recall
¶
The recall commands module.
These commands are used in the following models: DPO5K, DPO5KB, DPO70KC, DPO70KD, DPO70KDX, DPO70KSX, DPO7K, DPO7KC, DSA70KC, DSA70KD, MSO5K, MSO5KB, MSO70KC, MSO70KDX
THIS FILE IS AUTO-GENERATED, IT SHOULD NOT BE MANUALLY MODIFIED.
Please report an issue if one is found.
Commands and Queries
- RECAll:MASK <QString>
- RECAll:SETUp {FACtory|<NR1>|<file path>}
- RECAll:SETUp:DESKew {LOCK|UNLOCK}
- RECAll:SETUp:DESKew?
- RECAll:WAVEform <file path>,REF<x>
Recall
¶
Bases: SCPICmdRead
The RECAll command tree.
Usage
- Using the
.query()method will send theRECAll?query. - Using the
.verify(value)method will send theRECAll?query and raise an AssertionError if the returned value does not matchvalue.
Properties
.mask: TheRECAll:MASKcommand..setup: TheRECAll:SETUpcommand..waveform: TheRECAll:WAVEformcommand.
mask
property
¶
mask: RecallMask
Return the RECAll:MASK command.
Description
- This command recalls the mask from a specified file that was saved to the current
working directory using the
SAVE:MASKcommand. A series of examples showing how to use mask commands for typical tasks is included in an appendix.
Usage
- Using the
.write(value)method will send theRECAll:MASK valuecommand.
SCPI Syntax
- RECAll:MASK <QString>
Info
QStringis a quoted string that is the name of the mask definition being recalled from the current working directory.
setup
property
¶
setup: RecallSetup
Return the RECAll:SETUp command.
Description
- Restores the state of the oscilloscope from a copy of the settings stored in memory.
The settings are stored using the
*SAVcommand.
Usage
- Using the
.write(value)method will send theRECAll:SETUp valuecommand.
SCPI Syntax
- RECAll:SETUp {FACtory|<NR1>|<file path>}
Info
FACtoryrestores the factory setup.<NR1>is a value in the range from 1 to 10, which specifies a saved setup storage location.<file path>specifies a location for an oscilloscope setup file.is a quoted string that defines the file name and path. Input the file path using the form :/ / . and one or s are optional. If you do not specify them, the oscilloscope will read the file from the default directory (see FILESYSTEM:CWD).stands for a filename; the use of wildcard characters in filenames is not supported. Filename extensions are not required, but highly recommended.
Sub-properties
.deskew: TheRECAll:SETUp:DESKewcommand.
waveform
property
¶
waveform: RecallWaveform
Return the RECAll:WAVEform command.
Description
- This command (no query form) recalls a stored waveform to a reference location. This command is equivalent to selecting Recall from the File menu, and then pressing the Waveform button.
Usage
- Using the
.write(value)method will send theRECAll:WAVEform valuecommand.
SCPI Syntax
- RECAll:WAVEform <file path>,REF<x>
Info
<file path>specifies a location for a stored waveform file.is a quoted string that defines the file name and path. Input the file path using the form <drive>:<dir>/. and one or more s are optional. If you do not specify them, the instrument will read the waveform from the default directory (C:UsersPublicTektronixTekScope|Waveforms). stands for a file name of up to 128 characters (use of wildcard characters in filenames is not supported). File name extensions are not required but are highly recommended. REF<x>specifies a location in internal reference memory. Reference memory location values range from 1 through 4.
RecallMask
¶
Bases: SCPICmdWrite
The RECAll:MASK command.
Description
- This command recalls the mask from a specified file that was saved to the current working
directory using the
SAVE:MASKcommand. A series of examples showing how to use mask commands for typical tasks is included in an appendix.
Usage
- Using the
.write(value)method will send theRECAll:MASK valuecommand.
SCPI Syntax
- RECAll:MASK <QString>
Info
QStringis a quoted string that is the name of the mask definition being recalled from the current working directory.
RecallSetup
¶
Bases: SCPICmdWrite, SCPICmdRead
The RECAll:SETUp command.
Description
- Restores the state of the oscilloscope from a copy of the settings stored in memory. The
settings are stored using the
*SAVcommand.
Usage
- Using the
.write(value)method will send theRECAll:SETUp valuecommand.
SCPI Syntax
- RECAll:SETUp {FACtory|<NR1>|<file path>}
Info
FACtoryrestores the factory setup.<NR1>is a value in the range from 1 to 10, which specifies a saved setup storage location.<file path>specifies a location for an oscilloscope setup file.is a quoted string that defines the file name and path. Input the file path using the form :/ / . and one or s are optional. If you do not specify them, the oscilloscope will read the file from the default directory (see FILESYSTEM:CWD).stands for a filename; the use of wildcard characters in filenames is not supported. Filename extensions are not required, but highly recommended.
Properties
.deskew: TheRECAll:SETUp:DESKewcommand.
deskew
property
¶
deskew: RecallSetupDeskew
Return the RECAll:SETUp:DESKew command.
Description
- This command sets or queries the deskew values that are affected by a default setup or a recalled setup.
Usage
- Using the
.query()method will send theRECAll:SETUp:DESKew?query. - Using the
.verify(value)method will send theRECAll:SETUp:DESKew?query and raise an AssertionError if the returned value does not matchvalue. - Using the
.write(value)method will send theRECAll:SETUp:DESKew valuecommand.
SCPI Syntax
- RECAll:SETUp:DESKew {LOCK|UNLOCK}
- RECAll:SETUp:DESKew?
Info
LOCKa default or a recall setup will not change the deskew settings when this option is selected.UNLOCKa default setup will reset the deskew settings to factory values and a recall setup will apply the setup deskew values to the recalled oscilloscope state.
RecallSetupDeskew
¶
Bases: SCPICmdWrite, SCPICmdRead
The RECAll:SETUp:DESKew command.
Description
- This command sets or queries the deskew values that are affected by a default setup or a recalled setup.
Usage
- Using the
.query()method will send theRECAll:SETUp:DESKew?query. - Using the
.verify(value)method will send theRECAll:SETUp:DESKew?query and raise an AssertionError if the returned value does not matchvalue. - Using the
.write(value)method will send theRECAll:SETUp:DESKew valuecommand.
SCPI Syntax
- RECAll:SETUp:DESKew {LOCK|UNLOCK}
- RECAll:SETUp:DESKew?
Info
LOCKa default or a recall setup will not change the deskew settings when this option is selected.UNLOCKa default setup will reset the deskew settings to factory values and a recall setup will apply the setup deskew values to the recalled oscilloscope state.
RecallWaveform
¶
Bases: SCPICmdWrite
The RECAll:WAVEform command.
Description
- This command (no query form) recalls a stored waveform to a reference location. This command is equivalent to selecting Recall from the File menu, and then pressing the Waveform button.
Usage
- Using the
.write(value)method will send theRECAll:WAVEform valuecommand.
SCPI Syntax
- RECAll:WAVEform <file path>,REF<x>
Info
<file path>specifies a location for a stored waveform file.is a quoted string that defines the file name and path. Input the file path using the form <drive>:<dir>/. and one or more s are optional. If you do not specify them, the instrument will read the waveform from the default directory (C:UsersPublicTektronixTekScope|Waveforms). stands for a file name of up to 128 characters (use of wildcard characters in filenames is not supported). File name extensions are not required but are highly recommended. REF<x>specifies a location in internal reference memory. Reference memory location values range from 1 through 4.