range qualifiers for the USB trigger. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:ADDRess:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:ADDRess:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:ADDRess:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:ADDRess:VALue <Qstring>
- TRIGger:A:BUS:B<x>:USB:ADDRess:VALue?
Info
  • <QString> within the range 0000000 to 1111111 (00 hex to 7F hex).

TriggerABusBItemUsbCondition

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:USB:CONDition command.

Description
  • This command specifies the trigger condition for the USB trigger. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:CONDition {SYNC|RESET|SUSPEND|RESUME|EOP|TOKENPacket|DATAPacket|HANDSHAKEPacket|SPECIALPacket|ERRor}
- TRIGger:A:BUS:B<x>:USB:CONDition?
Info
  • SYNC indicates triggering on a Sync field of a packet.
  • RESET sets triggering on a reset condition.
  • SUSPEND sets triggering on a suspend condition.
  • RESUME sets triggering on a resume condition.
  • EOP indicates triggering on an end-of-packet signal.
  • TOKENPacket indicates triggering on a token packet.
  • DATAPacket indicates triggering on a data packet.
  • HANDSHAKEPacket indicates triggering on a handshake packet.
  • SPECIALPacket indicates triggering on a special status packet.
  • ERRor indicates triggering on an error condition.

TriggerABusBItemUsbData

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:USB:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:DATa? query and raise an AssertionError if the returned value does not match value.
Properties
  • .hivalue: The TRIGger:A:BUS:B<x>:USB:DATa:HIVALue command.
  • .offset: The TRIGger:A:BUS:B<x>:USB:DATa:OFFSet command.
  • .size: The TRIGger:A:BUS:B<x>:USB:DATa:SIZe command.
  • .type: The TRIGger:A:BUS:B<x>:USB:DATa:TYPe command.
  • .value: The TRIGger:A:BUS:B<x>:USB:DATa:VALue command.

hivalue property

Return the TRIGger:A:BUS:B<x>:USB:DATa:HIVALue command.

Description
  • This command specifies the binary data string for the upper limit for inside-of-range and outside-of-range qualifiers for the USB trigger when the trigger condition is DATAPacket. Use the command TRIGGER:A:BUS:BX:USB:DATA:VALUE to set the lower limit. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:DATa:HIVALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:DATa:HIVALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:DATa:HIVALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:DATa:HIVALue <QString>
- TRIGger:A:BUS:B<x>:USB:DATa:HIVALue?
Info
  • <QString> within the range 00000000 to 11111111 (00 hex to FF hex).

offset property

Return the TRIGger:A:BUS:B<x>:USB:DATa:OFFSet command.

Description
  • This command specifies the data offset in bytes to trigger on. The minimum and default values are 0 and the maximum is 1024. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:DATa:OFFSet? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:DATa:OFFSet? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:DATa:OFFSet value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:DATa:OFFSet <NR1>
- TRIGger:A:BUS:B<x>:USB:DATa:OFFSet?

size property

Return the TRIGger:A:BUS:B<x>:USB:DATa:SIZe command.

Description
  • This command specifies the number of contiguous data bytes to trigger on. The minimum and default values are 1 and maximum is 16. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:USB:DATa:SIZe?

type property

Return the TRIGger:A:BUS:B<x>:USB:DATa:TYPe command.

Description
  • This command specifies the data type for when the trigger condition is set to DATAPacket. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:DATa:TYPe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:DATa:TYPe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:DATa:TYPe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:DATa:TYPe {ANY|DATA<x>}
- TRIGger:A:BUS:B<x>:USB:DATa:TYPe?
Info
  • ANY indicates either a DATA0 or DATA1 data packet type.
  • DATA0 indicates a DATA0 data packet type.
  • DATA1 indicates a DATA1 data packet type.

value property

Return the TRIGger:A:BUS:B<x>:USB:DATa:VALue command.

Description
  • This command specifies the binary data string to be used for the USB trigger when the trigger condition is DATAPacket. This command also specifies the binary data string for the lower limit for inside-of-range and outside-of-range qualifiers for the USB trigger when trigger condition is DATAPacket. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:DATa:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:USB:DATa:VALue?
Info
  • <QString> within the range 00000000 to 11111111 (00 hex to FF hex).

TriggerABusBItemUsbDataHivalue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:USB:DATa:HIVALue command.

Description
  • This command specifies the binary data string for the upper limit for inside-of-range and outside-of-range qualifiers for the USB trigger when the trigger condition is DATAPacket. Use the command TRIGGER:A:BUS:BX:USB:DATA:VALUE to set the lower limit. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:DATa:HIVALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:DATa:HIVALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:DATa:HIVALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:DATa:HIVALue <QString>
- TRIGger:A:BUS:B<x>:USB:DATa:HIVALue?
Info
  • <QString> within the range 00000000 to 11111111 (00 hex to FF hex).

TriggerABusBItemUsbDataOffset

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:USB:DATa:OFFSet command.

Description
  • This command specifies the data offset in bytes to trigger on. The minimum and default values are 0 and the maximum is 1024. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:DATa:OFFSet? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:DATa:OFFSet? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:DATa:OFFSet value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:DATa:OFFSet <NR1>
- TRIGger:A:BUS:B<x>:USB:DATa:OFFSet?

TriggerABusBItemUsbDataSize

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:USB:DATa:SIZe command.

Description
  • This command specifies the number of contiguous data bytes to trigger on. The minimum and default values are 1 and maximum is 16. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:USB:DATa:SIZe?

TriggerABusBItemUsbDataType

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:USB:DATa:TYPe command.

Description
  • This command specifies the data type for when the trigger condition is set to DATAPacket. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:DATa:TYPe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:DATa:TYPe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:DATa:TYPe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:DATa:TYPe {ANY|DATA<x>}
- TRIGger:A:BUS:B<x>:USB:DATa:TYPe?
Info
  • ANY indicates either a DATA0 or DATA1 data packet type.
  • DATA0 indicates a DATA0 data packet type.
  • DATA1 indicates a DATA1 data packet type.

TriggerABusBItemUsbDataValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:USB:DATa:VALue command.

Description
  • This command specifies the binary data string to be used for the USB trigger when the trigger condition is DATAPacket. This command also specifies the binary data string for the lower limit for inside-of-range and outside-of-range qualifiers for the USB trigger when trigger condition is DATAPacket. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:DATa:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:USB:DATa:VALue?
Info
  • <QString> within the range 00000000 to 11111111 (00 hex to FF hex).

TriggerABusBItemUsbEndpoint

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:USB:ENDPoint command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:ENDPoint? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:ENDPoint? query and raise an AssertionError if the returned value does not match value.
Properties
  • .value: The TRIGger:A:BUS:B<x>:USB:ENDPoint:VALue command.

value property

Return the TRIGger:A:BUS:B<x>:USB:ENDPoint:VALue command.

Description
  • This command specifies the binary endpoint string to be used for the USB trigger. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:ENDPoint:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:ENDPoint:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:ENDPoint:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:ENDPoint:VALue <QString>
- TRIGger:A:BUS:B<x>:USB:ENDPoint:VALue?
Info
  • <QString> within the range 0000 to 1111 (00 hex to 0F hex).

TriggerABusBItemUsbEndpointValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:USB:ENDPoint:VALue command.

Description
  • This command specifies the binary endpoint string to be used for the USB trigger. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:ENDPoint:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:ENDPoint:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:ENDPoint:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:ENDPoint:VALue <QString>
- TRIGger:A:BUS:B<x>:USB:ENDPoint:VALue?
Info
  • <QString> within the range 0000 to 1111 (00 hex to 0F hex).

TriggerABusBItemUsbErrtype

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:USB:ERRTYPE command.

Description
  • This command specifies the error type to be used when the trigger condition is set to ERRor. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:ERRTYPE? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:ERRTYPE? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:ERRTYPE value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:ERRTYPE {PID|CRC5|CRC16|BITSTUFFing}
- TRIGger:A:BUS:B<x>:USB:ERRTYPE?
Info
  • PID indicates the error type is set to packet ID.
  • CRC5 indicates the error type is set to 5-bit CRC.
  • CRC16 indicates the error type is set to 16-bit CRC.
  • BITSTUFFing indicates the error type is set to bit stuffing.

TriggerABusBItemUsbHandshaketype

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:USB:HANDSHAKEType command.

Description
  • This command specifies the handshake type for the USB trigger. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:HANDSHAKEType? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:HANDSHAKEType? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:HANDSHAKEType value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:HANDSHAKEType {ANY|NAK|ACK|STALL}
- TRIGger:A:BUS:B<x>:USB:HANDSHAKEType?
Info
  • ANY indicates the oscilloscope will trigger on any handshake type.
  • NAK indicates the oscilloscope will trigger when a device cannot send or receive data.
  • ACK indicates the oscilloscope will trigger when a packet is successfully received.
  • STALL indicates the oscilloscope will trigger when a device requires intervention from the host.

TriggerABusBItemUsbQualifier

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:USB:QUALifier command.

Description
  • This command specifies the USB trigger qualifier for address, endpoint and data. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:QUALifier {LESSthan|MOREthan|EQual|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:USB:QUALifier?
Info
  • LESSthan triggers on an input value that is less than a set value.
  • MOREthan triggers on an input value that is greater than a set value.
  • EQual triggers on an input value that is equal to a set value.
  • UNEQual triggers on an input value that is not equal to a set value.
  • LESSEQual triggers on an input value that is less than or equal to a set value.
  • MOREEQual triggers on an input value that is more than or equal to a set value.
  • INrange triggers on an input value that is within a range set by two values.
  • OUTrange triggers on an input value that is outside of a range set by two values.

TriggerABusBItemUsbSofframenumber

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:USB:SOFFRAMENUMber command.

Description
  • This command specifies the binary data string to be used for start of frame number, when the trigger condition is Token Packet and the token type is Start of Frame. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:SOFFRAMENUMber? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:SOFFRAMENUMber? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:SOFFRAMENUMber value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:SOFFRAMENUMber <QString>
- TRIGger:A:BUS:B<x>:USB:SOFFRAMENUMber?
Info
  • <QString> within the range 000 0000 0000 to 111 1111 1111 (000 hex to 7FF hex).

TriggerABusBItemUsbSpecialtype

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:USB:SPECIALType command.

Description
  • This command specifies the packet ID (PID) for the special packet. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:SPECIALType? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:SPECIALType? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:SPECIALType value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:SPECIALType {ANY|PREamble|RESERVed}
- TRIGger:A:BUS:B<x>:USB:SPECIALType?
Info
  • ANY indicates any type of special packet.
  • PREamble indicates a preamble special packet.
  • RESERVed indicates a reserved special packet.

TriggerABusBItemUsbSplit

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:USB:SPLit command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:SPLit? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:SPLit? query and raise an AssertionError if the returned value does not match value.
Properties
  • .et: The TRIGger:A:BUS:B<x>:USB:SPLit:ET command tree.
  • .hub: The TRIGger:A:BUS:B<x>:USB:SPLit:HUB command tree.
  • .port: The TRIGger:A:BUS:B<x>:USB:SPLit:PORT command tree.
  • .sc: The TRIGger:A:BUS:B<x>:USB:SPLit:SC command tree.
  • .se: The TRIGger:A:BUS:B<x>:USB:SPLit:SE command tree.

et property

Return the TRIGger:A:BUS:B<x>:USB:SPLit:ET command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:SPLit:ET? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:SPLit:ET? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .value: The TRIGger:A:BUS:B<x>:USB:SPLit:ET:VALue command.

hub property

Return the TRIGger:A:BUS:B<x>:USB:SPLit:HUB command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:SPLit:HUB? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:SPLit:HUB? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .value: The TRIGger:A:BUS:B<x>:USB:SPLit:HUB:VALue command.

port property

Return the TRIGger:A:BUS:B<x>:USB:SPLit:PORT command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:SPLit:PORT? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:SPLit:PORT? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .value: The TRIGger:A:BUS:B<x>:USB:SPLit:PORT:VALue command.

sc property

Return the TRIGger:A:BUS:B<x>:USB:SPLit:SC command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:SPLit:SC? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:SPLit:SC? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .value: The TRIGger:A:BUS:B<x>:USB:SPLit:SC:VALue command.

se property

Return the TRIGger:A:BUS:B<x>:USB:SPLit:SE command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:SPLit:SE? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:SPLit:SE? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .value: The TRIGger:A:BUS:B<x>:USB:SPLit:SE:VALue command.

TriggerABusBItemUsbSplitEt

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:USB:SPLit:ET command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:SPLit:ET? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:SPLit:ET? query and raise an AssertionError if the returned value does not match value.
Properties
  • .value: The TRIGger:A:BUS:B<x>:USB:SPLit:ET:VALue command.

value property

Return the TRIGger:A:BUS:B<x>:USB:SPLit:ET:VALue command.

Description
  • When triggering on a high-speed USB split transaction, this command specifies the split transaction endpoint type value to trigger on. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:SPLit:ET:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:SPLit:ET:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:SPLit:ET:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:SPLit:ET:VALue {NOCARE|CONTRol|ISOchronous|BULK|INTERRUPT}
- TRIGger:A:BUS:B<x>:USB:SPLit:ET:VALue?
Info
  • NOCARE - any endpoint type.
  • CONTRol - control endpoint type.
  • ISOchronous - isochronous endpoint type.
  • BULK - bulk endpoint type (BULK-IN or BULK-OUT).
  • INTERRUPT - interrupt endpoint type (Interrupt-IN).

TriggerABusBItemUsbSplitEtValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:USB:SPLit:ET:VALue command.

Description
  • When triggering on a high-speed USB split transaction, this command specifies the split transaction endpoint type value to trigger on. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:SPLit:ET:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:SPLit:ET:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:SPLit:ET:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:SPLit:ET:VALue {NOCARE|CONTRol|ISOchronous|BULK|INTERRUPT}
- TRIGger:A:BUS:B<x>:USB:SPLit:ET:VALue?
Info
  • NOCARE - any endpoint type.
  • CONTRol - control endpoint type.
  • ISOchronous - isochronous endpoint type.
  • BULK - bulk endpoint type (BULK-IN or BULK-OUT).
  • INTERRUPT - interrupt endpoint type (Interrupt-IN).

TriggerABusBItemUsbSplitHub

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:USB:SPLit:HUB command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:SPLit:HUB? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:SPLit:HUB? query and raise an AssertionError if the returned value does not match value.
Properties
  • .value: The TRIGger:A:BUS:B<x>:USB:SPLit:HUB:VALue command.

value property

Return the TRIGger:A:BUS:B<x>:USB:SPLit:HUB:VALue command.

Description
  • When triggering on a high-speed USB split transaction, this command specifies the split transaction hub address value to trigger on. The value can be up to 7 characters long. The default is all X’s (don’t care). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:SPLit:HUB:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:SPLit:HUB:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:SPLit:HUB:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:SPLit:HUB:VALue <QString>
- TRIGger:A:BUS:B<x>:USB:SPLit:HUB:VALue?
Info
  • QString is a quoted string of up to 7 characters. The valid characters are 0 and 1.

TriggerABusBItemUsbSplitHubValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:USB:SPLit:HUB:VALue command.

Description
  • When triggering on a high-speed USB split transaction, this command specifies the split transaction hub address value to trigger on. The value can be up to 7 characters long. The default is all X’s (don’t care). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:SPLit:HUB:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:SPLit:HUB:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:SPLit:HUB:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:SPLit:HUB:VALue <QString>
- TRIGger:A:BUS:B<x>:USB:SPLit:HUB:VALue?
Info
  • QString is a quoted string of up to 7 characters. The valid characters are 0 and 1.

TriggerABusBItemUsbSplitPort

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:USB:SPLit:PORT command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:SPLit:PORT? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:SPLit:PORT? query and raise an AssertionError if the returned value does not match value.
Properties
  • .value: The TRIGger:A:BUS:B<x>:USB:SPLit:PORT:VALue command.

value property

Return the TRIGger:A:BUS:B<x>:USB:SPLit:PORT:VALue command.

Description
  • When triggering on a high-speed USB split transaction, this command specifies the split transaction port address value to trigger on. The value can be up to 7 characters long. The default is all X’s (don’t care). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:SPLit:PORT:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:SPLit:PORT:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:SPLit:PORT:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:SPLit:PORT:VALue <QString>
- TRIGger:A:BUS:B<x>:USB:SPLit:PORT:VALue?
Info
  • QString is a quoted string of up to 7 characters. The valid characters are 0 and 1.

TriggerABusBItemUsbSplitPortValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:USB:SPLit:PORT:VALue command.

Description
  • When triggering on a high-speed USB split transaction, this command specifies the split transaction port address value to trigger on. The value can be up to 7 characters long. The default is all X’s (don’t care). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:SPLit:PORT:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:SPLit:PORT:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:SPLit:PORT:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:SPLit:PORT:VALue <QString>
- TRIGger:A:BUS:B<x>:USB:SPLit:PORT:VALue?
Info
  • QString is a quoted string of up to 7 characters. The valid characters are 0 and 1.

TriggerABusBItemUsbSplitSc

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:USB:SPLit:SC command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:SPLit:SC? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:SPLit:SC? query and raise an AssertionError if the returned value does not match value.
Properties
  • .value: The TRIGger:A:BUS:B<x>:USB:SPLit:SC:VALue command.

value property

Return the TRIGger:A:BUS:B<x>:USB:SPLit:SC:VALue command.

Description
  • When triggering on a high-speed USB split transaction, this command specifies whether to trigger on the start or complete phase of the split transaction, based on the Start/Complete bit field value. (0 = Start, 1 = Complete). The default is NOCARE. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:SPLit:SC:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:SPLit:SC:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:SPLit:SC:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:SPLit:SC:VALue {NOCARE|SSPLIT|CSPLIT}
- TRIGger:A:BUS:B<x>:USB:SPLit:SC:VALue?
Info
  • NOCARE - trigger on either the start or complete phase of the split transaction.
  • SSPLIT - trigger on the start phase of the split transaction.
  • CSPLIT - trigger on the complete phase of the split transaction.

TriggerABusBItemUsbSplitScValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:USB:SPLit:SC:VALue command.

Description
  • When triggering on a high-speed USB split transaction, this command specifies whether to trigger on the start or complete phase of the split transaction, based on the Start/Complete bit field value. (0 = Start, 1 = Complete). The default is NOCARE. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:SPLit:SC:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:SPLit:SC:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:SPLit:SC:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:SPLit:SC:VALue {NOCARE|SSPLIT|CSPLIT}
- TRIGger:A:BUS:B<x>:USB:SPLit:SC:VALue?
Info
  • NOCARE - trigger on either the start or complete phase of the split transaction.
  • SSPLIT - trigger on the start phase of the split transaction.
  • CSPLIT - trigger on the complete phase of the split transaction.

TriggerABusBItemUsbSplitSe

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:USB:SPLit:SE command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:SPLit:SE? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:SPLit:SE? query and raise an AssertionError if the returned value does not match value.
Properties
  • .value: The TRIGger:A:BUS:B<x>:USB:SPLit:SE:VALue command.

value property

Return the TRIGger:A:BUS:B<x>:USB:SPLit:SE:VALue command.

Description
  • When triggering on a high-speed USB split transaction, this command specifies the split transaction start/end bit value to trigger on. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:SPLit:SE:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:SPLit:SE:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:SPLit:SE:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:SPLit:SE:VALue {NOCARE|FULLSPeed|LOWSPeed|ISOSTART|ISOMID|ISOEND|ISOALL}
- TRIGger:A:BUS:B<x>:USB:SPLit:SE:VALue?
Info
  • NOCARE - any combination of S and E bits.
  • FULLSPeed - S bit = 0, E bit = 0.
  • LOWSPeed - S bit = 1, E bit = 0.
  • ISOSTART - S bit = 1, E bit = 0.
  • ISOMID - see note above.
  • ISOEND - see note above.
  • ISOALL - see note above.

TriggerABusBItemUsbSplitSeValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:USB:SPLit:SE:VALue command.

Description
  • When triggering on a high-speed USB split transaction, this command specifies the split transaction start/end bit value to trigger on. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:SPLit:SE:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:SPLit:SE:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:SPLit:SE:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:SPLit:SE:VALue {NOCARE|FULLSPeed|LOWSPeed|ISOSTART|ISOMID|ISOEND|ISOALL}
- TRIGger:A:BUS:B<x>:USB:SPLit:SE:VALue?
Info
  • NOCARE - any combination of S and E bits.
  • FULLSPeed - S bit = 0, E bit = 0.
  • LOWSPeed - S bit = 1, E bit = 0.
  • ISOSTART - S bit = 1, E bit = 0.
  • ISOMID - see note above.
  • ISOEND - see note above.
  • ISOALL - see note above.

TriggerABusBItemUsbTokentype

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:USB:TOKENType command.

Description
  • This command specifies the token type for the USB trigger. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:USB:TOKENType? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:USB:TOKENType? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:USB:TOKENType value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:USB:TOKENType {ANY|SOF|OUT|IN|SETUP}
- TRIGger:A:BUS:B<x>:USB:TOKENType?
Info
  • ANY
  • SOF indicates a SOF (start-of-frame) token type.
  • OUT indicates an OUT token type.
  • IN indicates an IN token type.
  • SETUP indicates a SETUP token type.

TriggerABusSource

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:SOUrce command.

Description
  • This command specifies the source for a serial or parallel bus trigger, with the appropriate application module installed.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:SOUrce value command.
SCPI Syntax
- TRIGger:A:BUS:SOUrce {B<x>}
- TRIGger:A:BUS:SOUrce?
Info
  • B1 specifies the Bus 1 source.
  • B2 specifies the Bus 2 source.
  • B3 specifies the Bus 3 source.
  • B4 specifies the Bus 4 source.

TriggerAEdge

Bases: SCPICmdRead

The TRIGger:A:EDGE command.

Description
  • Returns the trigger source, coupling, and slope for the A edge trigger.
Usage
  • Using the .query() method will send the TRIGger:A:EDGE? query.
  • Using the .verify(value) method will send the TRIGger:A:EDGE? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:EDGE?
Properties
  • .coupling: The TRIGger:A:EDGE:COUPling command.
  • .slope: The TRIGger:A:EDGE:SLOpe command.
  • .source: The TRIGger:A:EDGE:SOUrce command.

coupling property

Return the TRIGger:A:EDGE:COUPling command.

Description
  • This command specifies the type of coupling for the A edge trigger.
Usage
  • Using the .query() method will send the TRIGger:A:EDGE:COUPling? query.
  • Using the .verify(value) method will send the TRIGger:A:EDGE:COUPling? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:EDGE:COUPling value command.
SCPI Syntax
- TRIGger:A:EDGE:COUPling {AC|DC|HFRej|LFRej|NOISErej}
- TRIGger:A:EDGE:COUPling?
Info
  • AC specifies AC trigger coupling.
  • DC specifies DC trigger coupling, which passes all input signals to the trigger circuitry.
  • HFRej specifies high-frequency rejection coupling, which attenuates signals above 50 kHz before passing the signals to the trigger circuitry.
  • LFRej specifies low-frequency rejection coupling, which attenuates signals below 50 kHz before passing the signals to the trigger circuitry.
  • NOISErej specifies noise-rejection coupling, which provides stable triggering by increasing the trigger hysteresis. Increased hysteresis reduces the trigger sensitivity to noise but may require greater trigger signal amplitude.

slope property

Return the TRIGger:A:EDGE:SLOpe command.

Description
  • This command specifies the slope for the A edge trigger: rising, falling or either.
Usage
  • Using the .query() method will send the TRIGger:A:EDGE:SLOpe? query.
  • Using the .verify(value) method will send the TRIGger:A:EDGE:SLOpe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:EDGE:SLOpe value command.
SCPI Syntax
- TRIGger:A:EDGE:SLOpe {RISe|FALL|EITHer}
- TRIGger:A:EDGE:SLOpe?
Info
  • RISe specifies to trigger on the rising or positive edge of a signal.
  • FALL specifies to trigger on the falling or negative edge of a signal.
  • EITHer specifies to trigger on either the rising or falling edge of a signal.

source property

Return the TRIGger:A:EDGE:SOUrce command.

Description
  • This command specifies the source for the A edge trigger.
Usage
  • Using the .query() method will send the TRIGger:A:EDGE:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:EDGE:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:EDGE:SOUrce value command.
SCPI Syntax
- TRIGger:A:EDGE:SOUrce {AUX|CH<x>|D<x>|LINE|RF}
- TRIGger:A:EDGE:SOUrce?
Info
  • AUX specifies an external trigger using the auxiliary input connector located on the front panel of the oscilloscope. (For 2-channel MDO32 model only.).
  • CH<x> specifies an analog input channel as the A edge trigger source.
  • D<x> specifies a digital channel as the source (only with option 3-MSO installed).
  • LINE specifies the AC power line as the trigger source.

TriggerAEdgeCoupling

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:EDGE:COUPling command.

Description
  • This command specifies the type of coupling for the A edge trigger.
Usage
  • Using the .query() method will send the TRIGger:A:EDGE:COUPling? query.
  • Using the .verify(value) method will send the TRIGger:A:EDGE:COUPling? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:EDGE:COUPling value command.
SCPI Syntax
- TRIGger:A:EDGE:COUPling {AC|DC|HFRej|LFRej|NOISErej}
- TRIGger:A:EDGE:COUPling?
Info
  • AC specifies AC trigger coupling.
  • DC specifies DC trigger coupling, which passes all input signals to the trigger circuitry.
  • HFRej specifies high-frequency rejection coupling, which attenuates signals above 50 kHz before passing the signals to the trigger circuitry.
  • LFRej specifies low-frequency rejection coupling, which attenuates signals below 50 kHz before passing the signals to the trigger circuitry.
  • NOISErej specifies noise-rejection coupling, which provides stable triggering by increasing the trigger hysteresis. Increased hysteresis reduces the trigger sensitivity to noise but may require greater trigger signal amplitude.

TriggerAEdgeSlope

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:EDGE:SLOpe command.

Description
  • This command specifies the slope for the A edge trigger: rising, falling or either.
Usage
  • Using the .query() method will send the TRIGger:A:EDGE:SLOpe? query.
  • Using the .verify(value) method will send the TRIGger:A:EDGE:SLOpe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:EDGE:SLOpe value command.
SCPI Syntax
- TRIGger:A:EDGE:SLOpe {RISe|FALL|EITHer}
- TRIGger:A:EDGE:SLOpe?
Info
  • RISe specifies to trigger on the rising or positive edge of a signal.
  • FALL specifies to trigger on the falling or negative edge of a signal.
  • EITHer specifies to trigger on either the rising or falling edge of a signal.

TriggerAEdgeSource

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:EDGE:SOUrce command.

Description
  • This command specifies the source for the A edge trigger.
Usage
  • Using the .query() method will send the TRIGger:A:EDGE:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:EDGE:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:EDGE:SOUrce value command.
SCPI Syntax
- TRIGger:A:EDGE:SOUrce {AUX|CH<x>|D<x>|LINE|RF}
- TRIGger:A:EDGE:SOUrce?
Info
  • AUX specifies an external trigger using the auxiliary input connector located on the front panel of the oscilloscope. (For 2-channel MDO32 model only.).
  • CH<x> specifies an analog input channel as the A edge trigger source.
  • D<x> specifies a digital channel as the source (only with option 3-MSO installed).
  • LINE specifies the AC power line as the trigger source.

TriggerAHoldoff

Bases: SCPICmdRead

The TRIGger:A:HOLDoff command.

Description
  • Returns the A trigger holdoff parameters. These parameters specify the time period during which the trigger circuitry is not looking to generate a trigger event.
Usage
  • Using the .query() method will send the TRIGger:A:HOLDoff? query.
  • Using the .verify(value) method will send the TRIGger:A:HOLDoff? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:HOLDoff?
Properties
  • .time: The TRIGger:A:HOLDoff:TIMe command.

time property

Return the TRIGger:A:HOLDoff:TIMe command.

Description
  • This command sets or queries the A trigger holdoff time. This command is equivalent to selecting Mode & Holdoff from the Trig menu, selecting Time, and then setting the desired Holdoff Time.
Usage
  • Using the .query() method will send the TRIGger:A:HOLDoff:TIMe? query.
  • Using the .verify(value) method will send the TRIGger:A:HOLDoff:TIMe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:HOLDoff:TIMe value command.
SCPI Syntax
- TRIGger:A:HOLDoff:TIMe <NR3>
- TRIGger:A:HOLDoff:TIMe?
Info
  • <NR3> specifies the holdoff time in seconds. The range is from 0 seconds through 10 seconds.

TriggerAHoldoffTime

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:HOLDoff:TIMe command.

Description
  • This command sets or queries the A trigger holdoff time. This command is equivalent to selecting Mode & Holdoff from the Trig menu, selecting Time, and then setting the desired Holdoff Time.
Usage
  • Using the .query() method will send the TRIGger:A:HOLDoff:TIMe? query.
  • Using the .verify(value) method will send the TRIGger:A:HOLDoff:TIMe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:HOLDoff:TIMe value command.
SCPI Syntax
- TRIGger:A:HOLDoff:TIMe <NR3>
- TRIGger:A:HOLDoff:TIMe?
Info
  • <NR3> specifies the holdoff time in seconds. The range is from 0 seconds through 10 seconds.

TriggerALevel

Bases: SCPICmdRead

The TRIGger:A:LEVel command tree.

Usage
  • Using the .query() method will send the TRIGger:A:LEVel? query.
  • Using the .verify(value) method will send the TRIGger:A:LEVel? query and raise an AssertionError if the returned value does not match value.
Properties
  • .auxin: The TRIGger:A:LEVel:AUXin command.
  • .ch: The TRIGger:A:LEVel:CH<x> command.
  • .d: The TRIGger:A:LEVel:D<x> command.

auxin property

Return the TRIGger:A:LEVel:AUXin command.

Description
  • This command sets the threshold voltage level to use for an Edge, Pulse Width, Runt or Rise/Fall (aka Transition, aka Slew Rate) trigger when triggering on the Aux Input connector signal.
Usage
  • Using the .query() method will send the TRIGger:A:LEVel:AUXin? query.
  • Using the .verify(value) method will send the TRIGger:A:LEVel:AUXin? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LEVel:AUXin value command.
SCPI Syntax
- TRIGger:A:LEVel:AUXin {<NR3>|ECL|TTL}
- TRIGger:A:LEVel:AUXin?
Info
  • <NR3> is a floating point number that sets the trigger threshold level, in Volts, for the Aux Input connector.
  • ECL sets the threshold level to a preset ECL high level of -1.3V.
  • TTL sets the threshold level to a preset TTL high level of 1.4V.

ch property

Return the TRIGger:A:LEVel:CH<x> command.

Description
  • This command sets the threshold voltage level to use for an Edge, Pulse Width, Runt or Rise/Fall (aka Transition, aka Slew Rate) trigger when triggering on an analog channel waveform. x can be 1 - 4. Each channel can have an independent trigger level.
Usage
  • Using the .query() method will send the TRIGger:A:LEVel:CH<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LEVel:CH<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LEVel:CH<x> value command.
SCPI Syntax
- TRIGger:A:LEVel:CH<x> {<NR3>|ECL|TTL}
- TRIGger:A:LEVel:CH<x>?
Info
  • <NR3> is a floating point number that sets the trigger threshold level, in Volts, for the specified analog channel.
  • ECL sets the threshold level to a preset ECL high level of -1.3V.
  • TTL sets the threshold level to a preset TTL high level of 1.4V.

d property

Return the TRIGger:A:LEVel:D<x> command.

Description
  • This command sets the threshold voltage level to use for an Edge or Pulse Width trigger when triggering on a digital channel waveform. can be 1 - 16. Each channel can have an independent trigger level.
Usage
  • Using the .query() method will send the TRIGger:A:LEVel:D<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LEVel:D<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LEVel:D<x> value command.
SCPI Syntax
- TRIGger:A:LEVel:D<x> {<NR3>|ECL|TTL}
- TRIGger:A:LEVel:D<x>?
Info
  • <NR3> is a floating point number that sets the trigger threshold level, in Volts, for the specified digital channel.
  • ECL sets the threshold level to a preset ECL high level of -1.3V.
  • TTL sets the threshold level to a preset TTL high level of 1.4V.

TriggerALevelAuxin

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:LEVel:AUXin command.

Description
  • This command sets the threshold voltage level to use for an Edge, Pulse Width, Runt or Rise/Fall (aka Transition, aka Slew Rate) trigger when triggering on the Aux Input connector signal.
Usage
  • Using the .query() method will send the TRIGger:A:LEVel:AUXin? query.
  • Using the .verify(value) method will send the TRIGger:A:LEVel:AUXin? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LEVel:AUXin value command.
SCPI Syntax
- TRIGger:A:LEVel:AUXin {<NR3>|ECL|TTL}
- TRIGger:A:LEVel:AUXin?
Info
  • <NR3> is a floating point number that sets the trigger threshold level, in Volts, for the Aux Input connector.
  • ECL sets the threshold level to a preset ECL high level of -1.3V.
  • TTL sets the threshold level to a preset TTL high level of 1.4V.

TriggerALevelChannel

Bases: ValidatedChannel, SCPICmdWrite, SCPICmdRead

The TRIGger:A:LEVel:CH<x> command.

Description
  • This command sets the threshold voltage level to use for an Edge, Pulse Width, Runt or Rise/Fall (aka Transition, aka Slew Rate) trigger when triggering on an analog channel waveform. x can be 1 - 4. Each channel can have an independent trigger level.
Usage
  • Using the .query() method will send the TRIGger:A:LEVel:CH<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LEVel:CH<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LEVel:CH<x> value command.
SCPI Syntax
- TRIGger:A:LEVel:CH<x> {<NR3>|ECL|TTL}
- TRIGger:A:LEVel:CH<x>?
Info
  • <NR3> is a floating point number that sets the trigger threshold level, in Volts, for the specified analog channel.
  • ECL sets the threshold level to a preset ECL high level of -1.3V.
  • TTL sets the threshold level to a preset TTL high level of 1.4V.

TriggerALevelDigitalBit

Bases: ValidatedDigitalBit, SCPICmdWrite, SCPICmdRead

The TRIGger:A:LEVel:D<x> command.

Description
  • This command sets the threshold voltage level to use for an Edge or Pulse Width trigger when triggering on a digital channel waveform. can be 1 - 16. Each channel can have an independent trigger level.
Usage
  • Using the .query() method will send the TRIGger:A:LEVel:D<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LEVel:D<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LEVel:D<x> value command.
SCPI Syntax
- TRIGger:A:LEVel:D<x> {<NR3>|ECL|TTL}
- TRIGger:A:LEVel:D<x>?
Info
  • <NR3> is a floating point number that sets the trigger threshold level, in Volts, for the specified digital channel.
  • ECL sets the threshold level to a preset ECL high level of -1.3V.
  • TTL sets the threshold level to a preset TTL high level of 1.4V.

TriggerALogic

Bases: SCPICmdRead

The TRIGger:A:LOGIc command.

Description
  • Returns all of the A logic trigger parameters.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:LOGIc?
Properties
  • .class: The TRIGger:A:LOGIc:CLAss command.
  • .function: The TRIGger:A:LOGIc:FUNCtion command.
  • .input: The TRIGger:A:LOGIc:INPut command.
  • .pattern: The TRIGger:A:LOGIc:PATtern command.
  • .threshold: The TRIGger:A:LOGIc:THReshold command tree.

class_ property

Return the TRIGger:A:LOGIc:CLAss command.

Description
  • This command specifies what kind of logic trigger to use (either logic or setup/hold). You also need to set the trigger type to LOGIC using the command TRIGGER:A:TYPE. The LOGIC argument sets the oscilloscope to trigger on logical combinations of the channels (set using the TRIGger:A:LOGIc:INPut commands as well as TRIGGER:A:LOGIC:FUNCTION). You can use up to 20 channels for a logic trigger (4 analog and 16 digital). You can perform logic triggering using a clock; when TRIGGER:A:LOGIC:INPUT:CLOCK:SOURCE is set to one of the channels, the oscilloscope triggers when the specified logical combination of the remaining channels is true during a transition on the clock channel. You can also perform logic triggering without using a clock (by setting TRIGGER:A:LOGIC:INPUT:CLOCK:SOURCE to NONE ), so that the oscilloscope triggers when the specified logical combination of data channels is met. Without a clock, you can also use the command TRIGGER:A:LOGIC:PATTERN:DELTATIME. The SETHold argument sets the oscilloscope to trigger on setup and hold violations between a data source and a clock source. The clocking and data levels are used to determine if a clock or data transition has occurred. You can use up to 20 channels as Setup and Hold trigger data sources (4 analog and 16 digital) using TRIGGER:A:SETHOLD:DATA:SOURCE. You can use one channel input as the clock signal (TRIGGER:A:SETHOLD:CLOCK:SOURCE). The data sources cannot include the waveform specified for the clock source.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:CLAss? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:CLAss? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:CLAss value command.
SCPI Syntax
- TRIGger:A:LOGIc:CLAss {LOGIC|SETHold}
- TRIGger:A:LOGIc:CLAss?
Info
  • LOGIC - Use with the commands TRIGGER:A:LOGIC:FUNCTION, TRIGGER:A:LOGIC:INPUT:CHX, TRIGGER:A:LOGIC:INPUT:CLOCK:EDGE, TRIGGER:A:LOGIC:INPUT:CLOCK:SOURCE, TRIGGER:A:LOGIC:INPUT:DX, and TRIGGER:A:LOGIC:INPUT:RF. If you would like to use the logic trigger without a clock, you can also use the command TRIGGER:A:LOGIC:PATTERN:DELTATIME.
  • SETHold - Use with the commands TRIGGER:A:SETHOLD:CLOCK:EDGE, TRIGGER:A:SETHOLD:CLOCK:SOURCE, TRIGGER:A:SETHOLD:CLOCK:THRESHOLD, TRIGGER:A:SETHOLD:DATA:SOURCE.

function property

Return the TRIGger:A:LOGIc:FUNCtion command.

Description
  • This command sets or queries the logical combination of the input channels for logic triggers. This command is equivalent to selecting Logic for the Trigger Type, and setting or viewing the Define Logic.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:FUNCtion? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:FUNCtion? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:FUNCtion value command.
SCPI Syntax
- TRIGger:A:LOGIc:FUNCtion {AND|NANd|NOR|OR}
- TRIGger:A:LOGIc:FUNCtion?
Info
  • AND specifies to trigger if all conditions are true.
  • NANd specifies to trigger if any of the conditions are false.
  • NOR specifies to trigger if all conditions are false.
  • OR specifies to trigger if any of the conditions are true.

input property

Return the TRIGger:A:LOGIc:INPut command.

Description
  • Returns the logic input values for all channels. If a clock channel is defined, it returns the clock source and edge.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:INPut? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:INPut? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:LOGIc:INPut?
Sub-properties
  • .ch: The TRIGger:A:LOGIc:INPut:CH<x> command.
  • .clock: The TRIGger:A:LOGIc:INPut:CLOCk command tree.
  • .d: The TRIGger:A:LOGIc:INPut:D<x> command.
  • .rf: The TRIGger:A:LOGIc:INPut:RF command.

pattern property

Return the TRIGger:A:LOGIc:PATtern command.

Description
  • Returns the conditions used for generating an A logic pattern trigger, with respect to the defined input pattern, and identifies the time that the selected pattern may be true and still generate the trigger.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:PATtern? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:PATtern? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:LOGIc:PATtern?
Sub-properties
  • .deltatime: The TRIGger:A:LOGIc:PATtern:DELTatime command.
  • .when: The TRIGger:A:LOGIc:PATtern:WHEn command.

threshold property

Return the TRIGger:A:LOGIc:THReshold command tree.

Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:THReshold? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:THReshold? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .ch: The TRIGger:A:LOGIc:THReshold:CH<x> command.
  • .d: The TRIGger:A:LOGIc:THReshold:D<x> command.
  • .rf: The TRIGger:A:LOGIc:THReshold:RF command.

TriggerALogicClass

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOGIc:CLAss command.

Description
  • This command specifies what kind of logic trigger to use (either logic or setup/hold). You also need to set the trigger type to LOGIC using the command TRIGGER:A:TYPE. The LOGIC argument sets the oscilloscope to trigger on logical combinations of the channels (set using the TRIGger:A:LOGIc:INPut commands as well as TRIGGER:A:LOGIC:FUNCTION). You can use up to 20 channels for a logic trigger (4 analog and 16 digital). You can perform logic triggering using a clock; when TRIGGER:A:LOGIC:INPUT:CLOCK:SOURCE is set to one of the channels, the oscilloscope triggers when the specified logical combination of the remaining channels is true during a transition on the clock channel. You can also perform logic triggering without using a clock (by setting TRIGGER:A:LOGIC:INPUT:CLOCK:SOURCE to NONE ), so that the oscilloscope triggers when the specified logical combination of data channels is met. Without a clock, you can also use the command TRIGGER:A:LOGIC:PATTERN:DELTATIME. The SETHold argument sets the oscilloscope to trigger on setup and hold violations between a data source and a clock source. The clocking and data levels are used to determine if a clock or data transition has occurred. You can use up to 20 channels as Setup and Hold trigger data sources (4 analog and 16 digital) using TRIGGER:A:SETHOLD:DATA:SOURCE. You can use one channel input as the clock signal (TRIGGER:A:SETHOLD:CLOCK:SOURCE). The data sources cannot include the waveform specified for the clock source.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:CLAss? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:CLAss? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:CLAss value command.
SCPI Syntax
- TRIGger:A:LOGIc:CLAss {LOGIC|SETHold}
- TRIGger:A:LOGIc:CLAss?
Info
  • LOGIC - Use with the commands TRIGGER:A:LOGIC:FUNCTION, TRIGGER:A:LOGIC:INPUT:CHX, TRIGGER:A:LOGIC:INPUT:CLOCK:EDGE, TRIGGER:A:LOGIC:INPUT:CLOCK:SOURCE, TRIGGER:A:LOGIC:INPUT:DX, and TRIGGER:A:LOGIC:INPUT:RF. If you would like to use the logic trigger without a clock, you can also use the command TRIGGER:A:LOGIC:PATTERN:DELTATIME.
  • SETHold - Use with the commands TRIGGER:A:SETHOLD:CLOCK:EDGE, TRIGGER:A:SETHOLD:CLOCK:SOURCE, TRIGGER:A:SETHOLD:CLOCK:THRESHOLD, TRIGGER:A:SETHOLD:DATA:SOURCE.

TriggerALogicFunction

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOGIc:FUNCtion command.

Description
  • This command sets or queries the logical combination of the input channels for logic triggers. This command is equivalent to selecting Logic for the Trigger Type, and setting or viewing the Define Logic.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:FUNCtion? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:FUNCtion? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:FUNCtion value command.
SCPI Syntax
- TRIGger:A:LOGIc:FUNCtion {AND|NANd|NOR|OR}
- TRIGger:A:LOGIc:FUNCtion?
Info
  • AND specifies to trigger if all conditions are true.
  • NANd specifies to trigger if any of the conditions are false.
  • NOR specifies to trigger if all conditions are false.
  • OR specifies to trigger if any of the conditions are true.

TriggerALogicInput

Bases: SCPICmdRead

The TRIGger:A:LOGIc:INPut command.

Description
  • Returns the logic input values for all channels. If a clock channel is defined, it returns the clock source and edge.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:INPut? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:INPut? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:LOGIc:INPut?
Properties
  • .ch: The TRIGger:A:LOGIc:INPut:CH<x> command.
  • .clock: The TRIGger:A:LOGIc:INPut:CLOCk command tree.
  • .d: The TRIGger:A:LOGIc:INPut:D<x> command.
  • .rf: The TRIGger:A:LOGIc:INPut:RF command.

ch property

Return the TRIGger:A:LOGIc:INPut:CH<x> command.

Description
  • This command specifies the logical input condition for the channel specified by .
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:INPut:CH<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:INPut:CH<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:INPut:CH<x> value command.
SCPI Syntax
- TRIGger:A:LOGIc:INPut:CH<x> {HIGH|LOW|X}
- TRIGger:A:LOGIc:INPut:CH<x>?
Info
  • HIGH specifies the logic high.
  • LOW specifies the logic low.
  • X specifies a ‘don’t care’ state.

clock property

Return the TRIGger:A:LOGIc:INPut:CLOCk command tree.

Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:INPut:CLOCk? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:INPut:CLOCk? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .edge: The TRIGger:A:LOGIc:INPut:CLOCk:EDGE command.
  • .source: The TRIGger:A:LOGIc:INPut:CLOCk:SOUrce command.

d property

Return the TRIGger:A:LOGIc:INPut:D<x> command.

Description
  • This command specifies the logic pattern for a trigger on digital channel , where x is the channel number.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:INPut:D<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:INPut:D<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:INPut:D<x> value command.
SCPI Syntax
- TRIGger:A:LOGIc:INPut:D<x> {HIGH|LOW|X}
- TRIGger:A:LOGIc:INPut:D<x>?
Info
  • High specifies the logic high state.
  • Low specifies the logic low state.
  • X specifies a ‘don’t care’ state.

rf property

Return the TRIGger:A:LOGIc:INPut:RF command.

Description
  • This command specifies the logic level to use when the internal RF power level is the source for a logic pattern trigger.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:INPut:RF? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:INPut:RF? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:INPut:RF value command.
SCPI Syntax
- TRIGger:A:LOGIc:INPut:RF {HIGH|LOW|X}
- TRIGger:A:LOGIc:INPut:RF?
Info
  • HIGH specifies to trigger on a high logic level.
  • LOW specifies to trigger on a low logic level.
  • X specifies a ‘don’t care’ condition.

TriggerALogicInputChannel

Bases: ValidatedChannel, SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOGIc:INPut:CH<x> command.

Description
  • This command specifies the logical input condition for the channel specified by .
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:INPut:CH<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:INPut:CH<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:INPut:CH<x> value command.
SCPI Syntax
- TRIGger:A:LOGIc:INPut:CH<x> {HIGH|LOW|X}
- TRIGger:A:LOGIc:INPut:CH<x>?
Info
  • HIGH specifies the logic high.
  • LOW specifies the logic low.
  • X specifies a ‘don’t care’ state.

TriggerALogicInputClock

Bases: SCPICmdRead

The TRIGger:A:LOGIc:INPut:CLOCk command tree.

Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:INPut:CLOCk? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:INPut:CLOCk? query and raise an AssertionError if the returned value does not match value.
Properties
  • .edge: The TRIGger:A:LOGIc:INPut:CLOCk:EDGE command.
  • .source: The TRIGger:A:LOGIc:INPut:CLOCk:SOUrce command.

edge property

Return the TRIGger:A:LOGIc:INPut:CLOCk:EDGE command.

Description
  • Sets the polarity of the clock channel.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:INPut:CLOCk:EDGE? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:INPut:CLOCk:EDGE? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:INPut:CLOCk:EDGE value command.
SCPI Syntax
- TRIGger:A:LOGIc:INPut:CLOCk:EDGE {FALL|RISe}
- TRIGger:A:LOGIc:INPut:CLOCk:EDGE?
Info
  • RISe specifies to trigger on the rising or positive edge of a signal.
  • FALL specifies to trigger on the falling or negative edge of a signal.

source property

Return the TRIGger:A:LOGIc:INPut:CLOCk:SOUrce command.

Description
  • This command specifies the channel to use as the clock source. The clock can be selected as NONE. A selection of None implies pattern trigger. Any other selection implies state trigger.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:INPut:CLOCk:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:INPut:CLOCk:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:INPut:CLOCk:SOUrce value command.
SCPI Syntax
- TRIGger:A:LOGIc:INPut:CLOCk:SOUrce {CH<x>|D<x>|RF|NONE}
- TRIGger:A:LOGIc:INPut:CLOCk:SOUrce?
Info
  • CH<x> specifies an analog channel as the clock source.
  • D<x> specifies a digital channel as the clock source. (Requires option 3-MSO.).
  • NONE specifies a Pattern trigger.

TriggerALogicInputClockEdge

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOGIc:INPut:CLOCk:EDGE command.

Description
  • Sets the polarity of the clock channel.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:INPut:CLOCk:EDGE? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:INPut:CLOCk:EDGE? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:INPut:CLOCk:EDGE value command.
SCPI Syntax
- TRIGger:A:LOGIc:INPut:CLOCk:EDGE {FALL|RISe}
- TRIGger:A:LOGIc:INPut:CLOCk:EDGE?
Info
  • RISe specifies to trigger on the rising or positive edge of a signal.
  • FALL specifies to trigger on the falling or negative edge of a signal.

TriggerALogicInputClockSource

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOGIc:INPut:CLOCk:SOUrce command.

Description
  • This command specifies the channel to use as the clock source. The clock can be selected as NONE. A selection of None implies pattern trigger. Any other selection implies state trigger.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:INPut:CLOCk:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:INPut:CLOCk:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:INPut:CLOCk:SOUrce value command.
SCPI Syntax
- TRIGger:A:LOGIc:INPut:CLOCk:SOUrce {CH<x>|D<x>|RF|NONE}
- TRIGger:A:LOGIc:INPut:CLOCk:SOUrce?
Info
  • CH<x> specifies an analog channel as the clock source.
  • D<x> specifies a digital channel as the clock source. (Requires option 3-MSO.).
  • NONE specifies a Pattern trigger.

TriggerALogicInputDigitalBit

Bases: ValidatedDigitalBit, SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOGIc:INPut:D<x> command.

Description
  • This command specifies the logic pattern for a trigger on digital channel , where x is the channel number.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:INPut:D<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:INPut:D<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:INPut:D<x> value command.
SCPI Syntax
- TRIGger:A:LOGIc:INPut:D<x> {HIGH|LOW|X}
- TRIGger:A:LOGIc:INPut:D<x>?
Info
  • High specifies the logic high state.
  • Low specifies the logic low state.
  • X specifies a ‘don’t care’ state.

TriggerALogicInputRf

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOGIc:INPut:RF command.

Description
  • This command specifies the logic level to use when the internal RF power level is the source for a logic pattern trigger.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:INPut:RF? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:INPut:RF? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:INPut:RF value command.
SCPI Syntax
- TRIGger:A:LOGIc:INPut:RF {HIGH|LOW|X}
- TRIGger:A:LOGIc:INPut:RF?
Info
  • HIGH specifies to trigger on a high logic level.
  • LOW specifies to trigger on a low logic level.
  • X specifies a ‘don’t care’ condition.

TriggerALogicPattern

Bases: SCPICmdRead

The TRIGger:A:LOGIc:PATtern command.

Description
  • Returns the conditions used for generating an A logic pattern trigger, with respect to the defined input pattern, and identifies the time that the selected pattern may be true and still generate the trigger.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:PATtern? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:PATtern? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:LOGIc:PATtern?
Properties
  • .deltatime: The TRIGger:A:LOGIc:PATtern:DELTatime command.
  • .when: The TRIGger:A:LOGIc:PATtern:WHEn command.

deltatime property

Return the TRIGger:A:LOGIc:PATtern:DELTatime command.

Description
  • This command specifies the pattern trigger delta time value. The time value is used as part of the pattern trigger condition to determine if the duration of a logic pattern meets the specified time constraints.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:PATtern:DELTatime? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:PATtern:DELTatime? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:PATtern:DELTatime value command.
SCPI Syntax
- TRIGger:A:LOGIc:PATtern:DELTatime <NR3>
- TRIGger:A:LOGIc:PATtern:DELTatime?
Info
  • <NR3> is a floating point value with exponent that sets the pattern trigger time value. This argument has a range of 39.6E-9 (39.6 ns) to 10.0E0 (10 s), in increments of 13.2 ns. Values that are not an increment of 13.2 ns are rounded to the nearest correct value.

when property

Return the TRIGger:A:LOGIc:PATtern:WHEn command.

Description
  • This command specifies the pattern logic condition on which to trigger the oscilloscope.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:PATtern:WHEn? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:PATtern:WHEn? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:PATtern:WHEn value command.
SCPI Syntax
- TRIGger:A:LOGIc:PATtern:WHEn {TRUe|FALSe|LESSthan|MOREthan|EQual|UNEQual}
- TRIGger:A:LOGIc:PATtern:WHEn?
Info
  • TRUE triggers the oscilloscope when the pattern becomes true.
  • FALSE triggers the oscilloscope when the pattern becomes false.
  • LESSTHAN triggers the oscilloscope when the input pattern is true for a time period less than the time period specified in TRIGGER:A:LOGIC:PATTERN:DELTATIME.
  • MORETHAN triggers the oscilloscope when the input pattern is true for a time period more (greater) than the time period specified in TRIGGER:A:LOGIC:PATTERN:DELTATIME.
  • EQUAL triggers the oscilloscope when the input pattern is true for a time period equal to the time period specified in TRIGGER:A:LOGIC:PATTERN:DELTATIME, within a ±5% tolerance.
  • UNEQUAL triggers the oscilloscope when the input pattern is true for a time period greater than or less than (not equal to) the time period specified in TRIGGER:A:LOGIC:PATTERN:DELTATIME, within a ±5% tolerance.

TriggerALogicPatternDeltatime

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOGIc:PATtern:DELTatime command.

Description
  • This command specifies the pattern trigger delta time value. The time value is used as part of the pattern trigger condition to determine if the duration of a logic pattern meets the specified time constraints.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:PATtern:DELTatime? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:PATtern:DELTatime? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:PATtern:DELTatime value command.
SCPI Syntax
- TRIGger:A:LOGIc:PATtern:DELTatime <NR3>
- TRIGger:A:LOGIc:PATtern:DELTatime?
Info
  • <NR3> is a floating point value with exponent that sets the pattern trigger time value. This argument has a range of 39.6E-9 (39.6 ns) to 10.0E0 (10 s), in increments of 13.2 ns. Values that are not an increment of 13.2 ns are rounded to the nearest correct value.

TriggerALogicPatternWhen

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOGIc:PATtern:WHEn command.

Description
  • This command specifies the pattern logic condition on which to trigger the oscilloscope.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:PATtern:WHEn? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:PATtern:WHEn? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:PATtern:WHEn value command.
SCPI Syntax
- TRIGger:A:LOGIc:PATtern:WHEn {TRUe|FALSe|LESSthan|MOREthan|EQual|UNEQual}
- TRIGger:A:LOGIc:PATtern:WHEn?
Info
  • TRUE triggers the oscilloscope when the pattern becomes true.
  • FALSE triggers the oscilloscope when the pattern becomes false.
  • LESSTHAN triggers the oscilloscope when the input pattern is true for a time period less than the time period specified in TRIGGER:A:LOGIC:PATTERN:DELTATIME.
  • MORETHAN triggers the oscilloscope when the input pattern is true for a time period more (greater) than the time period specified in TRIGGER:A:LOGIC:PATTERN:DELTATIME.
  • EQUAL triggers the oscilloscope when the input pattern is true for a time period equal to the time period specified in TRIGGER:A:LOGIC:PATTERN:DELTATIME, within a ±5% tolerance.
  • UNEQUAL triggers the oscilloscope when the input pattern is true for a time period greater than or less than (not equal to) the time period specified in TRIGGER:A:LOGIC:PATTERN:DELTATIME, within a ±5% tolerance.

TriggerALogicThreshold

Bases: SCPICmdRead

The TRIGger:A:LOGIc:THReshold command tree.

Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:THReshold? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:THReshold? query and raise an AssertionError if the returned value does not match value.
Properties
  • .ch: The TRIGger:A:LOGIc:THReshold:CH<x> command.
  • .d: The TRIGger:A:LOGIc:THReshold:D<x> command.
  • .rf: The TRIGger:A:LOGIc:THReshold:RF command.

ch property

Return the TRIGger:A:LOGIc:THReshold:CH<x> command.

Description
  • This command sets or queries the trigger A logic threshold voltage for the specified channel x.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:THReshold:CH<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:THReshold:CH<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:THReshold:CH<x> value command.
SCPI Syntax
- TRIGger:A:LOGIc:THReshold:CH<x> {<NR3>|ECL|TTL}
- TRIGger:A:LOGIc:THReshold:CH<x>?
Info
  • <NR3> is a floating point number that specifies the threshold voltage, in volts.
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.

d property

Return the TRIGger:A:LOGIc:THReshold:D<x> command.

Description
  • This command specifies the trigger A logic threshold level for the specified digital channel . This commands affects all trigger types using the digital channel.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:THReshold:D<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:THReshold:D<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:THReshold:D<x> value command.
SCPI Syntax
- TRIGger:A:LOGIc:THReshold:D<x> {<NR3>|ECL|TTL}
- TRIGger:A:LOGIc:THReshold:D<x>?
Info
  • <NR3> is a floating point number that specifies the threshold level in volts.
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.

rf property

Return the TRIGger:A:LOGIc:THReshold:RF command.

Description
  • This command specifies the threshold to use when the internal RF power level is the source for a logic trigger. It will affect all trigger types using the channel.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:THReshold:RF? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:THReshold:RF? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:THReshold:RF value command.
SCPI Syntax
- TRIGger:A:LOGIc:THReshold:RF {<NR3>}
- TRIGger:A:LOGIc:THReshold:RF?
Info
  • <NR3> is a floating point number that specifies the threshold to use, in the currently selected RF units (using RF:UNITS). The range is (ref level - 40 dBm) to (ref level + 10 dBm), but never less than -65 dBm or more than +30 dBm.

TriggerALogicThresholdChannel

Bases: ValidatedChannel, SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOGIc:THReshold:CH<x> command.

Description
  • This command sets or queries the trigger A logic threshold voltage for the specified channel x.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:THReshold:CH<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:THReshold:CH<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:THReshold:CH<x> value command.
SCPI Syntax
- TRIGger:A:LOGIc:THReshold:CH<x> {<NR3>|ECL|TTL}
- TRIGger:A:LOGIc:THReshold:CH<x>?
Info
  • <NR3> is a floating point number that specifies the threshold voltage, in volts.
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.

TriggerALogicThresholdDigitalBit

Bases: ValidatedDigitalBit, SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOGIc:THReshold:D<x> command.

Description
  • This command specifies the trigger A logic threshold level for the specified digital channel . This commands affects all trigger types using the digital channel.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:THReshold:D<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:THReshold:D<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:THReshold:D<x> value command.
SCPI Syntax
- TRIGger:A:LOGIc:THReshold:D<x> {<NR3>|ECL|TTL}
- TRIGger:A:LOGIc:THReshold:D<x>?
Info
  • <NR3> is a floating point number that specifies the threshold level in volts.
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.

TriggerALogicThresholdRf

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOGIc:THReshold:RF command.

Description
  • This command specifies the threshold to use when the internal RF power level is the source for a logic trigger. It will affect all trigger types using the channel.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:THReshold:RF? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:THReshold:RF? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:THReshold:RF value command.
SCPI Syntax
- TRIGger:A:LOGIc:THReshold:RF {<NR3>}
- TRIGger:A:LOGIc:THReshold:RF?
Info
  • <NR3> is a floating point number that specifies the threshold to use, in the currently selected RF units (using RF:UNITS). The range is (ref level - 40 dBm) to (ref level + 10 dBm), but never less than -65 dBm or more than +30 dBm.

TriggerALowerthreshold

Bases: SCPICmdRead

The TRIGger:A:LOWerthreshold command tree.

Usage
  • Using the .query() method will send the TRIGger:A:LOWerthreshold? query.
  • Using the .verify(value) method will send the TRIGger:A:LOWerthreshold? query and raise an AssertionError if the returned value does not match value.
Properties
  • .ch: The TRIGger:A:LOWerthreshold:CH<x> command.
  • .d: The TRIGger:A:LOWerthreshold:D<x> command.
  • .rf: The TRIGger:A:LOWerthreshold:RF command.
  • .aux: The TRIGger:A:LOWerthreshold:AUX command.
  • .ext: The TRIGger:A:LOWerthreshold:EXT command.

aux property

Return the TRIGger:A:LOWerthreshold:AUX command.

Description
  • This command specifies the lower threshold for the Aux Input connector. Used for the following trigger types: runt, transition.
Usage
  • Using the .query() method will send the TRIGger:A:LOWerthreshold:AUX? query.
  • Using the .verify(value) method will send the TRIGger:A:LOWerthreshold:AUX? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOWerthreshold:AUX value command.
SCPI Syntax
- TRIGger:A:LOWerthreshold:AUX {<NR3>|ECL|TTL}
- TRIGger:A:LOWerthreshold:AUX?
Info
  • <NR3> is a floating point number that specifies the threshold level in volts.
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.

ch property

Return the TRIGger:A:LOWerthreshold:CH<x> command.

Description
  • This command specifies the lower threshold for the channel selected. Each channel can have an independent level. Used in runt and transition triggers as the lower threshold. Used for all other trigger types as the single level/threshold.
Usage
  • Using the .query() method will send the TRIGger:A:LOWerthreshold:CH<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LOWerthreshold:CH<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOWerthreshold:CH<x> value command.
SCPI Syntax
- TRIGger:A:LOWerthreshold:CH<x> {ECL|TTL|<NR3>}
- TRIGger:A:LOWerthreshold:CH<x>?
Info
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.
  • <NR3> is a floating point number that specifies the clock level, in volts.

d property

Return the TRIGger:A:LOWerthreshold:D<x> command.

Description
  • Sets the lower threshold for the digital channel selected. Each channel can have an independent level. Used in runt and transition as the lower threshold. Used for all other trigger types as the single level/threshold.
Usage
  • Using the .query() method will send the TRIGger:A:LOWerthreshold:D<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LOWerthreshold:D<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOWerthreshold:D<x> value command.
SCPI Syntax
- TRIGger:A:LOWerthreshold:D<x> {<NR3>|ECL|TTL}
- TRIGger:A:LOWerthreshold:D<x>?
Info
  • <NR3> is a floating point number that specifies the threshold voltage, in volts.
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.

ext property

Return the TRIGger:A:LOWerthreshold:EXT command.

Description
  • This command specifies the lower threshold for the Aux Input connector. Used for the following trigger types: runt, transition.
Usage
  • Using the .query() method will send the TRIGger:A:LOWerthreshold:EXT? query.
  • Using the .verify(value) method will send the TRIGger:A:LOWerthreshold:EXT? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOWerthreshold:EXT value command.
SCPI Syntax
- TRIGger:A:LOWerthreshold:EXT {<NR3>|ECL|TTL}
- TRIGger:A:LOWerthreshold:EXT?
Info
  • <NR3> is a floating point number that specifies the threshold level in volts.
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.

rf property

Return the TRIGger:A:LOWerthreshold:RF command.

Description
  • This command specifies the lower threshold when using the internal RF power level for a RUNT trigger, or the single threshold in the cases of the PULSE and TIMEOUT triggers. To specify the upper threshold for the internal RF power level for the RUNT trigger type, use the command TRIGGER:A:UPPERTHRESHOLD:RF. To choose the RUNT trigger type, use the command TRIGGER:A:PULSE:CLASS.
Usage
  • Using the .query() method will send the TRIGger:A:LOWerthreshold:RF? query.
  • Using the .verify(value) method will send the TRIGger:A:LOWerthreshold:RF? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOWerthreshold:RF value command.
SCPI Syntax
- TRIGger:A:LOWerthreshold:RF {<NR3>}
- TRIGger:A:LOWerthreshold:RF?
Info
  • <NR3> is a floating point number that specifies the threshold to use, in the currently selected RF units (using RF:UNITS). The range is (ref level - 40 dBm) to (ref level + 10 dBm), but never less than -65 dBm or more than +30 dBm.

TriggerALowerthresholdAux

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOWerthreshold:AUX command.

Description
  • This command specifies the lower threshold for the Aux Input connector. Used for the following trigger types: runt, transition.
Usage
  • Using the .query() method will send the TRIGger:A:LOWerthreshold:AUX? query.
  • Using the .verify(value) method will send the TRIGger:A:LOWerthreshold:AUX? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOWerthreshold:AUX value command.
SCPI Syntax
- TRIGger:A:LOWerthreshold:AUX {<NR3>|ECL|TTL}
- TRIGger:A:LOWerthreshold:AUX?
Info
  • <NR3> is a floating point number that specifies the threshold level in volts.
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.

TriggerALowerthresholdChannel

Bases: ValidatedChannel, SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOWerthreshold:CH<x> command.

Description
  • This command specifies the lower threshold for the channel selected. Each channel can have an independent level. Used in runt and transition triggers as the lower threshold. Used for all other trigger types as the single level/threshold.
Usage
  • Using the .query() method will send the TRIGger:A:LOWerthreshold:CH<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LOWerthreshold:CH<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOWerthreshold:CH<x> value command.
SCPI Syntax
- TRIGger:A:LOWerthreshold:CH<x> {ECL|TTL|<NR3>}
- TRIGger:A:LOWerthreshold:CH<x>?
Info
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.
  • <NR3> is a floating point number that specifies the clock level, in volts.

TriggerALowerthresholdDigitalBit

Bases: ValidatedDigitalBit, SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOWerthreshold:D<x> command.

Description
  • Sets the lower threshold for the digital channel selected. Each channel can have an independent level. Used in runt and transition as the lower threshold. Used for all other trigger types as the single level/threshold.
Usage
  • Using the .query() method will send the TRIGger:A:LOWerthreshold:D<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LOWerthreshold:D<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOWerthreshold:D<x> value command.
SCPI Syntax
- TRIGger:A:LOWerthreshold:D<x> {<NR3>|ECL|TTL}
- TRIGger:A:LOWerthreshold:D<x>?
Info
  • <NR3> is a floating point number that specifies the threshold voltage, in volts.
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.

TriggerALowerthresholdExt

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOWerthreshold:EXT command.

Description
  • This command specifies the lower threshold for the Aux Input connector. Used for the following trigger types: runt, transition.
Usage
  • Using the .query() method will send the TRIGger:A:LOWerthreshold:EXT? query.
  • Using the .verify(value) method will send the TRIGger:A:LOWerthreshold:EXT? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOWerthreshold:EXT value command.
SCPI Syntax
- TRIGger:A:LOWerthreshold:EXT {<NR3>|ECL|TTL}
- TRIGger:A:LOWerthreshold:EXT?
Info
  • <NR3> is a floating point number that specifies the threshold level in volts.
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.

TriggerALowerthresholdRf

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOWerthreshold:RF command.

Description
  • This command specifies the lower threshold when using the internal RF power level for a RUNT trigger, or the single threshold in the cases of the PULSE and TIMEOUT triggers. To specify the upper threshold for the internal RF power level for the RUNT trigger type, use the command TRIGGER:A:UPPERTHRESHOLD:RF. To choose the RUNT trigger type, use the command TRIGGER:A:PULSE:CLASS.
Usage
  • Using the .query() method will send the TRIGger:A:LOWerthreshold:RF? query.
  • Using the .verify(value) method will send the TRIGger:A:LOWerthreshold:RF? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOWerthreshold:RF value command.
SCPI Syntax
- TRIGger:A:LOWerthreshold:RF {<NR3>}
- TRIGger:A:LOWerthreshold:RF?
Info
  • <NR3> is a floating point number that specifies the threshold to use, in the currently selected RF units (using RF:UNITS). The range is (ref level - 40 dBm) to (ref level + 10 dBm), but never less than -65 dBm or more than +30 dBm.

TriggerAMode

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:MODe command.

Description
  • This command sets or queries the A trigger mode. This command is equivalent to pushing the Mode button on the front panel.
Usage
  • Using the .query() method will send the TRIGger:A:MODe? query.
  • Using the .verify(value) method will send the TRIGger:A:MODe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:MODe value command.
SCPI Syntax
- TRIGger:A:MODe {AUTO|NORMal}
- TRIGger:A:MODe?
Info
  • AUTO generates a trigger if one is not detected within a specified time period.
  • NORMal waits for a valid trigger event.

TriggerAPulse

Bases: SCPICmdRead

The TRIGger:A:PULse command tree.

Usage
  • Using the .query() method will send the TRIGger:A:PULse? query.
  • Using the .verify(value) method will send the TRIGger:A:PULse? query and raise an AssertionError if the returned value does not match value.
Properties
  • .class: The TRIGger:A:PULse:CLAss command.

class_ property

Return the TRIGger:A:PULse:CLAss command.

Description
  • This command specifies which kind of pulse to trigger on (either runt, width, transition (rise/fall or slew rate) or timeout). You also need to set the trigger type to PULSe using the command TRIGGER:A:TYPE. To set the trigger source for a pulse trigger, use TRIGGER:A:RUNT:SOURCE, TRIGGER:A:PULSEWIDTH:SOURCE, , or TRIGGER:A:TIMEOUT:SOURCE. To set the trigger voltage threshold level for a pulse trigger, use TRIGGER:A:LEVEL:AUXIN, TRIGGER:A:LEVEL:CHX, or TRIGGER:A:LEVEL:DX.
Usage
  • Using the .query() method will send the TRIGger:A:PULse:CLAss? query.
  • Using the .verify(value) method will send the TRIGger:A:PULse:CLAss? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:PULse:CLAss value command.
SCPI Syntax
- TRIGger:A:PULse:CLAss {RUNt|WIDth|TRANsition|TIMEOut}
- TRIGger:A:PULse:CLAss?
Info
  • RUNt triggers when a pulse crosses the first preset voltage threshold but does not cross the second preset threshold before recrossing the first. Use with the command TRIGGER:A:RUNT:SOURCE, TRIGGER:A:RUNT:POLARITY, TRIGGER:A:RUNT:WHEN, and TRIGGER:A:RUNT:WIDTH.
  • WIDth triggers when a pulse is found that has the specified width or duration and is either inside or outside the specified time limits. Use with the commands TRIGGER:A:PULSEWIDTH:HIGHLIMIT, TRIGGER:A:PULSEWIDTH:LOWLIMIT, TRIGGER:A:PULSEWIDTH:POLARITY, TRIGGER:A:PULSEWIDTH:SOURCE, TRIGGER:A:PULSEWIDTH:WHEN, and TRIGGER:A:PULSEWIDTH:WIDTH.
  • TRANsition (AKA rise/fall or slew rate) triggers when a pulse crosses both thresholds in the same direction as the specified polarity and the transition time between the two threshold crossings is greater or less than the specified time delta. Use with the commands.
  • TIMEout triggers when no pulse is detected within a specified time. The signal stays above, below, or either above or below, a set value for a set amount of time. Use with the commands TRIGGER:A:TIMEOUT:TIME, TRIGGER:A:TIMEOUT:POLARITY, TRIGGER:A:TIMEOUT:SOURCE.

TriggerAPulseClass

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:PULse:CLAss command.

Description
  • This command specifies which kind of pulse to trigger on (either runt, width, transition (rise/fall or slew rate) or timeout). You also need to set the trigger type to PULSe using the command TRIGGER:A:TYPE. To set the trigger source for a pulse trigger, use TRIGGER:A:RUNT:SOURCE, TRIGGER:A:PULSEWIDTH:SOURCE, , or TRIGGER:A:TIMEOUT:SOURCE. To set the trigger voltage threshold level for a pulse trigger, use TRIGGER:A:LEVEL:AUXIN, TRIGGER:A:LEVEL:CHX, or TRIGGER:A:LEVEL:DX.
Usage
  • Using the .query() method will send the TRIGger:A:PULse:CLAss? query.
  • Using the .verify(value) method will send the TRIGger:A:PULse:CLAss? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:PULse:CLAss value command.
SCPI Syntax
- TRIGger:A:PULse:CLAss {RUNt|WIDth|TRANsition|TIMEOut}
- TRIGger:A:PULse:CLAss?
Info
  • RUNt triggers when a pulse crosses the first preset voltage threshold but does not cross the second preset threshold before recrossing the first. Use with the command TRIGGER:A:RUNT:SOURCE, TRIGGER:A:RUNT:POLARITY, TRIGGER:A:RUNT:WHEN, and TRIGGER:A:RUNT:WIDTH.
  • WIDth triggers when a pulse is found that has the specified width or duration and is either inside or outside the specified time limits. Use with the commands TRIGGER:A:PULSEWIDTH:HIGHLIMIT, TRIGGER:A:PULSEWIDTH:LOWLIMIT, TRIGGER:A:PULSEWIDTH:POLARITY, TRIGGER:A:PULSEWIDTH:SOURCE, TRIGGER:A:PULSEWIDTH:WHEN, and TRIGGER:A:PULSEWIDTH:WIDTH.
  • TRANsition (AKA rise/fall or slew rate) triggers when a pulse crosses both thresholds in the same direction as the specified polarity and the transition time between the two threshold crossings is greater or less than the specified time delta. Use with the commands.
  • TIMEout triggers when no pulse is detected within a specified time. The signal stays above, below, or either above or below, a set value for a set amount of time. Use with the commands TRIGGER:A:TIMEOUT:TIME, TRIGGER:A:TIMEOUT:POLARITY, TRIGGER:A:TIMEOUT:SOURCE.

TriggerAPulsewidth

Bases: SCPICmdRead

The TRIGger:A:PULSEWidth command tree.

Usage
  • Using the .query() method will send the TRIGger:A:PULSEWidth? query.
  • Using the .verify(value) method will send the TRIGger:A:PULSEWidth? query and raise an AssertionError if the returned value does not match value.
Properties
  • .highlimit: The TRIGger:A:PULSEWidth:HIGHLimit command.
  • .lowlimit: The TRIGger:A:PULSEWidth:LOWLimit command.
  • .polarity: The TRIGger:A:PULSEWidth:POLarity command.
  • .source: The TRIGger:A:PULSEWidth:SOUrce command.
  • .when: The TRIGger:A:PULSEWidth:WHEn command.
  • .width: The TRIGger:A:PULSEWidth:WIDth command.

highlimit property

Return the TRIGger:A:PULSEWidth:HIGHLimit command.

Description
  • This command specifies the upper limit to use, in seconds, when triggering on detection of a pulse whose duration is inside or outside a range of two values. (Use TRIGGER:A:PULSEWIDTH:LOWLIMIT to specify the lower value of the range.)
Usage
  • Using the .query() method will send the TRIGger:A:PULSEWidth:HIGHLimit? query.
  • Using the .verify(value) method will send the TRIGger:A:PULSEWidth:HIGHLimit? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:PULSEWidth:HIGHLimit value command.
SCPI Syntax
- TRIGger:A:PULSEWidth:HIGHLimit <NR3>
- TRIGger:A:PULSEWidth:HIGHLimit?
Info
  • <NR3> is a floating point number that represents the higher value of the range.

lowlimit property

Return the TRIGger:A:PULSEWidth:LOWLimit command.

Description
  • This command specifies the lower limit to use, in seconds, when triggering on detection of a pulse whose duration is inside or outside a range of two values. (Use TRIGGER:A:PULSEWIDTH:HIGHLIMIT to specify the upper limit of the range.) This command also specifies the single limit to use, in seconds, when triggering on detection of a pulse whose duration is less than, greater than, equal to, or not equal to this time limit.
Usage
  • Using the .query() method will send the TRIGger:A:PULSEWidth:LOWLimit? query.
  • Using the .verify(value) method will send the TRIGger:A:PULSEWidth:LOWLimit? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:PULSEWidth:LOWLimit value command.
SCPI Syntax
- TRIGger:A:PULSEWidth:LOWLimit <NR3>
- TRIGger:A:PULSEWidth:LOWLimit?
Info
  • <NR3> is a floating point number that represents the lower value of the range.

polarity property

Return the TRIGger:A:PULSEWidth:POLarity command.

Description
  • This command specifies the polarity for a pulse width trigger.
Usage
  • Using the .query() method will send the TRIGger:A:PULSEWidth:POLarity? query.
  • Using the .verify(value) method will send the TRIGger:A:PULSEWidth:POLarity? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:PULSEWidth:POLarity value command.
SCPI Syntax
- TRIGger:A:PULSEWidth:POLarity {NEGative|POSitive}
- TRIGger:A:PULSEWidth:POLarity?
Info
  • NEGative specifies a negative pulse.
  • POSitive specifies a positive pulse.

source property

Return the TRIGger:A:PULSEWidth:SOUrce command.

Description
  • This command specifies the source waveform for a pulse width trigger.
Usage
  • Using the .query() method will send the TRIGger:A:PULSEWidth:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:PULSEWidth:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:PULSEWidth:SOUrce value command.
SCPI Syntax
- TRIGger:A:PULSEWidth:SOUrce {CH<x>|LINE|AUX|D<x>|RF}
- TRIGger:A:PULSEWidth:SOUrce?
Info
  • CH<x> specifies an analog input channel as the pulse-width trigger source.
  • AUX specifies an external trigger using the Aux In connector located on the front panel of the oscilloscope. (Only for 2-channel model MDO32.).
  • LINE specifies AC line voltage as the trigger source.
  • D<x> specifies a digital channel as the trigger source.

when property

Return the TRIGger:A:PULSEWidth:WHEn command.

Description
  • This command specifies to trigger when a pulse is detected with a width (duration) that is less than, greater than, equal to, or unequal to a specified value (set using TRIGGER:A:PULSEWIDTH:LOWLIMIT), OR whose width falls outside of or within a specified range of two values (set using TRIGGER:A:PULSEWIDTH:LOWLIMIT and TRIGGER:A:PULSEWIDTH:HIGHLIMIT).
Usage
  • Using the .query() method will send the TRIGger:A:PULSEWidth:WHEn? query.
  • Using the .verify(value) method will send the TRIGger:A:PULSEWidth:WHEn? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:PULSEWidth:WHEn value command.
SCPI Syntax
- TRIGger:A:PULSEWidth:WHEn {LESSthan|MOREthan|EQual|UNEQual|WIThin|OUTside}
- TRIGger:A:PULSEWidth:WHEn?
Info
  • LESSthan causes a trigger when a pulse is detected with a width less than the time set by the TRIGGER:A:PULSEWIDTH:LOWLIMIT command.
  • MOREthan causes a trigger when a pulse is detected with a width greater than the time set by the TRIGGER:A:PULSEWIDTH:LOWLIMIT command.
  • EQual causes a trigger when a pulse is detected with a width equal to the time period specified in TRIGGER:A:PULSEWIDTH:LOWLIMIT within a ±5% tolerance.
  • UNEQual causes a trigger when a pulse is detected with a width greater than or less than (but not equal) the time period specified in TRIGGER:A:PULSEWIDTH:LOWLIMIT within a ±5% tolerance.
  • WIThin causes a trigger when a pulse is detected that is within a range set by two values.
  • OUTside causes a trigger when a pulse is detected that is outside of a range set by two values.

width property

Return the TRIGger:A:PULSEWidth:WIDth command.

Description
  • This command specifies the pulse width (duration), in seconds, for triggering on pulses whose widths are greater than, less than, equal to, or not equal to the specified value.
Usage
  • Using the .query() method will send the TRIGger:A:PULSEWidth:WIDth? query.
  • Using the .verify(value) method will send the TRIGger:A:PULSEWidth:WIDth? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:PULSEWidth:WIDth value command.
SCPI Syntax
- TRIGger:A:PULSEWidth:WIDth <NR3>
- TRIGger:A:PULSEWidth:WIDth?
Info
  • <NR3> is a floating point number that specifies the pulse width in seconds.

TriggerAPulsewidthHighlimit

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:PULSEWidth:HIGHLimit command.

Description
  • This command specifies the upper limit to use, in seconds, when triggering on detection of a pulse whose duration is inside or outside a range of two values. (Use TRIGGER:A:PULSEWIDTH:LOWLIMIT to specify the lower value of the range.)
Usage
  • Using the .query() method will send the TRIGger:A:PULSEWidth:HIGHLimit? query.
  • Using the .verify(value) method will send the TRIGger:A:PULSEWidth:HIGHLimit? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:PULSEWidth:HIGHLimit value command.
SCPI Syntax
- TRIGger:A:PULSEWidth:HIGHLimit <NR3>
- TRIGger:A:PULSEWidth:HIGHLimit?
Info
  • <NR3> is a floating point number that represents the higher value of the range.

TriggerAPulsewidthLowlimit

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:PULSEWidth:LOWLimit command.

Description
  • This command specifies the lower limit to use, in seconds, when triggering on detection of a pulse whose duration is inside or outside a range of two values. (Use TRIGGER:A:PULSEWIDTH:HIGHLIMIT to specify the upper limit of the range.) This command also specifies the single limit to use, in seconds, when triggering on detection of a pulse whose duration is less than, greater than, equal to, or not equal to this time limit.
Usage
  • Using the .query() method will send the TRIGger:A:PULSEWidth:LOWLimit? query.
  • Using the .verify(value) method will send the TRIGger:A:PULSEWidth:LOWLimit? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:PULSEWidth:LOWLimit value command.
SCPI Syntax
- TRIGger:A:PULSEWidth:LOWLimit <NR3>
- TRIGger:A:PULSEWidth:LOWLimit?
Info
  • <NR3> is a floating point number that represents the lower value of the range.

TriggerAPulsewidthPolarity

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:PULSEWidth:POLarity command.

Description
  • This command specifies the polarity for a pulse width trigger.
Usage
  • Using the .query() method will send the TRIGger:A:PULSEWidth:POLarity? query.
  • Using the .verify(value) method will send the TRIGger:A:PULSEWidth:POLarity? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:PULSEWidth:POLarity value command.
SCPI Syntax
- TRIGger:A:PULSEWidth:POLarity {NEGative|POSitive}
- TRIGger:A:PULSEWidth:POLarity?
Info
  • NEGative specifies a negative pulse.
  • POSitive specifies a positive pulse.

TriggerAPulsewidthSource

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:PULSEWidth:SOUrce command.

Description
  • This command specifies the source waveform for a pulse width trigger.
Usage
  • Using the .query() method will send the TRIGger:A:PULSEWidth:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:PULSEWidth:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:PULSEWidth:SOUrce value command.
SCPI Syntax
- TRIGger:A:PULSEWidth:SOUrce {CH<x>|LINE|AUX|D<x>|RF}
- TRIGger:A:PULSEWidth:SOUrce?
Info
  • CH<x> specifies an analog input channel as the pulse-width trigger source.
  • AUX specifies an external trigger using the Aux In connector located on the front panel of the oscilloscope. (Only for 2-channel model MDO32.).
  • LINE specifies AC line voltage as the trigger source.
  • D<x> specifies a digital channel as the trigger source.

TriggerAPulsewidthWhen

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:PULSEWidth:WHEn command.

Description
  • This command specifies to trigger when a pulse is detected with a width (duration) that is less than, greater than, equal to, or unequal to a specified value (set using TRIGGER:A:PULSEWIDTH:LOWLIMIT), OR whose width falls outside of or within a specified range of two values (set using TRIGGER:A:PULSEWIDTH:LOWLIMIT and TRIGGER:A:PULSEWIDTH:HIGHLIMIT).
Usage
  • Using the .query() method will send the TRIGger:A:PULSEWidth:WHEn? query.
  • Using the .verify(value) method will send the TRIGger:A:PULSEWidth:WHEn? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:PULSEWidth:WHEn value command.
SCPI Syntax
- TRIGger:A:PULSEWidth:WHEn {LESSthan|MOREthan|EQual|UNEQual|WIThin|OUTside}
- TRIGger:A:PULSEWidth:WHEn?
Info
  • LESSthan causes a trigger when a pulse is detected with a width less than the time set by the TRIGGER:A:PULSEWIDTH:LOWLIMIT command.
  • MOREthan causes a trigger when a pulse is detected with a width greater than the time set by the TRIGGER:A:PULSEWIDTH:LOWLIMIT command.
  • EQual causes a trigger when a pulse is detected with a width equal to the time period specified in TRIGGER:A:PULSEWIDTH:LOWLIMIT within a ±5% tolerance.
  • UNEQual causes a trigger when a pulse is detected with a width greater than or less than (but not equal) the time period specified in TRIGGER:A:PULSEWIDTH:LOWLIMIT within a ±5% tolerance.
  • WIThin causes a trigger when a pulse is detected that is within a range set by two values.
  • OUTside causes a trigger when a pulse is detected that is outside of a range set by two values.

TriggerAPulsewidthWidth

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:PULSEWidth:WIDth command.

Description
  • This command specifies the pulse width (duration), in seconds, for triggering on pulses whose widths are greater than, less than, equal to, or not equal to the specified value.
Usage
  • Using the .query() method will send the TRIGger:A:PULSEWidth:WIDth? query.
  • Using the .verify(value) method will send the TRIGger:A:PULSEWidth:WIDth? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:PULSEWidth:WIDth value command.
SCPI Syntax
- TRIGger:A:PULSEWidth:WIDth <NR3>
- TRIGger:A:PULSEWidth:WIDth?
Info
  • <NR3> is a floating point number that specifies the pulse width in seconds.

TriggerARisefall

Bases: SCPICmdRead

The TRIGger:A:RISEFall command.

Description
  • Returns transition time trigger parameters.
Usage
  • Using the .query() method will send the TRIGger:A:RISEFall? query.
  • Using the .verify(value) method will send the TRIGger:A:RISEFall? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:RISEFall?
Properties
  • .deltatime: The TRIGger:A:RISEFall:DELTatime command.
  • .polarity: The TRIGger:A:RISEFall:POLarity command.
  • .source: The TRIGger:A:RISEFall:SOUrce command.
  • .when: The TRIGger:A:RISEFall:WHEn command.

deltatime property

Return the TRIGger:A:RISEFall:DELTatime command.

Description
  • This command specifies the delta time used in calculating the transition value for the transition trigger.
Usage
  • Using the .query() method will send the TRIGger:A:RISEFall:DELTatime? query.
  • Using the .verify(value) method will send the TRIGger:A:RISEFall:DELTatime? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RISEFall:DELTatime value command.
SCPI Syntax
- TRIGger:A:RISEFall:DELTatime <NR3>
- TRIGger:A:RISEFall:DELTatime?
Info
  • <NR3> is a floating point number that specifies the delta time, in seconds.

polarity property

Return the TRIGger:A:RISEFall:POLarity command.

Description
  • This command specifies the polarity for the transition trigger.
Usage
  • Using the .query() method will send the TRIGger:A:RISEFall:POLarity? query.
  • Using the .verify(value) method will send the TRIGger:A:RISEFall:POLarity? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RISEFall:POLarity value command.
SCPI Syntax
- TRIGger:A:RISEFall:POLarity {EITher|NEGative|POSitive}
- TRIGger:A:RISEFall:POLarity?
Info
  • POSitive indicates that a pulse edge must traverse from the lower (most negative) to higher (most positive) level for transition triggering to occur.
  • NEGative indicates that a pulse edge must traverse from the upper (most positive) to lower (most negative) level for transition triggering to occur.
  • EITher indicates either positive or negative polarity.

source property

Return the TRIGger:A:RISEFall:SOUrce command.

Description
  • This command specifies the source for a transition trigger.
Usage
  • Using the .query() method will send the TRIGger:A:RISEFall:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:RISEFall:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RISEFall:SOUrce value command.
SCPI Syntax
- TRIGger:A:RISEFall:SOUrce {CH<x>}
- TRIGger:A:RISEFall:SOUrce?
Info
  • CH<x> specifies one of the analog channels to be used as the source for a transition trigger.

when property

Return the TRIGger:A:RISEFall:WHEn command.

Description
  • This command specifies whether to check for a transitioning signal that is faster or slower than the specified delta time.
Usage
  • Using the .query() method will send the TRIGger:A:RISEFall:WHEn? query.
  • Using the .verify(value) method will send the TRIGger:A:RISEFall:WHEn? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RISEFall:WHEn value command.
SCPI Syntax
- TRIGger:A:RISEFall:WHEn {SLOWer|FASTer|EQual|UNEQual}
- TRIGger:A:RISEFall:WHEn?
Info
  • FASTer sets the trigger to occur when the signal transition time is faster than the time set by TRIGger:A:TRANsition:DELTatime.
  • SLOWer sets the trigger to occur when the signal transition time is slower than the time set by.TRIGger:A:TRANsition:DELTatime.
  • EQual sets the trigger to occur when the signal transition time is equal to the time set by TRIGger:A:TRANsition:DELTatime.
  • UNEQual sets the trigger to occur when the signal transition time is not equal to the time set by TRIGger:A:TRANsition:DELTatime.

TriggerARisefallDeltatime

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:RISEFall:DELTatime command.

Description
  • This command specifies the delta time used in calculating the transition value for the transition trigger.
Usage
  • Using the .query() method will send the TRIGger:A:RISEFall:DELTatime? query.
  • Using the .verify(value) method will send the TRIGger:A:RISEFall:DELTatime? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RISEFall:DELTatime value command.
SCPI Syntax
- TRIGger:A:RISEFall:DELTatime <NR3>
- TRIGger:A:RISEFall:DELTatime?
Info
  • <NR3> is a floating point number that specifies the delta time, in seconds.

TriggerARisefallPolarity

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:RISEFall:POLarity command.

Description
  • This command specifies the polarity for the transition trigger.
Usage
  • Using the .query() method will send the TRIGger:A:RISEFall:POLarity? query.
  • Using the .verify(value) method will send the TRIGger:A:RISEFall:POLarity? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RISEFall:POLarity value command.
SCPI Syntax
- TRIGger:A:RISEFall:POLarity {EITher|NEGative|POSitive}
- TRIGger:A:RISEFall:POLarity?
Info
  • POSitive indicates that a pulse edge must traverse from the lower (most negative) to higher (most positive) level for transition triggering to occur.
  • NEGative indicates that a pulse edge must traverse from the upper (most positive) to lower (most negative) level for transition triggering to occur.
  • EITher indicates either positive or negative polarity.

TriggerARisefallSource

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:RISEFall:SOUrce command.

Description
  • This command specifies the source for a transition trigger.
Usage
  • Using the .query() method will send the TRIGger:A:RISEFall:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:RISEFall:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RISEFall:SOUrce value command.
SCPI Syntax
- TRIGger:A:RISEFall:SOUrce {CH<x>}
- TRIGger:A:RISEFall:SOUrce?
Info
  • CH<x> specifies one of the analog channels to be used as the source for a transition trigger.

TriggerARisefallWhen

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:RISEFall:WHEn command.

Description
  • This command specifies whether to check for a transitioning signal that is faster or slower than the specified delta time.
Usage
  • Using the .query() method will send the TRIGger:A:RISEFall:WHEn? query.
  • Using the .verify(value) method will send the TRIGger:A:RISEFall:WHEn? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RISEFall:WHEn value command.
SCPI Syntax
- TRIGger:A:RISEFall:WHEn {SLOWer|FASTer|EQual|UNEQual}
- TRIGger:A:RISEFall:WHEn?
Info
  • FASTer sets the trigger to occur when the signal transition time is faster than the time set by TRIGger:A:TRANsition:DELTatime.
  • SLOWer sets the trigger to occur when the signal transition time is slower than the time set by.TRIGger:A:TRANsition:DELTatime.
  • EQual sets the trigger to occur when the signal transition time is equal to the time set by TRIGger:A:TRANsition:DELTatime.
  • UNEQual sets the trigger to occur when the signal transition time is not equal to the time set by TRIGger:A:TRANsition:DELTatime.

TriggerARunt

Bases: SCPICmdRead

The TRIGger:A:RUNT command.

Description
  • Returns the current A runt trigger parameters.
Usage
  • Using the .query() method will send the TRIGger:A:RUNT? query.
  • Using the .verify(value) method will send the TRIGger:A:RUNT? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:RUNT?
Properties
  • .polarity: The TRIGger:A:RUNT:POLarity command.
  • .source: The TRIGger:A:RUNT:SOUrce command.
  • .when: The TRIGger:A:RUNT:WHEn command.
  • .width: The TRIGger:A:RUNT:WIDth command.

polarity property

Return the TRIGger:A:RUNT:POLarity command.

Description
  • This command specifies the polarity for the runt trigger.
Usage
  • Using the .query() method will send the TRIGger:A:RUNT:POLarity? query.
  • Using the .verify(value) method will send the TRIGger:A:RUNT:POLarity? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RUNT:POLarity value command.
SCPI Syntax
- TRIGger:A:RUNT:POLarity {EITher|NEGative|POSitive}
- TRIGger:A:RUNT:POLarity?
Info
  • POSitive indicates that the rising edge crosses the low threshold and the falling edge recrosses the low threshold without either edge ever crossing the high threshold.
  • NEGative indicates that the falling edge crosses the high threshold and the rising edge recrosses the high threshold without either edge ever crossing the low threshold.
  • EITher triggers on a runt of either polarity.

source property

Return the TRIGger:A:RUNT:SOUrce command.

Description
  • This command specifies the source waveform for the A runt trigger.
Usage
  • Using the .query() method will send the TRIGger:A:RUNT:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:RUNT:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RUNT:SOUrce value command.
SCPI Syntax
- TRIGger:A:RUNT:SOUrce {CH<x>|RF}
- TRIGger:A:RUNT:SOUrce?
Info
  • CH<x> specifies the analog channel number to use as the source waveform for the runt trigger. To specify the threshold levels when using CH1-CH4 as the source, use TRIGGER:A:LOWERTHRESHOLD:CHX and TRIGGER:A:UPPERTHRESHOLD:CHX. x has a minimum of 1 and a maximum of 4.
  • RF specifies the internal RF power level as the source (MDO4000/B/C models only, and requires installation of an MDO4TRIG application module.) To specify the threshold levels when using RF power level as the source, use TRIGGER:A:LOWERTHRESHOLD:RF and TRIGGER:A:UPPERTHRESHOLD:RF.

when property

Return the TRIGger:A:RUNT:WHEn command.

Description
  • This command specifies the type of pulse width the trigger checks for when it detects a runt.
Usage
  • Using the .query() method will send the TRIGger:A:RUNT:WHEn? query.
  • Using the .verify(value) method will send the TRIGger:A:RUNT:WHEn? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RUNT:WHEn value command.
SCPI Syntax
- TRIGger:A:RUNT:WHEn {LESSthan|MOREthan|EQual|UNEQual|OCCURS}
- TRIGger:A:RUNT:WHEn?
Info
  • OCCURS sets the instrument to trigger if a runt signal of any detectable width occurs.
  • LESSthan sets the instrument to trigger if the a runt pulse is detected with width less than the time set by the TRIGGER:A:RUNT:WIDTH command.
  • MOREthan sets the instrument to trigger if the a runt pulse is detected with width greater than the time set by the TRIGGER:A:RUNT:WIDTH command.
  • EQual sets the instrument to trigger if a runt pulse is detected with width equal to the time period specified in TRIGGER:A:RUNT:WIDTH within a ±5% tolerance.
  • UNEQual sets the instrument to trigger if a runt pulse is detected with width greater than or less than (but not equal to) the time period specified in TRIGGER:A:RUNT:WIDTH within a ±5% tolerance.

width property

Return the TRIGger:A:RUNT:WIDth command.

Description
  • This command specifies the width, in seconds, for a runt trigger.
Usage
  • Using the .query() method will send the TRIGger:A:RUNT:WIDth? query.
  • Using the .verify(value) method will send the TRIGger:A:RUNT:WIDth? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RUNT:WIDth value command.
SCPI Syntax
- TRIGger:A:RUNT:WIDth <NR3>
- TRIGger:A:RUNT:WIDth?
Info
  • <NR3> is a floating point number that specifies the minimum width, in seconds.

TriggerARuntPolarity

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:RUNT:POLarity command.

Description
  • This command specifies the polarity for the runt trigger.
Usage
  • Using the .query() method will send the TRIGger:A:RUNT:POLarity? query.
  • Using the .verify(value) method will send the TRIGger:A:RUNT:POLarity? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RUNT:POLarity value command.
SCPI Syntax
- TRIGger:A:RUNT:POLarity {EITher|NEGative|POSitive}
- TRIGger:A:RUNT:POLarity?
Info
  • POSitive indicates that the rising edge crosses the low threshold and the falling edge recrosses the low threshold without either edge ever crossing the high threshold.
  • NEGative indicates that the falling edge crosses the high threshold and the rising edge recrosses the high threshold without either edge ever crossing the low threshold.
  • EITher triggers on a runt of either polarity.

TriggerARuntSource

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:RUNT:SOUrce command.

Description
  • This command specifies the source waveform for the A runt trigger.
Usage
  • Using the .query() method will send the TRIGger:A:RUNT:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:RUNT:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RUNT:SOUrce value command.
SCPI Syntax
- TRIGger:A:RUNT:SOUrce {CH<x>|RF}
- TRIGger:A:RUNT:SOUrce?
Info
  • CH<x> specifies the analog channel number to use as the source waveform for the runt trigger. To specify the threshold levels when using CH1-CH4 as the source, use TRIGGER:A:LOWERTHRESHOLD:CHX and TRIGGER:A:UPPERTHRESHOLD:CHX. x has a minimum of 1 and a maximum of 4.
  • RF specifies the internal RF power level as the source (MDO4000/B/C models only, and requires installation of an MDO4TRIG application module.) To specify the threshold levels when using RF power level as the source, use TRIGGER:A:LOWERTHRESHOLD:RF and TRIGGER:A:UPPERTHRESHOLD:RF.

TriggerARuntWhen

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:RUNT:WHEn command.

Description
  • This command specifies the type of pulse width the trigger checks for when it detects a runt.
Usage
  • Using the .query() method will send the TRIGger:A:RUNT:WHEn? query.
  • Using the .verify(value) method will send the TRIGger:A:RUNT:WHEn? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RUNT:WHEn value command.
SCPI Syntax
- TRIGger:A:RUNT:WHEn {LESSthan|MOREthan|EQual|UNEQual|OCCURS}
- TRIGger:A:RUNT:WHEn?
Info
  • OCCURS sets the instrument to trigger if a runt signal of any detectable width occurs.
  • LESSthan sets the instrument to trigger if the a runt pulse is detected with width less than the time set by the TRIGGER:A:RUNT:WIDTH command.
  • MOREthan sets the instrument to trigger if the a runt pulse is detected with width greater than the time set by the TRIGGER:A:RUNT:WIDTH command.
  • EQual sets the instrument to trigger if a runt pulse is detected with width equal to the time period specified in TRIGGER:A:RUNT:WIDTH within a ±5% tolerance.
  • UNEQual sets the instrument to trigger if a runt pulse is detected with width greater than or less than (but not equal to) the time period specified in TRIGGER:A:RUNT:WIDTH within a ±5% tolerance.

TriggerARuntWidth

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:RUNT:WIDth command.

Description
  • This command specifies the width, in seconds, for a runt trigger.
Usage
  • Using the .query() method will send the TRIGger:A:RUNT:WIDth? query.
  • Using the .verify(value) method will send the TRIGger:A:RUNT:WIDth? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RUNT:WIDth value command.
SCPI Syntax
- TRIGger:A:RUNT:WIDth <NR3>
- TRIGger:A:RUNT:WIDth?
Info
  • <NR3> is a floating point number that specifies the minimum width, in seconds.

TriggerASethold

Bases: SCPICmdRead

The TRIGger:A:SETHold command.

Description
  • Returns the clock edge polarity, voltage threshold and source input; data voltage threshold and source; and both setup and hold times for setup and hold violation triggering.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:SETHold?
Properties
  • .clock: The TRIGger:A:SETHold:CLOCk command.
  • .data: The TRIGger:A:SETHold:DATa command.
  • .holdtime: The TRIGger:A:SETHold:HOLDTime command.
  • .settime: The TRIGger:A:SETHold:SETTime command.
  • .threshold: The TRIGger:A:SETHold:THReshold command tree.

clock property

Return the TRIGger:A:SETHold:CLOCk command.

Description
  • Returns the clock edge polarity, voltage threshold, and source input for setup and hold triggering.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:CLOCk? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:CLOCk? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:SETHold:CLOCk?
Sub-properties
  • .edge: The TRIGger:A:SETHold:CLOCk:EDGE command.
  • .source: The TRIGger:A:SETHold:CLOCk:SOUrce command.
  • .threshold: The TRIGger:A:SETHold:CLOCk:THReshold command.

data property

Return the TRIGger:A:SETHold:DATa command.

Description
  • Returns the voltage threshold and data source for the setup and hold trigger.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:DATa? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:SETHold:DATa?
Sub-properties
  • .source: The TRIGger:A:SETHold:DATa:SOUrce command.
  • .threshold: The TRIGger:A:SETHold:DATa:THReshold command.

holdtime property

Return the TRIGger:A:SETHold:HOLDTime command.

Description
  • This command specifies the hold time for setup and hold violation triggering. This command is equivalent to selecting Setup/Hold Setup from the Trig menu and then setting the desired Hold Time.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:HOLDTime? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:HOLDTime? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:HOLDTime value command.
SCPI Syntax
- TRIGger:A:SETHold:HOLDTime <NR3>
- TRIGger:A:SETHold:HOLDTime?
Info
  • <NR3> is a floating point number that specifies the hold time setting, in seconds. Positive values for hold time occur after the clock edge. Negative values occur before the clock edge.

settime property

Return the TRIGger:A:SETHold:SETTime command.

Description
  • This command specifies the setup time for setup and hold violation triggering. This command is equivalent to selecting Setup/Hold Setup from the Trig menu and then setting the desired Setup Time.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:SETTime? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:SETTime? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:SETTime value command.
SCPI Syntax
- TRIGger:A:SETHold:SETTime <NR3>
- TRIGger:A:SETHold:SETTime?
Info
  • <NR3> is a floating point number that specifies the setup time for setup and hold violation triggering.

threshold property

Return the TRIGger:A:SETHold:THReshold command tree.

Usage
  • Using the .query() method will send the TRIGger:A:SETHold:THReshold? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:THReshold? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .ch: The TRIGger:A:SETHold:THReshold:CH<x> command.
  • .d: The TRIGger:A:SETHold:THReshold:D<x> command.

TriggerASetholdClock

Bases: SCPICmdRead

The TRIGger:A:SETHold:CLOCk command.

Description
  • Returns the clock edge polarity, voltage threshold, and source input for setup and hold triggering.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:CLOCk? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:CLOCk? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:SETHold:CLOCk?
Properties
  • .edge: The TRIGger:A:SETHold:CLOCk:EDGE command.
  • .source: The TRIGger:A:SETHold:CLOCk:SOUrce command.
  • .threshold: The TRIGger:A:SETHold:CLOCk:THReshold command.

edge property

Return the TRIGger:A:SETHold:CLOCk:EDGE command.

Description
  • This command specifies the clock edge polarity for setup and hold triggering.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:CLOCk:EDGE? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:CLOCk:EDGE? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:CLOCk:EDGE value command.
SCPI Syntax
- TRIGger:A:SETHold:CLOCk:EDGE {FALL|RISe}
- TRIGger:A:SETHold:CLOCk:EDGE?
Info
  • FALL specifies polarity as the clock falling edge.
  • RISe specifies polarity as the clock rising edge.

source property

Return the TRIGger:A:SETHold:CLOCk:SOUrce command.

Description
  • This command specifies the clock source for the setup and hold triggering. You cannot specify the same source for both clock and data.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:CLOCk:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:CLOCk:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:CLOCk:SOUrce value command.
SCPI Syntax
- TRIGger:A:SETHold:CLOCk:SOUrce {CH<x>|D<x>|AUX}
- TRIGger:A:SETHold:CLOCk:SOUrce?
Info
  • CH<x> specifies the analog channel to use as the clock source waveform.
  • D<x> specifies the digital channel to use as the clock source waveform. (Requires option 3-MSO.).
  • AUX specifies an external trigger using the Aux In connector located on the front panel of the oscilloscope. (Available for 2-channel MDO32, as it has an Aux Input connector.).

threshold property

Return the TRIGger:A:SETHold:CLOCk:THReshold command.

Description
  • This command specifies the clock voltage threshold for the setup and hold trigger.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:CLOCk:THReshold? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:CLOCk:THReshold? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:CLOCk:THReshold value command.
SCPI Syntax
- TRIGger:A:SETHold:CLOCk:THReshold {<NR3>|TTL}
- TRIGger:A:SETHold:CLOCk:THReshold?
Info
  • <NR3> is a floating point number that specifies the clock level, in volts.
  • TTL specifies a preset TTL high level of 1.4 V.

TriggerASetholdClockEdge

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:SETHold:CLOCk:EDGE command.

Description
  • This command specifies the clock edge polarity for setup and hold triggering.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:CLOCk:EDGE? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:CLOCk:EDGE? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:CLOCk:EDGE value command.
SCPI Syntax
- TRIGger:A:SETHold:CLOCk:EDGE {FALL|RISe}
- TRIGger:A:SETHold:CLOCk:EDGE?
Info
  • FALL specifies polarity as the clock falling edge.
  • RISe specifies polarity as the clock rising edge.

TriggerASetholdClockSource

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:SETHold:CLOCk:SOUrce command.

Description
  • This command specifies the clock source for the setup and hold triggering. You cannot specify the same source for both clock and data.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:CLOCk:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:CLOCk:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:CLOCk:SOUrce value command.
SCPI Syntax
- TRIGger:A:SETHold:CLOCk:SOUrce {CH<x>|D<x>|AUX}
- TRIGger:A:SETHold:CLOCk:SOUrce?
Info
  • CH<x> specifies the analog channel to use as the clock source waveform.
  • D<x> specifies the digital channel to use as the clock source waveform. (Requires option 3-MSO.).
  • AUX specifies an external trigger using the Aux In connector located on the front panel of the oscilloscope. (Available for 2-channel MDO32, as it has an Aux Input connector.).

TriggerASetholdClockThreshold

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:SETHold:CLOCk:THReshold command.

Description
  • This command specifies the clock voltage threshold for the setup and hold trigger.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:CLOCk:THReshold? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:CLOCk:THReshold? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:CLOCk:THReshold value command.
SCPI Syntax
- TRIGger:A:SETHold:CLOCk:THReshold {<NR3>|TTL}
- TRIGger:A:SETHold:CLOCk:THReshold?
Info
  • <NR3> is a floating point number that specifies the clock level, in volts.
  • TTL specifies a preset TTL high level of 1.4 V.

TriggerASetholdData

Bases: SCPICmdRead

The TRIGger:A:SETHold:DATa command.

Description
  • Returns the voltage threshold and data source for the setup and hold trigger.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:DATa? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:SETHold:DATa?
Properties
  • .source: The TRIGger:A:SETHold:DATa:SOUrce command.
  • .threshold: The TRIGger:A:SETHold:DATa:THReshold command.

source property

Return the TRIGger:A:SETHold:DATa:SOUrce command.

Description
  • This command specifies the data source or sources for setup and hold triggering. You can specify any combination of sources as long as none of them are also the clock source. Requires installation of option 3-MSO, which enables you to specify any combination of CH1-CH4 and D0-D15 as the data sources. For 2-channel MDO32, you can also use Aux Input.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:DATa:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:DATa:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:DATa:SOUrce value command.
SCPI Syntax
- TRIGger:A:SETHold:DATa:SOUrce {CH<x>|D<x>|AUX}
- TRIGger:A:SETHold:DATa:SOUrce?
Info
  • CH<x> specifies an analog input channel as the data source for the setup and hold trigger.
  • D<x> specifies a digital channel as the source. Requires option 3-MSO.
  • AUX specifies an external trigger using the Aux In connector located on the front panel of the oscilloscope. (For 2-channel MDO32 only.).

threshold property

Return the TRIGger:A:SETHold:DATa:THReshold command.

Description
  • This command specifies the data voltage threshold for setup and hold trigger.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:DATa:THReshold? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:DATa:THReshold? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:DATa:THReshold value command.
SCPI Syntax
- TRIGger:A:SETHold:DATa:THReshold {<NR3>|TTL}
- TRIGger:A:SETHold:DATa:THReshold?
Info
  • TTL specifies the preset TTL high level of 1.4 V.
  • <NR3> is a floating point number that specifies the setup and hold data level, in volts.

TriggerASetholdDataSource

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:SETHold:DATa:SOUrce command.

Description
  • This command specifies the data source or sources for setup and hold triggering. You can specify any combination of sources as long as none of them are also the clock source. Requires installation of option 3-MSO, which enables you to specify any combination of CH1-CH4 and D0-D15 as the data sources. For 2-channel MDO32, you can also use Aux Input.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:DATa:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:DATa:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:DATa:SOUrce value command.
SCPI Syntax
- TRIGger:A:SETHold:DATa:SOUrce {CH<x>|D<x>|AUX}
- TRIGger:A:SETHold:DATa:SOUrce?
Info
  • CH<x> specifies an analog input channel as the data source for the setup and hold trigger.
  • D<x> specifies a digital channel as the source. Requires option 3-MSO.
  • AUX specifies an external trigger using the Aux In connector located on the front panel of the oscilloscope. (For 2-channel MDO32 only.).

TriggerASetholdDataThreshold

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:SETHold:DATa:THReshold command.

Description
  • This command specifies the data voltage threshold for setup and hold trigger.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:DATa:THReshold? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:DATa:THReshold? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:DATa:THReshold value command.
SCPI Syntax
- TRIGger:A:SETHold:DATa:THReshold {<NR3>|TTL}
- TRIGger:A:SETHold:DATa:THReshold?
Info
  • TTL specifies the preset TTL high level of 1.4 V.
  • <NR3> is a floating point number that specifies the setup and hold data level, in volts.

TriggerASetholdHoldtime

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:SETHold:HOLDTime command.

Description
  • This command specifies the hold time for setup and hold violation triggering. This command is equivalent to selecting Setup/Hold Setup from the Trig menu and then setting the desired Hold Time.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:HOLDTime? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:HOLDTime? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:HOLDTime value command.
SCPI Syntax
- TRIGger:A:SETHold:HOLDTime <NR3>
- TRIGger:A:SETHold:HOLDTime?
Info
  • <NR3> is a floating point number that specifies the hold time setting, in seconds. Positive values for hold time occur after the clock edge. Negative values occur before the clock edge.

TriggerASetholdSettime

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:SETHold:SETTime command.

Description
  • This command specifies the setup time for setup and hold violation triggering. This command is equivalent to selecting Setup/Hold Setup from the Trig menu and then setting the desired Setup Time.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:SETTime? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:SETTime? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:SETTime value command.
SCPI Syntax
- TRIGger:A:SETHold:SETTime <NR3>
- TRIGger:A:SETHold:SETTime?
Info
  • <NR3> is a floating point number that specifies the setup time for setup and hold violation triggering.

TriggerASetholdThreshold

Bases: SCPICmdRead

The TRIGger:A:SETHold:THReshold command tree.

Usage
  • Using the .query() method will send the TRIGger:A:SETHold:THReshold? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:THReshold? query and raise an AssertionError if the returned value does not match value.
Properties
  • .ch: The TRIGger:A:SETHold:THReshold:CH<x> command.
  • .d: The TRIGger:A:SETHold:THReshold:D<x> command.

ch property

Return the TRIGger:A:SETHold:THReshold:CH<x> command.

Description
  • This command specifies the threshold for the analog channel . x can be 1-4. All trigger types using the channel are affected.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:THReshold:CH<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:THReshold:CH<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:THReshold:CH<x> value command.
SCPI Syntax
- TRIGger:A:SETHold:THReshold:CH<x> {<NR3>|ECL|TTL}
- TRIGger:A:SETHold:THReshold:CH<x>?
Info
  • <NR3> is a floating point number that specifies the threshold voltage, in volts.
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.

d property

Return the TRIGger:A:SETHold:THReshold:D<x> command.

Description
  • This command sets the threshold for the specified digital channel. can be D0 - D15. All trigger types using the digital channel are affected.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:THReshold:D<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:THReshold:D<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:THReshold:D<x> value command.
SCPI Syntax
- TRIGger:A:SETHold:THReshold:D<x> {<NR3>|ECL|TTL}
- TRIGger:A:SETHold:THReshold:D<x>?
Info
  • <NR3> is a floating point number that specifies the threshold voltage, in volts.
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.

TriggerASetholdThresholdChannel

Bases: ValidatedChannel, SCPICmdWrite, SCPICmdRead

The TRIGger:A:SETHold:THReshold:CH<x> command.

Description
  • This command specifies the threshold for the analog channel . x can be 1-4. All trigger types using the channel are affected.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:THReshold:CH<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:THReshold:CH<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:THReshold:CH<x> value command.
SCPI Syntax
- TRIGger:A:SETHold:THReshold:CH<x> {<NR3>|ECL|TTL}
- TRIGger:A:SETHold:THReshold:CH<x>?
Info
  • <NR3> is a floating point number that specifies the threshold voltage, in volts.
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.

TriggerASetholdThresholdDigitalBit

Bases: ValidatedDigitalBit, SCPICmdWrite, SCPICmdRead

The TRIGger:A:SETHold:THReshold:D<x> command.

Description
  • This command sets the threshold for the specified digital channel. can be D0 - D15. All trigger types using the digital channel are affected.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:THReshold:D<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:THReshold:D<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:THReshold:D<x> value command.
SCPI Syntax
- TRIGger:A:SETHold:THReshold:D<x> {<NR3>|ECL|TTL}
- TRIGger:A:SETHold:THReshold:D<x>?
Info
  • <NR3> is a floating point number that specifies the threshold voltage, in volts.
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.

TriggerATimeout

Bases: SCPICmdRead

The TRIGger:A:TIMEOut command tree.

Usage
  • Using the .query() method will send the TRIGger:A:TIMEOut? query.
  • Using the .verify(value) method will send the TRIGger:A:TIMEOut? query and raise an AssertionError if the returned value does not match value.
Properties
  • .polarity: The TRIGger:A:TIMEOut:POLarity command.
  • .source: The TRIGger:A:TIMEOut:SOUrce command.
  • .time: The TRIGger:A:TIMEOut:TIMe command.

polarity property

Return the TRIGger:A:TIMEOut:POLarity command.

Description
  • When triggering using the TIMEOut trigger type, this commands specifies the polarity to be used.
Usage
  • Using the .query() method will send the TRIGger:A:TIMEOut:POLarity? query.
  • Using the .verify(value) method will send the TRIGger:A:TIMEOut:POLarity? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:TIMEOut:POLarity value command.
SCPI Syntax
- TRIGger:A:TIMEOut:POLarity {STAYSHigh|STAYSLow|EITher}
- TRIGger:A:TIMEOut:POLarity?
Info
  • STAYSHigh . Trigger when the signal stays high during the timeout time specified by the command TRIGGER:A:TIMEOUT:TIME.
  • STAYSLow . Trigger when the signal stays low during the timeout time specified by the command TRIGGER:A:TIMEOUT:TIME.
  • EITher . Trigger when the signal is either high or low during the timeout time specified by the command TRIGGER:A:TIMEOUT:TIME.

source property

Return the TRIGger:A:TIMEOut:SOUrce command.

Description
  • When triggering using the TIMEOut trigger type, this command specifies the source. The available sources are live channels, the digital channels, the Aux Input connector (for 2-channel MDO32 model only). The default is channel 1. The timeout trigger type is selected using TRIGGER:A:PULSE:CLASS TIMEOut.
Usage
  • Using the .query() method will send the TRIGger:A:TIMEOut:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:TIMEOut:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:TIMEOut:SOUrce value command.
SCPI Syntax
- TRIGger:A:TIMEOut:SOUrce {CH<x>|LINE|AUX|D<x>|RF}
- TRIGger:A:TIMEOut:SOUrce?
Info
  • CH<x> specifies an analog channel as the timeout trigger source.
  • AUX specifies an external trigger using the Aux In connector located on the front panel of the oscilloscope. (For 2-channel MDO32 model only.).
  • LINE specifies the AC line as the timeout trigger source.
  • D<x> specifies a digital channel as the timeout trigger source. (Requires option 3-MSO.).

time property

Return the TRIGger:A:TIMEOut:TIMe command.

Description
  • When triggering using the TIMEOut trigger type, this command specifies the timeout time, in seconds. This command is equivalent to selecting Timeout from the Trig menu and setting a value for Time Limit. The timeout trigger type is selected using TRIGGER:A:TYPE TIMEOut
Usage
  • Using the .query() method will send the TRIGger:A:TIMEOut:TIMe? query.
  • Using the .verify(value) method will send the TRIGger:A:TIMEOut:TIMe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:TIMEOut:TIMe value command.
SCPI Syntax
- TRIGger:A:TIMEOut:TIMe <NR3>
- TRIGger:A:TIMEOut:TIMe?
Info
  • <NR3> is a floating point number that specifies the timeout time, in seconds.

TriggerATimeoutPolarity

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:TIMEOut:POLarity command.

Description
  • When triggering using the TIMEOut trigger type, this commands specifies the polarity to be used.
Usage
  • Using the .query() method will send the TRIGger:A:TIMEOut:POLarity? query.
  • Using the .verify(value) method will send the TRIGger:A:TIMEOut:POLarity? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:TIMEOut:POLarity value command.
SCPI Syntax
- TRIGger:A:TIMEOut:POLarity {STAYSHigh|STAYSLow|EITher}
- TRIGger:A:TIMEOut:POLarity?
Info
  • STAYSHigh . Trigger when the signal stays high during the timeout time specified by the command TRIGGER:A:TIMEOUT:TIME.
  • STAYSLow . Trigger when the signal stays low during the timeout time specified by the command TRIGGER:A:TIMEOUT:TIME.
  • EITher . Trigger when the signal is either high or low during the timeout time specified by the command TRIGGER:A:TIMEOUT:TIME.

TriggerATimeoutSource

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:TIMEOut:SOUrce command.

Description
  • When triggering using the TIMEOut trigger type, this command specifies the source. The available sources are live channels, the digital channels, the Aux Input connector (for 2-channel MDO32 model only). The default is channel 1. The timeout trigger type is selected using TRIGGER:A:PULSE:CLASS TIMEOut.
Usage
  • Using the .query() method will send the TRIGger:A:TIMEOut:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:TIMEOut:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:TIMEOut:SOUrce value command.
SCPI Syntax
- TRIGger:A:TIMEOut:SOUrce {CH<x>|LINE|AUX|D<x>|RF}
- TRIGger:A:TIMEOut:SOUrce?
Info
  • CH<x> specifies an analog channel as the timeout trigger source.
  • AUX specifies an external trigger using the Aux In connector located on the front panel of the oscilloscope. (For 2-channel MDO32 model only.).
  • LINE specifies the AC line as the timeout trigger source.
  • D<x> specifies a digital channel as the timeout trigger source. (Requires option 3-MSO.).

TriggerATimeoutTime

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:TIMEOut:TIMe command.

Description
  • When triggering using the TIMEOut trigger type, this command specifies the timeout time, in seconds. This command is equivalent to selecting Timeout from the Trig menu and setting a value for Time Limit. The timeout trigger type is selected using TRIGGER:A:TYPE TIMEOut
Usage
  • Using the .query() method will send the TRIGger:A:TIMEOut:TIMe? query.
  • Using the .verify(value) method will send the TRIGger:A:TIMEOut:TIMe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:TIMEOut:TIMe value command.
SCPI Syntax
- TRIGger:A:TIMEOut:TIMe <NR3>
- TRIGger:A:TIMEOut:TIMe?
Info
  • <NR3> is a floating point number that specifies the timeout time, in seconds.

TriggerATransition

Bases: SCPICmdRead

The TRIGger:A:TRANsition command.

Description
  • Returns transition time trigger parameters.
Usage
  • Using the .query() method will send the TRIGger:A:TRANsition? query.
  • Using the .verify(value) method will send the TRIGger:A:TRANsition? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:TRANsition?
Properties
  • .deltatime: The TRIGger:A:TRANsition:DELTatime command.
  • .polarity: The TRIGger:A:TRANsition:POLarity command.
  • .source: The TRIGger:A:TRANsition:SOUrce command.
  • .when: The TRIGger:A:TRANsition:WHEn command.

deltatime property

Return the TRIGger:A:TRANsition:DELTatime command.

Description
  • This command specifies the delta time used in calculating the transition value for the transition trigger.
Usage
  • Using the .query() method will send the TRIGger:A:TRANsition:DELTatime? query.
  • Using the .verify(value) method will send the TRIGger:A:TRANsition:DELTatime? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:TRANsition:DELTatime value command.
SCPI Syntax
- TRIGger:A:TRANsition:DELTatime <NR3>
- TRIGger:A:TRANsition:DELTatime?
Info
  • <NR3> is a floating point number that specifies the delta time, in seconds.

polarity property

Return the TRIGger:A:TRANsition:POLarity command.

Description
  • This command specifies the polarity for the transition trigger.
Usage
  • Using the .query() method will send the TRIGger:A:TRANsition:POLarity? query.
  • Using the .verify(value) method will send the TRIGger:A:TRANsition:POLarity? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:TRANsition:POLarity value command.
SCPI Syntax
- TRIGger:A:TRANsition:POLarity {EITher|NEGative|POSitive}
- TRIGger:A:TRANsition:POLarity?
Info
  • POSitive indicates that a pulse edge must traverse from the lower (most negative) to higher (most positive) level for transition triggering to occur.
  • NEGative indicates that a pulse edge must traverse from the upper (most positive) to lower (most negative) level for transition triggering to occur.
  • EITher indicates either positive or negative polarity.

source property

Return the TRIGger:A:TRANsition:SOUrce command.

Description
  • This command specifies the source for a transition trigger.
Usage
  • Using the .query() method will send the TRIGger:A:TRANsition:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:TRANsition:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:TRANsition:SOUrce value command.
SCPI Syntax
- TRIGger:A:TRANsition:SOUrce {CH<x>}
- TRIGger:A:TRANsition:SOUrce?
Info
  • CH<x> specifies one of the analog channels to be used as the source for a transition trigger.

when property

Return the TRIGger:A:TRANsition:WHEn command.

Description
  • This command specifies whether to check for a transitioning signal that is faster or slower than the specified delta time.
Usage
  • Using the .query() method will send the TRIGger:A:TRANsition:WHEn? query.
  • Using the .verify(value) method will send the TRIGger:A:TRANsition:WHEn? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:TRANsition:WHEn value command.
SCPI Syntax
- TRIGger:A:TRANsition:WHEn {SLOWer|FASTer|EQual|UNEQual}
- TRIGger:A:TRANsition:WHEn?
Info
  • FASTer sets the trigger to occur when the signal transition time is faster than the time set by TRIGger:A:TRANsition:DELTatime.
  • SLOWer sets the trigger to occur when the signal transition time is slower than the time set by.TRIGger:A:TRANsition:DELTatime.
  • EQual sets the trigger to occur when the signal transition time is equal to the time set by TRIGger:A:TRANsition:DELTatime.
  • UNEQual sets the trigger to occur when the signal transition time is not equal to the time set by TRIGger:A:TRANsition:DELTatime.

TriggerATransitionDeltatime

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:TRANsition:DELTatime command.

Description
  • This command specifies the delta time used in calculating the transition value for the transition trigger.
Usage
  • Using the .query() method will send the TRIGger:A:TRANsition:DELTatime? query.
  • Using the .verify(value) method will send the TRIGger:A:TRANsition:DELTatime? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:TRANsition:DELTatime value command.
SCPI Syntax
- TRIGger:A:TRANsition:DELTatime <NR3>
- TRIGger:A:TRANsition:DELTatime?
Info
  • <NR3> is a floating point number that specifies the delta time, in seconds.

TriggerATransitionPolarity

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:TRANsition:POLarity command.

Description
  • This command specifies the polarity for the transition trigger.
Usage
  • Using the .query() method will send the TRIGger:A:TRANsition:POLarity? query.
  • Using the .verify(value) method will send the TRIGger:A:TRANsition:POLarity? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:TRANsition:POLarity value command.
SCPI Syntax
- TRIGger:A:TRANsition:POLarity {EITher|NEGative|POSitive}
- TRIGger:A:TRANsition:POLarity?
Info
  • POSitive indicates that a pulse edge must traverse from the lower (most negative) to higher (most positive) level for transition triggering to occur.
  • NEGative indicates that a pulse edge must traverse from the upper (most positive) to lower (most negative) level for transition triggering to occur.
  • EITher indicates either positive or negative polarity.

TriggerATransitionSource

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:TRANsition:SOUrce command.

Description
  • This command specifies the source for a transition trigger.
Usage
  • Using the .query() method will send the TRIGger:A:TRANsition:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:TRANsition:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:TRANsition:SOUrce value command.
SCPI Syntax
- TRIGger:A:TRANsition:SOUrce {CH<x>}
- TRIGger:A:TRANsition:SOUrce?
Info
  • CH<x> specifies one of the analog channels to be used as the source for a transition trigger.

TriggerATransitionWhen

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:TRANsition:WHEn command.

Description
  • This command specifies whether to check for a transitioning signal that is faster or slower than the specified delta time.
Usage
  • Using the .query() method will send the TRIGger:A:TRANsition:WHEn? query.
  • Using the .verify(value) method will send the TRIGger:A:TRANsition:WHEn? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:TRANsition:WHEn value command.
SCPI Syntax
- TRIGger:A:TRANsition:WHEn {SLOWer|FASTer|EQual|UNEQual}
- TRIGger:A:TRANsition:WHEn?
Info
  • FASTer sets the trigger to occur when the signal transition time is faster than the time set by TRIGger:A:TRANsition:DELTatime.
  • SLOWer sets the trigger to occur when the signal transition time is slower than the time set by.TRIGger:A:TRANsition:DELTatime.
  • EQual sets the trigger to occur when the signal transition time is equal to the time set by TRIGger:A:TRANsition:DELTatime.
  • UNEQual sets the trigger to occur when the signal transition time is not equal to the time set by TRIGger:A:TRANsition:DELTatime.

TriggerAType

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:TYPe command.

Description
  • This command sets the type of A trigger (either edge, logic, pulse, bus or video). If you set the trigger type to LOGIc, you also need to set the logic trigger class (logic or setup/hold) using the command TRIGGER:A:LOGIC:CLASS. If you set the trigger type to PULSe, you also need to set the pulse trigger class (either runt, width, transition or timeout), using the command TRIGGER:A:PULSE:CLASS. If you set the trigger type to BUS, you also need to set the bus type (CAN, I 2 C, SPI, RS-232, Ethernet, MIL-STD-1553, LIN, USB, audio, FlexRay, or parallel) using the command TRIGGER:A:BUS.
Usage
  • Using the .query() method will send the TRIGger:A:TYPe? query.
  • Using the .verify(value) method will send the TRIGger:A:TYPe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:TYPe value command.
SCPI Syntax
- TRIGger:A:TYPe {EDGe|LOGIc|PULSe|BUS|VIDeo}
- TRIGger:A:TYPe?
Info
  • EDGe is the default trigger. A trigger event occurs when a signal passes through a specified voltage level in a specified direction and is controlled by the TRIGGER:A:EDGE commands.
  • LOGIc specifies that a trigger occurs when specified conditions are met and is controlled by the TRIGGER:A:LOGIC commands. This trigger type is equivalent to the logic and setup/hold triggers found in the user interface. Use TRIGGER:A:LOGIC:CLASS to further select the logic trigger class (either LOGIC or SETHOLD).
  • PULSe specifies that a trigger occurs when a specified pulse is found. Use TRIGGER:A:PULSE:CLASS to further select the pulse trigger class (either runt, width, transition or timeout).
  • BUS specifies that a trigger occurs when a bus signal is found. Supports CAN, I2C, SPI, RS-232, Ethernet, MIL-STD-1553, LIN, USB, audio, FlexRay buses (with the appropriate application module installed) as well as parallel buses. Requires the installation of option 3-MSO. Use TRIGGER:A:BUS to set the bus type.
  • VIDeo specifies that the trigger occurs when a video signal is found.

TriggerAUpperthreshold

Bases: SCPICmdRead

The TRIGger:A:UPPerthreshold command tree.

Usage
  • Using the .query() method will send the TRIGger:A:UPPerthreshold? query.
  • Using the .verify(value) method will send the TRIGger:A:UPPerthreshold? query and raise an AssertionError if the returned value does not match value.
Properties
  • .ch: The TRIGger:A:UPPerthreshold:CH<x> command.
  • .rf: The TRIGger:A:UPPerthreshold:RF command.

ch property

Return the TRIGger:A:UPPerthreshold:CH<x> command.

Description
  • This command sets the upper threshold for channel , where x is the analog channel number 1-4. Each channel can have an independent level. Used only for runt and transition trigger types.
Usage
  • Using the .query() method will send the TRIGger:A:UPPerthreshold:CH<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:UPPerthreshold:CH<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:UPPerthreshold:CH<x> value command.
SCPI Syntax
- TRIGger:A:UPPerthreshold:CH<x> {<NR3>|ECL|TTL}
- TRIGger:A:UPPerthreshold:CH<x>?
Info
  • <NR3> is a floating point number that specifies the threshold level, in volts.
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.

rf property

Return the TRIGger:A:UPPerthreshold:RF command.

Description
  • This command specifies the upper threshold when the internal RF power level is used during runt triggering. To specify the lower threshold for the RUNT trigger type as well as the single threshold for the Pulse and Timeout trigger types, use the command TRIGGER:A:LOWERTHRESHOLD:RF. To choose the RUNT trigger type, use the command TRIGGER:A:PULSE:CLASS. To specify RF power as a source during runt triggering, use TRIGGER:A:RUNT:SOURCE.
Usage
  • Using the .query() method will send the TRIGger:A:UPPerthreshold:RF? query.
  • Using the .verify(value) method will send the TRIGger:A:UPPerthreshold:RF? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:UPPerthreshold:RF value command.
SCPI Syntax
- TRIGger:A:UPPerthreshold:RF {<NR3>}
- TRIGger:A:UPPerthreshold:RF?
Info
  • <NR3> is a floating point number that specifies the threshold to use, in the currently selected RF units (using RF:UNITS). The range is (ref level - 40 dBm) to (ref level + 10 dBm), but never less than -65 dBm or more than +30 dBm.

TriggerAUpperthresholdChannel

Bases: ValidatedChannel, SCPICmdWrite, SCPICmdRead

The TRIGger:A:UPPerthreshold:CH<x> command.

Description
  • This command sets the upper threshold for channel , where x is the analog channel number 1-4. Each channel can have an independent level. Used only for runt and transition trigger types.
Usage
  • Using the .query() method will send the TRIGger:A:UPPerthreshold:CH<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:UPPerthreshold:CH<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:UPPerthreshold:CH<x> value command.
SCPI Syntax
- TRIGger:A:UPPerthreshold:CH<x> {<NR3>|ECL|TTL}
- TRIGger:A:UPPerthreshold:CH<x>?
Info
  • <NR3> is a floating point number that specifies the threshold level, in volts.
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.

TriggerAUpperthresholdRf

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:UPPerthreshold:RF command.

Description
  • This command specifies the upper threshold when the internal RF power level is used during runt triggering. To specify the lower threshold for the RUNT trigger type as well as the single threshold for the Pulse and Timeout trigger types, use the command TRIGGER:A:LOWERTHRESHOLD:RF. To choose the RUNT trigger type, use the command TRIGGER:A:PULSE:CLASS. To specify RF power as a source during runt triggering, use TRIGGER:A:RUNT:SOURCE.
Usage
  • Using the .query() method will send the TRIGger:A:UPPerthreshold:RF? query.
  • Using the .verify(value) method will send the TRIGger:A:UPPerthreshold:RF? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:UPPerthreshold:RF value command.
SCPI Syntax
- TRIGger:A:UPPerthreshold:RF {<NR3>}
- TRIGger:A:UPPerthreshold:RF?
Info
  • <NR3> is a floating point number that specifies the threshold to use, in the currently selected RF units (using RF:UNITS). The range is (ref level - 40 dBm) to (ref level + 10 dBm), but never less than -65 dBm or more than +30 dBm.

TriggerAVideo

Bases: SCPICmdRead

The TRIGger:A:VIDeo command.

Description
  • Returns the A trigger video parameters.
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:VIDeo?
Properties
  • .custom: The TRIGger:A:VIDeo:CUSTom command tree.
  • .holdoff: The TRIGger:A:VIDeo:HOLDoff command tree.
  • .line: The TRIGger:A:VIDeo:LINE command.
  • .polarity: The TRIGger:A:VIDeo:POLarity command.
  • .source: The TRIGger:A:VIDeo:SOUrce command.
  • .standard: The TRIGger:A:VIDeo:STANdard command.
  • .sync: The TRIGger:A:VIDeo:SYNC command.
  • .field: The TRIGger:A:VIDeo:FIELD command.

custom property

Return the TRIGger:A:VIDeo:CUSTom command tree.

Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:CUSTom? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:CUSTom? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .lineperiod: The TRIGger:A:VIDeo:CUSTom:LINEPeriod command.
  • .syncinterval: The TRIGger:A:VIDeo:CUSTom:SYNCInterval command.
  • .format: The TRIGger:A:VIDeo:CUSTom:FORMat command.
  • .type: The TRIGger:A:VIDeo:CUSTom:TYPe command.

field property

Return the TRIGger:A:VIDeo:FIELD command.

Description
  • This command sets the video field to use for triggering on video signals (odd fields, even fields, all fields, all lines, numeric).
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:FIELD? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:FIELD? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:FIELD value command.
SCPI Syntax
- TRIGger:A:VIDeo:FIELD {ODD|EVEN|ALLFields|ALLLines|NUMERic}
- TRIGger:A:VIDeo:FIELD?
Info
  • ODD argument sets the oscilloscope to trigger on interlaced video odd fields.
  • EVEN argument sets the oscilloscope to trigger on interlaced video even fields.
  • ALLFields argument sets the oscilloscope to trigger on all fields.
  • ALLLines argument sets the oscilloscope to trigger on all video lines.
  • NUMERic argument sets the oscilloscope to trigger on the video signal line specified by the TRIGGER:A:VIDEO:LINE command.

holdoff property

Return the TRIGger:A:VIDeo:HOLDoff command tree.

Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:HOLDoff? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:HOLDoff? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .field: The TRIGger:A:VIDeo:HOLDoff:FIELD command.

line property

Return the TRIGger:A:VIDeo:LINE command.

Description
  • This command lets you set the specific video line number to be used for triggering on a video signal. You must also use the command to specify NUMERic as the video field to use.
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:LINE? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:LINE? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:LINE value command.
SCPI Syntax
- TRIGger:A:VIDeo:LINE <NR1>
- TRIGger:A:VIDeo:LINE?
Info
  • <NR1> argument is an integer that sets the video line number on which the oscilloscope triggers. The following table lists the valid choices, depending on the active video standard.

polarity property

Return the TRIGger:A:VIDeo:POLarity command.

Description
  • This command sets the polarity to use for triggering on video signals.
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:POLarity? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:POLarity? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:POLarity value command.
SCPI Syntax
- TRIGger:A:VIDeo:POLarity {NEGative|POSitive}
- TRIGger:A:VIDeo:POLarity?
Info
  • POSitive argument sets the oscilloscope to trigger on a positive video sync pulse.
  • NEGative argument sets the oscilloscope to trigger on a negative video sync pulse.

source property

Return the TRIGger:A:VIDeo:SOUrce command.

Description
  • This command sets the source channel to use for triggering on video signals (CH1-4).
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:SOUrce value command.
SCPI Syntax
- TRIGger:A:VIDeo:SOUrce {CH<x>}
- TRIGger:A:VIDeo:SOUrce?
Info
  • CH<x> specifies the input channel to use as the A video trigger. x has a minimum of 1 and a maximum of 4.

standard property

Return the TRIGger:A:VIDeo:STANdard command.

Description
  • This command sets the standard to use for triggering on video signals.
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:STANdard? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:STANdard? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:STANdard value command.
SCPI Syntax
- TRIGger:A:VIDeo:STANdard {NTSc|PAL|SECAM|BILevelcustom|TRILevelcustom|HD480P60|HD576P50|HD720P30|HD720P50|HD720P60|HD875I60|HD1080P24|HD1080SF24|HD1080I50|HD1080I60|HD1080P25|HD1080P30|HD1080P50|HD1080P60}
- TRIGger:A:VIDeo:STANdard?
Info
  • NTSc sets the oscilloscope to trigger on video signals that meet the NTSC 525/60/2:1 standard (a line rate of 525 lines per frame and a field rate of 60 Hz).
  • PAL sets the oscilloscope to trigger on video signals that meet the NTSC 625/50/2:1 standard (a line rate of 625 lines per frame and a field rate of 50 Hz).
  • SECAM sets the oscilloscope to trigger on video signals that meet the SECAM standard.
  • BILevelcustom sets the oscilloscope to trigger on video horizontal scan rate parameters defined by the.
  • TRILevelcustom sets the oscilloscope to trigger on video horizontal scan rate parameters defined by the.
  • HD480P60 set the oscilloscope to trigger on an HDTV video signal that meets standards defined in the following table.
  • HD576P50 set the oscilloscope to trigger on an HDTV video signal that meets standards defined in the following table.
  • HD720P30 set the oscilloscope to trigger on an HDTV video signal that meets standards defined in the following table.
  • HD720P50 set the oscilloscope to trigger on an HDTV video signal that meets standards defined in the following table.
  • HD720P60 set the oscilloscope to trigger on an HDTV video signal that meets standards defined in the following table.
  • HD875I60 set the oscilloscope to trigger on an HDTV video signal that meets standards defined in the following table.
  • HD1080P24 set the oscilloscope to trigger on an HDTV video signal that meets standards defined in the following table.
  • HD1080SF24 set the oscilloscope to trigger on an HDTV video signal that meets standards defined in the following table.
  • HD1080I50 set the oscilloscope to trigger on an HDTV video signal that meets standards defined in the following table.
  • HD1080I60 set the oscilloscope to trigger on an HDTV video signal that meets standards defined in the following table.
  • HD1080P25 set the oscilloscope to trigger on an HDTV video signal that meets standards defined in the following table.
  • HD1080P30 set the oscilloscope to trigger on an HDTV video signal that meets standards defined in the following table.
  • HD1080P50 set the oscilloscope to trigger on an HDTV video signal that meets standards defined in the following table.
  • HD1080P60 set the oscilloscope to trigger on an HDTV video signal that meets standards defined in the following table.

sync property

Return the TRIGger:A:VIDeo:SYNC command.

Description
  • This command sets the video field to use for triggering on video signals (odd fields, even fields, all fields, all lines, numeric).
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:SYNC? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:SYNC? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:SYNC value command.
SCPI Syntax
- TRIGger:A:VIDeo:SYNC {ODD|EVEN|ALLFields|ALLLines|NUMERic}
- TRIGger:A:VIDeo:SYNC?
Info
  • ODD argument sets the oscilloscope to trigger on interlaced video odd fields.
  • EVEN argument sets the oscilloscope to trigger on interlaced video even fields.
  • ALLFields argument sets the oscilloscope to trigger on all fields.
  • ALLLines argument sets the oscilloscope to trigger on all video lines.
  • NUMERic argument sets the oscilloscope to trigger on the video signal line specified by the TRIGGER:A:VIDEO:LINE command.

TriggerAVideoCustom

Bases: SCPICmdRead

The TRIGger:A:VIDeo:CUSTom command tree.

Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:CUSTom? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:CUSTom? query and raise an AssertionError if the returned value does not match value.
Properties
  • .lineperiod: The TRIGger:A:VIDeo:CUSTom:LINEPeriod command.
  • .syncinterval: The TRIGger:A:VIDeo:CUSTom:SYNCInterval command.
  • .format: The TRIGger:A:VIDeo:CUSTom:FORMat command.
  • .type: The TRIGger:A:VIDeo:CUSTom:TYPe command.

format property

Return the TRIGger:A:VIDeo:CUSTom:FORMat command.

Description
  • This command sets the video trigger format (either interlaced or progressive) to use for triggering on video signals. To use this command, you must also set the video standard to BILevelcustom or TRILevelcustom (using TRIGGER:A:VIDEO:STANDARD).
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:CUSTom:FORMat? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:CUSTom:FORMat? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:CUSTom:FORMat value command.
SCPI Syntax
- TRIGger:A:VIDeo:CUSTom:FORMat {INTERLAced|PROGressive}
- TRIGger:A:VIDeo:CUSTom:FORMat?
Info
  • INTERLAced argument sets the format to interlaced video lines.
  • PROGressive argument sets the format to progressive video lines.

lineperiod property

Return the TRIGger:A:VIDeo:CUSTom:LINEPeriod command.

Description
  • This command sets the line period for the standard under test. To use this command, you must also set the video standard to BILevelcustom or TRILevelcustom (using TRIGGER:A:VIDEO:STANDARD).
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:CUSTom:LINEPeriod? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:CUSTom:LINEPeriod? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:CUSTom:LINEPeriod value command.
SCPI Syntax
- TRIGger:A:VIDeo:CUSTom:LINEPeriod <NR3>
- TRIGger:A:VIDeo:CUSTom:LINEPeriod?
Info
  • <NR3> is the custom video line period.

syncinterval property

Return the TRIGger:A:VIDeo:CUSTom:SYNCInterval command.

Description
  • This command sets the sync interval for the standard under test to use for triggering on video signals. This is only required for BiLevel Custom. To use this command, you must also set the video standard to BILevelcustom (using TRIGGER:A:VIDEO:STANDARD).
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:CUSTom:SYNCInterval? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:CUSTom:SYNCInterval? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:CUSTom:SYNCInterval value command.
SCPI Syntax
- TRIGger:A:VIDeo:CUSTom:SYNCInterval <NR3>
- TRIGger:A:VIDeo:CUSTom:SYNCInterval?
Info
  • <NR3> is the sync interval.

type property

Return the TRIGger:A:VIDeo:CUSTom:TYPe command.

Description
  • This command sets the video trigger format (either interlaced or progressive) to use for triggering on video signals. To use this command, you must also set the video standard to BILevelcustom or TRILevelcustom (using TRIGGER:A:VIDEO:STANDARD).
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:CUSTom:TYPe? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:CUSTom:TYPe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:CUSTom:TYPe value command.
SCPI Syntax
- TRIGger:A:VIDeo:CUSTom:TYPe {INTERLAced|PROGressive}
- TRIGger:A:VIDeo:CUSTom:TYPe?
Info
  • INTERLAced argument sets the format to interlaced video lines.
  • PROGressive argument sets the format to progressive video lines.

TriggerAVideoCustomFormat

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:VIDeo:CUSTom:FORMat command.

Description
  • This command sets the video trigger format (either interlaced or progressive) to use for triggering on video signals. To use this command, you must also set the video standard to BILevelcustom or TRILevelcustom (using TRIGGER:A:VIDEO:STANDARD).
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:CUSTom:FORMat? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:CUSTom:FORMat? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:CUSTom:FORMat value command.
SCPI Syntax
- TRIGger:A:VIDeo:CUSTom:FORMat {INTERLAced|PROGressive}
- TRIGger:A:VIDeo:CUSTom:FORMat?
Info
  • INTERLAced argument sets the format to interlaced video lines.
  • PROGressive argument sets the format to progressive video lines.

TriggerAVideoCustomLineperiod

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:VIDeo:CUSTom:LINEPeriod command.

Description
  • This command sets the line period for the standard under test. To use this command, you must also set the video standard to BILevelcustom or TRILevelcustom (using TRIGGER:A:VIDEO:STANDARD).
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:CUSTom:LINEPeriod? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:CUSTom:LINEPeriod? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:CUSTom:LINEPeriod value command.
SCPI Syntax
- TRIGger:A:VIDeo:CUSTom:LINEPeriod <NR3>
- TRIGger:A:VIDeo:CUSTom:LINEPeriod?
Info
  • <NR3> is the custom video line period.

TriggerAVideoCustomSyncinterval

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:VIDeo:CUSTom:SYNCInterval command.

Description
  • This command sets the sync interval for the standard under test to use for triggering on video signals. This is only required for BiLevel Custom. To use this command, you must also set the video standard to BILevelcustom (using TRIGGER:A:VIDEO:STANDARD).
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:CUSTom:SYNCInterval? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:CUSTom:SYNCInterval? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:CUSTom:SYNCInterval value command.
SCPI Syntax
- TRIGger:A:VIDeo:CUSTom:SYNCInterval <NR3>
- TRIGger:A:VIDeo:CUSTom:SYNCInterval?
Info
  • <NR3> is the sync interval.

TriggerAVideoCustomType

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:VIDeo:CUSTom:TYPe command.

Description
  • This command sets the video trigger format (either interlaced or progressive) to use for triggering on video signals. To use this command, you must also set the video standard to BILevelcustom or TRILevelcustom (using TRIGGER:A:VIDEO:STANDARD).
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:CUSTom:TYPe? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:CUSTom:TYPe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:CUSTom:TYPe value command.
SCPI Syntax
- TRIGger:A:VIDeo:CUSTom:TYPe {INTERLAced|PROGressive}
- TRIGger:A:VIDeo:CUSTom:TYPe?
Info
  • INTERLAced argument sets the format to interlaced video lines.
  • PROGressive argument sets the format to progressive video lines.

TriggerAVideoField

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:VIDeo:FIELD command.

Description
  • This command sets the video field to use for triggering on video signals (odd fields, even fields, all fields, all lines, numeric).
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:FIELD? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:FIELD? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:FIELD value command.
SCPI Syntax
- TRIGger:A:VIDeo:FIELD {ODD|EVEN|ALLFields|ALLLines|NUMERic}
- TRIGger:A:VIDeo:FIELD?
Info
  • ODD argument sets the oscilloscope to trigger on interlaced video odd fields.
  • EVEN argument sets the oscilloscope to trigger on interlaced video even fields.
  • ALLFields argument sets the oscilloscope to trigger on all fields.
  • ALLLines argument sets the oscilloscope to trigger on all video lines.
  • NUMERic argument sets the oscilloscope to trigger on the video signal line specified by the TRIGGER:A:VIDEO:LINE command.

TriggerAVideoHoldoff

Bases: SCPICmdRead

The TRIGger:A:VIDeo:HOLDoff command tree.

Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:HOLDoff? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:HOLDoff? query and raise an AssertionError if the returned value does not match value.
Properties
  • .field: The TRIGger:A:VIDeo:HOLDoff:FIELD command.

field property

Return the TRIGger:A:VIDeo:HOLDoff:FIELD command.

Description
  • This command sets the video trigger holdoff, in terms of video fields, to use for triggering on video signals.
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:HOLDoff:FIELD? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:HOLDoff:FIELD? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:HOLDoff:FIELD value command.
SCPI Syntax
- TRIGger:A:VIDeo:HOLDoff:FIELD <NR3>
- TRIGger:A:VIDeo:HOLDoff:FIELD?
Info
  • <NR3> argument is a real number from 0.0 to 8.5 in increments of 0.5. The argument sets the number of fields that the oscilloscope waits before rearming the video trigger.

TriggerAVideoHoldoffField

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:VIDeo:HOLDoff:FIELD command.

Description
  • This command sets the video trigger holdoff, in terms of video fields, to use for triggering on video signals.
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:HOLDoff:FIELD? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:HOLDoff:FIELD? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:HOLDoff:FIELD value command.
SCPI Syntax
- TRIGger:A:VIDeo:HOLDoff:FIELD <NR3>
- TRIGger:A:VIDeo:HOLDoff:FIELD?
Info
  • <NR3> argument is a real number from 0.0 to 8.5 in increments of 0.5. The argument sets the number of fields that the oscilloscope waits before rearming the video trigger.

TriggerAVideoLine

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:VIDeo:LINE command.

Description
  • This command lets you set the specific video line number to be used for triggering on a video signal. You must also use the command to specify NUMERic as the video field to use.
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:LINE? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:LINE? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:LINE value command.
SCPI Syntax
- TRIGger:A:VIDeo:LINE <NR1>
- TRIGger:A:VIDeo:LINE?
Info
  • <NR1> argument is an integer that sets the video line number on which the oscilloscope triggers. The following table lists the valid choices, depending on the active video standard.

TriggerAVideoPolarity

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:VIDeo:POLarity command.

Description
  • This command sets the polarity to use for triggering on video signals.
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:POLarity? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:POLarity? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:POLarity value command.
SCPI Syntax
- TRIGger:A:VIDeo:POLarity {NEGative|POSitive}
- TRIGger:A:VIDeo:POLarity?
Info
  • POSitive argument sets the oscilloscope to trigger on a positive video sync pulse.
  • NEGative argument sets the oscilloscope to trigger on a negative video sync pulse.

TriggerAVideoSource

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:VIDeo:SOUrce command.

Description
  • This command sets the source channel to use for triggering on video signals (CH1-4).
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:SOUrce value command.
SCPI Syntax
- TRIGger:A:VIDeo:SOUrce {CH<x>}
- TRIGger:A:VIDeo:SOUrce?
Info
  • CH<x> specifies the input channel to use as the A video trigger. x has a minimum of 1 and a maximum of 4.

TriggerAVideoStandard

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:VIDeo:STANdard command.

Description
  • This command sets the standard to use for triggering on video signals.
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:STANdard? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:STANdard? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:STANdard value command.
SCPI Syntax
- TRIGger:A:VIDeo:STANdard {NTSc|PAL|SECAM|BILevelcustom|TRILevelcustom|HD480P60|HD576P50|HD720P30|HD720P50|HD720P60|HD875I60|HD1080P24|HD1080SF24|HD1080I50|HD1080I60|HD1080P25|HD1080P30|HD1080P50|HD1080P60}
- TRIGger:A:VIDeo:STANdard?
Info
  • NTSc sets the oscilloscope to trigger on video signals that meet the NTSC 525/60/2:1 standard (a line rate of 525 lines per frame and a field rate of 60 Hz).
  • PAL sets the oscilloscope to trigger on video signals that meet the NTSC 625/50/2:1 standard (a line rate of 625 lines per frame and a field rate of 50 Hz).
  • SECAM sets the oscilloscope to trigger on video signals that meet the SECAM standard.
  • BILevelcustom sets the oscilloscope to trigger on video horizontal scan rate parameters defined by the.
  • TRILevelcustom sets the oscilloscope to trigger on video horizontal scan rate parameters defined by the.
  • HD480P60 set the oscilloscope to trigger on an HDTV video signal that meets standards defined in the following table.
  • HD576P50 set the oscilloscope to trigger on an HDTV video signal that meets standards defined in the following table.
  • HD720P30 set the oscilloscope to trigger on an HDTV video signal that meets standards defined in the following table.
  • HD720P50 set the oscilloscope to trigger on an HDTV video signal that meets standards defined in the following table.
  • HD720P60 set the oscilloscope to trigger on an HDTV video signal that meets standards defined in the following table.
  • HD875I60 set the oscilloscope to trigger on an HDTV video signal that meets standards defined in the following table.
  • HD1080P24 set the oscilloscope to trigger on an HDTV video signal that meets standards defined in the following table.
  • HD1080SF24 set the oscilloscope to trigger on an HDTV video signal that meets standards defined in the following table.
  • HD1080I50 set the oscilloscope to trigger on an HDTV video signal that meets standards defined in the following table.
  • HD1080I60 set the oscilloscope to trigger on an HDTV video signal that meets standards defined in the following table.
  • HD1080P25 set the oscilloscope to trigger on an HDTV video signal that meets standards defined in the following table.
  • HD1080P30 set the oscilloscope to trigger on an HDTV video signal that meets standards defined in the following table.
  • HD1080P50 set the oscilloscope to trigger on an HDTV video signal that meets standards defined in the following table.
  • HD1080P60 set the oscilloscope to trigger on an HDTV video signal that meets standards defined in the following table.

TriggerAVideoSync

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:VIDeo:SYNC command.

Description
  • This command sets the video field to use for triggering on video signals (odd fields, even fields, all fields, all lines, numeric).
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:SYNC? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:SYNC? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:SYNC value command.
SCPI Syntax
- TRIGger:A:VIDeo:SYNC {ODD|EVEN|ALLFields|ALLLines|NUMERic}
- TRIGger:A:VIDeo:SYNC?
Info
  • ODD argument sets the oscilloscope to trigger on interlaced video odd fields.
  • EVEN argument sets the oscilloscope to trigger on interlaced video even fields.
  • ALLFields argument sets the oscilloscope to trigger on all fields.
  • ALLLines argument sets the oscilloscope to trigger on all video lines.
  • NUMERic argument sets the oscilloscope to trigger on the video signal line specified by the TRIGGER:A:VIDEO:LINE command.

TriggerB

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:B command.

Description
  • Sets the B trigger level to 50% of minimum and maximum. The query form of this command returns the B trigger parameters. This command is similar to selecting B Event (Delayed) Trigger Setup from the Trigger menu and then viewing the current setups.
Usage
  • Using the .query() method will send the TRIGger:B? query.
  • Using the .verify(value) method will send the TRIGger:B? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:B value command.
SCPI Syntax
- TRIGger:B SETLevel
- TRIGger:B?
Info
  • SETLevel sets the B trigger level to 50% of MIN and MAX.
Properties
  • .by: The TRIGger:B:BY command.
  • .edge: The TRIGger:B:EDGE command.
  • .events: The TRIGger:B:EVENTS command.
  • .level: The TRIGger:B:LEVel command.
  • .lowerthreshold: The TRIGger:B:LOWerthreshold command tree.
  • .state: The TRIGger:B:STATE command.
  • .time: The TRIGger:B:TIMe command.
  • .type: The TRIGger:B:TYPe command.

by property

Return the TRIGger:B:BY command.

Description
  • Selects or returns whether the B trigger occurs after a specified number of events or a specified period of time after the A trigger.
Usage
  • Using the .query() method will send the TRIGger:B:BY? query.
  • Using the .verify(value) method will send the TRIGger:B:BY? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:B:BY value command.
SCPI Syntax
- TRIGger:B:BY {EVENTS|TIMe}
- TRIGger:B:BY?
Info
  • EVENTS sets the B trigger to take place following a set number of trigger events after the A trigger occurs. The number of events is specified by TRIGger:B:EVENTS:COUNt.
  • TIMe sets the B trigger to occur a set time after the A trigger event. The time period is specified by TRIGger:B:TIMe.

edge property

Return the TRIGger:B:EDGE command.

Description
  • Returns the source, slope, and coupling for B trigger.
Usage
  • Using the .query() method will send the TRIGger:B:EDGE? query.
  • Using the .verify(value) method will send the TRIGger:B:EDGE? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:B:EDGE?
Sub-properties
  • .coupling: The TRIGger:B:EDGE:COUPling command.
  • .slope: The TRIGger:B:EDGE:SLOpe command.
  • .source: The TRIGger:B:EDGE:SOUrce command.

events property

Return the TRIGger:B:EVENTS command.

Description
  • Returns the current B trigger events parameter.
Usage
  • Using the .query() method will send the TRIGger:B:EVENTS? query.
  • Using the .verify(value) method will send the TRIGger:B:EVENTS? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:B:EVENTS?
Sub-properties
  • .count: The TRIGger:B:EVENTS:COUNt command.

level property

Return the TRIGger:B:LEVel command.

Description
  • This command specifies the level for the B trigger.
Usage
  • Using the .query() method will send the TRIGger:B:LEVel? query.
  • Using the .verify(value) method will send the TRIGger:B:LEVel? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:B:LEVel value command.
SCPI Syntax
- TRIGger:B:LEVel {TTL|<NR3>}
- TRIGger:B:LEVel?
Info
  • TTL specifies a preset TTL high level of 1.4 V.
  • <NR3> is a floating point number that specifies the B trigger level, in volts.
Sub-properties
  • .ch: The TRIGger:B:LEVel:CH<x> command.
  • .d: The TRIGger:B:LEVel:D<x> command.

lowerthreshold property

lowerthreshold: TriggerBLowerthreshold

Return the TRIGger:B:LOWerthreshold command tree.

Usage
  • Using the .query() method will send the TRIGger:B:LOWerthreshold? query.
  • Using the .verify(value) method will send the TRIGger:B:LOWerthreshold? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .ch: The TRIGger:B:LOWerthreshold:CH<x> command.
  • .d: The TRIGger:B:LOWerthreshold:D<x> command.

state property

Return the TRIGger:B:STATE command.

Description
  • This command specifies the state of B trigger activity. If the B trigger state is on, the B trigger is part of the triggering sequence. If the B trigger state is off, then only the A trigger causes the trigger event.
Usage
  • Using the .query() method will send the TRIGger:B:STATE? query.
  • Using the .verify(value) method will send the TRIGger:B:STATE? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:B:STATE value command.
SCPI Syntax
- TRIGger:B:STATE {ON|OFF|<NR1>}
- TRIGger:B:STATE?
Info
  • ON specifies that the B trigger is active and in causes trigger events conjunction with the A trigger.
  • OFF specifies that only the A trigger causes trigger events.
  • <NR1> a 0 turns off the B trigger; any other value activates the B trigger.

time property

Return the TRIGger:B:TIMe command.

Description
  • This command specifies B trigger delay time. The B Trigger time applies only if TRIGger:B:BY is set to TIMe.
Usage
  • Using the .query() method will send the TRIGger:B:TIMe? query.
  • Using the .verify(value) method will send the TRIGger:B:TIMe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:B:TIMe value command.
SCPI Syntax
- TRIGger:B:TIMe <NR3>
- TRIGger:B:TIMe?
Info
  • <NR3> is a floating point number that specifies the B trigger delay time in seconds.

type property

Return the TRIGger:B:TYPe command.

Description
  • This command specifies the type of B trigger. The only supported B trigger type is EDGE.
Usage
  • Using the .query() method will send the TRIGger:B:TYPe? query.
  • Using the .verify(value) method will send the TRIGger:B:TYPe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:B:TYPe value command.
SCPI Syntax
- TRIGger:B:TYPe EDGE
- TRIGger:B:TYPe?
Info
  • EDGE sets the B trigger type to edge.

TriggerBBy

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:B:BY command.

Description
  • Selects or returns whether the B trigger occurs after a specified number of events or a specified period of time after the A trigger.
Usage
  • Using the .query() method will send the TRIGger:B:BY? query.
  • Using the .verify(value) method will send the TRIGger:B:BY? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:B:BY value command.
SCPI Syntax
- TRIGger:B:BY {EVENTS|TIMe}
- TRIGger:B:BY?
Info
  • EVENTS sets the B trigger to take place following a set number of trigger events after the A trigger occurs. The number of events is specified by TRIGger:B:EVENTS:COUNt.
  • TIMe sets the B trigger to occur a set time after the A trigger event. The time period is specified by TRIGger:B:TIMe.

TriggerBEdge

Bases: SCPICmdRead

The TRIGger:B:EDGE command.

Description
  • Returns the source, slope, and coupling for B trigger.
Usage
  • Using the .query() method will send the TRIGger:B:EDGE? query.
  • Using the .verify(value) method will send the TRIGger:B:EDGE? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:B:EDGE?
Properties
  • .coupling: The TRIGger:B:EDGE:COUPling command.
  • .slope: The TRIGger:B:EDGE:SLOpe command.
  • .source: The TRIGger:B:EDGE:SOUrce command.

coupling property

Return the TRIGger:B:EDGE:COUPling command.

Description
  • This command specifies the type of coupling for the B edge trigger.
Usage
  • Using the .query() method will send the TRIGger:B:EDGE:COUPling? query.
  • Using the .verify(value) method will send the TRIGger:B:EDGE:COUPling? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:B:EDGE:COUPling value command.
SCPI Syntax
- TRIGger:B:EDGE:COUPling {DC|HFRej|LFRej|NOISErej}
- TRIGger:B:EDGE:COUPling?
Info
  • DC selects DC trigger coupling.
  • HFRej selects high-frequency reject coupling.
  • LFRej selects low-frequency reject coupling.
  • NOISErej selects DC low sensitivity.

slope property

Return the TRIGger:B:EDGE:SLOpe command.

Description
  • This command specifies the slope for the B trigger.
Usage
  • Using the .query() method will send the TRIGger:B:EDGE:SLOpe? query.
  • Using the .verify(value) method will send the TRIGger:B:EDGE:SLOpe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:B:EDGE:SLOpe value command.
SCPI Syntax
- TRIGger:B:EDGE:SLOpe {RISe|FALL}
- TRIGger:B:EDGE:SLOpe?
Info
  • RISe triggers on the rising or positive edge of a signal.
  • FALL triggers on the falling or negative edge of a signal.

source property

Return the TRIGger:B:EDGE:SOUrce command.

Description
  • This command specifies the source for the B trigger.
Usage
  • Using the .query() method will send the TRIGger:B:EDGE:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:B:EDGE:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:B:EDGE:SOUrce value command.
SCPI Syntax
- TRIGger:B:EDGE:SOUrce {CH<x>|AUX|LINE|RF}
- TRIGger:B:EDGE:SOUrce?
Info
  • CH<x> specifies an analog channel as the B trigger source.
  • AUX specifies an external trigger using the Aux In connector located on the front panel of the oscilloscope as the B trigger source. (For 2-channel MDO32 model only.).
  • LINE specifies the AC power line as the B trigger source.

TriggerBEdgeCoupling

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:B:EDGE:COUPling command.

Description
  • This command specifies the type of coupling for the B edge trigger.
Usage
  • Using the .query() method will send the TRIGger:B:EDGE:COUPling? query.
  • Using the .verify(value) method will send the TRIGger:B:EDGE:COUPling? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:B:EDGE:COUPling value command.
SCPI Syntax
- TRIGger:B:EDGE:COUPling {DC|HFRej|LFRej|NOISErej}
- TRIGger:B:EDGE:COUPling?
Info
  • DC selects DC trigger coupling.
  • HFRej selects high-frequency reject coupling.
  • LFRej selects low-frequency reject coupling.
  • NOISErej selects DC low sensitivity.

TriggerBEdgeSlope

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:B:EDGE:SLOpe command.

Description
  • This command specifies the slope for the B trigger.
Usage
  • Using the .query() method will send the TRIGger:B:EDGE:SLOpe? query.
  • Using the .verify(value) method will send the TRIGger:B:EDGE:SLOpe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:B:EDGE:SLOpe value command.
SCPI Syntax
- TRIGger:B:EDGE:SLOpe {RISe|FALL}
- TRIGger:B:EDGE:SLOpe?
Info
  • RISe triggers on the rising or positive edge of a signal.
  • FALL triggers on the falling or negative edge of a signal.

TriggerBEdgeSource

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:B:EDGE:SOUrce command.

Description
  • This command specifies the source for the B trigger.
Usage
  • Using the .query() method will send the TRIGger:B:EDGE:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:B:EDGE:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:B:EDGE:SOUrce value command.
SCPI Syntax
- TRIGger:B:EDGE:SOUrce {CH<x>|AUX|LINE|RF}
- TRIGger:B:EDGE:SOUrce?
Info
  • CH<x> specifies an analog channel as the B trigger source.
  • AUX specifies an external trigger using the Aux In connector located on the front panel of the oscilloscope as the B trigger source. (For 2-channel MDO32 model only.).
  • LINE specifies the AC power line as the B trigger source.

TriggerBEvents

Bases: SCPICmdRead

The TRIGger:B:EVENTS command.

Description
  • Returns the current B trigger events parameter.
Usage
  • Using the .query() method will send the TRIGger:B:EVENTS? query.
  • Using the .verify(value) method will send the TRIGger:B:EVENTS? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:B:EVENTS?
Properties
  • .count: The TRIGger:B:EVENTS:COUNt command.

count property

Return the TRIGger:B:EVENTS:COUNt command.

Description
  • This command specifies the number of events that must occur before the B trigger (when TRIG:DELay:BY is set to EVENTS).
Usage
  • Using the .query() method will send the TRIGger:B:EVENTS:COUNt? query.
  • Using the .verify(value) method will send the TRIGger:B:EVENTS:COUNt? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:B:EVENTS:COUNt value command.
SCPI Syntax
- TRIGger:B:EVENTS:COUNt <NR1>
- TRIGger:B:EVENTS:COUNt?
Info
  • <NR1> is the number of B trigger events, which can range from 1 to 10,000,000.

TriggerBEventsCount

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:B:EVENTS:COUNt command.

Description
  • This command specifies the number of events that must occur before the B trigger (when TRIG:DELay:BY is set to EVENTS).
Usage
  • Using the .query() method will send the TRIGger:B:EVENTS:COUNt? query.
  • Using the .verify(value) method will send the TRIGger:B:EVENTS:COUNt? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:B:EVENTS:COUNt value command.
SCPI Syntax
- TRIGger:B:EVENTS:COUNt <NR1>
- TRIGger:B:EVENTS:COUNt?
Info
  • <NR1> is the number of B trigger events, which can range from 1 to 10,000,000.

TriggerBLevel

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:B:LEVel command.

Description
  • This command specifies the level for the B trigger.
Usage
  • Using the .query() method will send the TRIGger:B:LEVel? query.
  • Using the .verify(value) method will send the TRIGger:B:LEVel? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:B:LEVel value command.
SCPI Syntax
- TRIGger:B:LEVel {TTL|<NR3>}
- TRIGger:B:LEVel?
Info
  • TTL specifies a preset TTL high level of 1.4 V.
  • <NR3> is a floating point number that specifies the B trigger level, in volts.
Properties
  • .ch: The TRIGger:B:LEVel:CH<x> command.
  • .d: The TRIGger:B:LEVel:D<x> command.

ch property

Return the TRIGger:B:LEVel:CH<x> command.

Description
  • This command specifies the B trigger level for channel , where x is the channel number. Each Channel can have an independent Level.
Usage
  • Using the .query() method will send the TRIGger:B:LEVel:CH<x>? query.
  • Using the .verify(value) method will send the TRIGger:B:LEVel:CH<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:B:LEVel:CH<x> value command.
SCPI Syntax
- TRIGger:B:LEVel:CH<x> {ECL|TTL|<NR3>}
- TRIGger:B:LEVel:CH<x>?
Info
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.
  • <NR3> is a floating point number that specifies the trigger level in user units (usually volts).

d property

Return the TRIGger:B:LEVel:D<x> command.

Description
  • This command specifies the B trigger level for digital channel , where x is the channel number. Each channel can have an independent level.
Usage
  • Using the .query() method will send the TRIGger:B:LEVel:D<x>? query.
  • Using the .verify(value) method will send the TRIGger:B:LEVel:D<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:B:LEVel:D<x> value command.
SCPI Syntax
- TRIGger:B:LEVel:D<x> {ECL|TTL|<NR3>}
- TRIGger:B:LEVel:D<x>?
Info
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.
  • <NR3> is a floating point number that specifies the trigger level in user units (usually volts).

TriggerBLevelChannel

Bases: ValidatedChannel, SCPICmdWrite, SCPICmdRead

The TRIGger:B:LEVel:CH<x> command.

Description
  • This command specifies the B trigger level for channel , where x is the channel number. Each Channel can have an independent Level.
Usage
  • Using the .query() method will send the TRIGger:B:LEVel:CH<x>? query.
  • Using the .verify(value) method will send the TRIGger:B:LEVel:CH<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:B:LEVel:CH<x> value command.
SCPI Syntax
- TRIGger:B:LEVel:CH<x> {ECL|TTL|<NR3>}
- TRIGger:B:LEVel:CH<x>?
Info
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.
  • <NR3> is a floating point number that specifies the trigger level in user units (usually volts).

TriggerBLevelDigitalBit

Bases: ValidatedDigitalBit, SCPICmdWrite, SCPICmdRead

The TRIGger:B:LEVel:D<x> command.

Description
  • This command specifies the B trigger level for digital channel , where x is the channel number. Each channel can have an independent level.
Usage
  • Using the .query() method will send the TRIGger:B:LEVel:D<x>? query.
  • Using the .verify(value) method will send the TRIGger:B:LEVel:D<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:B:LEVel:D<x> value command.
SCPI Syntax
- TRIGger:B:LEVel:D<x> {ECL|TTL|<NR3>}
- TRIGger:B:LEVel:D<x>?
Info
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.
  • <NR3> is a floating point number that specifies the trigger level in user units (usually volts).

TriggerBLowerthreshold

Bases: SCPICmdRead

The TRIGger:B:LOWerthreshold command tree.

Usage
  • Using the .query() method will send the TRIGger:B:LOWerthreshold? query.
  • Using the .verify(value) method will send the TRIGger:B:LOWerthreshold? query and raise an AssertionError if the returned value does not match value.
Properties
  • .ch: The TRIGger:B:LOWerthreshold:CH<x> command.
  • .d: The TRIGger:B:LOWerthreshold:D<x> command.

ch property

Return the TRIGger:B:LOWerthreshold:CH<x> command.

Description
  • This command specifies the B trigger lower threshold for the channel , where x is the channel number. Each channel can have an independent level. Used in runt and transition triggers as the lower threshold. Used for all other trigger types as the single level/threshold.
Usage
  • Using the .query() method will send the TRIGger:B:LOWerthreshold:CH<x>? query.
  • Using the .verify(value) method will send the TRIGger:B:LOWerthreshold:CH<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:B:LOWerthreshold:CH<x> value command.
SCPI Syntax
- TRIGger:B:LOWerthreshold:CH<x> {ECL|TTL|<NR3>}
- TRIGger:B:LOWerthreshold:CH<x>?
Info
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.
  • <NR3> is a floating point number that specifies the threshold level, in volts.

d property

Return the TRIGger:B:LOWerthreshold:D<x> command.

Description
  • Sets or queries the lower threshold for the digital channel selected. Each channel can have an independent level. Used in runt and transition triggers as the lower threshold. Used for all other trigger types as the single level/threshold.
Usage
  • Using the .query() method will send the TRIGger:B:LOWerthreshold:D<x>? query.
  • Using the .verify(value) method will send the TRIGger:B:LOWerthreshold:D<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:B:LOWerthreshold:D<x> value command.
SCPI Syntax
- TRIGger:B:LOWerthreshold:D<x> {<NR3>|ECL|TTL}
- TRIGger:B:LOWerthreshold:D<x>?
Info
  • <NR3> is a floating point number that specifies the threshold in volts.
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.

TriggerBLowerthresholdChannel

Bases: ValidatedChannel, SCPICmdWrite, SCPICmdRead

The TRIGger:B:LOWerthreshold:CH<x> command.

Description
  • This command specifies the B trigger lower threshold for the channel , where x is the channel number. Each channel can have an independent level. Used in runt and transition triggers as the lower threshold. Used for all other trigger types as the single level/threshold.
Usage
  • Using the .query() method will send the TRIGger:B:LOWerthreshold:CH<x>? query.
  • Using the .verify(value) method will send the TRIGger:B:LOWerthreshold:CH<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:B:LOWerthreshold:CH<x> value command.
SCPI Syntax
- TRIGger:B:LOWerthreshold:CH<x> {ECL|TTL|<NR3>}
- TRIGger:B:LOWerthreshold:CH<x>?
Info
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.
  • <NR3> is a floating point number that specifies the threshold level, in volts.

TriggerBLowerthresholdDigitalBit

Bases: ValidatedDigitalBit, SCPICmdWrite, SCPICmdRead

The TRIGger:B:LOWerthreshold:D<x> command.

Description
  • Sets or queries the lower threshold for the digital channel selected. Each channel can have an independent level. Used in runt and transition triggers as the lower threshold. Used for all other trigger types as the single level/threshold.
Usage
  • Using the .query() method will send the TRIGger:B:LOWerthreshold:D<x>? query.
  • Using the .verify(value) method will send the TRIGger:B:LOWerthreshold:D<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:B:LOWerthreshold:D<x> value command.
SCPI Syntax
- TRIGger:B:LOWerthreshold:D<x> {<NR3>|ECL|TTL}
- TRIGger:B:LOWerthreshold:D<x>?
Info
  • <NR3> is a floating point number that specifies the threshold in volts.
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.

TriggerBState

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:B:STATE command.

Description
  • This command specifies the state of B trigger activity. If the B trigger state is on, the B trigger is part of the triggering sequence. If the B trigger state is off, then only the A trigger causes the trigger event.
Usage
  • Using the .query() method will send the TRIGger:B:STATE? query.
  • Using the .verify(value) method will send the TRIGger:B:STATE? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:B:STATE value command.
SCPI Syntax
- TRIGger:B:STATE {ON|OFF|<NR1>}
- TRIGger:B:STATE?
Info
  • ON specifies that the B trigger is active and in causes trigger events conjunction with the A trigger.
  • OFF specifies that only the A trigger causes trigger events.
  • <NR1> a 0 turns off the B trigger; any other value activates the B trigger.

TriggerBTime

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:B:TIMe command.

Description
  • This command specifies B trigger delay time. The B Trigger time applies only if TRIGger:B:BY is set to TIMe.
Usage
  • Using the .query() method will send the TRIGger:B:TIMe? query.
  • Using the .verify(value) method will send the TRIGger:B:TIMe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:B:TIMe value command.
SCPI Syntax
- TRIGger:B:TIMe <NR3>
- TRIGger:B:TIMe?
Info
  • <NR3> is a floating point number that specifies the B trigger delay time in seconds.

TriggerBType

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:B:TYPe command.

Description
  • This command specifies the type of B trigger. The only supported B trigger type is EDGE.
Usage
  • Using the .query() method will send the TRIGger:B:TYPe? query.
  • Using the .verify(value) method will send the TRIGger:B:TYPe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:B:TYPe value command.
SCPI Syntax
- TRIGger:B:TYPe EDGE
- TRIGger:B:TYPe?
Info
  • EDGE sets the B trigger type to edge.

TriggerExternal

Bases: SCPICmdRead

The TRIGger:EXTernal command.

Description
  • Returns all external trigger-related parameters for the probe attached to the Aux Input connector.
Usage
  • Using the .query() method will send the TRIGger:EXTernal? query.
  • Using the .verify(value) method will send the TRIGger:EXTernal? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:EXTernal?
Properties
  • .probe: The TRIGger:EXTernal:PRObe command.
  • .yunits: The TRIGger:EXTernal:YUNIts command.

probe property

Return the TRIGger:EXTernal:PRObe command.

Description
  • This command specifies the attenuation factor value of the probe attached to the Aux Input connector.
Usage
  • Using the .query() method will send the TRIGger:EXTernal:PRObe? query.
  • Using the .verify(value) method will send the TRIGger:EXTernal:PRObe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:EXTernal:PRObe value command.
SCPI Syntax
- TRIGger:EXTernal:PRObe <NR3>
- TRIGger:EXTernal:PRObe?
Info
  • <NR3> is a floating point number that specifies the attenuation factor of the probe.

yunits property

Return the TRIGger:EXTernal:YUNIts command.

Description
  • Returns the vertical (Y) units of the probe attached to the Aux In connector.
Usage
  • Using the .query() method will send the TRIGger:EXTernal:YUNIts? query.
  • Using the .verify(value) method will send the TRIGger:EXTernal:YUNIts? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:EXTernal:YUNIts?

TriggerExternalProbe

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:EXTernal:PRObe command.

Description
  • This command specifies the attenuation factor value of the probe attached to the Aux Input connector.
Usage
  • Using the .query() method will send the TRIGger:EXTernal:PRObe? query.
  • Using the .verify(value) method will send the TRIGger:EXTernal:PRObe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:EXTernal:PRObe value command.
SCPI Syntax
- TRIGger:EXTernal:PRObe <NR3>
- TRIGger:EXTernal:PRObe?
Info
  • <NR3> is a floating point number that specifies the attenuation factor of the probe.

TriggerExternalYunits

Bases: SCPICmdRead

The TRIGger:EXTernal:YUNIts command.

Description
  • Returns the vertical (Y) units of the probe attached to the Aux In connector.
Usage
  • Using the .query() method will send the TRIGger:EXTernal:YUNIts? query.
  • Using the .verify(value) method will send the TRIGger:EXTernal:YUNIts? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:EXTernal:YUNIts?

TriggerFrequency

Bases: SCPICmdRead

The TRIGger:FREQuency command.

Description
  • Returns the trigger frequency in hertz if available. If the trigger frequency is not currently available, the IEEE Not A Number (NaN = 99.10E+36) value is returned. The maximum precision of the returned frequency is 12 digits. Use the DISPLAY:TRIGFREQUENCY command to enable/disable the calculation of the trigger frequency.
Usage
  • Using the .query() method will send the TRIGger:FREQuency? query.
  • Using the .verify(value) method will send the TRIGger:FREQuency? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:FREQuency?

TriggerState

Bases: SCPICmdRead

The TRIGger:STATE command.

Description
  • This query-only command returns the current state of the triggering system.
Usage
  • Using the .query() method will send the TRIGger:STATE? query.
  • Using the .verify(value) method will send the TRIGger:STATE? query and raise an AssertionError if the returned value does not match value.