auxin
¶
The auxin commands module.
These commands are used in the following models: DPO5K, DPO5KB, DPO70KC, DPO70KD, DPO70KDX, DPO70KSX, DPO7K, DPO7KC, DSA70KC, DSA70KD, MSO5K, MSO5KB, MSO70KC, MSO70KDX
THIS FILE IS AUTO-GENERATED, IT SHOULD NOT BE MANUALLY MODIFIED.
Please report an issue if one is found.
Commands and Queries
- AUXIn:BANdwidth <NR3>
- AUXIn:BANdwidth?
- AUXIn:COUPling <NR3>
- AUXIn:COUPling?
- AUXIn:OFFSet <NR3>
- AUXIn:OFFSet?
- AUXIn:PROBEFunc:EXTAtten <NR3>
- AUXIn:PROBEFunc:EXTAtten?
- AUXIn:PROBEFunc:EXTDBatten <NR3>
- AUXIn:PROBEFunc:EXTDBatten?
- AUXIn:PROBEFunc:EXTUnits <QString>
- AUXIn:PROBEFunc:EXTUnits?
- AUXIn:PRObe:AUTOZero EXECute
- AUXIn:PRObe:DEGAUSS EXECute
- AUXIn:PRObe:DEGAUSS:STATE?
- AUXIn:PRObe:FORCEDRange <NR3>
- AUXIn:PRObe:FORCEDRange?
- AUXIn:PRObe:GAIN?
- AUXIn:PRObe:ID:SERnumber?
- AUXIn:PRObe:ID:TYPe?
- AUXIn:PRObe:INPUTMode {COMmonmode|DEFault|DIFFerential|A|B}
- AUXIn:PRObe:INPUTMode:AOFFSet <NR3>
- AUXIn:PRObe:INPUTMode:AOFFSet?
- AUXIn:PRObe:INPUTMode:BOFFSet <NR3>
- AUXIn:PRObe:INPUTMode:BOFFSet?
- AUXIn:PRObe:INPUTMode:CMOFFSet <NR3>
- AUXIn:PRObe:INPUTMode:CMOFFSet?
- AUXIn:PRObe:INPUTMode:DMOFFSet <NR3>
- AUXIn:PRObe:INPUTMode:DMOFFSet?
- AUXIn:PRObe:INPUTMode?
- AUXIn:PRObe:RANge {ATTEN1X|ATTEN1_25X|ATTEN1_5X|ATTEN1_75X|ATTEN2X|ATTEN2_5X|ATTEN3X|ATTEN3_5X|ATTEN4X|ATTEN4_5X|ATTEN5X|ATTEN5_5X|ATTEN6X|ATTEN6_5X|ATTEN7X|ATTEN7_5X|ATTEN8X|ATTEN8_5X|ATTEN9X|ATTEN9_5X|ATTEN10X|ATTEN12_5X|ATTEN15X|ATTEN17_5X|ATTEN20X|ATTEN25X|ATTEN30X|ATTEN35X|ATTEN40X|ATTEN45X|ATTEN50X|ATTEN55X|ATTEN60X|ATTEN65X|ATTEN70X|ATTEN75X|ATTEN80X|ATTEN85X|ATTEN90X|ATTEN95X|ATTEN100X|ATTEN125X|ATTEN150X|ATTEN175X|ATTEN200X|ATTEN250X|ATTEN300X|ATTEN350X|ATTEN400X|ATTEN450X|ATTEN500X|ATTEN550X|ATTEN600X|ATTEN650X|ATTEN700X|ATTEN750X|ATTEN800X|ATTEN850X|ATTEN900X|ATTEN950X|ATTEN1000X}
- AUXIn:PRObe:RANge?
- AUXIn:PRObe:RESistance?
- AUXIn:PRObe:SET <QString>
- AUXIn:PRObe:SET?
- AUXIn:PRObe:SIGnal {PASS|BYPass}
- AUXIn:PRObe:SIGnal?
- AUXIn:PRObe:TIPtype {HBWStraightflex|OTHer}
- AUXIn:PRObe:TIPtype?
- AUXIn:PRObe:UNIts?
- AUXIn:VTERm:DUAL:A <NR3>
- AUXIn:VTERm:DUAL:A?
- AUXIn:VTERm:DUAL:B <NR3>
- AUXIn:VTERm:DUAL:B?
Auxin
¶
Bases: SCPICmdRead
The AUXIn command tree.
Usage
- Using the
.query()method will send theAUXIn?query. - Using the
.verify(value)method will send theAUXIn?query and raise an AssertionError if the returned value does not matchvalue.
Properties
.bandwidth: TheAUXIn:BANdwidthcommand..coupling: TheAUXIn:COUPlingcommand..offset: TheAUXIn:OFFSetcommand..probefunc: TheAUXIn:PROBEFunccommand tree..probe: TheAUXIn:PRObecommand tree..vterm: TheAUXIn:VTERmcommand tree.
bandwidth
property
¶
bandwidth: AuxinBandwidth
Return the AUXIn:BANdwidth command.
Description
- This command sets or queries the selectable low-pass bandwidth limit filter of the AUX In input. The bandwidth will change with an appropriate probe attached. This is equivalent to selecting Bandwidth from the Vertical menu. The query form of this command always returns the maximum bandwidth of the AUX In input.
Usage
- Using the
.query()method will send theAUXIn:BANdwidth?query. - Using the
.verify(value)method will send theAUXIn:BANdwidth?query and raise an AssertionError if the returned value does not matchvalue. - Using the
.write(value)method will send theAUXIn:BANdwidth valuecommand.
SCPI Syntax
- AUXIn:BANdwidth <NR3>
- AUXIn:BANdwidth?
Info
<NR3>is one of the supported bandwidths on the attached probe.
coupling
property
¶
coupling: AuxinCoupling
Return the AUXIn:COUPling command.
Description
- This command sets or queries the input attenuator coupling setting for the AUX In input. The coupling will change with an appropriate probe attached. This command is equivalent to selecting Coupling from the Vertical menu.
Usage
- Using the
.query()method will send theAUXIn:COUPling?query. - Using the
.verify(value)method will send theAUXIn:COUPling?query and raise an AssertionError if the returned value does not matchvalue. - Using the
.write(value)method will send theAUXIn:COUPling valuecommand.
SCPI Syntax
- AUXIn:COUPling <NR3>
- AUXIn:COUPling?
Info
<NR3>is one of the supported input attenuator couplings on the attached probe.
offset
property
¶
offset: AuxinOffset
Return the AUXIn:OFFSet command.
Description
- This command sets or queries the vertical offset for the AUX In input. This command is equivalent to selecting Offset from the Vertical menu. This command offsets the vertical acquisition window (moves the level at the vertical center of the acquisition window) for the input. Visualize offset as scrolling the acquisition window towards the top of a large signal for increased offset values, and scrolling towards the bottom for decreased offset values. The resolution of the vertical window sets the offset increment for this control. Offset adjusts only the vertical center of the acquisition window to help determine what data is acquired. The instrument always displays the input signal minus the offset value. The channel reference marker will move to the vertical graticule position given by the negative of the offset value divided by the scale factor, unless that position is off-screen. If the computed coordinate for the reference mark is off-screen, the mark moves to the nearest screen limit and changes from a right-pointing arrow ( →) to an arrow pointing in the appropriate off-screen direction.
Usage
- Using the
.query()method will send theAUXIn:OFFSet?query. - Using the
.verify(value)method will send theAUXIn:OFFSet?query and raise an AssertionError if the returned value does not matchvalue. - Using the
.write(value)method will send theAUXIn:OFFSet valuecommand.
SCPI Syntax
- AUXIn:OFFSet <NR3>
- AUXIn:OFFSet?
Info
<NR3>is the offset value for the specified channel.
probe
property
¶
probe: AuxinProbe
Return the AUXIn:PRObe command tree.
Usage
- Using the
.query()method will send theAUXIn:PRObe?query. - Using the
.verify(value)method will send theAUXIn:PRObe?query and raise an AssertionError if the returned value does not matchvalue.
Sub-properties
.autozero: TheAUXIn:PRObe:AUTOZerocommand..degauss: TheAUXIn:PRObe:DEGAUSScommand..forcedrange: TheAUXIn:PRObe:FORCEDRangecommand..gain: TheAUXIn:PRObe:GAINcommand..id: TheAUXIn:PRObe:IDcommand tree..inputmode: TheAUXIn:PRObe:INPUTModecommand..range: TheAUXIn:PRObe:RANgecommand..resistance: TheAUXIn:PRObe:RESistancecommand..set: TheAUXIn:PRObe:SETcommand..signal: TheAUXIn:PRObe:SIGnalcommand..tiptype: TheAUXIn:PRObe:TIPtypecommand..units: TheAUXIn:PRObe:UNItscommand.
probefunc
property
¶
probefunc: AuxinProbefunc
Return the AUXIn:PROBEFunc command tree.
Usage
- Using the
.query()method will send theAUXIn:PROBEFunc?query. - Using the
.verify(value)method will send theAUXIn:PROBEFunc?query and raise an AssertionError if the returned value does not matchvalue.
Sub-properties
.extatten: TheAUXIn:PROBEFunc:EXTAttencommand..extdbatten: TheAUXIn:PROBEFunc:EXTDBattencommand..extunits: TheAUXIn:PROBEFunc:EXTUnitscommand.
vterm
property
¶
vterm: AuxinVterm
Return the AUXIn:VTERm command tree.
Usage
- Using the
.query()method will send theAUXIn:VTERm?query. - Using the
.verify(value)method will send theAUXIn:VTERm?query and raise an AssertionError if the returned value does not matchvalue.
Sub-properties
.dual: TheAUXIn:VTERm:DUALcommand tree.
AuxinBandwidth
¶
Bases: SCPICmdWrite, SCPICmdRead
The AUXIn:BANdwidth command.
Description
- This command sets or queries the selectable low-pass bandwidth limit filter of the AUX In input. The bandwidth will change with an appropriate probe attached. This is equivalent to selecting Bandwidth from the Vertical menu. The query form of this command always returns the maximum bandwidth of the AUX In input.
Usage
- Using the
.query()method will send theAUXIn:BANdwidth?query. - Using the
.verify(value)method will send theAUXIn:BANdwidth?query and raise an AssertionError if the returned value does not matchvalue. - Using the
.write(value)method will send theAUXIn:BANdwidth valuecommand.
SCPI Syntax
- AUXIn:BANdwidth <NR3>
- AUXIn:BANdwidth?
Info
<NR3>is one of the supported bandwidths on the attached probe.
AuxinCoupling
¶
Bases: SCPICmdWrite, SCPICmdRead
The AUXIn:COUPling command.
Description
- This command sets or queries the input attenuator coupling setting for the AUX In input. The coupling will change with an appropriate probe attached. This command is equivalent to selecting Coupling from the Vertical menu.
Usage
- Using the
.query()method will send theAUXIn:COUPling?query. - Using the
.verify(value)method will send theAUXIn:COUPling?query and raise an AssertionError if the returned value does not matchvalue. - Using the
.write(value)method will send theAUXIn:COUPling valuecommand.
SCPI Syntax
- AUXIn:COUPling <NR3>
- AUXIn:COUPling?
Info
<NR3>is one of the supported input attenuator couplings on the attached probe.
AuxinOffset
¶
Bases: SCPICmdWrite, SCPICmdRead
The AUXIn:OFFSet command.
Description
- This command sets or queries the vertical offset for the AUX In input. This command is equivalent to selecting Offset from the Vertical menu. This command offsets the vertical acquisition window (moves the level at the vertical center of the acquisition window) for the input. Visualize offset as scrolling the acquisition window towards the top of a large signal for increased offset values, and scrolling towards the bottom for decreased offset values. The resolution of the vertical window sets the offset increment for this control. Offset adjusts only the vertical center of the acquisition window to help determine what data is acquired. The instrument always displays the input signal minus the offset value. The channel reference marker will move to the vertical graticule position given by the negative of the offset value divided by the scale factor, unless that position is off-screen. If the computed coordinate for the reference mark is off-screen, the mark moves to the nearest screen limit and changes from a right-pointing arrow ( →) to an arrow pointing in the appropriate off-screen direction.
Usage
- Using the
.query()method will send theAUXIn:OFFSet?query. - Using the
.verify(value)method will send theAUXIn:OFFSet?query and raise an AssertionError if the returned value does not matchvalue. - Using the
.write(value)method will send theAUXIn:OFFSet valuecommand.
SCPI Syntax
- AUXIn:OFFSet <NR3>
- AUXIn:OFFSet?
Info
<NR3>is the offset value for the specified channel.
AuxinProbe
¶
Bases: SCPICmdRead
The AUXIn:PRObe command tree.
Usage
- Using the
.query()method will send theAUXIn:PRObe?query. - Using the
.verify(value)method will send theAUXIn:PRObe?query and raise an AssertionError if the returned value does not matchvalue.
Properties
.autozero: TheAUXIn:PRObe:AUTOZerocommand..degauss: TheAUXIn:PRObe:DEGAUSScommand..forcedrange: TheAUXIn:PRObe:FORCEDRangecommand..gain: TheAUXIn:PRObe:GAINcommand..id: TheAUXIn:PRObe:IDcommand tree..inputmode: TheAUXIn:PRObe:INPUTModecommand..range: TheAUXIn:PRObe:RANgecommand..resistance: TheAUXIn:PRObe:RESistancecommand..set: TheAUXIn:PRObe:SETcommand..signal: TheAUXIn:PRObe:SIGnalcommand..tiptype: TheAUXIn:PRObe:TIPtypecommand..units: TheAUXIn:PRObe:UNItscommand.
autozero
property
¶
autozero: AuxinProbeAutozero
Return the AUXIn:PRObe:AUTOZero command.
Description
- The command sets the probe attached to the AUX In input to autozero.
Usage
- Using the
.write(value)method will send theAUXIn:PRObe:AUTOZero valuecommand.
SCPI Syntax
- AUXIn:PRObe:AUTOZero EXECute
Info
EXECutesets the probe to autozero.
degauss
property
¶
degauss: AuxinProbeDegauss
Return the AUXIn:PRObe:DEGAUSS command.
Description
- This command starts a degauss cycle of the probe attached to the AUX In input. The degauss cycle will change with an appropriate probe attached.
Usage
- Using the
.write(value)method will send theAUXIn:PRObe:DEGAUSS valuecommand.
SCPI Syntax
- AUXIn:PRObe:DEGAUSS EXECute
Info
EXECutestarts a probe degauss cycle.
Sub-properties
.state: TheAUXIn:PRObe:DEGAUSS:STATEcommand.
forcedrange
property
¶
forcedrange: AuxinProbeForcedrange
Return the AUXIn:PRObe:FORCEDRange command.
Description
- This command sets the probe attached to the AUX In input to the specified range, or the command queries the probe range.
Usage
- Using the
.query()method will send theAUXIn:PRObe:FORCEDRange?query. - Using the
.verify(value)method will send theAUXIn:PRObe:FORCEDRange?query and raise an AssertionError if the returned value does not matchvalue. - Using the
.write(value)method will send theAUXIn:PRObe:FORCEDRange valuecommand.
SCPI Syntax
- AUXIn:PRObe:FORCEDRange <NR3>
- AUXIn:PRObe:FORCEDRange?
Info
<NR3>specifies the probe range.
gain
property
¶
gain: AuxinProbeGain
Return the AUXIn:PRObe:GAIN command.
Description
- This query-only command returns the gain factor of the probe that is attached to the AUX In input. The ‘gain’ of a probe is the output divided by the input transfer ratio. For example, a common 10x probe has a gain of 0.1.
Usage
- Using the
.query()method will send theAUXIn:PRObe:GAIN?query. - Using the
.verify(value)method will send theAUXIn:PRObe:GAIN?query and raise an AssertionError if the returned value does not matchvalue.
SCPI Syntax
- AUXIn:PRObe:GAIN?
id
property
¶
id: AuxinProbeId
Return the AUXIn:PRObe:ID command tree.
Usage
- Using the
.query()method will send theAUXIn:PRObe:ID?query. - Using the
.verify(value)method will send theAUXIn:PRObe:ID?query and raise an AssertionError if the returned value does not matchvalue.
Sub-properties
.sernumber: TheAUXIn:PRObe:ID:SERnumbercommand..type: TheAUXIn:PRObe:ID:TYPecommand.
inputmode
property
¶
inputmode: AuxinProbeInputmode
Return the AUXIn:PRObe:INPUTMode command.
Description
- This command sets or queries one of the probe’s four input modes on the AUX In input.
Usage
- Using the
.query()method will send theAUXIn:PRObe:INPUTMode?query. - Using the
.verify(value)method will send theAUXIn:PRObe:INPUTMode?query and raise an AssertionError if the returned value does not matchvalue. - Using the
.write(value)method will send theAUXIn:PRObe:INPUTMode valuecommand.
SCPI Syntax
- AUXIn:PRObe:INPUTMode {COMmonmode|DEFault|DIFFerential|A|B}
- AUXIn:PRObe:INPUTMode?
Info
COMmonmodesets the probe to route common-mode signals to the host.DEFaultsets the probe to the default mode.DIFFerentialsets the probe to route differential signals to the host.Asets the probe to route single-ended A signals to the host.Bsets the probe to route single-ended B signals to the host.
Sub-properties
.aoffset: TheAUXIn:PRObe:INPUTMode:AOFFSetcommand..boffset: TheAUXIn:PRObe:INPUTMode:BOFFSetcommand..cmoffset: TheAUXIn:PRObe:INPUTMode:CMOFFSetcommand..dmoffset: TheAUXIn:PRObe:INPUTMode:DMOFFSetcommand.
range
property
¶
range: AuxinProbeRange
Return the AUXIn:PRObe:RANge command.
Description
- This command controls or queries the set attenuation range of the probe on the AUX In input.
Usage
- Using the
.query()method will send theAUXIn:PRObe:RANge?query. - Using the
.verify(value)method will send theAUXIn:PRObe:RANge?query and raise an AssertionError if the returned value does not matchvalue. - Using the
.write(value)method will send theAUXIn:PRObe:RANge valuecommand.
SCPI Syntax
- AUXIn:PRObe:RANge {ATTEN1X|ATTEN1_25X|ATTEN1_5X|ATTEN1_75X|ATTEN2X|ATTEN2_5X|ATTEN3X|ATTEN3_5X|ATTEN4X|ATTEN4_5X|ATTEN5X|ATTEN5_5X|ATTEN6X|ATTEN6_5X|ATTEN7X|ATTEN7_5X|ATTEN8X|ATTEN8_5X|ATTEN9X|ATTEN9_5X|ATTEN10X|ATTEN12_5X|ATTEN15X|ATTEN17_5X|ATTEN20X|ATTEN25X|ATTEN30X|ATTEN35X|ATTEN40X|ATTEN45X|ATTEN50X|ATTEN55X|ATTEN60X|ATTEN65X|ATTEN70X|ATTEN75X|ATTEN80X|ATTEN85X|ATTEN90X|ATTEN95X|ATTEN100X|ATTEN125X|ATTEN150X|ATTEN175X|ATTEN200X|ATTEN250X|ATTEN300X|ATTEN350X|ATTEN400X|ATTEN450X|ATTEN500X|ATTEN550X|ATTEN600X|ATTEN650X|ATTEN700X|ATTEN750X|ATTEN800X|ATTEN850X|ATTEN900X|ATTEN950X|ATTEN1000X}
- AUXIn:PRObe:RANge?
resistance
property
¶
resistance: AuxinProbeResistance
Return the AUXIn:PRObe:RESistance command.
Description
- This query-only command returns the resistance factor of the probe that is attached to the AUX In input.
Usage
- Using the
.query()method will send theAUXIn:PRObe:RESistance?query. - Using the
.verify(value)method will send theAUXIn:PRObe:RESistance?query and raise an AssertionError if the returned value does not matchvalue.
SCPI Syntax
- AUXIn:PRObe:RESistance?
set_
property
¶
set_: AuxinProbeSet
Return the AUXIn:PRObe:SET command.
Description
- This command sets or queries aspects of probe accessory user interfaces, for example probe attenuation factors. The available arguments for this command will vary depending on the accessory you attach to the instrument auxiliary trigger input. For the P7260 probe, you can select between two attenuation factors using either this GPIB command or the push switch on the probe. The probe enables the relevant path and adjusts the settings based on the characteristics of the path in use. The probe signal path selection is not kept in persistent storage. The probe will lose the selection if you reboot the instrument or remove the probe. Also, the instrument does not store the selection in the save/recall setup operation.
Usage
- Using the
.query()method will send theAUXIn:PRObe:SET?query. - Using the
.verify(value)method will send theAUXIn:PRObe:SET?query and raise an AssertionError if the returned value does not matchvalue. - Using the
.write(value)method will send theAUXIn:PRObe:SET valuecommand.
SCPI Syntax
- AUXIn:PRObe:SET <QString>
- AUXIn:PRObe:SET?
Info
<QString>is a quoted string representing a settable aspect of the attached accessory.ATTENUATION 5Xsets the P7260 probe to ±0.75 V dynamic range with 6 GHz bandwidth and 5X attenuation.ATTENUATION 25Xsets the P7260 probe to ±3 V dynamic range with 6 GHz bandwidth and 25X attenuation.VTERMsource AUTOsets the P7380SMA probe voltage termination source to auto.VTERMsource INTernalsets the P7380SMA probe voltage termination source to internal.VTERMsource EXTernalsets the P7380SMA probe voltage termination source to external.
signal
property
¶
signal: AuxinProbeSignal
Return the AUXIn:PRObe:SIGnal command.
Description
- This command sets or queries aspects of probe accessory user interfaces. The available arguments for this command will vary depending on the accessory you attach to the instrument.
Usage
- Using the
.query()method will send theAUXIn:PRObe:SIGnal?query. - Using the
.verify(value)method will send theAUXIn:PRObe:SIGnal?query and raise an AssertionError if the returned value does not matchvalue. - Using the
.write(value)method will send theAUXIn:PRObe:SIGnal valuecommand.
SCPI Syntax
- AUXIn:PRObe:SIGnal {PASS|BYPass}
- AUXIn:PRObe:SIGnal?
Info
PASSopens a relay passing your signal to the instrument.BYPasscloses a relay preventing your signal from reaching the instrument. During probe degauss, the signal should be bypassed.
tiptype
property
¶
tiptype: AuxinProbeTiptype
Return the AUXIn:PRObe:TIPtype command.
Description
- This command sets or queries the type of probe tip being used.
Usage
- Using the
.query()method will send theAUXIn:PRObe:TIPtype?query. - Using the
.verify(value)method will send theAUXIn:PRObe:TIPtype?query and raise an AssertionError if the returned value does not matchvalue. - Using the
.write(value)method will send theAUXIn:PRObe:TIPtype valuecommand.
SCPI Syntax
- AUXIn:PRObe:TIPtype {HBWStraightflex|OTHer}
- AUXIn:PRObe:TIPtype?
Info
HBWStraightflexlets the instrument know you are using a high bandwidth straight-flex probe tip.OTHerlets the instrument know you are not using a high bandwidth straight-flex probe tip.
units
property
¶
units: AuxinProbeUnits
Return the AUXIn:PRObe:UNIts command.
Description
- This query-only command returns a string describing the units of measure for the probe attached to the AUX In input.
Usage
- Using the
.query()method will send theAUXIn:PRObe:UNIts?query. - Using the
.verify(value)method will send theAUXIn:PRObe:UNIts?query and raise an AssertionError if the returned value does not matchvalue.
SCPI Syntax
- AUXIn:PRObe:UNIts?
AuxinProbeAutozero
¶
Bases: SCPICmdWrite
The AUXIn:PRObe:AUTOZero command.
Description
- The command sets the probe attached to the AUX In input to autozero.
Usage
- Using the
.write(value)method will send theAUXIn:PRObe:AUTOZero valuecommand.
SCPI Syntax
- AUXIn:PRObe:AUTOZero EXECute
Info
EXECutesets the probe to autozero.
AuxinProbeDegauss
¶
Bases: SCPICmdWrite, SCPICmdRead
The AUXIn:PRObe:DEGAUSS command.
Description
- This command starts a degauss cycle of the probe attached to the AUX In input. The degauss cycle will change with an appropriate probe attached.
Usage
- Using the
.write(value)method will send theAUXIn:PRObe:DEGAUSS valuecommand.
SCPI Syntax
- AUXIn:PRObe:DEGAUSS EXECute
Info
EXECutestarts a probe degauss cycle.
Properties
.state: TheAUXIn:PRObe:DEGAUSS:STATEcommand.
state
property
¶
state: AuxinProbeDegaussState
Return the AUXIn:PRObe:DEGAUSS:STATE command.
Description
- This command queries whether the probe attached to the AUX In input is degaussed.
Usage
- Using the
.query()method will send theAUXIn:PRObe:DEGAUSS:STATE?query. - Using the
.verify(value)method will send theAUXIn:PRObe:DEGAUSS:STATE?query and raise an AssertionError if the returned value does not matchvalue.
SCPI Syntax
- AUXIn:PRObe:DEGAUSS:STATE?
AuxinProbeDegaussState
¶
Bases: SCPICmdRead
The AUXIn:PRObe:DEGAUSS:STATE command.
Description
- This command queries whether the probe attached to the AUX In input is degaussed.
Usage
- Using the
.query()method will send theAUXIn:PRObe:DEGAUSS:STATE?query. - Using the
.verify(value)method will send theAUXIn:PRObe:DEGAUSS:STATE?query and raise an AssertionError if the returned value does not matchvalue.
SCPI Syntax
- AUXIn:PRObe:DEGAUSS:STATE?
AuxinProbeForcedrange
¶
Bases: SCPICmdWrite, SCPICmdRead
The AUXIn:PRObe:FORCEDRange command.
Description
- This command sets the probe attached to the AUX In input to the specified range, or the command queries the probe range.
Usage
- Using the
.query()method will send theAUXIn:PRObe:FORCEDRange?query. - Using the
.verify(value)method will send theAUXIn:PRObe:FORCEDRange?query and raise an AssertionError if the returned value does not matchvalue. - Using the
.write(value)method will send theAUXIn:PRObe:FORCEDRange valuecommand.
SCPI Syntax
- AUXIn:PRObe:FORCEDRange <NR3>
- AUXIn:PRObe:FORCEDRange?
Info
<NR3>specifies the probe range.
AuxinProbeGain
¶
Bases: SCPICmdRead
The AUXIn:PRObe:GAIN command.
Description
- This query-only command returns the gain factor of the probe that is attached to the AUX In input. The ‘gain’ of a probe is the output divided by the input transfer ratio. For example, a common 10x probe has a gain of 0.1.
Usage
- Using the
.query()method will send theAUXIn:PRObe:GAIN?query. - Using the
.verify(value)method will send theAUXIn:PRObe:GAIN?query and raise an AssertionError if the returned value does not matchvalue.
SCPI Syntax
- AUXIn:PRObe:GAIN?
AuxinProbeId
¶
Bases: SCPICmdRead
The AUXIn:PRObe:ID command tree.
Usage
- Using the
.query()method will send theAUXIn:PRObe:ID?query. - Using the
.verify(value)method will send theAUXIn:PRObe:ID?query and raise an AssertionError if the returned value does not matchvalue.
Properties
.sernumber: TheAUXIn:PRObe:ID:SERnumbercommand..type: TheAUXIn:PRObe:ID:TYPecommand.
sernumber
property
¶
sernumber: AuxinProbeIdSernumber
Return the AUXIn:PRObe:ID:SERnumber command.
Description
- This query-only command returns the probe serial number.
Usage
- Using the
.query()method will send theAUXIn:PRObe:ID:SERnumber?query. - Using the
.verify(value)method will send theAUXIn:PRObe:ID:SERnumber?query and raise an AssertionError if the returned value does not matchvalue.
SCPI Syntax
- AUXIn:PRObe:ID:SERnumber?
type
property
¶
type: AuxinProbeIdType
Return the AUXIn:PRObe:ID:TYPe command.
Description
- This query-only command returns the probe type.
Usage
- Using the
.query()method will send theAUXIn:PRObe:ID:TYPe?query. - Using the
.verify(value)method will send theAUXIn:PRObe:ID:TYPe?query and raise an AssertionError if the returned value does not matchvalue.
SCPI Syntax
- AUXIn:PRObe:ID:TYPe?
AuxinProbeIdSernumber
¶
Bases: SCPICmdRead
The AUXIn:PRObe:ID:SERnumber command.
Description
- This query-only command returns the probe serial number.
Usage
- Using the
.query()method will send theAUXIn:PRObe:ID:SERnumber?query. - Using the
.verify(value)method will send theAUXIn:PRObe:ID:SERnumber?query and raise an AssertionError if the returned value does not matchvalue.
SCPI Syntax
- AUXIn:PRObe:ID:SERnumber?
AuxinProbeIdType
¶
Bases: SCPICmdRead
The AUXIn:PRObe:ID:TYPe command.
Description
- This query-only command returns the probe type.
Usage
- Using the
.query()method will send theAUXIn:PRObe:ID:TYPe?query. - Using the
.verify(value)method will send theAUXIn:PRObe:ID:TYPe?query and raise an AssertionError if the returned value does not matchvalue.
SCPI Syntax
- AUXIn:PRObe:ID:TYPe?
AuxinProbeInputmode
¶
Bases: SCPICmdWrite, SCPICmdRead
The AUXIn:PRObe:INPUTMode command.
Description
- This command sets or queries one of the probe’s four input modes on the AUX In input.
Usage
- Using the
.query()method will send theAUXIn:PRObe:INPUTMode?query. - Using the
.verify(value)method will send theAUXIn:PRObe:INPUTMode?query and raise an AssertionError if the returned value does not matchvalue. - Using the
.write(value)method will send theAUXIn:PRObe:INPUTMode valuecommand.
SCPI Syntax
- AUXIn:PRObe:INPUTMode {COMmonmode|DEFault|DIFFerential|A|B}
- AUXIn:PRObe:INPUTMode?
Info
COMmonmodesets the probe to route common-mode signals to the host.DEFaultsets the probe to the default mode.DIFFerentialsets the probe to route differential signals to the host.Asets the probe to route single-ended A signals to the host.Bsets the probe to route single-ended B signals to the host.
Properties
.aoffset: TheAUXIn:PRObe:INPUTMode:AOFFSetcommand..boffset: TheAUXIn:PRObe:INPUTMode:BOFFSetcommand..cmoffset: TheAUXIn:PRObe:INPUTMode:CMOFFSetcommand..dmoffset: TheAUXIn:PRObe:INPUTMode:DMOFFSetcommand.
aoffset
property
¶
aoffset: AuxinProbeInputmodeAoffset
Return the AUXIn:PRObe:INPUTMode:AOFFSet command.
Description
- This command sets or queries the requested A mode offset control of the probe that is attached to the AUX In input.
Usage
- Using the
.query()method will send theAUXIn:PRObe:INPUTMode:AOFFSet?query. - Using the
.verify(value)method will send theAUXIn:PRObe:INPUTMode:AOFFSet?query and raise an AssertionError if the returned value does not matchvalue. - Using the
.write(value)method will send theAUXIn:PRObe:INPUTMode:AOFFSet valuecommand.
SCPI Syntax
- AUXIn:PRObe:INPUTMode:AOFFSet <NR3>
- AUXIn:PRObe:INPUTMode:AOFFSet?
Info
<NR3>specifies the A mode offset control.
boffset
property
¶
boffset: AuxinProbeInputmodeBoffset
Return the AUXIn:PRObe:INPUTMode:BOFFSet command.
Description
- This command sets or queries the requested B mode offset control of the probe that is attached to the AUX In input.
Usage
- Using the
.query()method will send theAUXIn:PRObe:INPUTMode:BOFFSet?query. - Using the
.verify(value)method will send theAUXIn:PRObe:INPUTMode:BOFFSet?query and raise an AssertionError if the returned value does not matchvalue. - Using the
.write(value)method will send theAUXIn:PRObe:INPUTMode:BOFFSet valuecommand.
SCPI Syntax
- AUXIn:PRObe:INPUTMode:BOFFSet <NR3>
- AUXIn:PRObe:INPUTMode:BOFFSet?
Info
<NR3>specifies the B mode offset control.
cmoffset
property
¶
cmoffset: AuxinProbeInputmodeCmoffset
Return the AUXIn:PRObe:INPUTMode:CMOFFSet command.
Description
- This command sets or queries the requested common mode offset control of the probe that is attached to the AUX In input.
Usage
- Using the
.query()method will send theAUXIn:PRObe:INPUTMode:CMOFFSet?query. - Using the
.verify(value)method will send theAUXIn:PRObe:INPUTMode:CMOFFSet?query and raise an AssertionError if the returned value does not matchvalue. - Using the
.write(value)method will send theAUXIn:PRObe:INPUTMode:CMOFFSet valuecommand.
SCPI Syntax
- AUXIn:PRObe:INPUTMode:CMOFFSet <NR3>
- AUXIn:PRObe:INPUTMode:CMOFFSet?
Info
<NR3>specifies the common mode offset control.
dmoffset
property
¶
dmoffset: AuxinProbeInputmodeDmoffset
Return the AUXIn:PRObe:INPUTMode:DMOFFSet command.
Description
- This command sets or queries the requested differential mode offset control of the probe that is attached to the AUX In input.
Usage
- Using the
.query()method will send theAUXIn:PRObe:INPUTMode:DMOFFSet?query. - Using the
.verify(value)method will send theAUXIn:PRObe:INPUTMode:DMOFFSet?query and raise an AssertionError if the returned value does not matchvalue. - Using the
.write(value)method will send theAUXIn:PRObe:INPUTMode:DMOFFSet valuecommand.
SCPI Syntax
- AUXIn:PRObe:INPUTMode:DMOFFSet <NR3>
- AUXIn:PRObe:INPUTMode:DMOFFSet?
Info
<NR3>specifies the differential mode offset control.
AuxinProbeInputmodeAoffset
¶
Bases: SCPICmdWrite, SCPICmdRead
The AUXIn:PRObe:INPUTMode:AOFFSet command.
Description
- This command sets or queries the requested A mode offset control of the probe that is attached to the AUX In input.
Usage
- Using the
.query()method will send theAUXIn:PRObe:INPUTMode:AOFFSet?query. - Using the
.verify(value)method will send theAUXIn:PRObe:INPUTMode:AOFFSet?query and raise an AssertionError if the returned value does not matchvalue. - Using the
.write(value)method will send theAUXIn:PRObe:INPUTMode:AOFFSet valuecommand.
SCPI Syntax
- AUXIn:PRObe:INPUTMode:AOFFSet <NR3>
- AUXIn:PRObe:INPUTMode:AOFFSet?
Info
<NR3>specifies the A mode offset control.
AuxinProbeInputmodeBoffset
¶
Bases: SCPICmdWrite, SCPICmdRead
The AUXIn:PRObe:INPUTMode:BOFFSet command.
Description
- This command sets or queries the requested B mode offset control of the probe that is attached to the AUX In input.
Usage
- Using the
.query()method will send theAUXIn:PRObe:INPUTMode:BOFFSet?query. - Using the
.verify(value)method will send theAUXIn:PRObe:INPUTMode:BOFFSet?query and raise an AssertionError if the returned value does not matchvalue. - Using the
.write(value)method will send theAUXIn:PRObe:INPUTMode:BOFFSet valuecommand.
SCPI Syntax
- AUXIn:PRObe:INPUTMode:BOFFSet <NR3>
- AUXIn:PRObe:INPUTMode:BOFFSet?
Info
<NR3>specifies the B mode offset control.
AuxinProbeInputmodeCmoffset
¶
Bases: SCPICmdWrite, SCPICmdRead
The AUXIn:PRObe:INPUTMode:CMOFFSet command.
Description
- This command sets or queries the requested common mode offset control of the probe that is attached to the AUX In input.
Usage
- Using the
.query()method will send theAUXIn:PRObe:INPUTMode:CMOFFSet?query. - Using the
.verify(value)method will send theAUXIn:PRObe:INPUTMode:CMOFFSet?query and raise an AssertionError if the returned value does not matchvalue. - Using the
.write(value)method will send theAUXIn:PRObe:INPUTMode:CMOFFSet valuecommand.
SCPI Syntax
- AUXIn:PRObe:INPUTMode:CMOFFSet <NR3>
- AUXIn:PRObe:INPUTMode:CMOFFSet?
Info
<NR3>specifies the common mode offset control.
AuxinProbeInputmodeDmoffset
¶
Bases: SCPICmdWrite, SCPICmdRead
The AUXIn:PRObe:INPUTMode:DMOFFSet command.
Description
- This command sets or queries the requested differential mode offset control of the probe that is attached to the AUX In input.
Usage
- Using the
.query()method will send theAUXIn:PRObe:INPUTMode:DMOFFSet?query. - Using the
.verify(value)method will send theAUXIn:PRObe:INPUTMode:DMOFFSet?query and raise an AssertionError if the returned value does not matchvalue. - Using the
.write(value)method will send theAUXIn:PRObe:INPUTMode:DMOFFSet valuecommand.
SCPI Syntax
- AUXIn:PRObe:INPUTMode:DMOFFSet <NR3>
- AUXIn:PRObe:INPUTMode:DMOFFSet?
Info
<NR3>specifies the differential mode offset control.
AuxinProbeRange
¶
Bases: SCPICmdWrite, SCPICmdRead
The AUXIn:PRObe:RANge command.
Description
- This command controls or queries the set attenuation range of the probe on the AUX In input.
Usage
- Using the
.query()method will send theAUXIn:PRObe:RANge?query. - Using the
.verify(value)method will send theAUXIn:PRObe:RANge?query and raise an AssertionError if the returned value does not matchvalue. - Using the
.write(value)method will send theAUXIn:PRObe:RANge valuecommand.
SCPI Syntax
- AUXIn:PRObe:RANge {ATTEN1X|ATTEN1_25X|ATTEN1_5X|ATTEN1_75X|ATTEN2X|ATTEN2_5X|ATTEN3X|ATTEN3_5X|ATTEN4X|ATTEN4_5X|ATTEN5X|ATTEN5_5X|ATTEN6X|ATTEN6_5X|ATTEN7X|ATTEN7_5X|ATTEN8X|ATTEN8_5X|ATTEN9X|ATTEN9_5X|ATTEN10X|ATTEN12_5X|ATTEN15X|ATTEN17_5X|ATTEN20X|ATTEN25X|ATTEN30X|ATTEN35X|ATTEN40X|ATTEN45X|ATTEN50X|ATTEN55X|ATTEN60X|ATTEN65X|ATTEN70X|ATTEN75X|ATTEN80X|ATTEN85X|ATTEN90X|ATTEN95X|ATTEN100X|ATTEN125X|ATTEN150X|ATTEN175X|ATTEN200X|ATTEN250X|ATTEN300X|ATTEN350X|ATTEN400X|ATTEN450X|ATTEN500X|ATTEN550X|ATTEN600X|ATTEN650X|ATTEN700X|ATTEN750X|ATTEN800X|ATTEN850X|ATTEN900X|ATTEN950X|ATTEN1000X}
- AUXIn:PRObe:RANge?
AuxinProbeResistance
¶
Bases: SCPICmdRead
The AUXIn:PRObe:RESistance command.
Description
- This query-only command returns the resistance factor of the probe that is attached to the AUX In input.
Usage
- Using the
.query()method will send theAUXIn:PRObe:RESistance?query. - Using the
.verify(value)method will send theAUXIn:PRObe:RESistance?query and raise an AssertionError if the returned value does not matchvalue.
SCPI Syntax
- AUXIn:PRObe:RESistance?
AuxinProbeSet
¶
Bases: SCPICmdWrite, SCPICmdRead
The AUXIn:PRObe:SET command.
Description
- This command sets or queries aspects of probe accessory user interfaces, for example probe attenuation factors. The available arguments for this command will vary depending on the accessory you attach to the instrument auxiliary trigger input. For the P7260 probe, you can select between two attenuation factors using either this GPIB command or the push switch on the probe. The probe enables the relevant path and adjusts the settings based on the characteristics of the path in use. The probe signal path selection is not kept in persistent storage. The probe will lose the selection if you reboot the instrument or remove the probe. Also, the instrument does not store the selection in the save/recall setup operation.
Usage
- Using the
.query()method will send theAUXIn:PRObe:SET?query. - Using the
.verify(value)method will send theAUXIn:PRObe:SET?query and raise an AssertionError if the returned value does not matchvalue. - Using the
.write(value)method will send theAUXIn:PRObe:SET valuecommand.
SCPI Syntax
- AUXIn:PRObe:SET <QString>
- AUXIn:PRObe:SET?
Info
<QString>is a quoted string representing a settable aspect of the attached accessory.ATTENUATION 5Xsets the P7260 probe to ±0.75 V dynamic range with 6 GHz bandwidth and 5X attenuation.ATTENUATION 25Xsets the P7260 probe to ±3 V dynamic range with 6 GHz bandwidth and 25X attenuation.VTERMsource AUTOsets the P7380SMA probe voltage termination source to auto.VTERMsource INTernalsets the P7380SMA probe voltage termination source to internal.VTERMsource EXTernalsets the P7380SMA probe voltage termination source to external.
AuxinProbeSignal
¶
Bases: SCPICmdWrite, SCPICmdRead
The AUXIn:PRObe:SIGnal command.
Description
- This command sets or queries aspects of probe accessory user interfaces. The available arguments for this command will vary depending on the accessory you attach to the instrument.
Usage
- Using the
.query()method will send theAUXIn:PRObe:SIGnal?query. - Using the
.verify(value)method will send theAUXIn:PRObe:SIGnal?query and raise an AssertionError if the returned value does not matchvalue. - Using the
.write(value)method will send theAUXIn:PRObe:SIGnal valuecommand.
SCPI Syntax
- AUXIn:PRObe:SIGnal {PASS|BYPass}
- AUXIn:PRObe:SIGnal?
Info
PASSopens a relay passing your signal to the instrument.BYPasscloses a relay preventing your signal from reaching the instrument. During probe degauss, the signal should be bypassed.
AuxinProbeTiptype
¶
Bases: SCPICmdWrite, SCPICmdRead
The AUXIn:PRObe:TIPtype command.
Description
- This command sets or queries the type of probe tip being used.
Usage
- Using the
.query()method will send theAUXIn:PRObe:TIPtype?query. - Using the
.verify(value)method will send theAUXIn:PRObe:TIPtype?query and raise an AssertionError if the returned value does not matchvalue. - Using the
.write(value)method will send theAUXIn:PRObe:TIPtype valuecommand.
SCPI Syntax
- AUXIn:PRObe:TIPtype {HBWStraightflex|OTHer}
- AUXIn:PRObe:TIPtype?
Info
HBWStraightflexlets the instrument know you are using a high bandwidth straight-flex probe tip.OTHerlets the instrument know you are not using a high bandwidth straight-flex probe tip.
AuxinProbeUnits
¶
Bases: SCPICmdRead
The AUXIn:PRObe:UNIts command.
Description
- This query-only command returns a string describing the units of measure for the probe attached to the AUX In input.
Usage
- Using the
.query()method will send theAUXIn:PRObe:UNIts?query. - Using the
.verify(value)method will send theAUXIn:PRObe:UNIts?query and raise an AssertionError if the returned value does not matchvalue.
SCPI Syntax
- AUXIn:PRObe:UNIts?
AuxinProbefunc
¶
Bases: SCPICmdRead
The AUXIn:PROBEFunc command tree.
Usage
- Using the
.query()method will send theAUXIn:PROBEFunc?query. - Using the
.verify(value)method will send theAUXIn:PROBEFunc?query and raise an AssertionError if the returned value does not matchvalue.
Properties
.extatten: TheAUXIn:PROBEFunc:EXTAttencommand..extdbatten: TheAUXIn:PROBEFunc:EXTDBattencommand..extunits: TheAUXIn:PROBEFunc:EXTUnitscommand.
extatten
property
¶
extatten: AuxinProbefuncExtatten
Return the AUXIn:PROBEFunc:EXTAtten command.
Description
- This command sets the input-output ratio, of external attenuation or gain, between the
signal and the AUX In input. The query form of this command returns the user-specified
attenuation. Note that this command deals with an attenuation factor, not a gain
factor, unlike
CHX:PROBE(This command returns a value independent of the external attenuation). For example, if you specify a 20X attenuation factor, the commands return the following values (assuming that a 1x probe is presently attached, since the external attenuation is used in combination with the probe attenuation):AUXIN:PROBE:EXTA?20.00E+0AUXIN:PROBE?1.0E+0 This command is equivalent to selecting Attenuation from the Vertical menu, and then either viewing or setting Ext Atten.
Usage
- Using the
.query()method will send theAUXIn:PROBEFunc:EXTAtten?query. - Using the
.verify(value)method will send theAUXIn:PROBEFunc:EXTAtten?query and raise an AssertionError if the returned value does not matchvalue. - Using the
.write(value)method will send theAUXIn:PROBEFunc:EXTAtten valuecommand.
SCPI Syntax
- AUXIn:PROBEFunc:EXTAtten <NR3>
- AUXIn:PROBEFunc:EXTAtten?
Info
<NR3>is the attenuation value, which is specified as a multiplier in the range from 1.00E-10 to 1.00E+10.
extdbatten
property
¶
extdbatten: AuxinProbefuncExtdbatten
Return the AUXIn:PROBEFunc:EXTDBatten command.
Description
- This command sets the input-output ratio (expressed in decibel units) of external attenuation or gain between the signal and the instrument AUX In input. The query form of this command returns the user-specified attenuation in decibels: 1X = 0 dB, 10X = 20 dB, 100X = 40 dB, and similar things. This command is equivalent to selecting Attenuation from the Vertical menu, and then either viewing or setting Ext Att(dB).
Usage
- Using the
.query()method will send theAUXIn:PROBEFunc:EXTDBatten?query. - Using the
.verify(value)method will send theAUXIn:PROBEFunc:EXTDBatten?query and raise an AssertionError if the returned value does not matchvalue. - Using the
.write(value)method will send theAUXIn:PROBEFunc:EXTDBatten valuecommand.
SCPI Syntax
- AUXIn:PROBEFunc:EXTDBatten <NR3>
- AUXIn:PROBEFunc:EXTDBatten?
Info
<NR3>is the attenuation value, which is specified in the range from -200.00 dB to 200.00 dB.
extunits
property
¶
extunits: AuxinProbefuncExtunits
Return the AUXIn:PROBEFunc:EXTUnits command.
Description
- This command sets the unit of measurement for the external attenuator of the AUX In input. There is also a corresponding query that returns the user-specified unit of measurement for the external attenuator. Unless these units are set to the factory default string value of ‘None’, they become the attenuated units of measurement for the input. It is assumed that the probe connected to the input is of the correct type to receive the output of the user’s external transducer or network.
Usage
- Using the
.query()method will send theAUXIn:PROBEFunc:EXTUnits?query. - Using the
.verify(value)method will send theAUXIn:PROBEFunc:EXTUnits?query and raise an AssertionError if the returned value does not matchvalue. - Using the
.write(value)method will send theAUXIn:PROBEFunc:EXTUnits valuecommand.
SCPI Syntax
- AUXIn:PROBEFunc:EXTUnits <QString>
- AUXIn:PROBEFunc:EXTUnits?
Info
<QString>can contain a string of up to eight characters to indicate the attenuation unit of measurement for the AUX In input. However, most instrument attenuators only display the first two characters.
AuxinProbefuncExtatten
¶
Bases: SCPICmdWrite, SCPICmdRead
The AUXIn:PROBEFunc:EXTAtten command.
Description
- This command sets the input-output ratio, of external attenuation or gain, between the
signal and the AUX In input. The query form of this command returns the user-specified
attenuation. Note that this command deals with an attenuation factor, not a gain factor,
unlike
CHX:PROBE(This command returns a value independent of the external attenuation). For example, if you specify a 20X attenuation factor, the commands return the following values (assuming that a 1x probe is presently attached, since the external attenuation is used in combination with the probe attenuation):AUXIN:PROBE:EXTA?20.00E+0AUXIN:PROBE?1.0E+0 This command is equivalent to selecting Attenuation from the Vertical menu, and then either viewing or setting Ext Atten.
Usage
- Using the
.query()method will send theAUXIn:PROBEFunc:EXTAtten?query. - Using the
.verify(value)method will send theAUXIn:PROBEFunc:EXTAtten?query and raise an AssertionError if the returned value does not matchvalue. - Using the
.write(value)method will send theAUXIn:PROBEFunc:EXTAtten valuecommand.
SCPI Syntax
- AUXIn:PROBEFunc:EXTAtten <NR3>
- AUXIn:PROBEFunc:EXTAtten?
Info
<NR3>is the attenuation value, which is specified as a multiplier in the range from 1.00E-10 to 1.00E+10.
AuxinProbefuncExtdbatten
¶
Bases: SCPICmdWrite, SCPICmdRead
The AUXIn:PROBEFunc:EXTDBatten command.
Description
- This command sets the input-output ratio (expressed in decibel units) of external attenuation or gain between the signal and the instrument AUX In input. The query form of this command returns the user-specified attenuation in decibels: 1X = 0 dB, 10X = 20 dB, 100X = 40 dB, and similar things. This command is equivalent to selecting Attenuation from the Vertical menu, and then either viewing or setting Ext Att(dB).
Usage
- Using the
.query()method will send theAUXIn:PROBEFunc:EXTDBatten?query. - Using the
.verify(value)method will send theAUXIn:PROBEFunc:EXTDBatten?query and raise an AssertionError if the returned value does not matchvalue. - Using the
.write(value)method will send theAUXIn:PROBEFunc:EXTDBatten valuecommand.
SCPI Syntax
- AUXIn:PROBEFunc:EXTDBatten <NR3>
- AUXIn:PROBEFunc:EXTDBatten?
Info
<NR3>is the attenuation value, which is specified in the range from -200.00 dB to 200.00 dB.
AuxinProbefuncExtunits
¶
Bases: SCPICmdWrite, SCPICmdRead
The AUXIn:PROBEFunc:EXTUnits command.
Description
- This command sets the unit of measurement for the external attenuator of the AUX In input. There is also a corresponding query that returns the user-specified unit of measurement for the external attenuator. Unless these units are set to the factory default string value of ‘None’, they become the attenuated units of measurement for the input. It is assumed that the probe connected to the input is of the correct type to receive the output of the user’s external transducer or network.
Usage
- Using the
.query()method will send theAUXIn:PROBEFunc:EXTUnits?query. - Using the
.verify(value)method will send theAUXIn:PROBEFunc:EXTUnits?query and raise an AssertionError if the returned value does not matchvalue. - Using the
.write(value)method will send theAUXIn:PROBEFunc:EXTUnits valuecommand.
SCPI Syntax
- AUXIn:PROBEFunc:EXTUnits <QString>
- AUXIn:PROBEFunc:EXTUnits?
Info
<QString>can contain a string of up to eight characters to indicate the attenuation unit of measurement for the AUX In input. However, most instrument attenuators only display the first two characters.
AuxinVterm
¶
Bases: SCPICmdRead
The AUXIn:VTERm command tree.
Usage
- Using the
.query()method will send theAUXIn:VTERm?query. - Using the
.verify(value)method will send theAUXIn:VTERm?query and raise an AssertionError if the returned value does not matchvalue.
Properties
.dual: TheAUXIn:VTERm:DUALcommand tree.
dual
property
¶
dual: AuxinVtermDual
Return the AUXIn:VTERm:DUAL command tree.
Usage
- Using the
.query()method will send theAUXIn:VTERm:DUAL?query. - Using the
.verify(value)method will send theAUXIn:VTERm:DUAL?query and raise an AssertionError if the returned value does not matchvalue.
Sub-properties
.a: TheAUXIn:VTERm:DUAL:Acommand..b: TheAUXIn:VTERm:DUAL:Bcommand.
AuxinVtermDual
¶
Bases: SCPICmdRead
The AUXIn:VTERm:DUAL command tree.
Usage
- Using the
.query()method will send theAUXIn:VTERm:DUAL?query. - Using the
.verify(value)method will send theAUXIn:VTERm:DUAL?query and raise an AssertionError if the returned value does not matchvalue.
Properties
.a: TheAUXIn:VTERm:DUAL:Acommand..b: TheAUXIn:VTERm:DUAL:Bcommand.
a
property
¶
Return the AUXIn:VTERm:DUAL:A command.
Description
- This command sets or queries the termination voltage for probes with dual inputs that support settable termination voltage.
Usage
- Using the
.query()method will send theAUXIn:VTERm:DUAL:A?query. - Using the
.verify(value)method will send theAUXIn:VTERm:DUAL:A?query and raise an AssertionError if the returned value does not matchvalue. - Using the
.write(value)method will send theAUXIn:VTERm:DUAL:A valuecommand.
SCPI Syntax
- AUXIn:VTERm:DUAL:A <NR3>
- AUXIn:VTERm:DUAL:A?
Info
<NR3>specifies the termination voltage.
b
property
¶
Return the AUXIn:VTERm:DUAL:B command.
Description
- This command sets or queries the termination voltage for probes with dual inputs that support settable termination voltage.
Usage
- Using the
.query()method will send theAUXIn:VTERm:DUAL:B?query. - Using the
.verify(value)method will send theAUXIn:VTERm:DUAL:B?query and raise an AssertionError if the returned value does not matchvalue. - Using the
.write(value)method will send theAUXIn:VTERm:DUAL:B valuecommand.
SCPI Syntax
- AUXIn:VTERm:DUAL:B <NR3>
- AUXIn:VTERm:DUAL:B?
Info
<NR3>specifies the termination voltage.
AuxinVtermDualA
¶
Bases: SCPICmdWrite, SCPICmdRead
The AUXIn:VTERm:DUAL:A command.
Description
- This command sets or queries the termination voltage for probes with dual inputs that support settable termination voltage.
Usage
- Using the
.query()method will send theAUXIn:VTERm:DUAL:A?query. - Using the
.verify(value)method will send theAUXIn:VTERm:DUAL:A?query and raise an AssertionError if the returned value does not matchvalue. - Using the
.write(value)method will send theAUXIn:VTERm:DUAL:A valuecommand.
SCPI Syntax
- AUXIn:VTERm:DUAL:A <NR3>
- AUXIn:VTERm:DUAL:A?
Info
<NR3>specifies the termination voltage.
AuxinVtermDualB
¶
Bases: SCPICmdWrite, SCPICmdRead
The AUXIn:VTERm:DUAL:B command.
Description
- This command sets or queries the termination voltage for probes with dual inputs that support settable termination voltage.
Usage
- Using the
.query()method will send theAUXIn:VTERm:DUAL:B?query. - Using the
.verify(value)method will send theAUXIn:VTERm:DUAL:B?query and raise an AssertionError if the returned value does not matchvalue. - Using the
.write(value)method will send theAUXIn:VTERm:DUAL:B valuecommand.
SCPI Syntax
- AUXIn:VTERm:DUAL:B <NR3>
- AUXIn:VTERm:DUAL:B?
Info
<NR3>specifies the termination voltage.