trigger

The trigger commands module.

These commands are used in the following models: DPO2K, DPO2KB, MSO2K, MSO2KB

THIS FILE IS AUTO-GENERATED, IT SHOULD NOT BE MANUALLY MODIFIED.

Please report an issue if one is found.

Commands and Queries
- TRIGger FORCe
- TRIGger:A SETLevel
- TRIGger:A:BUS {I2C|SPI|CAN|RS232}
- TRIGger:A:BUS:B<x>:CAN:ADDRess:MODe {STandard|EXTended}
- TRIGger:A:BUS:B<x>:CAN:ADDRess:MODe?
- TRIGger:A:BUS:B<x>:CAN:ADDRess:VALue <QString>
- TRIGger:A:BUS:B<x>:CAN:ADDRess:VALue?
- TRIGger:A:BUS:B<x>:CAN:CONDition {SOF|FRAMEtype|IDentifier|DATA|IDANDDATA|EOF|ACKMISS}
- TRIGger:A:BUS:B<x>:CAN:CONDition?
- TRIGger:A:BUS:B<x>:CAN:DATa:DIRection {READ|WRITE|NOCARE}
- TRIGger:A:BUS:B<x>:CAN:DATa:DIRection?
- TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier {LESSThan|MOREThan|EQUal|UNEQual|LESSEQual|MOREEQual}
- TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier?
- TRIGger:A:BUS:B<x>:CAN:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:CAN:DATa:SIZe?
- TRIGger:A:BUS:B<x>:CAN:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:CAN:DATa:VALue?
- TRIGger:A:BUS:B<x>:CAN:FRAMEtype {DATA|REMote|ERRor|OVERLoad}
- TRIGger:A:BUS:B<x>:CAN:FRAMEtype?
- TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe {STandard|EXTended}
- TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe?
- TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue <QString>
- TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue?
- TRIGger:A:BUS:B<x>:FLEXray:CONDition {SOF|FRAMEType|IDentifier|CYCLEcount|HEADer|DATA|IDANDDATA|EOF|ERROR}
- TRIGger:A:BUS:B<x>:FLEXray:CONDition?
- TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:HIVALue <QString>
- TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:HIVALue?
- TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:QUALifier {LESSThan|MOREThan|EQUal|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:QUALifier?
- TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:VALue <QString>
- TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:VALue?
- TRIGger:A:BUS:B<x>:FLEXray:DATa:HIVALue <QString>
- TRIGger:A:BUS:B<x>:FLEXray:DATa:HIVALue?
- TRIGger:A:BUS:B<x>:FLEXray:DATa:OFFSet <NR1>
- TRIGger:A:BUS:B<x>:FLEXray:DATa:OFFSet?
- TRIGger:A:BUS:B<x>:FLEXray:DATa:QUALifier {LESSThan|MOREThan|EQUal|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:FLEXray:DATa:QUALifier?
- TRIGger:A:BUS:B<x>:FLEXray:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:FLEXray:DATa:SIZe?
- TRIGger:A:BUS:B<x>:FLEXray:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:FLEXray:DATa:VALue?
- TRIGger:A:BUS:B<x>:FLEXray:EOFTYPE {STATic|DYNAMic|ANY}
- TRIGger:A:BUS:B<x>:FLEXray:EOFTYPE?
- TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE {CRCHeader|CRCTrailer|SYNCFrame|STARTupnosync|NULLFRStatic|NULLFRDynamic}
- TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE?
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIVALue <QString>
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIVALue?
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:QUALifier {LESSThan|MOREThan|EQUal|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:QUALifier?
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VALue <QString>
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VALue?
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEType {NORMal|PAYLoad|NULL|SYNC|STARTup}
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEType?
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:CRC <QString>
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:CRC?
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:CYCLEcount <QString>
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:CYCLEcount?
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:FRAMEID <QString>
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:FRAMEID?
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:INDBits <QString>
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:INDBits?
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:PAYLength <QString>
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:PAYLength?
- TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe {ADDR7|ADDR10}
- TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe?
- TRIGger:A:BUS:B<x>:I2C:ADDRess:TYPe {GENeralcall|STARtbyte|HSmode|EEPROM|USER}
- TRIGger:A:BUS:B<x>:I2C:ADDRess:TYPe?
- TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue <QString>
- TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue?
- TRIGger:A:BUS:B<x>:I2C:CONDition {STARt|STOP|REPEATstart|ACKMISS|ADDRess|DATA|ADDRANDDATA}
- TRIGger:A:BUS:B<x>:I2C:CONDition?
- TRIGger:A:BUS:B<x>:I2C:DATa:DIRection {READ|WRITE|NOCARE}
- TRIGger:A:BUS:B<x>:I2C:DATa:DIRection?
- TRIGger:A:BUS:B<x>:I2C:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:I2C:DATa:SIZe?
- TRIGger:A:BUS:B<x>:I2C:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:I2C:DATa:VALue?
- TRIGger:A:BUS:B<x>:LIN:CONDition {SYNCField|IDentifier|DATA|IDANDDATA|WAKEup|SLEEP|ERROR}
- TRIGger:A:BUS:B<x>:LIN:CONDition?
- TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue <QString>
- TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue?
- TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier {LESSThan|MOREThan|EQUal|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier?
- TRIGger:A:BUS:B<x>:LIN:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:LIN:DATa:SIZe?
- TRIGger:A:BUS:B<x>:LIN:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:LIN:DATa:VALue?
- TRIGger:A:BUS:B<x>:LIN:ERRTYPE {SYNC|PARity|CHecksum}
- TRIGger:A:BUS:B<x>:LIN:ERRTYPE?
- TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue <QString>
- TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue?
- TRIGger:A:BUS:B<x>:PARallel:VALue <QString>
- TRIGger:A:BUS:B<x>:PARallel:VALue?
- TRIGger:A:BUS:B<x>:RS232C:CONDition {RXSTArt|RXDATA|RXENDPacket|RXPARity|TXSTArt|TXDATA|TXENDPacket|TXPARity|}
- TRIGger:A:BUS:B<x>:RS232C:CONDition?
- TRIGger:A:BUS:B<x>:RS232C:RX:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:RS232C:RX:DATa:SIZe?
- TRIGger:A:BUS:B<x>:RS232C:RX:DATa:VALue
- TRIGger:A:BUS:B<x>:RS232C:RX:DATa:VALue?
- TRIGger:A:BUS:B<x>:RS232C:TX:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:RS232C:TX:DATa:SIZe?
- TRIGger:A:BUS:B<x>:RS232C:TX:DATa:VALue
- TRIGger:A:BUS:B<x>:RS232C:TX:DATa:VALue?
- TRIGger:A:BUS:B<x>:SPI:CONDition {SS|STARTofframe|MISO|MOSI|MISOMOSI}
- TRIGger:A:BUS:B<x>:SPI:CONDition?
- TRIGger:A:BUS:B<x>:SPI:DATa:IN:VALue <QString>
- TRIGger:A:BUS:B<x>:SPI:DATa:IN:VALue?
- TRIGger:A:BUS:B<x>:SPI:DATa:MISO:VALue <QString>
- TRIGger:A:BUS:B<x>:SPI:DATa:MISO:VALue?
- TRIGger:A:BUS:B<x>:SPI:DATa:MOSI:VALue <QString>
- TRIGger:A:BUS:B<x>:SPI:DATa:MOSI:VALue?
- TRIGger:A:BUS:B<x>:SPI:DATa:OUT:VALue <QString>
- TRIGger:A:BUS:B<x>:SPI:DATa:OUT:VALue?
- TRIGger:A:BUS:B<x>:SPI:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:SPI:DATa:SIZe?
- TRIGger:A:BUS:SOUrce {B<x>}
- TRIGger:A:BUS:SOUrce?
- TRIGger:A:BUS?
- TRIGger:A:EDGE:COUPling {DC|HFRej|LFRej|NOISErej}
- TRIGger:A:EDGE:COUPling?
- TRIGger:A:EDGE:SLOpe {RISe|FALL}
- TRIGger:A:EDGE:SLOpe?
- TRIGger:A:EDGE:SOUrce {CH<x>|D<x>|EXT|LINE|AUX}
- TRIGger:A:EDGE:SOUrce?
- TRIGger:A:EDGE?
- TRIGger:A:HOLDoff:TIMe <NR3>
- TRIGger:A:HOLDoff:TIMe?
- TRIGger:A:HOLDoff?
- TRIGger:A:LEVel {ECL|TTL|<NR3>}
- TRIGger:A:LEVel:AUXin {<NR3>|ECL|TTL}
- TRIGger:A:LEVel:AUXin?
- TRIGger:A:LEVel:CH<x> {<NR3>|TTL|ECL}
- TRIGger:A:LEVel:CH<x>?
- TRIGger:A:LEVel:D<x> {<NR3>|ECL|TTL}
- TRIGger:A:LEVel:D<x>?
- TRIGger:A:LEVel?
- TRIGger:A:LOGIc:CLAss {LOGIC|SETHold}
- TRIGger:A:LOGIc:CLAss?
- TRIGger:A:LOGIc:FUNCtion {AND|NANd}
- TRIGger:A:LOGIc:FUNCtion?
- TRIGger:A:LOGIc:INPut:CH<x> {HIGH|LOW|X}
- TRIGger:A:LOGIc:INPut:CH<x>?
- TRIGger:A:LOGIc:INPut:CLOCk:EDGE {FALL|RISe|EITher}
- TRIGger:A:LOGIc:INPut:CLOCk:EDGE?
- TRIGger:A:LOGIc:INPut:CLOCk:SOUrce {CH<x>|D<x>|NONE}
- TRIGger:A:LOGIc:INPut:CLOCk:SOUrce?
- TRIGger:A:LOGIc:INPut:D<x> {HIGH|LOW|X}
- TRIGger:A:LOGIc:INPut:D<x>?
- TRIGger:A:LOGIc:INPut?
- TRIGger:A:LOGIc:PATtern:DELTatime <NR3>
- TRIGger:A:LOGIc:PATtern:DELTatime?
- TRIGger:A:LOGIc:PATtern:INPut:D<x> {HIGH|LOW|X}
- TRIGger:A:LOGIc:PATtern:INPut:D<x>?
- TRIGger:A:LOGIc:PATtern:WHEn {TRUe|FALSe|LESSThan|MOREThan|EQUal|UNEQual}
- TRIGger:A:LOGIc:PATtern:WHEn:LESSLimit <NR3>
- TRIGger:A:LOGIc:PATtern:WHEn:LESSLimit?
- TRIGger:A:LOGIc:PATtern:WHEn:MORELimit <NR3>
- TRIGger:A:LOGIc:PATtern:WHEn:MORELimit?
- TRIGger:A:LOGIc:PATtern:WHEn?
- TRIGger:A:LOGIc:PATtern?
- TRIGger:A:LOGIc:THReshold:CH<x> {<NR3>|ECL|TTL}
- TRIGger:A:LOGIc:THReshold:CH<x>?
- TRIGger:A:LOGIc:THReshold:D<x> {<NR3>|ECL|TTL}
- TRIGger:A:LOGIc:THReshold:D<x>?
- TRIGger:A:LOGIc?
- TRIGger:A:LOWerthreshold:AUX {<NR3>|ECL|TTL}
- TRIGger:A:LOWerthreshold:AUX?
- TRIGger:A:LOWerthreshold:CH<x> {ECL|TTL|<NR3>}
- TRIGger:A:LOWerthreshold:CH<x>?
- TRIGger:A:LOWerthreshold:EXT {<NR3>|ECL|TTL}
- TRIGger:A:LOWerthreshold:EXT?
- TRIGger:A:MODe {AUTO|NORMal}
- TRIGger:A:MODe?
- TRIGger:A:PULSEWidth:POLarity {NEGative|POSitive}
- TRIGger:A:PULSEWidth:POLarity?
- TRIGger:A:PULSEWidth:SOUrce {CH<x>|D<x>|LINE|EXT}
- TRIGger:A:PULSEWidth:SOUrce?
- TRIGger:A:PULSEWidth:WHEn {LESSthan|MOREthan|EQual|UNEQual}
- TRIGger:A:PULSEWidth:WHEn?
- TRIGger:A:PULSEWidth:Width <NR3>
- TRIGger:A:PULSEWidth:Width?
- TRIGger:A:PULSEWidth?
- TRIGger:A:PULse:CLAss {RUNt|WIDth|TRANsition}
- TRIGger:A:PULse:CLAss?
- TRIGger:A:PULse?
- TRIGger:A:RISEFall:DELTatime <NR3>
- TRIGger:A:RISEFall:DELTatime?
- TRIGger:A:RISEFall:POLarity {EITher|NEGative|POSitive}
- TRIGger:A:RISEFall:POLarity?
- TRIGger:A:RISEFall:SOUrce {CH<x>|D<x>}
- TRIGger:A:RISEFall:SOUrce?
- TRIGger:A:RISEFall:WHEn {SLOWer|FASTer|EQual|UNEQual}
- TRIGger:A:RISEFall:WHEn?
- TRIGger:A:RISEFall?
- TRIGger:A:RUNT:POLarity {EITher|NEGative|POSitive}
- TRIGger:A:RUNT:POLarity?
- TRIGger:A:RUNT:SOUrce {CH<x>}
- TRIGger:A:RUNT:SOUrce?
- TRIGger:A:RUNT:WHEn {LESSthan|MOREthan|EQual|UNEQual|OCCURS}
- TRIGger:A:RUNT:WHEn?
- TRIGger:A:RUNT:WIDth <NR3>
- TRIGger:A:RUNT:WIDth?
- TRIGger:A:RUNT?
- TRIGger:A:SETHold:CLOCk:EDGE {FALL|RISe}
- TRIGger:A:SETHold:CLOCk:EDGE?
- TRIGger:A:SETHold:CLOCk:SOUrce {CH<x>|D<x>}
- TRIGger:A:SETHold:CLOCk:SOUrce?
- TRIGger:A:SETHold:CLOCk:THReshold {<NR3>|TTL|ECL}
- TRIGger:A:SETHold:CLOCk:THReshold?
- TRIGger:A:SETHold:CLOCk?
- TRIGger:A:SETHold:DATa:SOUrce DPO Models:{CH<x>|D<x>}
- TRIGger:A:SETHold:DATa:SOUrce?
- TRIGger:A:SETHold:DATa:THReshold {<NR3>|TTL|ECL}
- TRIGger:A:SETHold:DATa:THReshold?
- TRIGger:A:SETHold:DATa?
- TRIGger:A:SETHold:HOLDTime <NR3>
- TRIGger:A:SETHold:HOLDTime?
- TRIGger:A:SETHold:SETTime <NR3>
- TRIGger:A:SETHold:SETTime?
- TRIGger:A:SETHold:THReshold:CH<x> {<NR3>|ECL|TTL}
- TRIGger:A:SETHold:THReshold:CH<x>?
- TRIGger:A:SETHold:THReshold:D<x> {<NR3>|ECL|TTL}
- TRIGger:A:SETHold:THReshold:D<x>?
- TRIGger:A:SETHold?
- TRIGger:A:TRANsition:DELTatime <NR3>
- TRIGger:A:TRANsition:DELTatime?
- TRIGger:A:TRANsition:POLarity {EITher|NEGative|POSitive}
- TRIGger:A:TRANsition:POLarity?
- TRIGger:A:TRANsition:SOUrce {CH<x>|D<x>}
- TRIGger:A:TRANsition:SOUrce?
- TRIGger:A:TRANsition:WHEn {SLOWer|FASTer|EQual|UNEQual}
- TRIGger:A:TRANsition:WHEn?
- TRIGger:A:TRANsition?
- TRIGger:A:TYPe {EDGe|LOGic|PULSe|BUS|VIDeo}
- TRIGger:A:TYPe?
- TRIGger:A:UPPerthreshold:CH<x> {<NR3>|ECL|TTL}
- TRIGger:A:UPPerthreshold:CH<x>?
- TRIGger:A:VIDeo:CUSTom:FORMat {INTERLAced|PROGressive}
- TRIGger:A:VIDeo:CUSTom:FORMat?
- TRIGger:A:VIDeo:CUSTom:LINEPeriod <NR3>
- TRIGger:A:VIDeo:CUSTom:LINEPeriod?
- TRIGger:A:VIDeo:CUSTom:SCAN {RATE15K|RATE20K|RATE25K|RATE35K|RATE50K}
- TRIGger:A:VIDeo:CUSTom:SCAN?
- TRIGger:A:VIDeo:CUSTom:SYNCInterval <NR3>
- TRIGger:A:VIDeo:CUSTom:SYNCInterval?
- TRIGger:A:VIDeo:CUSTom:TYPE {INTERLAced|PROGressive}
- TRIGger:A:VIDeo:CUSTom:TYPE?
- TRIGger:A:VIDeo:CUSTom?
- TRIGger:A:VIDeo:FIELD {ODD|EVEN|ALLFields|ALLLines|NUMERic}
- TRIGger:A:VIDeo:FIELD?
- TRIGger:A:VIDeo:HDtv:FORMat {HD1080P24|HD720P60|HD480P60|HD1080I50|HD1080P25|HD1080I60|HD1080PSF24}
- TRIGger:A:VIDeo:HDtv:FORMat?
- TRIGger:A:VIDeo:HOLDoff:FIELD <NR3>
- TRIGger:A:VIDeo:HOLDoff:FIELD?
- TRIGger:A:VIDeo:LINE <NR1>
- TRIGger:A:VIDeo:LINE?
- TRIGger:A:VIDeo:POLarity {NEGative|POSitive|NORMal|INVERTed}
- TRIGger:A:VIDeo:POLarity?
- TRIGger:A:VIDeo:SOUrce {CH<x>}
- TRIGger:A:VIDeo:SOUrce?
- TRIGger:A:VIDeo:STANdard {NTSc|PAL|SECAM}
- TRIGger:A:VIDeo:STANdard?
- TRIGger:A:VIDeo:SYNC {ODD|EVEN|ALLFields|ALLLines|NUMERic}
- TRIGger:A:VIDeo:SYNC?
- TRIGger:A:VIDeo?
- TRIGger:A?
- TRIGger:B:LEVel:D<x> {ECL|TTL|<NR3>}
- TRIGger:B:LEVel:D<x>?
- TRIGger:B:LOWerthreshold:D<x> {<NR3>|ECL|TTL}
- TRIGger:B:LOWerthreshold:D<x>?
- TRIGger:EXTernal:PRObe <NR3>
- TRIGger:EXTernal:PRObe?
- TRIGger:EXTernal:YUNIts?
- TRIGger:EXTernal?
- TRIGger:FREQuency?
- TRIGger:STATE?
- TRIGger?

Trigger

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger command.

Description
  • This command forces a trigger event to occur. The query returns the current trigger parameters for the instrument.
Usage
  • Using the .query() method will send the TRIGger? query.
  • Using the .verify(value) method will send the TRIGger? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger value command.
SCPI Syntax
- TRIGger FORCe
- TRIGger?
Info
  • FORCe creates a trigger event. If TRIGger:STATE is set to READy, the acquisition will complete. Otherwise, this command will be ignored. This is equivalent to pressing the Force button on the front panel.
Properties
  • .a: The TRIGger:A command.
  • .b: The TRIGger:B command tree.
  • .external: The TRIGger:EXTernal command.
  • .frequency: The TRIGger:FREQuency command.
  • .state: The TRIGger:STATE command.

a property

Return the TRIGger:A command.

Description
  • This command sets the A trigger level automatically to 50% of the range of the minimum and maximum values of the trigger input signal. The query returns current trigger parameters. The trigger level is the voltage threshold through which the trigger source signal must pass to generate a trigger event. This command is equivalent to pushing the LEVEL knob on the front panel.
Usage
  • Using the .query() method will send the TRIGger:A? query.
  • Using the .verify(value) method will send the TRIGger:A? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A value command.
SCPI Syntax
- TRIGger:A SETLevel
- TRIGger:A?
Info
  • SETLevel sets the trigger level to 50% of the range of the minimum and maximum values of the trigger input signal.
Sub-properties
  • .bus: The TRIGger:A:BUS command.
  • .edge: The TRIGger:A:EDGE command.
  • .holdoff: The TRIGger:A:HOLDoff command.
  • .level: The TRIGger:A:LEVel command.
  • .logic: The TRIGger:A:LOGIc command.
  • .lowerthreshold: The TRIGger:A:LOWerthreshold command tree.
  • .mode: The TRIGger:A:MODe command.
  • .pulsewidth: The TRIGger:A:PULSEWidth command.
  • .pulse: The TRIGger:A:PULse command.
  • .runt: The TRIGger:A:RUNT command.
  • .sethold: The TRIGger:A:SETHold command.
  • .type: The TRIGger:A:TYPe command.
  • .upperthreshold: The TRIGger:A:UPPerthreshold command tree.
  • .video: The TRIGger:A:VIDeo command.
  • .transition: The TRIGger:A:TRANsition command.
  • .risefall: The TRIGger:A:RISEFall command.

b property

Return the TRIGger:B command tree.

Usage
  • Using the .query() method will send the TRIGger:B? query.
  • Using the .verify(value) method will send the TRIGger:B? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .level: The TRIGger:B:LEVel command tree.
  • .lowerthreshold: The TRIGger:B:LOWerthreshold command tree.

external property

external: TriggerExternal

Return the TRIGger:EXTernal command.

Description
  • Returns all external trigger-related parameters for the probe attached to the Aux Input connector.
Usage
  • Using the .query() method will send the TRIGger:EXTernal? query.
  • Using the .verify(value) method will send the TRIGger:EXTernal? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:EXTernal?
Sub-properties
  • .probe: The TRIGger:EXTernal:PRObe command.
  • .yunits: The TRIGger:EXTernal:YUNIts command.

frequency property

frequency: TriggerFrequency

Return the TRIGger:FREQuency command.

Description
  • Returns the trigger frequency in hertz if available. If the trigger frequency is not currently available, the IEEE Not A Number (NaN = 99.10E+36) value is returned. The maximum precision of the returned frequency is 12 digits. Use the DISPLAY:TRIGFREQUENCY command to enable/disable the calculation of the trigger frequency.
Usage
  • Using the .query() method will send the TRIGger:FREQuency? query.
  • Using the .verify(value) method will send the TRIGger:FREQuency? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:FREQuency?

state property

state: TriggerState

Return the TRIGger:STATE command.

Description
  • This query-only command returns the current state of the triggering system.
Usage
  • Using the .query() method will send the TRIGger:STATE? query.
  • Using the .verify(value) method will send the TRIGger:STATE? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:STATE?

TriggerA

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A command.

Description
  • This command sets the A trigger level automatically to 50% of the range of the minimum and maximum values of the trigger input signal. The query returns current trigger parameters. The trigger level is the voltage threshold through which the trigger source signal must pass to generate a trigger event. This command is equivalent to pushing the LEVEL knob on the front panel.
Usage
  • Using the .query() method will send the TRIGger:A? query.
  • Using the .verify(value) method will send the TRIGger:A? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A value command.
SCPI Syntax
- TRIGger:A SETLevel
- TRIGger:A?
Info
  • SETLevel sets the trigger level to 50% of the range of the minimum and maximum values of the trigger input signal.
Properties
  • .bus: The TRIGger:A:BUS command.
  • .edge: The TRIGger:A:EDGE command.
  • .holdoff: The TRIGger:A:HOLDoff command.
  • .level: The TRIGger:A:LEVel command.
  • .logic: The TRIGger:A:LOGIc command.
  • .lowerthreshold: The TRIGger:A:LOWerthreshold command tree.
  • .mode: The TRIGger:A:MODe command.
  • .pulsewidth: The TRIGger:A:PULSEWidth command.
  • .pulse: The TRIGger:A:PULse command.
  • .runt: The TRIGger:A:RUNT command.
  • .sethold: The TRIGger:A:SETHold command.
  • .type: The TRIGger:A:TYPe command.
  • .upperthreshold: The TRIGger:A:UPPerthreshold command tree.
  • .video: The TRIGger:A:VIDeo command.
  • .transition: The TRIGger:A:TRANsition command.
  • .risefall: The TRIGger:A:RISEFall command.

bus property

Return the TRIGger:A:BUS command.

Description
  • Sets or returns the trigger type: I2C, CAN, SPI, and RS232. There are up to two serial buses, B1, B2, depending on your instrument model. Each can be independently set to one of the serial trigger types. The serial parameters related to the trigger are broken into two sections: Trigger:A:SERIAL xxx, consisting of parameters the user will change frequently, and BUS:B1:xxx, consisting of parameters the user will specify once (bus definition).
Usage
  • Using the .query() method will send the TRIGger:A:BUS? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS value command.
SCPI Syntax
- TRIGger:A:BUS {I2C|SPI|CAN|RS232}
- TRIGger:A:BUS?
Info
  • I2C specifies the Inter-IC bus.
  • SPI specifies the Serial Peripheral Interface bus.
  • CAN specifies the Controller Area Network bus.
Sub-properties
  • .b: The TRIGger:A:BUS:B<x> command tree.
  • .source: The TRIGger:A:BUS:SOUrce command.

edge property

Return the TRIGger:A:EDGE command.

Description
  • Returns the trigger source, coupling, and slope for the A edge trigger.
Usage
  • Using the .query() method will send the TRIGger:A:EDGE? query.
  • Using the .verify(value) method will send the TRIGger:A:EDGE? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:EDGE?
Sub-properties
  • .coupling: The TRIGger:A:EDGE:COUPling command.
  • .slope: The TRIGger:A:EDGE:SLOpe command.
  • .source: The TRIGger:A:EDGE:SOUrce command.

holdoff property

holdoff: TriggerAHoldoff

Return the TRIGger:A:HOLDoff command.

Description
  • Returns the A trigger holdoff parameters. These parameters specify the time period during which the trigger circuitry is not looking to generate a trigger event.
Usage
  • Using the .query() method will send the TRIGger:A:HOLDoff? query.
  • Using the .verify(value) method will send the TRIGger:A:HOLDoff? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:HOLDoff?
Sub-properties
  • .time: The TRIGger:A:HOLDoff:TIMe command.

level property

Return the TRIGger:A:LEVel command.

Description
  • Sets or returns the trigger level for the A trigger.
Usage
  • Using the .query() method will send the TRIGger:A:LEVel? query.
  • Using the .verify(value) method will send the TRIGger:A:LEVel? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LEVel value command.
SCPI Syntax
- TRIGger:A:LEVel {ECL|TTL|<NR3>}
- TRIGger:A:LEVel?
Info
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.
  • <NR3> specifies the trigger level in user units (usually volts).
Sub-properties
  • .auxin: The TRIGger:A:LEVel:AUXin command.
  • .ch: The TRIGger:A:LEVel:CH<x> command.
  • .d: The TRIGger:A:LEVel:D<x> command.

logic property

Return the TRIGger:A:LOGIc command.

Description
  • Returns all of the A logic trigger parameters.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:LOGIc?
Sub-properties
  • .class: The TRIGger:A:LOGIc:CLAss command.
  • .function: The TRIGger:A:LOGIc:FUNCtion command.
  • .input: The TRIGger:A:LOGIc:INPut command.
  • .pattern: The TRIGger:A:LOGIc:PATtern command.
  • .threshold: The TRIGger:A:LOGIc:THReshold command tree.

lowerthreshold property

lowerthreshold: TriggerALowerthreshold

Return the TRIGger:A:LOWerthreshold command tree.

Usage
  • Using the .query() method will send the TRIGger:A:LOWerthreshold? query.
  • Using the .verify(value) method will send the TRIGger:A:LOWerthreshold? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .ch: The TRIGger:A:LOWerthreshold:CH<x> command.
  • .ext: The TRIGger:A:LOWerthreshold:EXT command.
  • .aux: The TRIGger:A:LOWerthreshold:AUX command.

mode property

Return the TRIGger:A:MODe command.

Description
  • This command sets or queries the A trigger mode. This command is equivalent to pushing the Mode button on the front panel.
Usage
  • Using the .query() method will send the TRIGger:A:MODe? query.
  • Using the .verify(value) method will send the TRIGger:A:MODe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:MODe value command.
SCPI Syntax
- TRIGger:A:MODe {AUTO|NORMal}
- TRIGger:A:MODe?
Info
  • AUTO generates a trigger if one is not detected within a specified time period.
  • NORMal waits for a valid trigger event.

pulse property

Return the TRIGger:A:PULse command.

Description
  • Returns the A pulse trigger parameters.
Usage
  • Using the .query() method will send the TRIGger:A:PULse? query.
  • Using the .verify(value) method will send the TRIGger:A:PULse? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:PULse?
Sub-properties
  • .class: The TRIGger:A:PULse:CLAss command.

pulsewidth property

pulsewidth: TriggerAPulsewidth

Return the TRIGger:A:PULSEWidth command.

Description
  • Returns the width parameters for the pulse width trigger.
Usage
  • Using the .query() method will send the TRIGger:A:PULSEWidth? query.
  • Using the .verify(value) method will send the TRIGger:A:PULSEWidth? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:PULSEWidth?
Sub-properties
  • .polarity: The TRIGger:A:PULSEWidth:POLarity command.
  • .source: The TRIGger:A:PULSEWidth:SOUrce command.
  • .when: The TRIGger:A:PULSEWidth:WHEn command.
  • .width: The TRIGger:A:PULSEWidth:Width command.

risefall property

risefall: TriggerARisefall

Return the TRIGger:A:RISEFall command.

Description
  • Returns transition time trigger parameters.
Usage
  • Using the .query() method will send the TRIGger:A:RISEFall? query.
  • Using the .verify(value) method will send the TRIGger:A:RISEFall? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:RISEFall?
Sub-properties
  • .deltatime: The TRIGger:A:RISEFall:DELTatime command.
  • .polarity: The TRIGger:A:RISEFall:POLarity command.
  • .source: The TRIGger:A:RISEFall:SOUrce command.
  • .when: The TRIGger:A:RISEFall:WHEn command.

runt property

Return the TRIGger:A:RUNT command.

Description
  • Returns the current A runt trigger parameters.
Usage
  • Using the .query() method will send the TRIGger:A:RUNT? query.
  • Using the .verify(value) method will send the TRIGger:A:RUNT? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:RUNT?
Sub-properties
  • .polarity: The TRIGger:A:RUNT:POLarity command.
  • .source: The TRIGger:A:RUNT:SOUrce command.
  • .when: The TRIGger:A:RUNT:WHEn command.
  • .width: The TRIGger:A:RUNT:WIDth command.

sethold property

sethold: TriggerASethold

Return the TRIGger:A:SETHold command.

Description
  • Returns the clock edge polarity, voltage threshold and source input; data voltage threshold and source; and both setup and hold times for setup and hold violation triggering.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:SETHold?
Sub-properties
  • .clock: The TRIGger:A:SETHold:CLOCk command.
  • .data: The TRIGger:A:SETHold:DATa command.
  • .holdtime: The TRIGger:A:SETHold:HOLDTime command.
  • .settime: The TRIGger:A:SETHold:SETTime command.
  • .threshold: The TRIGger:A:SETHold:THReshold command tree.

transition property

transition: TriggerATransition

Return the TRIGger:A:TRANsition command.

Description
  • Returns transition time trigger parameters.
Usage
  • Using the .query() method will send the TRIGger:A:TRANsition? query.
  • Using the .verify(value) method will send the TRIGger:A:TRANsition? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:TRANsition?
Sub-properties
  • .deltatime: The TRIGger:A:TRANsition:DELTatime command.
  • .polarity: The TRIGger:A:TRANsition:POLarity command.
  • .source: The TRIGger:A:TRANsition:SOUrce command.
  • .when: The TRIGger:A:TRANsition:WHEn command.

type property

Return the TRIGger:A:TYPe command.

Description
  • Sets or returns the type of A trigger. The five types of triggers are of Edge, Logic, Pulse, Serial, and Video. Logic and Pulse triggers contain classes. Logic triggers consist of State, Pattern, and SetHold classes; Pulse triggers consist of Runt, Width, and Transition logic classes. Once you have set the trigger type, you may also need to identify the associated trigger class. For details on selecting Logic and Pulse trigger classes, see TRIGGER:A:LOGIC:CLASS and TRIGGER:A:PULSE:CLASS respectively.
Usage
  • Using the .query() method will send the TRIGger:A:TYPe? query.
  • Using the .verify(value) method will send the TRIGger:A:TYPe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:TYPe value command.
SCPI Syntax
- TRIGger:A:TYPe {EDGe|LOGic|PULSe|BUS|VIDeo}
- TRIGger:A:TYPe?
Info
  • EDGe is a normal trigger. A trigger event occurs when a signal passes through a specified voltage level in a specified direction and is controlled by the TRIGGER:A:EDGE commands.
  • LOGic specifies that a trigger occurs when specified conditions are met and is controlled by the TRIGGER:A:LOGIC commands.
  • PULSe specifies that a trigger occurs when a specified pulse is found and is controlled by the TRIGGER:A:PULSE commands.
  • BUS specifies that a trigger occurs when a communications signal is found. Supports CAN, I2C, SPI, and RS232 communications signals.
  • VIDeo specifies that the trigger occurs when a video signal is found.

upperthreshold property

upperthreshold: TriggerAUpperthreshold

Return the TRIGger:A:UPPerthreshold command tree.

Usage
  • Using the .query() method will send the TRIGger:A:UPPerthreshold? query.
  • Using the .verify(value) method will send the TRIGger:A:UPPerthreshold? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .ch: The TRIGger:A:UPPerthreshold:CH<x> command.

video property

Return the TRIGger:A:VIDeo command.

Description
  • Returns the A trigger video parameters.
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:VIDeo?
Sub-properties
  • .custom: The TRIGger:A:VIDeo:CUSTom command.
  • .hdtv: The TRIGger:A:VIDeo:HDtv command tree.
  • .holdoff: The TRIGger:A:VIDeo:HOLDoff command tree.
  • .line: The TRIGger:A:VIDeo:LINE command.
  • .polarity: The TRIGger:A:VIDeo:POLarity command.
  • .source: The TRIGger:A:VIDeo:SOUrce command.
  • .standard: The TRIGger:A:VIDeo:STANdard command.
  • .sync: The TRIGger:A:VIDeo:SYNC command.
  • .field: The TRIGger:A:VIDeo:FIELD command.

TriggerABus

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS command.

Description
  • Sets or returns the trigger type: I2C, CAN, SPI, and RS232. There are up to two serial buses, B1, B2, depending on your instrument model. Each can be independently set to one of the serial trigger types. The serial parameters related to the trigger are broken into two sections: Trigger:A:SERIAL xxx, consisting of parameters the user will change frequently, and BUS:B1:xxx, consisting of parameters the user will specify once (bus definition).
Usage
  • Using the .query() method will send the TRIGger:A:BUS? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS value command.
SCPI Syntax
- TRIGger:A:BUS {I2C|SPI|CAN|RS232}
- TRIGger:A:BUS?
Info
  • I2C specifies the Inter-IC bus.
  • SPI specifies the Serial Peripheral Interface bus.
  • CAN specifies the Controller Area Network bus.
Properties
  • .b: The TRIGger:A:BUS:B<x> command tree.
  • .source: The TRIGger:A:BUS:SOUrce command.

b property

Return the TRIGger:A:BUS:B<x> command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .can: The TRIGger:A:BUS:B<x>:CAN command tree.
  • .flexray: The TRIGger:A:BUS:B<x>:FLEXray command tree.
  • .i2c: The TRIGger:A:BUS:B<x>:I2C command tree.
  • .lin: The TRIGger:A:BUS:B<x>:LIN command tree.
  • .parallel: The TRIGger:A:BUS:B<x>:PARallel command tree.
  • .rs232c: The TRIGger:A:BUS:B<x>:RS232C command tree.
  • .spi: The TRIGger:A:BUS:B<x>:SPI command tree.

source property

Return the TRIGger:A:BUS:SOUrce command.

Description
  • This command specifies the source for a serial or parallel bus trigger, with the appropriate application module installed.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:SOUrce value command.
SCPI Syntax
- TRIGger:A:BUS:SOUrce {B<x>}
- TRIGger:A:BUS:SOUrce?
Info
  • B1 specifies the Bus 1 source.
  • B2 specifies the Bus 2 source.
  • B3 specifies the Bus 3 source.
  • B4 specifies the Bus 4 source.

TriggerABusBItem

Bases: ValidatedDynamicNumberCmd, SCPICmdRead

The TRIGger:A:BUS:B<x> command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>? query and raise an AssertionError if the returned value does not match value.
Properties
  • .can: The TRIGger:A:BUS:B<x>:CAN command tree.
  • .flexray: The TRIGger:A:BUS:B<x>:FLEXray command tree.
  • .i2c: The TRIGger:A:BUS:B<x>:I2C command tree.
  • .lin: The TRIGger:A:BUS:B<x>:LIN command tree.
  • .parallel: The TRIGger:A:BUS:B<x>:PARallel command tree.
  • .rs232c: The TRIGger:A:BUS:B<x>:RS232C command tree.
  • .spi: The TRIGger:A:BUS:B<x>:SPI command tree.

can property

Return the TRIGger:A:BUS:B<x>:CAN command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .condition: The TRIGger:A:BUS:B<x>:CAN:CONDition command.
  • .data: The TRIGger:A:BUS:B<x>:CAN:DATa command tree.
  • .frametype: The TRIGger:A:BUS:B<x>:CAN:FRAMEtype command.
  • .identifier: The TRIGger:A:BUS:B<x>:CAN:IDentifier command tree.
  • .address: The TRIGger:A:BUS:B<x>:CAN:ADDRess command tree.

flexray property

Return the TRIGger:A:BUS:B<x>:FLEXray command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .condition: The TRIGger:A:BUS:B<x>:FLEXray:CONDition command.
  • .cyclecount: The TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount command tree.
  • .data: The TRIGger:A:BUS:B<x>:FLEXray:DATa command tree.
  • .eoftype: The TRIGger:A:BUS:B<x>:FLEXray:EOFTYPE command.
  • .errtype: The TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE command.
  • .frameid: The TRIGger:A:BUS:B<x>:FLEXray:FRAMEID command tree.
  • .frametype: The TRIGger:A:BUS:B<x>:FLEXray:FRAMEType command.
  • .header: The TRIGger:A:BUS:B<x>:FLEXray:HEADER command tree.

i2c property

Return the TRIGger:A:BUS:B<x>:I2C command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .address: The TRIGger:A:BUS:B<x>:I2C:ADDRess command tree.
  • .condition: The TRIGger:A:BUS:B<x>:I2C:CONDition command.
  • .data: The TRIGger:A:BUS:B<x>:I2C:DATa command tree.

lin property

Return the TRIGger:A:BUS:B<x>:LIN command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .condition: The TRIGger:A:BUS:B<x>:LIN:CONDition command.
  • .data: The TRIGger:A:BUS:B<x>:LIN:DATa command tree.
  • .errtype: The TRIGger:A:BUS:B<x>:LIN:ERRTYPE command.
  • .identifier: The TRIGger:A:BUS:B<x>:LIN:IDentifier command tree.

parallel property

Return the TRIGger:A:BUS:B<x>:PARallel command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:PARallel? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:PARallel? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .value: The TRIGger:A:BUS:B<x>:PARallel:VALue command.

rs232c property

Return the TRIGger:A:BUS:B<x>:RS232C command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .condition: The TRIGger:A:BUS:B<x>:RS232C:CONDition command.
  • .rx: The TRIGger:A:BUS:B<x>:RS232C:RX command tree.
  • .tx: The TRIGger:A:BUS:B<x>:RS232C:TX command tree.

spi property

Return the TRIGger:A:BUS:B<x>:SPI command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .condition: The TRIGger:A:BUS:B<x>:SPI:CONDition command.
  • .data: The TRIGger:A:BUS:B<x>:SPI:DATa command tree.

TriggerABusBItemCan

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN? query and raise an AssertionError if the returned value does not match value.
Properties
  • .condition: The TRIGger:A:BUS:B<x>:CAN:CONDition command.
  • .data: The TRIGger:A:BUS:B<x>:CAN:DATa command tree.
  • .frametype: The TRIGger:A:BUS:B<x>:CAN:FRAMEtype command.
  • .identifier: The TRIGger:A:BUS:B<x>:CAN:IDentifier command tree.
  • .address: The TRIGger:A:BUS:B<x>:CAN:ADDRess command tree.

address property

Return the TRIGger:A:BUS:B<x>:CAN:ADDRess command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:ADDRess? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:ADDRess? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .mode: The TRIGger:A:BUS:B<x>:CAN:ADDRess:MODe command.
  • .value: The TRIGger:A:BUS:B<x>:CAN:ADDRess:VALue command.

condition property

Return the TRIGger:A:BUS:B<x>:CAN:CONDition command.

Description
  • Sets or returns the CAN trigger condition for bus , where x is the bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:CONDition {SOF|FRAMEtype|IDentifier|DATA|IDANDDATA|EOF|ACKMISS}
- TRIGger:A:BUS:B<x>:CAN:CONDition?
Info
  • SOF enables triggering on the start of frame.
  • FRAMEtype enables triggering on the type of frame.
  • IDentifier enables triggering on a matching identifier.
  • DATA enables triggering on matching data.
  • IDANDDATA enables triggering on a matching identifier and matching data.
  • EOF enables triggering on the end of frame.
  • ACKMISS enables triggering on a missing acknowledge.

data property

Return the TRIGger:A:BUS:B<x>:CAN:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .direction: The TRIGger:A:BUS:B<x>:CAN:DATa:DIRection command.
  • .qualifier: The TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier command.
  • .size: The TRIGger:A:BUS:B<x>:CAN:DATa:SIZe command.
  • .value: The TRIGger:A:BUS:B<x>:CAN:DATa:VALue command.

frametype property

Return the TRIGger:A:BUS:B<x>:CAN:FRAMEtype command.

Description
  • This command sets the frame type (data, remote, error or overload) to be used when triggering on a CAN bus signal. The trigger condition must be set to FRAMEtype (using TRIGGER:A:BUS:BX:CAN:CONDITION). B is the bus number (1-2).
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:FRAMEtype? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:FRAMEtype? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:FRAMEtype value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:FRAMEtype {DATA|REMote|ERRor|OVERLoad}
- TRIGger:A:BUS:B<x>:CAN:FRAMEtype?
Info
  • DATA specifies a data frame type.
  • REMote specifies a remote frame type.
  • ERRor specifies an error frame type.
  • OVERLold specifies an overload frame type.

identifier property

Return the TRIGger:A:BUS:B<x>:CAN:IDentifier command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .mode: The TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe command.
  • .value: The TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue command.

TriggerABusBItemCanAddress

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:ADDRess command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:ADDRess? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:ADDRess? query and raise an AssertionError if the returned value does not match value.
Properties
  • .mode: The TRIGger:A:BUS:B<x>:CAN:ADDRess:MODe command.
  • .value: The TRIGger:A:BUS:B<x>:CAN:ADDRess:VALue command.

mode property

Return the TRIGger:A:BUS:B<x>:CAN:ADDRess:MODe command.

Description
  • Sets or returns the CAN addressing mode for bus , where x is the bus number.Use this command to do the following: Trigger on ID Trigger in IDANDDATA
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:ADDRess:MODe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:ADDRess:MODe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:ADDRess:MODe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:ADDRess:MODe {STandard|EXTended}
- TRIGger:A:BUS:B<x>:CAN:ADDRess:MODe?
Info
  • STandard specifies the standard addressing mode.
  • EXTended specifies the extended addressing mode.

value property

Return the TRIGger:A:BUS:B<x>:CAN:ADDRess:VALue command.

Description
  • This command sets the binary address value to be used when triggering on a CAN bus signal. The trigger condition must be set to IDANDDATA OR DATA (using TRIGGER:A:BUS:BX:CAN:CONDITION). B is the bus number (1-2).
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:ADDRess:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:ADDRess:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:ADDRess:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:ADDRess:VALue <QString>
- TRIGger:A:BUS:B<x>:CAN:ADDRess:VALue?
Info
  • <QString> is up to 29 bits specifying the binary identifier value. The only allowed characters in the QString are 0, 1, and X.

TriggerABusBItemCanAddressMode

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:ADDRess:MODe command.

Description
  • Sets or returns the CAN addressing mode for bus , where x is the bus number.Use this command to do the following: Trigger on ID Trigger in IDANDDATA
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:ADDRess:MODe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:ADDRess:MODe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:ADDRess:MODe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:ADDRess:MODe {STandard|EXTended}
- TRIGger:A:BUS:B<x>:CAN:ADDRess:MODe?
Info
  • STandard specifies the standard addressing mode.
  • EXTended specifies the extended addressing mode.

TriggerABusBItemCanAddressValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:ADDRess:VALue command.

Description
  • This command sets the binary address value to be used when triggering on a CAN bus signal. The trigger condition must be set to IDANDDATA OR DATA (using TRIGGER:A:BUS:BX:CAN:CONDITION). B is the bus number (1-2).
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:ADDRess:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:ADDRess:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:ADDRess:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:ADDRess:VALue <QString>
- TRIGger:A:BUS:B<x>:CAN:ADDRess:VALue?
Info
  • <QString> is up to 29 bits specifying the binary identifier value. The only allowed characters in the QString are 0, 1, and X.

TriggerABusBItemCanCondition

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:CONDition command.

Description
  • Sets or returns the CAN trigger condition for bus , where x is the bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:CONDition {SOF|FRAMEtype|IDentifier|DATA|IDANDDATA|EOF|ACKMISS}
- TRIGger:A:BUS:B<x>:CAN:CONDition?
Info
  • SOF enables triggering on the start of frame.
  • FRAMEtype enables triggering on the type of frame.
  • IDentifier enables triggering on a matching identifier.
  • DATA enables triggering on matching data.
  • IDANDDATA enables triggering on a matching identifier and matching data.
  • EOF enables triggering on the end of frame.
  • ACKMISS enables triggering on a missing acknowledge.

TriggerABusBItemCanData

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa? query and raise an AssertionError if the returned value does not match value.
Properties
  • .direction: The TRIGger:A:BUS:B<x>:CAN:DATa:DIRection command.
  • .qualifier: The TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier command.
  • .size: The TRIGger:A:BUS:B<x>:CAN:DATa:SIZe command.
  • .value: The TRIGger:A:BUS:B<x>:CAN:DATa:VALue command.

direction property

Return the TRIGger:A:BUS:B<x>:CAN:DATa:DIRection command.

Description
  • This command sets the data direction (read, write or ‘nocare’) to be used to search on a CAN bus signal. The trigger condition must be set to IDentifier (using TRIGGER:A:BUS:BX:CAN:CONDITION). The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:DATa:DIRection? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:DIRection? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:DIRection value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:DATa:DIRection {READ|WRITE|NOCARE}
- TRIGger:A:BUS:B<x>:CAN:DATa:DIRection?
Info
  • READ sets the CAN data direction to READ.
  • WRITE sets the CAN data direction to WRITE.
  • NOCARE sets the CAN data direction to either.

qualifier property

Return the TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier command.

Description
  • Sets or returns the CAN data qualifier for bus , where x is the bus number. This applies only, if the trigger condition is IDANDDATA or DATA.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier {LESSThan|MOREThan|EQUal|UNEQual|LESSEQual|MOREEQual}
- TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier?
Info
  • LESSThan sets the oscilloscope to trigger when the data is less than the qualifier value.
  • MOREThan sets the oscilloscope to trigger when the data is more than the qualifier value.
  • EQUal sets the oscilloscope to trigger when the data is equal to the qualifier value.
  • UNEQual sets the oscilloscope to trigger when the data is not equal to the qualifier value.
  • LESSEQual sets the oscilloscope to trigger when the data is less than or equal to the qualifier value.
  • MOREEQual sets the oscilloscope to trigger when the data is more than or equal to the qualifier value.

size property

Return the TRIGger:A:BUS:B<x>:CAN:DATa:SIZe command.

Description
  • This command sets the length of the data string, in bytes, to be used when triggering on a CAN bus signal. The trigger condition must be set to IDANDDATA or DATa (using TRIGGER:A:BUS:BX:CAN:CONDITION). The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:CAN:DATa:SIZe?
Info
  • <NR1> is the length of the data string in bytes.

value property

Return the TRIGger:A:BUS:B<x>:CAN:DATa:VALue command.

Description
  • This command sets the binary data value to be used when triggering on a CAN bus signal. The trigger condition must be set to IDANDDATA or DATa (using TRIGGER:A:BUS:BX:CAN:CONDITION). The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:CAN:DATa:VALue?
Info
  • <QString> is the data value in binary format. The only allowed characters in the QString are 0, 1, and X.

TriggerABusBItemCanDataDirection

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:DATa:DIRection command.

Description
  • This command sets the data direction (read, write or ‘nocare’) to be used to search on a CAN bus signal. The trigger condition must be set to IDentifier (using TRIGGER:A:BUS:BX:CAN:CONDITION). The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:DATa:DIRection? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:DIRection? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:DIRection value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:DATa:DIRection {READ|WRITE|NOCARE}
- TRIGger:A:BUS:B<x>:CAN:DATa:DIRection?
Info
  • READ sets the CAN data direction to READ.
  • WRITE sets the CAN data direction to WRITE.
  • NOCARE sets the CAN data direction to either.

TriggerABusBItemCanDataQualifier

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier command.

Description
  • Sets or returns the CAN data qualifier for bus , where x is the bus number. This applies only, if the trigger condition is IDANDDATA or DATA.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier {LESSThan|MOREThan|EQUal|UNEQual|LESSEQual|MOREEQual}
- TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier?
Info
  • LESSThan sets the oscilloscope to trigger when the data is less than the qualifier value.
  • MOREThan sets the oscilloscope to trigger when the data is more than the qualifier value.
  • EQUal sets the oscilloscope to trigger when the data is equal to the qualifier value.
  • UNEQual sets the oscilloscope to trigger when the data is not equal to the qualifier value.
  • LESSEQual sets the oscilloscope to trigger when the data is less than or equal to the qualifier value.
  • MOREEQual sets the oscilloscope to trigger when the data is more than or equal to the qualifier value.

TriggerABusBItemCanDataSize

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:DATa:SIZe command.

Description
  • This command sets the length of the data string, in bytes, to be used when triggering on a CAN bus signal. The trigger condition must be set to IDANDDATA or DATa (using TRIGGER:A:BUS:BX:CAN:CONDITION). The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:CAN:DATa:SIZe?
Info
  • <NR1> is the length of the data string in bytes.

TriggerABusBItemCanDataValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:DATa:VALue command.

Description
  • This command sets the binary data value to be used when triggering on a CAN bus signal. The trigger condition must be set to IDANDDATA or DATa (using TRIGGER:A:BUS:BX:CAN:CONDITION). The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:CAN:DATa:VALue?
Info
  • <QString> is the data value in binary format. The only allowed characters in the QString are 0, 1, and X.

TriggerABusBItemCanFrametype

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:FRAMEtype command.

Description
  • This command sets the frame type (data, remote, error or overload) to be used when triggering on a CAN bus signal. The trigger condition must be set to FRAMEtype (using TRIGGER:A:BUS:BX:CAN:CONDITION). B is the bus number (1-2).
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:FRAMEtype? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:FRAMEtype? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:FRAMEtype value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:FRAMEtype {DATA|REMote|ERRor|OVERLoad}
- TRIGger:A:BUS:B<x>:CAN:FRAMEtype?
Info
  • DATA specifies a data frame type.
  • REMote specifies a remote frame type.
  • ERRor specifies an error frame type.
  • OVERLold specifies an overload frame type.

TriggerABusBItemCanIdentifier

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:IDentifier command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier? query and raise an AssertionError if the returned value does not match value.
Properties
  • .mode: The TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe command.
  • .value: The TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue command.

mode property

Return the TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe command.

Description
  • Sets or returns the CAN addressing mode for bus , where x is the bus number.Use this command to do the following: Trigger on ID Trigger in IDANDDATA
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe {STandard|EXTended}
- TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe?
Info
  • STandard specifies the standard addressing mode.
  • EXTended specifies the extended addressing mode.

value property

Return the TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue command.

Description
  • This command sets the binary address value to be used when triggering on a CAN bus signal. The trigger condition must be set to IDANDDATA OR DATA (using TRIGGER:A:BUS:BX:CAN:CONDITION). B is the bus number (1-2).
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue <QString>
- TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue?
Info
  • <QString> is up to 29 bits specifying the binary identifier value. The only allowed characters in the QString are 0, 1, and X.

TriggerABusBItemCanIdentifierMode

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe command.

Description
  • Sets or returns the CAN addressing mode for bus , where x is the bus number.Use this command to do the following: Trigger on ID Trigger in IDANDDATA
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe {STandard|EXTended}
- TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe?
Info
  • STandard specifies the standard addressing mode.
  • EXTended specifies the extended addressing mode.

TriggerABusBItemCanIdentifierValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue command.

Description
  • This command sets the binary address value to be used when triggering on a CAN bus signal. The trigger condition must be set to IDANDDATA OR DATA (using TRIGGER:A:BUS:BX:CAN:CONDITION). B is the bus number (1-2).
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue <QString>
- TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue?
Info
  • <QString> is up to 29 bits specifying the binary identifier value. The only allowed characters in the QString are 0, 1, and X.

TriggerABusBItemFlexray

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray? query and raise an AssertionError if the returned value does not match value.
Properties
  • .condition: The TRIGger:A:BUS:B<x>:FLEXray:CONDition command.
  • .cyclecount: The TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount command tree.
  • .data: The TRIGger:A:BUS:B<x>:FLEXray:DATa command tree.
  • .eoftype: The TRIGger:A:BUS:B<x>:FLEXray:EOFTYPE command.
  • .errtype: The TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE command.
  • .frameid: The TRIGger:A:BUS:B<x>:FLEXray:FRAMEID command tree.
  • .frametype: The TRIGger:A:BUS:B<x>:FLEXray:FRAMEType command.
  • .header: The TRIGger:A:BUS:B<x>:FLEXray:HEADER command tree.

condition property

Return the TRIGger:A:BUS:B<x>:FLEXray:CONDition command.

Description
  • This command specifies the condition to use when triggering on a FlexRay bus signal (start of frame, frame type, ID, cycle count, header, data, ID and data, EOF, error). B is the bus number B1-B2.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:CONDition {SOF|FRAMEType|IDentifier|CYCLEcount|HEADer|DATA|IDANDDATA|EOF|ERROR}
- TRIGger:A:BUS:B<x>:FLEXray:CONDition?
Info
  • SOF sets the trigger condition to start of frame.
  • FRAMEType sets the trigger condition to frame type.
  • IDentifier sets the trigger condition to identifier.
  • CYCLEcount sets the trigger condition to cycle count.
  • HEADer sets the trigger condition to header.
  • DATA sets the trigger condition to data.
  • IDANDDATA sets the trigger condition to id and data.
  • EOF sets the trigger condition to end of frame.
  • ERROR sets the trigger condition to error.

cyclecount property

Return the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .hivalue: The TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:HIVALue command.
  • .qualifier: The TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:QUALifier command.
  • .value: The TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:VALue command.

data property

Return the TRIGger:A:BUS:B<x>:FLEXray:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .hivalue: The TRIGger:A:BUS:B<x>:FLEXray:DATa:HIVALue command.
  • .offset: The TRIGger:A:BUS:B<x>:FLEXray:DATa:OFFSet command.
  • .qualifier: The TRIGger:A:BUS:B<x>:FLEXray:DATa:QUALifier command.
  • .size: The TRIGger:A:BUS:B<x>:FLEXray:DATa:SIZe command.
  • .value: The TRIGger:A:BUS:B<x>:FLEXray:DATa:VALue command.

eoftype property

Return the TRIGger:A:BUS:B<x>:FLEXray:EOFTYPE command.

Description
  • This command specifies the end of file type (static, dynamic or any) when triggering on the FlexRay bus EOF field. The trigger condition needs to be set to EOF (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:EOFTYPE? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:EOFTYPE? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:EOFTYPE value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:EOFTYPE {STATic|DYNAMic|ANY}
- TRIGger:A:BUS:B<x>:FLEXray:EOFTYPE?
Info
  • STATic specifies triggering on the STATIC end of file type.
  • DYNAMic specifies triggering on the DYNAMIC end of file type.
  • ANY specifies triggering on a STATIC or DYNAMIC end of file type.

errtype property

Return the TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE command.

Description
  • This command specifies the error type when triggering on the FlexRay bus signal. The trigger condition needs to be set to ERROR (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE {CRCHeader|CRCTrailer|SYNCFrame|STARTupnosync|NULLFRStatic|NULLFRDynamic}
- TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE?
Info
  • CRCHeader sets the error type to CRCHeader.
  • CRCTrailer sets the error type to CRCTrailer.
  • SYNCFrame sets the error type to SYNCFrame.
  • STARTupnosync sets the error type to STARTupnosync.
  • NULLFRStatic sets the error type to NULLFRStatic.
  • NULLFRDynamic sets the error type to NULLFRDynamic.

frameid property

Return the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .hivalue: The TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIVALue command.
  • .qualifier: The TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:QUALifier command.
  • .value: The TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VALue command.

frametype property

Return the TRIGger:A:BUS:B<x>:FLEXray:FRAMEType command.

Description
  • This command specifies the frame type (normal, payload, null, sync or startup) when triggering on the FlexRay bus signal. The trigger condition needs to be set to FRAMEType (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEType? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEType? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEType value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEType {NORMal|PAYLoad|NULL|SYNC|STARTup}
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEType?
Info
  • NORMal specifies the normal frame type.
  • PAYLoad specifies the payload frame type.
  • NULL specifies the null frame type.
  • SYNC specifies the sync frame type.
  • STARTup specifies the startup frame type.

header property

Return the TRIGger:A:BUS:B<x>:FLEXray:HEADER command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .crc: The TRIGger:A:BUS:B<x>:FLEXray:HEADER:CRC command.
  • .cyclecount: The TRIGger:A:BUS:B<x>:FLEXray:HEADER:CYCLEcount command.
  • .frameid: The TRIGger:A:BUS:B<x>:FLEXray:HEADER:FRAMEID command.
  • .indbits: The TRIGger:A:BUS:B<x>:FLEXray:HEADER:INDBits command.
  • .paylength: The TRIGger:A:BUS:B<x>:FLEXray:HEADER:PAYLength command.

TriggerABusBItemFlexrayCondition

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:CONDition command.

Description
  • This command specifies the condition to use when triggering on a FlexRay bus signal (start of frame, frame type, ID, cycle count, header, data, ID and data, EOF, error). B is the bus number B1-B2.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:CONDition {SOF|FRAMEType|IDentifier|CYCLEcount|HEADer|DATA|IDANDDATA|EOF|ERROR}
- TRIGger:A:BUS:B<x>:FLEXray:CONDition?
Info
  • SOF sets the trigger condition to start of frame.
  • FRAMEType sets the trigger condition to frame type.
  • IDentifier sets the trigger condition to identifier.
  • CYCLEcount sets the trigger condition to cycle count.
  • HEADer sets the trigger condition to header.
  • DATA sets the trigger condition to data.
  • IDANDDATA sets the trigger condition to id and data.
  • EOF sets the trigger condition to end of frame.
  • ERROR sets the trigger condition to error.

TriggerABusBItemFlexrayCyclecount

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount? query and raise an AssertionError if the returned value does not match value.
Properties
  • .hivalue: The TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:HIVALue command.
  • .qualifier: The TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:QUALifier command.
  • .value: The TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:VALue command.

hivalue property

Return the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:HIVALue command.

Description
  • This command specifies the high value when triggering on a FlexRay bus cycle count field. (Use TRIGGER:A:BUS:BX:FLEXRAY:CYCLECOUNT:VALUE to set the low value.) The trigger condition must be set to CYCLEcount (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:HIVALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:HIVALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:HIVALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:HIVALue <QString>
- TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:HIVALue?
Info
  • <QString> is a quoted string that is the cycle count high value.

qualifier property

Return the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:QUALifier command.

Description
  • Sets or returns the FLEXRAY cycle count qualifier.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:QUALifier {LESSThan|MOREThan|EQUal|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:QUALifier?
Info
  • LESSThan sets the FLEXRAY cycle count qualifier to less than.
  • MOREThan sets the FLEXRAY cycle count qualifier to more than.
  • EQUal sets the FLEXRAY cycle count qualifier to equal.
  • UNEQual sets the FLEXRAY cycle count qualifier to not equal.
  • LESSEQual sets the FLEXRAY cycle count qualifier to less than or equal.
  • MOREEQual sets the FLEXRAY cycle count qualifier to greater than or equal.
  • INrange sets the FLEXRAY cycle count qualifier to in range.
  • OUTrange sets the FLEXRAY cycle count qualifier to out of range.

value property

Return the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:VALue command.

Description
  • This command specifies the low value when triggering on the FlexRay bus cycle count field. (Use TRIGGER:A:BUS:BX:FLEXRAY:CYCLECOUNT:HIVALUE to set the upper value.) The trigger condition must be set to CYCLEcount (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:VALue <QString>
- TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:VALue?
Info
  • <QString> is a quoted binary data string that represents the cycle count low value.

TriggerABusBItemFlexrayCyclecountHivalue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:HIVALue command.

Description
  • This command specifies the high value when triggering on a FlexRay bus cycle count field. (Use TRIGGER:A:BUS:BX:FLEXRAY:CYCLECOUNT:VALUE to set the low value.) The trigger condition must be set to CYCLEcount (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:HIVALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:HIVALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:HIVALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:HIVALue <QString>
- TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:HIVALue?
Info
  • <QString> is a quoted string that is the cycle count high value.

TriggerABusBItemFlexrayCyclecountQualifier

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:QUALifier command.

Description
  • Sets or returns the FLEXRAY cycle count qualifier.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:QUALifier {LESSThan|MOREThan|EQUal|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:QUALifier?
Info
  • LESSThan sets the FLEXRAY cycle count qualifier to less than.
  • MOREThan sets the FLEXRAY cycle count qualifier to more than.
  • EQUal sets the FLEXRAY cycle count qualifier to equal.
  • UNEQual sets the FLEXRAY cycle count qualifier to not equal.
  • LESSEQual sets the FLEXRAY cycle count qualifier to less than or equal.
  • MOREEQual sets the FLEXRAY cycle count qualifier to greater than or equal.
  • INrange sets the FLEXRAY cycle count qualifier to in range.
  • OUTrange sets the FLEXRAY cycle count qualifier to out of range.

TriggerABusBItemFlexrayCyclecountValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:VALue command.

Description
  • This command specifies the low value when triggering on the FlexRay bus cycle count field. (Use TRIGGER:A:BUS:BX:FLEXRAY:CYCLECOUNT:HIVALUE to set the upper value.) The trigger condition must be set to CYCLEcount (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:VALue <QString>
- TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:VALue?
Info
  • <QString> is a quoted binary data string that represents the cycle count low value.

TriggerABusBItemFlexrayData

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa? query and raise an AssertionError if the returned value does not match value.
Properties
  • .hivalue: The TRIGger:A:BUS:B<x>:FLEXray:DATa:HIVALue command.
  • .offset: The TRIGger:A:BUS:B<x>:FLEXray:DATa:OFFSet command.
  • .qualifier: The TRIGger:A:BUS:B<x>:FLEXray:DATa:QUALifier command.
  • .size: The TRIGger:A:BUS:B<x>:FLEXray:DATa:SIZe command.
  • .value: The TRIGger:A:BUS:B<x>:FLEXray:DATa:VALue command.

hivalue property

Return the TRIGger:A:BUS:B<x>:FLEXray:DATa:HIVALue command.

Description
  • This command specifies the high value when triggering on the FlexRay bus data field. (Use TRIGGER:A:BUS:BX:FLEXRAY:DATA:VALUE to set the lower value.) The trigger condition needs to be set to ID or IDANDDATA (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:HIVALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:HIVALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:HIVALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:DATa:HIVALue <QString>
- TRIGger:A:BUS:B<x>:FLEXray:DATa:HIVALue?
Info
  • <QString> is a quoted string that is the binary data high value.

offset property

Return the TRIGger:A:BUS:B<x>:FLEXray:DATa:OFFSet command.

Description
  • This command specifies the offset of the data string, in bytes, when triggering on the FlexRay bus data field. The trigger condition needs to be set to ID or IDANDDATA (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:OFFSet? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:OFFSet? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:OFFSet value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:DATa:OFFSet <NR1>
- TRIGger:A:BUS:B<x>:FLEXray:DATa:OFFSet?
Info
  • <NR1> is the offset of the data string in bytes. A byte offset of -1 signifies ‘don’t care’, and no byte offset is used. The instrument will trigger on or match any byte value that fits.

qualifier property

Return the TRIGger:A:BUS:B<x>:FLEXray:DATa:QUALifier command.

Description
  • Sets or returns the FLEXRAY data qualifier.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:DATa:QUALifier {LESSThan|MOREThan|EQUal|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:FLEXray:DATa:QUALifier?
Info
  • LESSThan sets the FLEXRAY data qualifier to less than.
  • MOREThan sets the FLEXRAY data qualifier to greater than.
  • EQUal sets the FLEXRAY data qualifier to eqaual.
  • UNEQual sets the FLEXRAY data qualifier to not equal.
  • LESSEQual sets the FLEXRAY data qualifier to less than or equal.
  • MOREEQual sets the FLEXRAY data qualifier to greater than or equal.
  • INrange sets the FLEXRAY data qualifier to in range.
  • OUTrange sets the FLEXRAY data qualifier to out of range.

size property

Return the TRIGger:A:BUS:B<x>:FLEXray:DATa:SIZe command.

Description
  • This command specifies the length of the data string, in bytes, when triggering on the FlexRay bus data field. The trigger condition needs to be set to ID or IDANDDATA (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:FLEXray:DATa:SIZe?
Info
  • <NR1> is the FlexRay data string length, in bytes.

value property

Return the TRIGger:A:BUS:B<x>:FLEXray:DATa:VALue command.

Description
  • This command specifies the low value when triggering on the FlexRay bus data field. (Use TRIGGER:A:BUS:BX:FLEXRAY:DATA:HIVALUE to set the upper value.) The trigger condition needs to be set to ID or IDANDDATA (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:FLEXray:DATa:VALue?
Info
  • <QString> is a quoted string.

TriggerABusBItemFlexrayDataHivalue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:DATa:HIVALue command.

Description
  • This command specifies the high value when triggering on the FlexRay bus data field. (Use TRIGGER:A:BUS:BX:FLEXRAY:DATA:VALUE to set the lower value.) The trigger condition needs to be set to ID or IDANDDATA (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:HIVALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:HIVALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:HIVALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:DATa:HIVALue <QString>
- TRIGger:A:BUS:B<x>:FLEXray:DATa:HIVALue?
Info
  • <QString> is a quoted string that is the binary data high value.

TriggerABusBItemFlexrayDataOffset

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:DATa:OFFSet command.

Description
  • This command specifies the offset of the data string, in bytes, when triggering on the FlexRay bus data field. The trigger condition needs to be set to ID or IDANDDATA (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:OFFSet? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:OFFSet? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:OFFSet value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:DATa:OFFSet <NR1>
- TRIGger:A:BUS:B<x>:FLEXray:DATa:OFFSet?
Info
  • <NR1> is the offset of the data string in bytes. A byte offset of -1 signifies ‘don’t care’, and no byte offset is used. The instrument will trigger on or match any byte value that fits.

TriggerABusBItemFlexrayDataQualifier

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:DATa:QUALifier command.

Description
  • Sets or returns the FLEXRAY data qualifier.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:DATa:QUALifier {LESSThan|MOREThan|EQUal|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:FLEXray:DATa:QUALifier?
Info
  • LESSThan sets the FLEXRAY data qualifier to less than.
  • MOREThan sets the FLEXRAY data qualifier to greater than.
  • EQUal sets the FLEXRAY data qualifier to eqaual.
  • UNEQual sets the FLEXRAY data qualifier to not equal.
  • LESSEQual sets the FLEXRAY data qualifier to less than or equal.
  • MOREEQual sets the FLEXRAY data qualifier to greater than or equal.
  • INrange sets the FLEXRAY data qualifier to in range.
  • OUTrange sets the FLEXRAY data qualifier to out of range.

TriggerABusBItemFlexrayDataSize

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:DATa:SIZe command.

Description
  • This command specifies the length of the data string, in bytes, when triggering on the FlexRay bus data field. The trigger condition needs to be set to ID or IDANDDATA (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:FLEXray:DATa:SIZe?
Info
  • <NR1> is the FlexRay data string length, in bytes.

TriggerABusBItemFlexrayDataValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:DATa:VALue command.

Description
  • This command specifies the low value when triggering on the FlexRay bus data field. (Use TRIGGER:A:BUS:BX:FLEXRAY:DATA:HIVALUE to set the upper value.) The trigger condition needs to be set to ID or IDANDDATA (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:DATa:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:FLEXray:DATa:VALue?
Info
  • <QString> is a quoted string.

TriggerABusBItemFlexrayEoftype

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:EOFTYPE command.

Description
  • This command specifies the end of file type (static, dynamic or any) when triggering on the FlexRay bus EOF field. The trigger condition needs to be set to EOF (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:EOFTYPE? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:EOFTYPE? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:EOFTYPE value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:EOFTYPE {STATic|DYNAMic|ANY}
- TRIGger:A:BUS:B<x>:FLEXray:EOFTYPE?
Info
  • STATic specifies triggering on the STATIC end of file type.
  • DYNAMic specifies triggering on the DYNAMIC end of file type.
  • ANY specifies triggering on a STATIC or DYNAMIC end of file type.

TriggerABusBItemFlexrayErrtype

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE command.

Description
  • This command specifies the error type when triggering on the FlexRay bus signal. The trigger condition needs to be set to ERROR (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE {CRCHeader|CRCTrailer|SYNCFrame|STARTupnosync|NULLFRStatic|NULLFRDynamic}
- TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE?
Info
  • CRCHeader sets the error type to CRCHeader.
  • CRCTrailer sets the error type to CRCTrailer.
  • SYNCFrame sets the error type to SYNCFrame.
  • STARTupnosync sets the error type to STARTupnosync.
  • NULLFRStatic sets the error type to NULLFRStatic.
  • NULLFRDynamic sets the error type to NULLFRDynamic.

TriggerABusBItemFlexrayFrameid

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:FRAMEID command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID? query and raise an AssertionError if the returned value does not match value.
Properties
  • .hivalue: The TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIVALue command.
  • .qualifier: The TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:QUALifier command.
  • .value: The TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VALue command.

hivalue property

Return the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIVALue command.

Description
  • This command specifies the high value when triggering on the FlexRay bus frame ID field. (Use TRIGGER:A:BUS:BX:FLEXRAY:FRAMEID:VALUE to set the low value.) The trigger condition needs to be set to IDentifier (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIVALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIVALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIVALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIVALue <QString>
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIVALue?
Info
  • <QString> is a quoted string that is the binary frame ID high value.

qualifier property

Return the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:QUALifier command.

Description
  • Sets or returns the FLEXRAY frame ID qualifier.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:QUALifier {LESSThan|MOREThan|EQUal|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:QUALifier?
Info
  • LESSThan sets the frame id qualifier to less than.
  • MOREThan sets the frame id qualifier to greater than.
  • EQUal sets the frame id qualifier to equal.
  • UNEQual sets the frame id qualifier to not equal.
  • LESSEQual sets the frame id qualifier to less than or equal.
  • MOREEQual sets the frame id qualifier to greater than or equal.
  • INrange sets the frame id qualifier to in range.
  • OUTrange sets the frame id qualifier to out of range.

value property

Return the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VALue command.

Description
  • This command specifies the low value when triggering on the FlexRay bus frame ID field. (Use TRIGGER:A:BUS:BX:FLEXRAY:FRAMEID:HIVALUE to set the high value.) The trigger condition needs to be set to IDentifier (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VALue <QString>
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VALue?
Info
  • <QString> is a quoted string that is the FlexRay frame ID low value.

TriggerABusBItemFlexrayFrameidHivalue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIVALue command.

Description
  • This command specifies the high value when triggering on the FlexRay bus frame ID field. (Use TRIGGER:A:BUS:BX:FLEXRAY:FRAMEID:VALUE to set the low value.) The trigger condition needs to be set to IDentifier (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIVALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIVALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIVALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIVALue <QString>
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIVALue?
Info
  • <QString> is a quoted string that is the binary frame ID high value.

TriggerABusBItemFlexrayFrameidQualifier

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:QUALifier command.

Description
  • Sets or returns the FLEXRAY frame ID qualifier.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:QUALifier {LESSThan|MOREThan|EQUal|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:QUALifier?
Info
  • LESSThan sets the frame id qualifier to less than.
  • MOREThan sets the frame id qualifier to greater than.
  • EQUal sets the frame id qualifier to equal.
  • UNEQual sets the frame id qualifier to not equal.
  • LESSEQual sets the frame id qualifier to less than or equal.
  • MOREEQual sets the frame id qualifier to greater than or equal.
  • INrange sets the frame id qualifier to in range.
  • OUTrange sets the frame id qualifier to out of range.

TriggerABusBItemFlexrayFrameidValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VALue command.

Description
  • This command specifies the low value when triggering on the FlexRay bus frame ID field. (Use TRIGGER:A:BUS:BX:FLEXRAY:FRAMEID:HIVALUE to set the high value.) The trigger condition needs to be set to IDentifier (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VALue <QString>
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VALue?
Info
  • <QString> is a quoted string that is the FlexRay frame ID low value.

TriggerABusBItemFlexrayFrametype

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:FRAMEType command.

Description
  • This command specifies the frame type (normal, payload, null, sync or startup) when triggering on the FlexRay bus signal. The trigger condition needs to be set to FRAMEType (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEType? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEType? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:FRAMEType value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEType {NORMal|PAYLoad|NULL|SYNC|STARTup}
- TRIGger:A:BUS:B<x>:FLEXray:FRAMEType?
Info
  • NORMal specifies the normal frame type.
  • PAYLoad specifies the payload frame type.
  • NULL specifies the null frame type.
  • SYNC specifies the sync frame type.
  • STARTup specifies the startup frame type.

TriggerABusBItemFlexrayHeader

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:HEADER command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER? query and raise an AssertionError if the returned value does not match value.
Properties
  • .crc: The TRIGger:A:BUS:B<x>:FLEXray:HEADER:CRC command.
  • .cyclecount: The TRIGger:A:BUS:B<x>:FLEXray:HEADER:CYCLEcount command.
  • .frameid: The TRIGger:A:BUS:B<x>:FLEXray:HEADER:FRAMEID command.
  • .indbits: The TRIGger:A:BUS:B<x>:FLEXray:HEADER:INDBits command.
  • .paylength: The TRIGger:A:BUS:B<x>:FLEXray:HEADER:PAYLength command.

crc property

Return the TRIGger:A:BUS:B<x>:FLEXray:HEADER:CRC command.

Description
  • This command specifies the CRC portion of the binary header string when triggering on the FlexRay bus signal. The trigger condition needs to be set to HEADer (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:CRC? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:CRC? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:CRC value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:CRC <QString>
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:CRC?
Info
  • <QString> is a quoted string that is the CRC portion of the binary header string.

cyclecount property

Return the TRIGger:A:BUS:B<x>:FLEXray:HEADER:CYCLEcount command.

Description
  • This command specifies the cycle count portion of the binary header string when triggering on the FlexRay bus header. The trigger condition needs to be set to HEADer (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:CYCLEcount? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:CYCLEcount? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:CYCLEcount value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:CYCLEcount <QString>
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:CYCLEcount?
Info
  • <QString> is a quoted string that is the cycle count portion of the binary header string.

frameid property

Return the TRIGger:A:BUS:B<x>:FLEXray:HEADER:FRAMEID command.

Description
  • This command specifies the frame ID portion of the binary header string when triggering on the FlexRay bus header. The trigger condition needs to be set to HEADer (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:FRAMEID? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:FRAMEID? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:FRAMEID value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:FRAMEID <QString>
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:FRAMEID?
Info
  • <QString> is a quoted string that represents the frame ID portion of the binary header string.

indbits property

Return the TRIGger:A:BUS:B<x>:FLEXray:HEADER:INDBits command.

Description
  • This command specifies the indicator bits portion of the binary header string when triggering on the FlexRay bus header. The trigger condition needs to be set to HEADer (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:INDBits? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:INDBits? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:INDBits value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:INDBits <QString>
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:INDBits?
Info
  • <QString> is a quoted string that is the indicator bits portion of the binary header string.

paylength property

Return the TRIGger:A:BUS:B<x>:FLEXray:HEADER:PAYLength command.

Description
  • This command specifies the payload length portion of the binary header string when triggering on the FlexRay bus header. The trigger condition needs to be set to HEADer (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:PAYLength? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:PAYLength? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:PAYLength value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:PAYLength <QString>
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:PAYLength?
Info
  • <QString> is the length of the payload portion of the Binary header string.

TriggerABusBItemFlexrayHeaderCrc

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:HEADER:CRC command.

Description
  • This command specifies the CRC portion of the binary header string when triggering on the FlexRay bus signal. The trigger condition needs to be set to HEADer (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:CRC? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:CRC? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:CRC value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:CRC <QString>
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:CRC?
Info
  • <QString> is a quoted string that is the CRC portion of the binary header string.

TriggerABusBItemFlexrayHeaderCyclecount

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:HEADER:CYCLEcount command.

Description
  • This command specifies the cycle count portion of the binary header string when triggering on the FlexRay bus header. The trigger condition needs to be set to HEADer (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:CYCLEcount? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:CYCLEcount? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:CYCLEcount value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:CYCLEcount <QString>
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:CYCLEcount?
Info
  • <QString> is a quoted string that is the cycle count portion of the binary header string.

TriggerABusBItemFlexrayHeaderFrameid

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:HEADER:FRAMEID command.

Description
  • This command specifies the frame ID portion of the binary header string when triggering on the FlexRay bus header. The trigger condition needs to be set to HEADer (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:FRAMEID? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:FRAMEID? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:FRAMEID value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:FRAMEID <QString>
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:FRAMEID?
Info
  • <QString> is a quoted string that represents the frame ID portion of the binary header string.

TriggerABusBItemFlexrayHeaderIndbits

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:HEADER:INDBits command.

Description
  • This command specifies the indicator bits portion of the binary header string when triggering on the FlexRay bus header. The trigger condition needs to be set to HEADer (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:INDBits? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:INDBits? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:INDBits value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:INDBits <QString>
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:INDBits?
Info
  • <QString> is a quoted string that is the indicator bits portion of the binary header string.

TriggerABusBItemFlexrayHeaderPaylength

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:FLEXray:HEADER:PAYLength command.

Description
  • This command specifies the payload length portion of the binary header string when triggering on the FlexRay bus header. The trigger condition needs to be set to HEADer (using TRIGGER:A:BUS:BX:FLEXRAY:CONDITION). B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:PAYLength? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:PAYLength? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:FLEXray:HEADER:PAYLength value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:PAYLength <QString>
- TRIGger:A:BUS:B<x>:FLEXray:HEADER:PAYLength?
Info
  • <QString> is the length of the payload portion of the Binary header string.

TriggerABusBItemI2c

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:I2C command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C? query and raise an AssertionError if the returned value does not match value.
Properties
  • .address: The TRIGger:A:BUS:B<x>:I2C:ADDRess command tree.
  • .condition: The TRIGger:A:BUS:B<x>:I2C:CONDition command.
  • .data: The TRIGger:A:BUS:B<x>:I2C:DATa command tree.

address property

Return the TRIGger:A:BUS:B<x>:I2C:ADDRess command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .mode: The TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe command.
  • .type: The TRIGger:A:BUS:B<x>:I2C:ADDRess:TYPe command.
  • .value: The TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue command.

condition property

Return the TRIGger:A:BUS:B<x>:I2C:CONDition command.

Description
  • This command specifies the trigger condition for an I 2 C trigger. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:CONDition {STARt|STOP|REPEATstart|ACKMISS|ADDRess|DATA|ADDRANDDATA}
- TRIGger:A:BUS:B<x>:I2C:CONDition?
Info
  • STARt specifies a search based on start condition.
  • STOP specifies a search based on stop condition.
  • REPEATstart specifies a search based on repeat of start condition.
  • ACKMISS specifies a search based on missing acknowledgement condition.
  • ADDRess specifies a search based on address.
  • DATA specifies a search based on data.
  • ADDRANDDATA specifies a search based on address and data.

data property

Return the TRIGger:A:BUS:B<x>:I2C:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .direction: The TRIGger:A:BUS:B<x>:I2C:DATa:DIRection command.
  • .size: The TRIGger:A:BUS:B<x>:I2C:DATa:SIZe command.
  • .value: The TRIGger:A:BUS:B<x>:I2C:DATa:VALue command.

TriggerABusBItemI2cAddress

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:I2C:ADDRess command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess? query and raise an AssertionError if the returned value does not match value.
Properties
  • .mode: The TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe command.
  • .type: The TRIGger:A:BUS:B<x>:I2C:ADDRess:TYPe command.
  • .value: The TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue command.

mode property

Return the TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe command.

Description
  • This command specifies the I 2 C address mode to 7 or 10-bit. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe {ADDR7|ADDR10}
- TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe?
Info
  • ADDR7 specifies the 7-bit I2C address mode.
  • ADDR10 specifies the 10-bit I2C address mode.

type property

Return the TRIGger:A:BUS:B<x>:I2C:ADDRess:TYPe command.

Description
  • This command specifies the I 2 C address type. The only supported address type is USER. Applies to bus , where x
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:TYPe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:TYPe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:TYPe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:ADDRess:TYPe {GENeralcall|STARtbyte|HSmode|EEPROM|USER}
- TRIGger:A:BUS:B<x>:I2C:ADDRess:TYPe?
Info
  • GENeralcall specifies a general call address.
  • STARtbyte specifies a start byte address.
  • HSmode specifies a high-speed mode address.
  • EEPROM specifies an EEPROM address.
  • USER specifies a user address.

value property

Return the TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue command.

Description
  • This command specifies the binary address string used for the I 2 C trigger if the trigger condition is ADDRESS or ADDRANDDATA. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue <QString>
- TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue?
Info
  • <QString> is up to 7 or 10-bits depending on the address mode that specifies the address. The only allowed characters in the QString are 0, 1, and X.

TriggerABusBItemI2cAddressMode

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe command.

Description
  • This command specifies the I 2 C address mode to 7 or 10-bit. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe {ADDR7|ADDR10}
- TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe?
Info
  • ADDR7 specifies the 7-bit I2C address mode.
  • ADDR10 specifies the 10-bit I2C address mode.

TriggerABusBItemI2cAddressType

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:I2C:ADDRess:TYPe command.

Description
  • This command specifies the I 2 C address type. The only supported address type is USER. Applies to bus , where x
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:TYPe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:TYPe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:TYPe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:ADDRess:TYPe {GENeralcall|STARtbyte|HSmode|EEPROM|USER}
- TRIGger:A:BUS:B<x>:I2C:ADDRess:TYPe?
Info
  • GENeralcall specifies a general call address.
  • STARtbyte specifies a start byte address.
  • HSmode specifies a high-speed mode address.
  • EEPROM specifies an EEPROM address.
  • USER specifies a user address.

TriggerABusBItemI2cAddressValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue command.

Description
  • This command specifies the binary address string used for the I 2 C trigger if the trigger condition is ADDRESS or ADDRANDDATA. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue <QString>
- TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue?
Info
  • <QString> is up to 7 or 10-bits depending on the address mode that specifies the address. The only allowed characters in the QString are 0, 1, and X.

TriggerABusBItemI2cCondition

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:I2C:CONDition command.

Description
  • This command specifies the trigger condition for an I 2 C trigger. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:CONDition {STARt|STOP|REPEATstart|ACKMISS|ADDRess|DATA|ADDRANDDATA}
- TRIGger:A:BUS:B<x>:I2C:CONDition?
Info
  • STARt specifies a search based on start condition.
  • STOP specifies a search based on stop condition.
  • REPEATstart specifies a search based on repeat of start condition.
  • ACKMISS specifies a search based on missing acknowledgement condition.
  • ADDRess specifies a search based on address.
  • DATA specifies a search based on data.
  • ADDRANDDATA specifies a search based on address and data.

TriggerABusBItemI2cData

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:I2C:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa? query and raise an AssertionError if the returned value does not match value.
Properties
  • .direction: The TRIGger:A:BUS:B<x>:I2C:DATa:DIRection command.
  • .size: The TRIGger:A:BUS:B<x>:I2C:DATa:SIZe command.
  • .value: The TRIGger:A:BUS:B<x>:I2C:DATa:VALue command.

direction property

Return the TRIGger:A:BUS:B<x>:I2C:DATa:DIRection command.

Description
  • This command specifies the I 2 C trigger type to be valid on a Read, Write, or Either condition. Read or write is indicated by the R/W bit in the I 2 C protocol. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:DATa:DIRection? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa:DIRection? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa:DIRection value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:DATa:DIRection {READ|WRITE|NOCARE}
- TRIGger:A:BUS:B<x>:I2C:DATa:DIRection?
Info
  • READ specifies read as the data direction.
  • WRITE specifies write as the data direction.
  • NOCARE specifies either as the data direction.

size property

Return the TRIGger:A:BUS:B<x>:I2C:DATa:SIZe command.

Description
  • This command specifies the length of the data string in bytes to be used for an I2C trigger if the trigger condition is DATA or ADDRANDDATA. Applies to bus , where the bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:I2C:DATa:SIZe?
Info
  • <NR1> is the length of the data string in bytes.

value property

Return the TRIGger:A:BUS:B<x>:I2C:DATa:VALue command.

Description
  • This command specifies the binary data string used for I2C triggering if the trigger condition is DATA or ADDRANDDATA. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:I2C:DATa:VALue?
Info
  • <QString> is the binary data string, where the number of bits is 8 times the number of bytes specified. The only allowed characters in the string are 0, 1, and X.

TriggerABusBItemI2cDataDirection

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:I2C:DATa:DIRection command.

Description
  • This command specifies the I 2 C trigger type to be valid on a Read, Write, or Either condition. Read or write is indicated by the R/W bit in the I 2 C protocol. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:DATa:DIRection? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa:DIRection? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa:DIRection value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:DATa:DIRection {READ|WRITE|NOCARE}
- TRIGger:A:BUS:B<x>:I2C:DATa:DIRection?
Info
  • READ specifies read as the data direction.
  • WRITE specifies write as the data direction.
  • NOCARE specifies either as the data direction.

TriggerABusBItemI2cDataSize

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:I2C:DATa:SIZe command.

Description
  • This command specifies the length of the data string in bytes to be used for an I2C trigger if the trigger condition is DATA or ADDRANDDATA. Applies to bus , where the bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:I2C:DATa:SIZe?
Info
  • <NR1> is the length of the data string in bytes.

TriggerABusBItemI2cDataValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:I2C:DATa:VALue command.

Description
  • This command specifies the binary data string used for I2C triggering if the trigger condition is DATA or ADDRANDDATA. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:I2C:DATa:VALue?
Info
  • <QString> is the binary data string, where the number of bits is 8 times the number of bytes specified. The only allowed characters in the string are 0, 1, and X.

TriggerABusBItemLin

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:LIN command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN? query and raise an AssertionError if the returned value does not match value.
Properties
  • .condition: The TRIGger:A:BUS:B<x>:LIN:CONDition command.
  • .data: The TRIGger:A:BUS:B<x>:LIN:DATa command tree.
  • .errtype: The TRIGger:A:BUS:B<x>:LIN:ERRTYPE command.
  • .identifier: The TRIGger:A:BUS:B<x>:LIN:IDentifier command tree.

condition property

Return the TRIGger:A:BUS:B<x>:LIN:CONDition command.

Description
  • This command specifies the trigger condition for LIN. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:CONDition {SYNCField|IDentifier|DATA|IDANDDATA|WAKEup|SLEEP|ERROR}
- TRIGger:A:BUS:B<x>:LIN:CONDition?
Info
  • SYNCField sets the LIN trigger condition to sync field.
  • IDentifier sets the LIN trigger condition to identifier.
  • DATA sets the LIN trigger condition to data.
  • IDANDDATA sets the LIN trigger condition to id and data.
  • WAKEup sets the LIN trigger condition to wake up.
  • SLEEP sets the LIN trigger condition to sleep.
  • ERROR sets the LIN trigger condition to error.

data property

Return the TRIGger:A:BUS:B<x>:LIN:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .hivalue: The TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue command.
  • .qualifier: The TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier command.
  • .size: The TRIGger:A:BUS:B<x>:LIN:DATa:SIZe command.
  • .value: The TRIGger:A:BUS:B<x>:LIN:DATa:VALue command.

errtype property

Return the TRIGger:A:BUS:B<x>:LIN:ERRTYPE command.

Description
  • This command specifies the error type be used for LIN trigger. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:ERRTYPE? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:ERRTYPE? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:ERRTYPE value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:ERRTYPE {SYNC|PARity|CHecksum}
- TRIGger:A:BUS:B<x>:LIN:ERRTYPE?
Info
  • SYNC sets the LIN error type to SYNC.
  • PARity sets the LIN error type to parity.
  • CHecksum sets the LIN error type to checksum.

identifier property

Return the TRIGger:A:BUS:B<x>:LIN:IDentifier command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:IDentifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:IDentifier? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .value: The TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue command.

TriggerABusBItemLinCondition

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:LIN:CONDition command.

Description
  • This command specifies the trigger condition for LIN. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:CONDition {SYNCField|IDentifier|DATA|IDANDDATA|WAKEup|SLEEP|ERROR}
- TRIGger:A:BUS:B<x>:LIN:CONDition?
Info
  • SYNCField sets the LIN trigger condition to sync field.
  • IDentifier sets the LIN trigger condition to identifier.
  • DATA sets the LIN trigger condition to data.
  • IDANDDATA sets the LIN trigger condition to id and data.
  • WAKEup sets the LIN trigger condition to wake up.
  • SLEEP sets the LIN trigger condition to sleep.
  • ERROR sets the LIN trigger condition to error.

TriggerABusBItemLinData

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:LIN:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa? query and raise an AssertionError if the returned value does not match value.
Properties
  • .hivalue: The TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue command.
  • .qualifier: The TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier command.
  • .size: The TRIGger:A:BUS:B<x>:LIN:DATa:SIZe command.
  • .value: The TRIGger:A:BUS:B<x>:LIN:DATa:VALue command.

hivalue property

Return the TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue command.

Description
  • This command specifies the high data value string used for a LIN bus trigger when the trigger condition is DATA or IDANDDATA and the data qualifier is INRANGE or OUTRANGE. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue <QString>
- TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue?
Info
  • <QString> is a quoted string that is the binary data string used for LIN trigger if the trigger condition is ID or IDANDDATA.

qualifier property

Return the TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier command.

Description
  • Sets or returns the LIN data qualifier. This only applies if the trigger condition is IDANDDATA or DATA.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier {LESSThan|MOREThan|EQUal|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier?
Info
  • LESSThan sets the LIN data qualifier to less than.
  • MOREThan sets the LIN data qualifier to greater than.
  • EQUal sets the LIN data qualifier to equal.
  • UNEQual sets the LIN data qualifier to not equal.
  • LESSEQual sets the LIN data qualifier to less than or equal.
  • MOREEQual sets the LIN data qualifier to greater than or equal.
  • INrange sets the LIN data qualifier to in range.
  • OUTrange sets the LIN data qualifier to out of range.

size property

Return the TRIGger:A:BUS:B<x>:LIN:DATa:SIZe command.

Description
  • This command specifies the length of the data string in bytes to be used for LIN trigger. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:LIN:DATa:SIZe?
Info
  • <NR1> is the size of the data string in bytes.

value property

Return the TRIGger:A:BUS:B<x>:LIN:DATa:VALue command.

Description
  • This command specifies the binary data string to be used for LIN trigger condition if trigger condition is ID or IDANDDATA. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:LIN:DATa:VALue?
Info
  • <QString> is a quoted string that is the LIN trigger data value.

TriggerABusBItemLinDataHivalue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue command.

Description
  • This command specifies the high data value string used for a LIN bus trigger when the trigger condition is DATA or IDANDDATA and the data qualifier is INRANGE or OUTRANGE. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue <QString>
- TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue?
Info
  • <QString> is a quoted string that is the binary data string used for LIN trigger if the trigger condition is ID or IDANDDATA.

TriggerABusBItemLinDataQualifier

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier command.

Description
  • Sets or returns the LIN data qualifier. This only applies if the trigger condition is IDANDDATA or DATA.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier {LESSThan|MOREThan|EQUal|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier?
Info
  • LESSThan sets the LIN data qualifier to less than.
  • MOREThan sets the LIN data qualifier to greater than.
  • EQUal sets the LIN data qualifier to equal.
  • UNEQual sets the LIN data qualifier to not equal.
  • LESSEQual sets the LIN data qualifier to less than or equal.
  • MOREEQual sets the LIN data qualifier to greater than or equal.
  • INrange sets the LIN data qualifier to in range.
  • OUTrange sets the LIN data qualifier to out of range.

TriggerABusBItemLinDataSize

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:LIN:DATa:SIZe command.

Description
  • This command specifies the length of the data string in bytes to be used for LIN trigger. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:LIN:DATa:SIZe?
Info
  • <NR1> is the size of the data string in bytes.

TriggerABusBItemLinDataValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:LIN:DATa:VALue command.

Description
  • This command specifies the binary data string to be used for LIN trigger condition if trigger condition is ID or IDANDDATA. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:LIN:DATa:VALue?
Info
  • <QString> is a quoted string that is the LIN trigger data value.

TriggerABusBItemLinErrtype

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:LIN:ERRTYPE command.

Description
  • This command specifies the error type be used for LIN trigger. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:ERRTYPE? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:ERRTYPE? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:ERRTYPE value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:ERRTYPE {SYNC|PARity|CHecksum}
- TRIGger:A:BUS:B<x>:LIN:ERRTYPE?
Info
  • SYNC sets the LIN error type to SYNC.
  • PARity sets the LIN error type to parity.
  • CHecksum sets the LIN error type to checksum.

TriggerABusBItemLinIdentifier

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:LIN:IDentifier command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:IDentifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:IDentifier? query and raise an AssertionError if the returned value does not match value.
Properties
  • .value: The TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue command.

value property

Return the TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue command.

Description
  • This command specifies the binary address string used for LIN bus trigger if the trigger condition is ID or IDANDDATA. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue <QString>
- TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue?
Info
  • <QString> is the binary address string used for LIN trigger if the trigger condition is ID or IDANDDATA.

TriggerABusBItemLinIdentifierValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue command.

Description
  • This command specifies the binary address string used for LIN bus trigger if the trigger condition is ID or IDANDDATA. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue <QString>
- TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue?
Info
  • <QString> is the binary address string used for LIN trigger if the trigger condition is ID or IDANDDATA.

TriggerABusBItemParallel

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:PARallel command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:PARallel? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:PARallel? query and raise an AssertionError if the returned value does not match value.
Properties
  • .value: The TRIGger:A:BUS:B<x>:PARallel:VALue command.

value property

Return the TRIGger:A:BUS:B<x>:PARallel:VALue command.

Description
  • This command specifies the binary data string to be used for a Parallel trigger. Applies to bus , where x
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:PARallel:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:PARallel:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:PARallel:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:PARallel:VALue <QString>
- TRIGger:A:BUS:B<x>:PARallel:VALue?
Info
  • <QString> is the binary data string.

TriggerABusBItemParallelValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:PARallel:VALue command.

Description
  • This command specifies the binary data string to be used for a Parallel trigger. Applies to bus , where x
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:PARallel:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:PARallel:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:PARallel:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:PARallel:VALue <QString>
- TRIGger:A:BUS:B<x>:PARallel:VALue?
Info
  • <QString> is the binary data string.

TriggerABusBItemRs232c

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:RS232C command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C? query and raise an AssertionError if the returned value does not match value.
Properties
  • .condition: The TRIGger:A:BUS:B<x>:RS232C:CONDition command.
  • .rx: The TRIGger:A:BUS:B<x>:RS232C:RX command tree.
  • .tx: The TRIGger:A:BUS:B<x>:RS232C:TX command tree.

condition property

Return the TRIGger:A:BUS:B<x>:RS232C:CONDition command.

Description
  • Sets or returns the condition for a RS232C trigger, where x is the bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:RS232C:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:RS232C:CONDition {RXSTArt|RXDATA|RXENDPacket|RXPARity|TXSTArt|TXDATA|TXENDPacket|TXPARity|}
- TRIGger:A:BUS:B<x>:RS232C:CONDition?
Info
  • RXSTArt specifies a search based on the RX Start Bit.
  • RXDATA specifies a search based on RX Data.
  • RXENDPacket specifies a search based on the RX End of Packet condition.
  • RXPARity specifies a search based on the RX parity.
  • TXSTArt specifies a search base on the TX Start Bit.
  • TXDATA specifies a search based on TX Data.
  • TXENDPacket specifies a search based on the TX End of Packet condition.
  • TXPARity specifies a search based on the TX parity.

rx property

Return the TRIGger:A:BUS:B<x>:RS232C:RX command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:RX? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:RX? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .data: The TRIGger:A:BUS:B<x>:RS232C:RX:DATa command tree.

tx property

Return the TRIGger:A:BUS:B<x>:RS232C:TX command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:TX? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:TX? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .data: The TRIGger:A:BUS:B<x>:RS232C:TX:DATa command tree.

TriggerABusBItemRs232cCondition

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:RS232C:CONDition command.

Description
  • Sets or returns the condition for a RS232C trigger, where x is the bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:RS232C:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:RS232C:CONDition {RXSTArt|RXDATA|RXENDPacket|RXPARity|TXSTArt|TXDATA|TXENDPacket|TXPARity|}
- TRIGger:A:BUS:B<x>:RS232C:CONDition?
Info
  • RXSTArt specifies a search based on the RX Start Bit.
  • RXDATA specifies a search based on RX Data.
  • RXENDPacket specifies a search based on the RX End of Packet condition.
  • RXPARity specifies a search based on the RX parity.
  • TXSTArt specifies a search base on the TX Start Bit.
  • TXDATA specifies a search based on TX Data.
  • TXENDPacket specifies a search based on the TX End of Packet condition.
  • TXPARity specifies a search based on the TX parity.

TriggerABusBItemRs232cRx

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:RS232C:RX command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:RX? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:RX? query and raise an AssertionError if the returned value does not match value.
Properties
  • .data: The TRIGger:A:BUS:B<x>:RS232C:RX:DATa command tree.

data property

Return the TRIGger:A:BUS:B<x>:RS232C:RX:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:RX:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:RX:DATa? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .size: The TRIGger:A:BUS:B<x>:RS232C:RX:DATa:SIZe command.
  • .value: The TRIGger:A:BUS:B<x>:RS232C:RX:DATa:VALue command.

TriggerABusBItemRs232cRxData

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:RS232C:RX:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:RX:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:RX:DATa? query and raise an AssertionError if the returned value does not match value.
Properties
  • .size: The TRIGger:A:BUS:B<x>:RS232C:RX:DATa:SIZe command.
  • .value: The TRIGger:A:BUS:B<x>:RS232C:RX:DATa:VALue command.

size property

Return the TRIGger:A:BUS:B<x>:RS232C:RX:DATa:SIZe command.

Description
  • This command specifies the length of the data string in Bytes for an RS-232 Trigger if the trigger condition is RXDATA. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:RX:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:RX:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:RS232C:RX:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:RS232C:RX:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:RS232C:RX:DATa:SIZe?
Info
  • <NR1> is the length of the data string in bytes.

value property

Return the TRIGger:A:BUS:B<x>:RS232C:RX:DATa:VALue command.

Description
  • This command specifies the binary data string for an RS-232 trigger if the trigger condition involves RX. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:RX:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:RX:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write() method will send the TRIGger:A:BUS:B<x>:RS232C:RX:DATa:VALue command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:RS232C:RX:DATa:VALue
- TRIGger:A:BUS:B<x>:RS232C:RX:DATa:VALue?
Info
  • <Qstring> is the binary data string to be used for the trigger.

TriggerABusBItemRs232cRxDataSize

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:RS232C:RX:DATa:SIZe command.

Description
  • This command specifies the length of the data string in Bytes for an RS-232 Trigger if the trigger condition is RXDATA. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:RX:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:RX:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:RS232C:RX:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:RS232C:RX:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:RS232C:RX:DATa:SIZe?
Info
  • <NR1> is the length of the data string in bytes.

TriggerABusBItemRs232cRxDataValue

Bases: SCPICmdWriteNoArguments, SCPICmdRead

The TRIGger:A:BUS:B<x>:RS232C:RX:DATa:VALue command.

Description
  • This command specifies the binary data string for an RS-232 trigger if the trigger condition involves RX. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:RX:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:RX:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write() method will send the TRIGger:A:BUS:B<x>:RS232C:RX:DATa:VALue command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:RS232C:RX:DATa:VALue
- TRIGger:A:BUS:B<x>:RS232C:RX:DATa:VALue?
Info
  • <Qstring> is the binary data string to be used for the trigger.

TriggerABusBItemRs232cTx

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:RS232C:TX command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:TX? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:TX? query and raise an AssertionError if the returned value does not match value.
Properties
  • .data: The TRIGger:A:BUS:B<x>:RS232C:TX:DATa command tree.

data property

Return the TRIGger:A:BUS:B<x>:RS232C:TX:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:TX:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:TX:DATa? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .size: The TRIGger:A:BUS:B<x>:RS232C:TX:DATa:SIZe command.
  • .value: The TRIGger:A:BUS:B<x>:RS232C:TX:DATa:VALue command.

TriggerABusBItemRs232cTxData

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:RS232C:TX:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:TX:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:TX:DATa? query and raise an AssertionError if the returned value does not match value.
Properties
  • .size: The TRIGger:A:BUS:B<x>:RS232C:TX:DATa:SIZe command.
  • .value: The TRIGger:A:BUS:B<x>:RS232C:TX:DATa:VALue command.

size property

Return the TRIGger:A:BUS:B<x>:RS232C:TX:DATa:SIZe command.

Description
  • This command specifies the length of the data string for an RS-232 trigger if the trigger condition is TXDATA. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:TX:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:TX:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:RS232C:TX:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:RS232C:TX:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:RS232C:TX:DATa:SIZe?
Info
  • <NR1> is the length of the data string in Bytes.

value property

Return the TRIGger:A:BUS:B<x>:RS232C:TX:DATa:VALue command.

Description
  • This command specifies the binary data string for an RS-232 trigger if the condition involves TX. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:TX:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:TX:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write() method will send the TRIGger:A:BUS:B<x>:RS232C:TX:DATa:VALue command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:RS232C:TX:DATa:VALue
- TRIGger:A:BUS:B<x>:RS232C:TX:DATa:VALue?
Info
  • <Qstring> is the binary data string to be used for the trigger.

TriggerABusBItemRs232cTxDataSize

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:RS232C:TX:DATa:SIZe command.

Description
  • This command specifies the length of the data string for an RS-232 trigger if the trigger condition is TXDATA. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:TX:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:TX:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:RS232C:TX:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:RS232C:TX:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:RS232C:TX:DATa:SIZe?
Info
  • <NR1> is the length of the data string in Bytes.

TriggerABusBItemRs232cTxDataValue

Bases: SCPICmdWriteNoArguments, SCPICmdRead

The TRIGger:A:BUS:B<x>:RS232C:TX:DATa:VALue command.

Description
  • This command specifies the binary data string for an RS-232 trigger if the condition involves TX. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:TX:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:TX:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write() method will send the TRIGger:A:BUS:B<x>:RS232C:TX:DATa:VALue command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:RS232C:TX:DATa:VALue
- TRIGger:A:BUS:B<x>:RS232C:TX:DATa:VALue?
Info
  • <Qstring> is the binary data string to be used for the trigger.

TriggerABusBItemSpi

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:SPI command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI? query and raise an AssertionError if the returned value does not match value.
Properties
  • .condition: The TRIGger:A:BUS:B<x>:SPI:CONDition command.
  • .data: The TRIGger:A:BUS:B<x>:SPI:DATa command tree.

condition property

Return the TRIGger:A:BUS:B<x>:SPI:CONDition command.

Description
  • This command specifies the trigger condition for a SPI trigger. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SPI:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SPI:CONDition {SS|STARTofframe|MISO|MOSI|MISOMOSI}
- TRIGger:A:BUS:B<x>:SPI:CONDition?
Info
  • SS specifies the Slave Selection condition.
  • STARTofframe is applicable when BUS:B<x>:SPI:FRAMING is set to IDLEtime. When the trigger condition is set to STARTofframe, the instrument triggers on the first SPI clock after an idle time when there are no clocks.
  • MISO specifies the Master-In Slave-Out condition.
  • MOSI specifies the Master-Out Slave-In condition.
  • MISOMOSI specifies the Master-In Slave-Out and Master-Out Slave-In conditions.

data property

Return the TRIGger:A:BUS:B<x>:SPI:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .size: The TRIGger:A:BUS:B<x>:SPI:DATa:SIZe command.
  • .in: The TRIGger:A:BUS:B<x>:SPI:DATa:IN command tree.
  • .miso: The TRIGger:A:BUS:B<x>:SPI:DATa:MISO command tree.
  • .out: The TRIGger:A:BUS:B<x>:SPI:DATa:OUT command tree.
  • .mosi: The TRIGger:A:BUS:B<x>:SPI:DATa:MOSI command tree.

TriggerABusBItemSpiCondition

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:SPI:CONDition command.

Description
  • This command specifies the trigger condition for a SPI trigger. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SPI:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SPI:CONDition {SS|STARTofframe|MISO|MOSI|MISOMOSI}
- TRIGger:A:BUS:B<x>:SPI:CONDition?
Info
  • SS specifies the Slave Selection condition.
  • STARTofframe is applicable when BUS:B<x>:SPI:FRAMING is set to IDLEtime. When the trigger condition is set to STARTofframe, the instrument triggers on the first SPI clock after an idle time when there are no clocks.
  • MISO specifies the Master-In Slave-Out condition.
  • MOSI specifies the Master-Out Slave-In condition.
  • MISOMOSI specifies the Master-In Slave-Out and Master-Out Slave-In conditions.

TriggerABusBItemSpiData

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:SPI:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa? query and raise an AssertionError if the returned value does not match value.
Properties
  • .size: The TRIGger:A:BUS:B<x>:SPI:DATa:SIZe command.
  • .in: The TRIGger:A:BUS:B<x>:SPI:DATa:IN command tree.
  • .miso: The TRIGger:A:BUS:B<x>:SPI:DATa:MISO command tree.
  • .out: The TRIGger:A:BUS:B<x>:SPI:DATa:OUT command tree.
  • .mosi: The TRIGger:A:BUS:B<x>:SPI:DATa:MOSI command tree.

in_ property

Return the TRIGger:A:BUS:B<x>:SPI:DATa:IN command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:IN? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:IN? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .value: The TRIGger:A:BUS:B<x>:SPI:DATa:IN:VALue command.

miso property

Return the TRIGger:A:BUS:B<x>:SPI:DATa:MISO command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MISO? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MISO? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .value: The TRIGger:A:BUS:B<x>:SPI:DATa:MISO:VALue command.

mosi property

Return the TRIGger:A:BUS:B<x>:SPI:DATa:MOSI command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MOSI? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MOSI? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .value: The TRIGger:A:BUS:B<x>:SPI:DATa:MOSI:VALue command.

out property

Return the TRIGger:A:BUS:B<x>:SPI:DATa:OUT command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:OUT? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:OUT? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .value: The TRIGger:A:BUS:B<x>:SPI:DATa:OUT:VALue command.

size property

Return the TRIGger:A:BUS:B<x>:SPI:DATa:SIZe command.

Description
  • This command specifies the length of the data string to be used for a SPI trigger if the trigger condition is DATa. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SPI:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:SPI:DATa:SIZe?
Info
  • <NR1> is the length of the data string in bytes.

TriggerABusBItemSpiDataIn

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:SPI:DATa:IN command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:IN? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:IN? query and raise an AssertionError if the returned value does not match value.
Properties
  • .value: The TRIGger:A:BUS:B<x>:SPI:DATa:IN:VALue command.

value property

Return the TRIGger:A:BUS:B<x>:SPI:DATa:IN:VALue command.

Description
  • This command specifies the binary data string to be used for a SPI trigger if the trigger condition is MISO or MISOMOSI. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:IN:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:IN:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:IN:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SPI:DATa:IN:VALue <QString>
- TRIGger:A:BUS:B<x>:SPI:DATa:IN:VALue?
Info
  • <QString> is the binary data string, where the number of bits is 8 times the number of bytes specified. The only allowed characters in the string are 0, 1, and X.

TriggerABusBItemSpiDataInValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:SPI:DATa:IN:VALue command.

Description
  • This command specifies the binary data string to be used for a SPI trigger if the trigger condition is MISO or MISOMOSI. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:IN:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:IN:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:IN:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SPI:DATa:IN:VALue <QString>
- TRIGger:A:BUS:B<x>:SPI:DATa:IN:VALue?
Info
  • <QString> is the binary data string, where the number of bits is 8 times the number of bytes specified. The only allowed characters in the string are 0, 1, and X.

TriggerABusBItemSpiDataMiso

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:SPI:DATa:MISO command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MISO? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MISO? query and raise an AssertionError if the returned value does not match value.
Properties
  • .value: The TRIGger:A:BUS:B<x>:SPI:DATa:MISO:VALue command.

value property

Return the TRIGger:A:BUS:B<x>:SPI:DATa:MISO:VALue command.

Description
  • This command specifies the binary data string to be used for a SPI trigger if the trigger condition is MISO or MISOMOSI. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MISO:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MISO:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MISO:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SPI:DATa:MISO:VALue <QString>
- TRIGger:A:BUS:B<x>:SPI:DATa:MISO:VALue?
Info
  • <QString> is the binary data string, where the number of bits is 8 times the number of bytes specified. The only allowed characters in the string are 0, 1, and X.

TriggerABusBItemSpiDataMisoValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:SPI:DATa:MISO:VALue command.

Description
  • This command specifies the binary data string to be used for a SPI trigger if the trigger condition is MISO or MISOMOSI. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MISO:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MISO:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MISO:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SPI:DATa:MISO:VALue <QString>
- TRIGger:A:BUS:B<x>:SPI:DATa:MISO:VALue?
Info
  • <QString> is the binary data string, where the number of bits is 8 times the number of bytes specified. The only allowed characters in the string are 0, 1, and X.

TriggerABusBItemSpiDataMosi

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:SPI:DATa:MOSI command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MOSI? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MOSI? query and raise an AssertionError if the returned value does not match value.
Properties
  • .value: The TRIGger:A:BUS:B<x>:SPI:DATa:MOSI:VALue command.

value property

Return the TRIGger:A:BUS:B<x>:SPI:DATa:MOSI:VALue command.

Description
  • This command specifies the binary data string to be used for a SPI trigger if the trigger condition is MOSI or MISOMOSI. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MOSI:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MOSI:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MOSI:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SPI:DATa:MOSI:VALue <QString>
- TRIGger:A:BUS:B<x>:SPI:DATa:MOSI:VALue?
Info
  • <QString> is the binary data string with the number of bits specified by the TRIGGER:A:BUS:BX:SPI:DATA:SIZE command. The only allowed characters in the QString are 0, 1, and X.

TriggerABusBItemSpiDataMosiValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:SPI:DATa:MOSI:VALue command.

Description
  • This command specifies the binary data string to be used for a SPI trigger if the trigger condition is MOSI or MISOMOSI. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MOSI:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MOSI:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:MOSI:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SPI:DATa:MOSI:VALue <QString>
- TRIGger:A:BUS:B<x>:SPI:DATa:MOSI:VALue?
Info
  • <QString> is the binary data string with the number of bits specified by the TRIGGER:A:BUS:BX:SPI:DATA:SIZE command. The only allowed characters in the QString are 0, 1, and X.

TriggerABusBItemSpiDataOut

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:SPI:DATa:OUT command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:OUT? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:OUT? query and raise an AssertionError if the returned value does not match value.
Properties
  • .value: The TRIGger:A:BUS:B<x>:SPI:DATa:OUT:VALue command.

value property

Return the TRIGger:A:BUS:B<x>:SPI:DATa:OUT:VALue command.

Description
  • This command specifies the binary data string to be used for a SPI trigger if the trigger condition is MOSI or MISOMOSI. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:OUT:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:OUT:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:OUT:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SPI:DATa:OUT:VALue <QString>
- TRIGger:A:BUS:B<x>:SPI:DATa:OUT:VALue?
Info
  • <QString> is the binary data string with the number of bits specified by the TRIGGER:A:BUS:BX:SPI:DATA:SIZE command. The only allowed characters in the QString are 0, 1, and X.

TriggerABusBItemSpiDataOutValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:SPI:DATa:OUT:VALue command.

Description
  • This command specifies the binary data string to be used for a SPI trigger if the trigger condition is MOSI or MISOMOSI. B
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:OUT:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:OUT:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:OUT:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SPI:DATa:OUT:VALue <QString>
- TRIGger:A:BUS:B<x>:SPI:DATa:OUT:VALue?
Info
  • <QString> is the binary data string with the number of bits specified by the TRIGGER:A:BUS:BX:SPI:DATA:SIZE command. The only allowed characters in the QString are 0, 1, and X.

TriggerABusBItemSpiDataSize

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:SPI:DATa:SIZe command.

Description
  • This command specifies the length of the data string to be used for a SPI trigger if the trigger condition is DATa. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SPI:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:SPI:DATa:SIZe?
Info
  • <NR1> is the length of the data string in bytes.

TriggerABusSource

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:SOUrce command.

Description
  • This command specifies the source for a serial or parallel bus trigger, with the appropriate application module installed.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:SOUrce value command.
SCPI Syntax
- TRIGger:A:BUS:SOUrce {B<x>}
- TRIGger:A:BUS:SOUrce?
Info
  • B1 specifies the Bus 1 source.
  • B2 specifies the Bus 2 source.
  • B3 specifies the Bus 3 source.
  • B4 specifies the Bus 4 source.

TriggerAEdge

Bases: SCPICmdRead

The TRIGger:A:EDGE command.

Description
  • Returns the trigger source, coupling, and slope for the A edge trigger.
Usage
  • Using the .query() method will send the TRIGger:A:EDGE? query.
  • Using the .verify(value) method will send the TRIGger:A:EDGE? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:EDGE?
Properties
  • .coupling: The TRIGger:A:EDGE:COUPling command.
  • .slope: The TRIGger:A:EDGE:SLOpe command.
  • .source: The TRIGger:A:EDGE:SOUrce command.

coupling property

Return the TRIGger:A:EDGE:COUPling command.

Description
  • This command sets or queries the type of coupling for the edge trigger. This command is equivalent to selecting Edge from the Trigger Type drop-down in the Trigger setup context menu, and choosing from the Coupling drop-down list.
Usage
  • Using the .query() method will send the TRIGger:A:EDGE:COUPling? query.
  • Using the .verify(value) method will send the TRIGger:A:EDGE:COUPling? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:EDGE:COUPling value command.
SCPI Syntax
- TRIGger:A:EDGE:COUPling {DC|HFRej|LFRej|NOISErej}
- TRIGger:A:EDGE:COUPling?
Info
  • DC selects DC trigger coupling, which passes all input signals to the trigger circuitry.
  • HFRej coupling attenuates signals above 50 kHz before passing the signals to the trigger circuitry.
  • LFRej coupling attenuates signals below 80 kHz before passing the signals to the trigger circuitry.
  • NOISErej coupling provides stable triggering by increasing the trigger hysteresis. Increased hysteresis reduces the trigger sensitivity to noise but can require greater trigger signal amplitude.

slope property

Return the TRIGger:A:EDGE:SLOpe command.

Description
  • Sets or returns the slope for the A edge trigger.
Usage
  • Using the .query() method will send the TRIGger:A:EDGE:SLOpe? query.
  • Using the .verify(value) method will send the TRIGger:A:EDGE:SLOpe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:EDGE:SLOpe value command.
SCPI Syntax
- TRIGger:A:EDGE:SLOpe {RISe|FALL}
- TRIGger:A:EDGE:SLOpe?
Info
  • RISe specifies to trigger on the rising or positive edge of a signal.
  • FALL specifies to trigger on the falling or negative edge of a signal.

source property

Return the TRIGger:A:EDGE:SOUrce command.

Description
  • Sets or returns the source for the A edge trigger.
Usage
  • Using the .query() method will send the TRIGger:A:EDGE:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:EDGE:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:EDGE:SOUrce value command.
SCPI Syntax
- TRIGger:A:EDGE:SOUrce {CH<x>|D<x>|EXT|LINE|AUX}
- TRIGger:A:EDGE:SOUrce?
Info
  • CH<x> specifies an analog input channel as the A edge trigger source. x has a minimum of 1 and a maximum of 4.
  • D<x> specifies a digital input channel as the A edge trigger source. x has a minimum of 0 and a maximum of 15.
  • EXT specifies an external trigger using the Aux In connector located on the front panel of the oscilloscope.
  • LINE specifies the AC line as the trigger source.
  • AUX specifies the Auxiliary Input as the trigger source (if available on your oscilloscope).

TriggerAEdgeCoupling

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:EDGE:COUPling command.

Description
  • This command sets or queries the type of coupling for the edge trigger. This command is equivalent to selecting Edge from the Trigger Type drop-down in the Trigger setup context menu, and choosing from the Coupling drop-down list.
Usage
  • Using the .query() method will send the TRIGger:A:EDGE:COUPling? query.
  • Using the .verify(value) method will send the TRIGger:A:EDGE:COUPling? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:EDGE:COUPling value command.
SCPI Syntax
- TRIGger:A:EDGE:COUPling {DC|HFRej|LFRej|NOISErej}
- TRIGger:A:EDGE:COUPling?
Info
  • DC selects DC trigger coupling, which passes all input signals to the trigger circuitry.
  • HFRej coupling attenuates signals above 50 kHz before passing the signals to the trigger circuitry.
  • LFRej coupling attenuates signals below 80 kHz before passing the signals to the trigger circuitry.
  • NOISErej coupling provides stable triggering by increasing the trigger hysteresis. Increased hysteresis reduces the trigger sensitivity to noise but can require greater trigger signal amplitude.

TriggerAEdgeSlope

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:EDGE:SLOpe command.

Description
  • Sets or returns the slope for the A edge trigger.
Usage
  • Using the .query() method will send the TRIGger:A:EDGE:SLOpe? query.
  • Using the .verify(value) method will send the TRIGger:A:EDGE:SLOpe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:EDGE:SLOpe value command.
SCPI Syntax
- TRIGger:A:EDGE:SLOpe {RISe|FALL}
- TRIGger:A:EDGE:SLOpe?
Info
  • RISe specifies to trigger on the rising or positive edge of a signal.
  • FALL specifies to trigger on the falling or negative edge of a signal.

TriggerAEdgeSource

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:EDGE:SOUrce command.

Description
  • Sets or returns the source for the A edge trigger.
Usage
  • Using the .query() method will send the TRIGger:A:EDGE:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:EDGE:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:EDGE:SOUrce value command.
SCPI Syntax
- TRIGger:A:EDGE:SOUrce {CH<x>|D<x>|EXT|LINE|AUX}
- TRIGger:A:EDGE:SOUrce?
Info
  • CH<x> specifies an analog input channel as the A edge trigger source. x has a minimum of 1 and a maximum of 4.
  • D<x> specifies a digital input channel as the A edge trigger source. x has a minimum of 0 and a maximum of 15.
  • EXT specifies an external trigger using the Aux In connector located on the front panel of the oscilloscope.
  • LINE specifies the AC line as the trigger source.
  • AUX specifies the Auxiliary Input as the trigger source (if available on your oscilloscope).

TriggerAHoldoff

Bases: SCPICmdRead

The TRIGger:A:HOLDoff command.

Description
  • Returns the A trigger holdoff parameters. These parameters specify the time period during which the trigger circuitry is not looking to generate a trigger event.
Usage
  • Using the .query() method will send the TRIGger:A:HOLDoff? query.
  • Using the .verify(value) method will send the TRIGger:A:HOLDoff? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:HOLDoff?
Properties
  • .time: The TRIGger:A:HOLDoff:TIMe command.

time property

Return the TRIGger:A:HOLDoff:TIMe command.

Description
  • This command sets or queries the A trigger holdoff time. This command is equivalent to selecting Mode & Holdoff from the Trig menu, selecting Time, and then setting the desired Holdoff Time.
Usage
  • Using the .query() method will send the TRIGger:A:HOLDoff:TIMe? query.
  • Using the .verify(value) method will send the TRIGger:A:HOLDoff:TIMe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:HOLDoff:TIMe value command.
SCPI Syntax
- TRIGger:A:HOLDoff:TIMe <NR3>
- TRIGger:A:HOLDoff:TIMe?
Info
  • <NR3> specifies the holdoff time in seconds. The range is from 0 seconds through 10 seconds.

TriggerAHoldoffTime

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:HOLDoff:TIMe command.

Description
  • This command sets or queries the A trigger holdoff time. This command is equivalent to selecting Mode & Holdoff from the Trig menu, selecting Time, and then setting the desired Holdoff Time.
Usage
  • Using the .query() method will send the TRIGger:A:HOLDoff:TIMe? query.
  • Using the .verify(value) method will send the TRIGger:A:HOLDoff:TIMe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:HOLDoff:TIMe value command.
SCPI Syntax
- TRIGger:A:HOLDoff:TIMe <NR3>
- TRIGger:A:HOLDoff:TIMe?
Info
  • <NR3> specifies the holdoff time in seconds. The range is from 0 seconds through 10 seconds.

TriggerALevel

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:LEVel command.

Description
  • Sets or returns the trigger level for the A trigger.
Usage
  • Using the .query() method will send the TRIGger:A:LEVel? query.
  • Using the .verify(value) method will send the TRIGger:A:LEVel? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LEVel value command.
SCPI Syntax
- TRIGger:A:LEVel {ECL|TTL|<NR3>}
- TRIGger:A:LEVel?
Info
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.
  • <NR3> specifies the trigger level in user units (usually volts).
Properties
  • .auxin: The TRIGger:A:LEVel:AUXin command.
  • .ch: The TRIGger:A:LEVel:CH<x> command.
  • .d: The TRIGger:A:LEVel:D<x> command.

auxin property

Return the TRIGger:A:LEVel:AUXin command.

Description
  • This command sets the threshold voltage level to use for an Edge, Pulse Width, Runt or Rise/Fall (aka Transition, aka Slew Rate) trigger when triggering on the Aux Input connector signal.
Usage
  • Using the .query() method will send the TRIGger:A:LEVel:AUXin? query.
  • Using the .verify(value) method will send the TRIGger:A:LEVel:AUXin? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LEVel:AUXin value command.
SCPI Syntax
- TRIGger:A:LEVel:AUXin {<NR3>|ECL|TTL}
- TRIGger:A:LEVel:AUXin?
Info
  • <NR3> is a floating point number that sets the trigger threshold level, in Volts, for the Aux Input connector.
  • ECL sets the threshold level to a preset ECL high level of -1.3V.
  • TTL sets the threshold level to a preset TTL high level of 1.4V.

ch property

Return the TRIGger:A:LEVel:CH<x> command.

Description
  • Sets or returns the trigger level for the specified channel. Each channel can have an independent level.
Usage
  • Using the .query() method will send the TRIGger:A:LEVel:CH<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LEVel:CH<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LEVel:CH<x> value command.
SCPI Syntax
- TRIGger:A:LEVel:CH<x> {<NR3>|TTL|ECL}
- TRIGger:A:LEVel:CH<x>?
Info
  • <NR3> specifies the trigger level in user units (usually volts).
  • TTL specifies a preset TTL high level of 1.4 V.
  • ECL specifies a preset ECL high level of -1.3 V.

d property

Return the TRIGger:A:LEVel:D<x> command.

Description
  • This command sets the threshold voltage level to use for an Edge or Pulse Width trigger when triggering on a digital channel waveform. can be 1 - 16. Each channel can have an independent trigger level.
Usage
  • Using the .query() method will send the TRIGger:A:LEVel:D<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LEVel:D<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LEVel:D<x> value command.
SCPI Syntax
- TRIGger:A:LEVel:D<x> {<NR3>|ECL|TTL}
- TRIGger:A:LEVel:D<x>?
Info
  • <NR3> is a floating point number that sets the trigger threshold level, in Volts, for the specified digital channel.
  • ECL sets the threshold level to a preset ECL high level of -1.3V.
  • TTL sets the threshold level to a preset TTL high level of 1.4V.

TriggerALevelAuxin

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:LEVel:AUXin command.

Description
  • This command sets the threshold voltage level to use for an Edge, Pulse Width, Runt or Rise/Fall (aka Transition, aka Slew Rate) trigger when triggering on the Aux Input connector signal.
Usage
  • Using the .query() method will send the TRIGger:A:LEVel:AUXin? query.
  • Using the .verify(value) method will send the TRIGger:A:LEVel:AUXin? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LEVel:AUXin value command.
SCPI Syntax
- TRIGger:A:LEVel:AUXin {<NR3>|ECL|TTL}
- TRIGger:A:LEVel:AUXin?
Info
  • <NR3> is a floating point number that sets the trigger threshold level, in Volts, for the Aux Input connector.
  • ECL sets the threshold level to a preset ECL high level of -1.3V.
  • TTL sets the threshold level to a preset TTL high level of 1.4V.

TriggerALevelChannel

Bases: ValidatedChannel, SCPICmdWrite, SCPICmdRead

The TRIGger:A:LEVel:CH<x> command.

Description
  • Sets or returns the trigger level for the specified channel. Each channel can have an independent level.
Usage
  • Using the .query() method will send the TRIGger:A:LEVel:CH<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LEVel:CH<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LEVel:CH<x> value command.
SCPI Syntax
- TRIGger:A:LEVel:CH<x> {<NR3>|TTL|ECL}
- TRIGger:A:LEVel:CH<x>?
Info
  • <NR3> specifies the trigger level in user units (usually volts).
  • TTL specifies a preset TTL high level of 1.4 V.
  • ECL specifies a preset ECL high level of -1.3 V.

TriggerALevelDigitalBit

Bases: ValidatedDigitalBit, SCPICmdWrite, SCPICmdRead

The TRIGger:A:LEVel:D<x> command.

Description
  • This command sets the threshold voltage level to use for an Edge or Pulse Width trigger when triggering on a digital channel waveform. can be 1 - 16. Each channel can have an independent trigger level.
Usage
  • Using the .query() method will send the TRIGger:A:LEVel:D<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LEVel:D<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LEVel:D<x> value command.
SCPI Syntax
- TRIGger:A:LEVel:D<x> {<NR3>|ECL|TTL}
- TRIGger:A:LEVel:D<x>?
Info
  • <NR3> is a floating point number that sets the trigger threshold level, in Volts, for the specified digital channel.
  • ECL sets the threshold level to a preset ECL high level of -1.3V.
  • TTL sets the threshold level to a preset TTL high level of 1.4V.

TriggerALogic

Bases: SCPICmdRead

The TRIGger:A:LOGIc command.

Description
  • Returns all of the A logic trigger parameters.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:LOGIc?
Properties
  • .class: The TRIGger:A:LOGIc:CLAss command.
  • .function: The TRIGger:A:LOGIc:FUNCtion command.
  • .input: The TRIGger:A:LOGIc:INPut command.
  • .pattern: The TRIGger:A:LOGIc:PATtern command.
  • .threshold: The TRIGger:A:LOGIc:THReshold command tree.

class_ property

Return the TRIGger:A:LOGIc:CLAss command.

Description
  • This command specifies what kind of logic trigger to use (either logic or setup/hold). You also need to set the trigger type to LOGIC using the command TRIGGER:A:TYPE. The LOGIC argument sets the oscilloscope to trigger on logical combinations of the channels (set using the TRIGger:A:LOGIc:INPut commands as well as TRIGGER:A:LOGIC:FUNCTION). You can use up to 20 channels for a logic trigger (4 analog and 16 digital). You can perform logic triggering using a clock; when TRIGGER:A:LOGIC:INPUT:CLOCK:SOURCE is set to one of the channels, the oscilloscope triggers when the specified logical combination of the remaining channels is true during a transition on the clock channel. You can also perform logic triggering without using a clock (by setting TRIGGER:A:LOGIC:INPUT:CLOCK:SOURCE to NONE ), so that the oscilloscope triggers when the specified logical combination of data channels is met. Without a clock, you can also use the command TRIGGER:A:LOGIC:PATTERN:DELTATIME. The SETHold argument sets the oscilloscope to trigger on setup and hold violations between a data source and a clock source. The clocking and data levels are used to determine if a clock or data transition has occurred. You can use up to 20 channels as Setup and Hold trigger data sources (4 analog and 16 digital) using TRIGGER:A:SETHOLD:DATA:SOURCE. You can use one channel input as the clock signal (TRIGGER:A:SETHOLD:CLOCK:SOURCE). The data sources cannot include the waveform specified for the clock source.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:CLAss? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:CLAss? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:CLAss value command.
SCPI Syntax
- TRIGger:A:LOGIc:CLAss {LOGIC|SETHold}
- TRIGger:A:LOGIc:CLAss?
Info
  • LOGIC - Use with the commands TRIGGER:A:LOGIC:FUNCTION, TRIGGER:A:LOGIC:INPUT:CHX, TRIGGER:A:LOGIC:INPUT:CLOCK:EDGE, TRIGGER:A:LOGIC:INPUT:CLOCK:SOURCE, TRIGGER:A:LOGIC:INPUT:DX, and TRIGGER:A:LOGIC:INPUT:RF. If you would like to use the logic trigger without a clock, you can also use the command TRIGGER:A:LOGIC:PATTERN:DELTATIME.
  • SETHold - Use with the commands TRIGGER:A:SETHOLD:CLOCK:EDGE, TRIGGER:A:SETHOLD:CLOCK:SOURCE, TRIGGER:A:SETHOLD:CLOCK:THRESHOLD, TRIGGER:A:SETHOLD:DATA:SOURCE.

function property

Return the TRIGger:A:LOGIc:FUNCtion command.

Description
  • Sets or returns the logical combination of the input channels for the A pattern and A state logic triggers.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:FUNCtion? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:FUNCtion? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:FUNCtion value command.
SCPI Syntax
- TRIGger:A:LOGIc:FUNCtion {AND|NANd}
- TRIGger:A:LOGIc:FUNCtion?
Info
  • AND specifies to trigger if all conditions are true.
  • NANd specifies to trigger if any of the conditions is false.

input property

Return the TRIGger:A:LOGIc:INPut command.

Description
  • Returns the logic input values for all channels. If a clock channel is defined, it returns the clock source and edge.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:INPut? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:INPut? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:LOGIc:INPut?
Sub-properties
  • .ch: The TRIGger:A:LOGIc:INPut:CH<x> command.
  • .clock: The TRIGger:A:LOGIc:INPut:CLOCk command tree.
  • .d: The TRIGger:A:LOGIc:INPut:D<x> command.

pattern property

Return the TRIGger:A:LOGIc:PATtern command.

Description
  • Returns the conditions used for generating an A logic pattern trigger, with respect to the defined input pattern, and identifies the time that the selected pattern may be true and still generate the trigger.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:PATtern? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:PATtern? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:LOGIc:PATtern?
Sub-properties
  • .deltatime: The TRIGger:A:LOGIc:PATtern:DELTatime command.
  • .input: The TRIGger:A:LOGIc:PATtern:INPut command tree.
  • .when: The TRIGger:A:LOGIc:PATtern:WHEn command.

threshold property

Return the TRIGger:A:LOGIc:THReshold command tree.

Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:THReshold? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:THReshold? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .d: The TRIGger:A:LOGIc:THReshold:D<x> command.
  • .ch: The TRIGger:A:LOGIc:THReshold:CH<x> command.

TriggerALogicClass

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOGIc:CLAss command.

Description
  • This command specifies what kind of logic trigger to use (either logic or setup/hold). You also need to set the trigger type to LOGIC using the command TRIGGER:A:TYPE. The LOGIC argument sets the oscilloscope to trigger on logical combinations of the channels (set using the TRIGger:A:LOGIc:INPut commands as well as TRIGGER:A:LOGIC:FUNCTION). You can use up to 20 channels for a logic trigger (4 analog and 16 digital). You can perform logic triggering using a clock; when TRIGGER:A:LOGIC:INPUT:CLOCK:SOURCE is set to one of the channels, the oscilloscope triggers when the specified logical combination of the remaining channels is true during a transition on the clock channel. You can also perform logic triggering without using a clock (by setting TRIGGER:A:LOGIC:INPUT:CLOCK:SOURCE to NONE ), so that the oscilloscope triggers when the specified logical combination of data channels is met. Without a clock, you can also use the command TRIGGER:A:LOGIC:PATTERN:DELTATIME. The SETHold argument sets the oscilloscope to trigger on setup and hold violations between a data source and a clock source. The clocking and data levels are used to determine if a clock or data transition has occurred. You can use up to 20 channels as Setup and Hold trigger data sources (4 analog and 16 digital) using TRIGGER:A:SETHOLD:DATA:SOURCE. You can use one channel input as the clock signal (TRIGGER:A:SETHOLD:CLOCK:SOURCE). The data sources cannot include the waveform specified for the clock source.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:CLAss? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:CLAss? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:CLAss value command.
SCPI Syntax
- TRIGger:A:LOGIc:CLAss {LOGIC|SETHold}
- TRIGger:A:LOGIc:CLAss?
Info
  • LOGIC - Use with the commands TRIGGER:A:LOGIC:FUNCTION, TRIGGER:A:LOGIC:INPUT:CHX, TRIGGER:A:LOGIC:INPUT:CLOCK:EDGE, TRIGGER:A:LOGIC:INPUT:CLOCK:SOURCE, TRIGGER:A:LOGIC:INPUT:DX, and TRIGGER:A:LOGIC:INPUT:RF. If you would like to use the logic trigger without a clock, you can also use the command TRIGGER:A:LOGIC:PATTERN:DELTATIME.
  • SETHold - Use with the commands TRIGGER:A:SETHOLD:CLOCK:EDGE, TRIGGER:A:SETHOLD:CLOCK:SOURCE, TRIGGER:A:SETHOLD:CLOCK:THRESHOLD, TRIGGER:A:SETHOLD:DATA:SOURCE.

TriggerALogicFunction

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOGIc:FUNCtion command.

Description
  • Sets or returns the logical combination of the input channels for the A pattern and A state logic triggers.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:FUNCtion? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:FUNCtion? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:FUNCtion value command.
SCPI Syntax
- TRIGger:A:LOGIc:FUNCtion {AND|NANd}
- TRIGger:A:LOGIc:FUNCtion?
Info
  • AND specifies to trigger if all conditions are true.
  • NANd specifies to trigger if any of the conditions is false.

TriggerALogicInput

Bases: SCPICmdRead

The TRIGger:A:LOGIc:INPut command.

Description
  • Returns the logic input values for all channels. If a clock channel is defined, it returns the clock source and edge.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:INPut? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:INPut? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:LOGIc:INPut?
Properties
  • .ch: The TRIGger:A:LOGIc:INPut:CH<x> command.
  • .clock: The TRIGger:A:LOGIc:INPut:CLOCk command tree.
  • .d: The TRIGger:A:LOGIc:INPut:D<x> command.

ch property

Return the TRIGger:A:LOGIc:INPut:CH<x> command.

Description
  • This command specifies the logical input condition for the channel specified by .
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:INPut:CH<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:INPut:CH<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:INPut:CH<x> value command.
SCPI Syntax
- TRIGger:A:LOGIc:INPut:CH<x> {HIGH|LOW|X}
- TRIGger:A:LOGIc:INPut:CH<x>?
Info
  • HIGH specifies the logic high.
  • LOW specifies the logic low.
  • X specifies a ‘don’t care’ state.

clock property

Return the TRIGger:A:LOGIc:INPut:CLOCk command tree.

Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:INPut:CLOCk? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:INPut:CLOCk? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .edge: The TRIGger:A:LOGIc:INPut:CLOCk:EDGE command.
  • .source: The TRIGger:A:LOGIc:INPut:CLOCk:SOUrce command.

d property

Return the TRIGger:A:LOGIc:INPut:D<x> command.

Description
  • This command specifies the logic pattern for a trigger on digital channel , where x is the channel number.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:INPut:D<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:INPut:D<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:INPut:D<x> value command.
SCPI Syntax
- TRIGger:A:LOGIc:INPut:D<x> {HIGH|LOW|X}
- TRIGger:A:LOGIc:INPut:D<x>?
Info
  • High specifies the logic high state.
  • Low specifies the logic low state.
  • X specifies a ‘don’t care’ state.

TriggerALogicInputChannel

Bases: ValidatedChannel, SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOGIc:INPut:CH<x> command.

Description
  • This command specifies the logical input condition for the channel specified by .
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:INPut:CH<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:INPut:CH<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:INPut:CH<x> value command.
SCPI Syntax
- TRIGger:A:LOGIc:INPut:CH<x> {HIGH|LOW|X}
- TRIGger:A:LOGIc:INPut:CH<x>?
Info
  • HIGH specifies the logic high.
  • LOW specifies the logic low.
  • X specifies a ‘don’t care’ state.

TriggerALogicInputClock

Bases: SCPICmdRead

The TRIGger:A:LOGIc:INPut:CLOCk command tree.

Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:INPut:CLOCk? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:INPut:CLOCk? query and raise an AssertionError if the returned value does not match value.
Properties
  • .edge: The TRIGger:A:LOGIc:INPut:CLOCk:EDGE command.
  • .source: The TRIGger:A:LOGIc:INPut:CLOCk:SOUrce command.

edge property

Return the TRIGger:A:LOGIc:INPut:CLOCk:EDGE command.

Description
  • Sets the polarity of the clock channel.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:INPut:CLOCk:EDGE? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:INPut:CLOCk:EDGE? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:INPut:CLOCk:EDGE value command.
SCPI Syntax
- TRIGger:A:LOGIc:INPut:CLOCk:EDGE {FALL|RISe|EITher}
- TRIGger:A:LOGIc:INPut:CLOCk:EDGE?
Info
  • RISe specifies to trigger on the rising or positive edge of a signal.
  • FALL specifies to trigger on the falling or negative edge of a signal.
  • EITher specifies to trigger either on the falling or rising edge of a signal.

source property

Return the TRIGger:A:LOGIc:INPut:CLOCk:SOUrce command.

Description
  • Sets or returns the channel to use as the clock source. The clock can be selected as NONE. A selection of None implies pattern trigger. Any other selection implies state trigger.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:INPut:CLOCk:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:INPut:CLOCk:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:INPut:CLOCk:SOUrce value command.
SCPI Syntax
- TRIGger:A:LOGIc:INPut:CLOCk:SOUrce {CH<x>|D<x>|NONE}
- TRIGger:A:LOGIc:INPut:CLOCk:SOUrce?
Info
  • CH<x> specifies the analog input channel source. x has a minimum of 1 and a maximum of 4.
  • D<x> specifies the digital input channel source. x has a minimum of 0 and a maximum of 15.
  • NONE specifies a Pattern trigger.

TriggerALogicInputClockEdge

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOGIc:INPut:CLOCk:EDGE command.

Description
  • Sets the polarity of the clock channel.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:INPut:CLOCk:EDGE? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:INPut:CLOCk:EDGE? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:INPut:CLOCk:EDGE value command.
SCPI Syntax
- TRIGger:A:LOGIc:INPut:CLOCk:EDGE {FALL|RISe|EITher}
- TRIGger:A:LOGIc:INPut:CLOCk:EDGE?
Info
  • RISe specifies to trigger on the rising or positive edge of a signal.
  • FALL specifies to trigger on the falling or negative edge of a signal.
  • EITher specifies to trigger either on the falling or rising edge of a signal.

TriggerALogicInputClockSource

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOGIc:INPut:CLOCk:SOUrce command.

Description
  • Sets or returns the channel to use as the clock source. The clock can be selected as NONE. A selection of None implies pattern trigger. Any other selection implies state trigger.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:INPut:CLOCk:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:INPut:CLOCk:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:INPut:CLOCk:SOUrce value command.
SCPI Syntax
- TRIGger:A:LOGIc:INPut:CLOCk:SOUrce {CH<x>|D<x>|NONE}
- TRIGger:A:LOGIc:INPut:CLOCk:SOUrce?
Info
  • CH<x> specifies the analog input channel source. x has a minimum of 1 and a maximum of 4.
  • D<x> specifies the digital input channel source. x has a minimum of 0 and a maximum of 15.
  • NONE specifies a Pattern trigger.

TriggerALogicInputDigitalBit

Bases: ValidatedDigitalBit, SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOGIc:INPut:D<x> command.

Description
  • This command specifies the logic pattern for a trigger on digital channel , where x is the channel number.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:INPut:D<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:INPut:D<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:INPut:D<x> value command.
SCPI Syntax
- TRIGger:A:LOGIc:INPut:D<x> {HIGH|LOW|X}
- TRIGger:A:LOGIc:INPut:D<x>?
Info
  • High specifies the logic high state.
  • Low specifies the logic low state.
  • X specifies a ‘don’t care’ state.

TriggerALogicPattern

Bases: SCPICmdRead

The TRIGger:A:LOGIc:PATtern command.

Description
  • Returns the conditions used for generating an A logic pattern trigger, with respect to the defined input pattern, and identifies the time that the selected pattern may be true and still generate the trigger.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:PATtern? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:PATtern? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:LOGIc:PATtern?
Properties
  • .deltatime: The TRIGger:A:LOGIc:PATtern:DELTatime command.
  • .input: The TRIGger:A:LOGIc:PATtern:INPut command tree.
  • .when: The TRIGger:A:LOGIc:PATtern:WHEn command.

deltatime property

Return the TRIGger:A:LOGIc:PATtern:DELTatime command.

Description
  • This command specifies the pattern trigger delta time value. The time value is used as part of the pattern trigger condition to determine if the duration of a logic pattern meets the specified time constraints.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:PATtern:DELTatime? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:PATtern:DELTatime? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:PATtern:DELTatime value command.
SCPI Syntax
- TRIGger:A:LOGIc:PATtern:DELTatime <NR3>
- TRIGger:A:LOGIc:PATtern:DELTatime?
Info
  • <NR3> is a floating point value with exponent that sets the pattern trigger time value. This argument has a range of 39.6E-9 (39.6 ns) to 10.0E0 (10 s), in increments of 13.2 ns. Values that are not an increment of 13.2 ns are rounded to the nearest correct value.

input property

Return the TRIGger:A:LOGIc:PATtern:INPut command tree.

Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:PATtern:INPut? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:PATtern:INPut? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .d: The TRIGger:A:LOGIc:PATtern:INPut:D<x> command.

when property

Return the TRIGger:A:LOGIc:PATtern:WHEn command.

Description
  • Sets or returns the pattern logic condition on which to trigger the oscilloscope.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:PATtern:WHEn? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:PATtern:WHEn? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:PATtern:WHEn value command.
SCPI Syntax
- TRIGger:A:LOGIc:PATtern:WHEn {TRUe|FALSe|LESSThan|MOREThan|EQUal|UNEQual}
- TRIGger:A:LOGIc:PATtern:WHEn?
Info
  • TRUE triggers the oscilloscope when the pattern becomes true.
  • FALSE triggers the oscilloscope when the pattern becomes false.
  • LESSTHAN triggers the oscilloscope when the input pattern is true for a time period less than the time period specified in TRIGGER:A:LOGIC:PATTERN:DELTATIME.
  • MORETHAN triggers the oscilloscope when the input pattern is true for a time period more (greater) than the time period specified in TRIGGER:A:LOGIC:PATTERN:DELTATIME.
  • EQUAL triggers the oscilloscope when the input pattern is true for a time period equal to the time period specified in TRIGGER:A:LOGIC:PATTERN:DELTATIME, within a ±5% tolerance.
  • UNEQUAL triggers the oscilloscope when the input pattern is true for a time period greater than or less than (not equal to) the time period specified in TRIGGER:A:LOGIC:PATTERN:DELTATIME, within a ±5% tolerance.
Sub-properties
  • .lesslimit: The TRIGger:A:LOGIc:PATtern:WHEn:LESSLimit command.
  • .morelimit: The TRIGger:A:LOGIc:PATtern:WHEn:MORELimit command.

TriggerALogicPatternDeltatime

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOGIc:PATtern:DELTatime command.

Description
  • This command specifies the pattern trigger delta time value. The time value is used as part of the pattern trigger condition to determine if the duration of a logic pattern meets the specified time constraints.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:PATtern:DELTatime? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:PATtern:DELTatime? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:PATtern:DELTatime value command.
SCPI Syntax
- TRIGger:A:LOGIc:PATtern:DELTatime <NR3>
- TRIGger:A:LOGIc:PATtern:DELTatime?
Info
  • <NR3> is a floating point value with exponent that sets the pattern trigger time value. This argument has a range of 39.6E-9 (39.6 ns) to 10.0E0 (10 s), in increments of 13.2 ns. Values that are not an increment of 13.2 ns are rounded to the nearest correct value.

TriggerALogicPatternInput

Bases: SCPICmdRead

The TRIGger:A:LOGIc:PATtern:INPut command tree.

Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:PATtern:INPut? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:PATtern:INPut? query and raise an AssertionError if the returned value does not match value.
Properties
  • .d: The TRIGger:A:LOGIc:PATtern:INPut:D<x> command.

d property

Return the TRIGger:A:LOGIc:PATtern:INPut:D<x> command.

Description
  • Sets or returns the A logic trigger input for the specified digital channel , where x is the channel number. This command species the logic value used when the pattern trigger detects the threshold level.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:PATtern:INPut:D<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:PATtern:INPut:D<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:PATtern:INPut:D<x> value command.
SCPI Syntax
- TRIGger:A:LOGIc:PATtern:INPut:D<x> {HIGH|LOW|X}
- TRIGger:A:LOGIc:PATtern:INPut:D<x>?
Info
  • HIGH specifies a logic high.
  • LOW specifies a logic low.
  • X specifies a ‘do not care’ state.

TriggerALogicPatternInputDigitalBit

Bases: ValidatedDigitalBit, SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOGIc:PATtern:INPut:D<x> command.

Description
  • Sets or returns the A logic trigger input for the specified digital channel , where x is the channel number. This command species the logic value used when the pattern trigger detects the threshold level.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:PATtern:INPut:D<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:PATtern:INPut:D<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:PATtern:INPut:D<x> value command.
SCPI Syntax
- TRIGger:A:LOGIc:PATtern:INPut:D<x> {HIGH|LOW|X}
- TRIGger:A:LOGIc:PATtern:INPut:D<x>?
Info
  • HIGH specifies a logic high.
  • LOW specifies a logic low.
  • X specifies a ‘do not care’ state.

TriggerALogicPatternWhen

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOGIc:PATtern:WHEn command.

Description
  • Sets or returns the pattern logic condition on which to trigger the oscilloscope.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:PATtern:WHEn? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:PATtern:WHEn? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:PATtern:WHEn value command.
SCPI Syntax
- TRIGger:A:LOGIc:PATtern:WHEn {TRUe|FALSe|LESSThan|MOREThan|EQUal|UNEQual}
- TRIGger:A:LOGIc:PATtern:WHEn?
Info
  • TRUE triggers the oscilloscope when the pattern becomes true.
  • FALSE triggers the oscilloscope when the pattern becomes false.
  • LESSTHAN triggers the oscilloscope when the input pattern is true for a time period less than the time period specified in TRIGGER:A:LOGIC:PATTERN:DELTATIME.
  • MORETHAN triggers the oscilloscope when the input pattern is true for a time period more (greater) than the time period specified in TRIGGER:A:LOGIC:PATTERN:DELTATIME.
  • EQUAL triggers the oscilloscope when the input pattern is true for a time period equal to the time period specified in TRIGGER:A:LOGIC:PATTERN:DELTATIME, within a ±5% tolerance.
  • UNEQUAL triggers the oscilloscope when the input pattern is true for a time period greater than or less than (not equal to) the time period specified in TRIGGER:A:LOGIC:PATTERN:DELTATIME, within a ±5% tolerance.
Properties
  • .lesslimit: The TRIGger:A:LOGIc:PATtern:WHEn:LESSLimit command.
  • .morelimit: The TRIGger:A:LOGIc:PATtern:WHEn:MORELimit command.

lesslimit property

Return the TRIGger:A:LOGIc:PATtern:WHEn:LESSLimit command.

Description
  • Sets or returns the maximum time that the selected pattern may be true and still generate an A logic pattern trigger.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:PATtern:WHEn:LESSLimit? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:PATtern:WHEn:LESSLimit? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:PATtern:WHEn:LESSLimit value command.
SCPI Syntax
- TRIGger:A:LOGIc:PATtern:WHEn:LESSLimit <NR3>
- TRIGger:A:LOGIc:PATtern:WHEn:LESSLimit?
Info
  • <NR3> specifies the maximum amount of time to hold the pattern true.

morelimit property

Return the TRIGger:A:LOGIc:PATtern:WHEn:MORELimit command.

Description
  • Sets or returns the minimum time that the selected pattern may be true and still generate an A logic pattern trigger.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:PATtern:WHEn:MORELimit? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:PATtern:WHEn:MORELimit? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:PATtern:WHEn:MORELimit value command.
SCPI Syntax
- TRIGger:A:LOGIc:PATtern:WHEn:MORELimit <NR3>
- TRIGger:A:LOGIc:PATtern:WHEn:MORELimit?
Info
  • <NR3> specifies the minimum amount of time to hold the pattern true.

TriggerALogicPatternWhenLesslimit

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOGIc:PATtern:WHEn:LESSLimit command.

Description
  • Sets or returns the maximum time that the selected pattern may be true and still generate an A logic pattern trigger.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:PATtern:WHEn:LESSLimit? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:PATtern:WHEn:LESSLimit? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:PATtern:WHEn:LESSLimit value command.
SCPI Syntax
- TRIGger:A:LOGIc:PATtern:WHEn:LESSLimit <NR3>
- TRIGger:A:LOGIc:PATtern:WHEn:LESSLimit?
Info
  • <NR3> specifies the maximum amount of time to hold the pattern true.

TriggerALogicPatternWhenMorelimit

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOGIc:PATtern:WHEn:MORELimit command.

Description
  • Sets or returns the minimum time that the selected pattern may be true and still generate an A logic pattern trigger.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:PATtern:WHEn:MORELimit? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:PATtern:WHEn:MORELimit? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:PATtern:WHEn:MORELimit value command.
SCPI Syntax
- TRIGger:A:LOGIc:PATtern:WHEn:MORELimit <NR3>
- TRIGger:A:LOGIc:PATtern:WHEn:MORELimit?
Info
  • <NR3> specifies the minimum amount of time to hold the pattern true.

TriggerALogicThreshold

Bases: SCPICmdRead

The TRIGger:A:LOGIc:THReshold command tree.

Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:THReshold? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:THReshold? query and raise an AssertionError if the returned value does not match value.
Properties
  • .d: The TRIGger:A:LOGIc:THReshold:D<x> command.
  • .ch: The TRIGger:A:LOGIc:THReshold:CH<x> command.

ch property

Return the TRIGger:A:LOGIc:THReshold:CH<x> command.

Description
  • This command sets or queries the logic trigger threshold voltage for both analog and digital channels (for MSO models), specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:THReshold:CH<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:THReshold:CH<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:THReshold:CH<x> value command.
SCPI Syntax
- TRIGger:A:LOGIc:THReshold:CH<x> {<NR3>|ECL|TTL}
- TRIGger:A:LOGIc:THReshold:CH<x>?
Info
  • <NR3> specifies the threshold voltage, in volts.
  • ECL specifies a preset ECL high level of -1.3 V.
  • TTL specifies a preset TTL high level of 1.4 V.

d property

Return the TRIGger:A:LOGIc:THReshold:D<x> command.

Description
  • This command specifies the trigger A logic threshold level for the specified digital channel . This commands affects all trigger types using the digital channel.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:THReshold:D<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:THReshold:D<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:THReshold:D<x> value command.
SCPI Syntax
- TRIGger:A:LOGIc:THReshold:D<x> {<NR3>|ECL|TTL}
- TRIGger:A:LOGIc:THReshold:D<x>?
Info
  • <NR3> is a floating point number that specifies the threshold level in volts.
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.

TriggerALogicThresholdChannel

Bases: ValidatedChannel, SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOGIc:THReshold:CH<x> command.

Description
  • This command sets or queries the logic trigger threshold voltage for both analog and digital channels (for MSO models), specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:THReshold:CH<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:THReshold:CH<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:THReshold:CH<x> value command.
SCPI Syntax
- TRIGger:A:LOGIc:THReshold:CH<x> {<NR3>|ECL|TTL}
- TRIGger:A:LOGIc:THReshold:CH<x>?
Info
  • <NR3> specifies the threshold voltage, in volts.
  • ECL specifies a preset ECL high level of -1.3 V.
  • TTL specifies a preset TTL high level of 1.4 V.

TriggerALogicThresholdDigitalBit

Bases: ValidatedDigitalBit, SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOGIc:THReshold:D<x> command.

Description
  • This command specifies the trigger A logic threshold level for the specified digital channel . This commands affects all trigger types using the digital channel.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:THReshold:D<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:THReshold:D<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:THReshold:D<x> value command.
SCPI Syntax
- TRIGger:A:LOGIc:THReshold:D<x> {<NR3>|ECL|TTL}
- TRIGger:A:LOGIc:THReshold:D<x>?
Info
  • <NR3> is a floating point number that specifies the threshold level in volts.
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.

TriggerALowerthreshold

Bases: SCPICmdRead

The TRIGger:A:LOWerthreshold command tree.

Usage
  • Using the .query() method will send the TRIGger:A:LOWerthreshold? query.
  • Using the .verify(value) method will send the TRIGger:A:LOWerthreshold? query and raise an AssertionError if the returned value does not match value.
Properties
  • .ch: The TRIGger:A:LOWerthreshold:CH<x> command.
  • .ext: The TRIGger:A:LOWerthreshold:EXT command.
  • .aux: The TRIGger:A:LOWerthreshold:AUX command.

aux property

Return the TRIGger:A:LOWerthreshold:AUX command.

Description
  • Sets or returns the lower threshold for the Auxiliary Input. It is similar to TRIGGER:A:LEVEL:AUXIN.
Usage
  • Using the .query() method will send the TRIGger:A:LOWerthreshold:AUX? query.
  • Using the .verify(value) method will send the TRIGger:A:LOWerthreshold:AUX? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOWerthreshold:AUX value command.
SCPI Syntax
- TRIGger:A:LOWerthreshold:AUX {<NR3>|ECL|TTL}
- TRIGger:A:LOWerthreshold:AUX?
Info
  • ECL specifies a preset ECL high level of -1.3 V.
  • TTL specifies a preset TTL high level of 1.4 V.
  • <NR3> specifies the threshold level in volts.

ch property

Return the TRIGger:A:LOWerthreshold:CH<x> command.

Description
  • This command specifies the lower threshold for the channel selected. Each channel can have an independent level. Used in runt and transition triggers as the lower threshold. Used for all other trigger types as the single level/threshold.
Usage
  • Using the .query() method will send the TRIGger:A:LOWerthreshold:CH<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LOWerthreshold:CH<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOWerthreshold:CH<x> value command.
SCPI Syntax
- TRIGger:A:LOWerthreshold:CH<x> {ECL|TTL|<NR3>}
- TRIGger:A:LOWerthreshold:CH<x>?
Info
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.
  • <NR3> is a floating point number that specifies the clock level, in volts.

ext property

Return the TRIGger:A:LOWerthreshold:EXT command.

Description
  • Sets or returns the lower threshold for the Auxiliary Input. It is similar to TRIGGER:A:LEVEL:AUXIN.
Usage
  • Using the .query() method will send the TRIGger:A:LOWerthreshold:EXT? query.
  • Using the .verify(value) method will send the TRIGger:A:LOWerthreshold:EXT? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOWerthreshold:EXT value command.
SCPI Syntax
- TRIGger:A:LOWerthreshold:EXT {<NR3>|ECL|TTL}
- TRIGger:A:LOWerthreshold:EXT?
Info
  • ECL specifies a preset ECL high level of -1.3 V.
  • TTL specifies a preset TTL high level of 1.4 V.
  • <NR3> specifies the threshold level in volts.

TriggerALowerthresholdAux

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOWerthreshold:AUX command.

Description
  • Sets or returns the lower threshold for the Auxiliary Input. It is similar to TRIGGER:A:LEVEL:AUXIN.
Usage
  • Using the .query() method will send the TRIGger:A:LOWerthreshold:AUX? query.
  • Using the .verify(value) method will send the TRIGger:A:LOWerthreshold:AUX? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOWerthreshold:AUX value command.
SCPI Syntax
- TRIGger:A:LOWerthreshold:AUX {<NR3>|ECL|TTL}
- TRIGger:A:LOWerthreshold:AUX?
Info
  • ECL specifies a preset ECL high level of -1.3 V.
  • TTL specifies a preset TTL high level of 1.4 V.
  • <NR3> specifies the threshold level in volts.

TriggerALowerthresholdChannel

Bases: ValidatedChannel, SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOWerthreshold:CH<x> command.

Description
  • This command specifies the lower threshold for the channel selected. Each channel can have an independent level. Used in runt and transition triggers as the lower threshold. Used for all other trigger types as the single level/threshold.
Usage
  • Using the .query() method will send the TRIGger:A:LOWerthreshold:CH<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LOWerthreshold:CH<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOWerthreshold:CH<x> value command.
SCPI Syntax
- TRIGger:A:LOWerthreshold:CH<x> {ECL|TTL|<NR3>}
- TRIGger:A:LOWerthreshold:CH<x>?
Info
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.
  • <NR3> is a floating point number that specifies the clock level, in volts.

TriggerALowerthresholdExt

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOWerthreshold:EXT command.

Description
  • Sets or returns the lower threshold for the Auxiliary Input. It is similar to TRIGGER:A:LEVEL:AUXIN.
Usage
  • Using the .query() method will send the TRIGger:A:LOWerthreshold:EXT? query.
  • Using the .verify(value) method will send the TRIGger:A:LOWerthreshold:EXT? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOWerthreshold:EXT value command.
SCPI Syntax
- TRIGger:A:LOWerthreshold:EXT {<NR3>|ECL|TTL}
- TRIGger:A:LOWerthreshold:EXT?
Info
  • ECL specifies a preset ECL high level of -1.3 V.
  • TTL specifies a preset TTL high level of 1.4 V.
  • <NR3> specifies the threshold level in volts.

TriggerAMode

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:MODe command.

Description
  • This command sets or queries the A trigger mode. This command is equivalent to pushing the Mode button on the front panel.
Usage
  • Using the .query() method will send the TRIGger:A:MODe? query.
  • Using the .verify(value) method will send the TRIGger:A:MODe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:MODe value command.
SCPI Syntax
- TRIGger:A:MODe {AUTO|NORMal}
- TRIGger:A:MODe?
Info
  • AUTO generates a trigger if one is not detected within a specified time period.
  • NORMal waits for a valid trigger event.

TriggerAPulse

Bases: SCPICmdRead

The TRIGger:A:PULse command.

Description
  • Returns the A pulse trigger parameters.
Usage
  • Using the .query() method will send the TRIGger:A:PULse? query.
  • Using the .verify(value) method will send the TRIGger:A:PULse? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:PULse?
Properties
  • .class: The TRIGger:A:PULse:CLAss command.

class_ property

Return the TRIGger:A:PULse:CLAss command.

Description
  • Sets or returns the type of pulse on which to trigger.
Usage
  • Using the .query() method will send the TRIGger:A:PULse:CLAss? query.
  • Using the .verify(value) method will send the TRIGger:A:PULse:CLAss? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:PULse:CLAss value command.
SCPI Syntax
- TRIGger:A:PULse:CLAss {RUNt|WIDth|TRANsition}
- TRIGger:A:PULse:CLAss?
Info
  • RUNt triggers when a pulse crosses the first preset voltage threshold but does not cross the second preset threshold before recrossing the first.
  • WIDth triggers when a pulse is found that has the specified polarity and is either inside or outside the specified time limits.
  • TRAnsition triggers when a pulse crosses both thresholds in the same direction as the specified polarity and the transition time between the two threshold crossings is greater or less than the specified time delta.

TriggerAPulseClass

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:PULse:CLAss command.

Description
  • Sets or returns the type of pulse on which to trigger.
Usage
  • Using the .query() method will send the TRIGger:A:PULse:CLAss? query.
  • Using the .verify(value) method will send the TRIGger:A:PULse:CLAss? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:PULse:CLAss value command.
SCPI Syntax
- TRIGger:A:PULse:CLAss {RUNt|WIDth|TRANsition}
- TRIGger:A:PULse:CLAss?
Info
  • RUNt triggers when a pulse crosses the first preset voltage threshold but does not cross the second preset threshold before recrossing the first.
  • WIDth triggers when a pulse is found that has the specified polarity and is either inside or outside the specified time limits.
  • TRAnsition triggers when a pulse crosses both thresholds in the same direction as the specified polarity and the transition time between the two threshold crossings is greater or less than the specified time delta.

TriggerAPulsewidth

Bases: SCPICmdRead

The TRIGger:A:PULSEWidth command.

Description
  • Returns the width parameters for the pulse width trigger.
Usage
  • Using the .query() method will send the TRIGger:A:PULSEWidth? query.
  • Using the .verify(value) method will send the TRIGger:A:PULSEWidth? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:PULSEWidth?
Properties
  • .polarity: The TRIGger:A:PULSEWidth:POLarity command.
  • .source: The TRIGger:A:PULSEWidth:SOUrce command.
  • .when: The TRIGger:A:PULSEWidth:WHEn command.
  • .width: The TRIGger:A:PULSEWidth:Width command.

polarity property

Return the TRIGger:A:PULSEWidth:POLarity command.

Description
  • This command specifies the polarity for a pulse width trigger.
Usage
  • Using the .query() method will send the TRIGger:A:PULSEWidth:POLarity? query.
  • Using the .verify(value) method will send the TRIGger:A:PULSEWidth:POLarity? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:PULSEWidth:POLarity value command.
SCPI Syntax
- TRIGger:A:PULSEWidth:POLarity {NEGative|POSitive}
- TRIGger:A:PULSEWidth:POLarity?
Info
  • NEGative specifies a negative pulse.
  • POSitive specifies a positive pulse.

source property

Return the TRIGger:A:PULSEWidth:SOUrce command.

Description
  • Sets or returns the source for the pulse-width trigger.
Usage
  • Using the .query() method will send the TRIGger:A:PULSEWidth:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:PULSEWidth:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:PULSEWidth:SOUrce value command.
SCPI Syntax
- TRIGger:A:PULSEWidth:SOUrce {CH<x>|D<x>|LINE|EXT}
- TRIGger:A:PULSEWidth:SOUrce?
Info
  • CH<x> specifies an analog input channel as the A edge trigger source. x has a minimum of 1 and a maximum of 4.
  • D<x> specifies an digital input channel as the A edge trigger source. x has a minimum of 0 and a maximum of 15.
  • EXT specifies an external trigger using the Aux In connector located on the front panel of the oscilloscope.
  • LINE specifies AC line voltage.

when property

Return the TRIGger:A:PULSEWidth:WHEn command.

Description
  • Sets or returns whether to trigger on a pulse that meets, falls outside, or within the specified range of limits.
Usage
  • Using the .query() method will send the TRIGger:A:PULSEWidth:WHEn? query.
  • Using the .verify(value) method will send the TRIGger:A:PULSEWidth:WHEn? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:PULSEWidth:WHEn value command.
SCPI Syntax
- TRIGger:A:PULSEWidth:WHEn {LESSthan|MOREthan|EQual|UNEQual}
- TRIGger:A:PULSEWidth:WHEn?
Info
  • LESSthan argument sets the oscilloscope to trigger if a pulse is detected with width less than the time set by the TRIGGER:A:PULSEWIDTH:WIDTH command.
  • MOREthan argument sets the oscilloscope to trigger if a pulse is detected with width more than the time set by the TRIGGER:A:PULSEWIDTH:WIDTH command.
  • EQUal argument sets the oscilloscope to trigger if a pulse is detected with width equal to the time period specified in TRIGGER:A:PULSEWIDTH:WIDTH within a ±5% tolerance.
  • UNEQual argument sets the oscilloscope to trigger if a pulse is detected with width greater than or less than (but not equal) the time period specified in TRIGGER:A:PULSEWIDTH:WIDTH within a ±5% tolerance.

width property

Return the TRIGger:A:PULSEWidth:Width command.

Description
  • Sets or returns the width setting for the pulse width trigger.
Usage
  • Using the .query() method will send the TRIGger:A:PULSEWidth:Width? query.
  • Using the .verify(value) method will send the TRIGger:A:PULSEWidth:Width? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:PULSEWidth:Width value command.
SCPI Syntax
- TRIGger:A:PULSEWidth:Width <NR3>
- TRIGger:A:PULSEWidth:Width?
Info
  • <NR3> specifies the pulse width in seconds.

TriggerAPulsewidthPolarity

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:PULSEWidth:POLarity command.

Description
  • This command specifies the polarity for a pulse width trigger.
Usage
  • Using the .query() method will send the TRIGger:A:PULSEWidth:POLarity? query.
  • Using the .verify(value) method will send the TRIGger:A:PULSEWidth:POLarity? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:PULSEWidth:POLarity value command.
SCPI Syntax
- TRIGger:A:PULSEWidth:POLarity {NEGative|POSitive}
- TRIGger:A:PULSEWidth:POLarity?
Info
  • NEGative specifies a negative pulse.
  • POSitive specifies a positive pulse.

TriggerAPulsewidthSource

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:PULSEWidth:SOUrce command.

Description
  • Sets or returns the source for the pulse-width trigger.
Usage
  • Using the .query() method will send the TRIGger:A:PULSEWidth:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:PULSEWidth:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:PULSEWidth:SOUrce value command.
SCPI Syntax
- TRIGger:A:PULSEWidth:SOUrce {CH<x>|D<x>|LINE|EXT}
- TRIGger:A:PULSEWidth:SOUrce?
Info
  • CH<x> specifies an analog input channel as the A edge trigger source. x has a minimum of 1 and a maximum of 4.
  • D<x> specifies an digital input channel as the A edge trigger source. x has a minimum of 0 and a maximum of 15.
  • EXT specifies an external trigger using the Aux In connector located on the front panel of the oscilloscope.
  • LINE specifies AC line voltage.

TriggerAPulsewidthWhen

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:PULSEWidth:WHEn command.

Description
  • Sets or returns whether to trigger on a pulse that meets, falls outside, or within the specified range of limits.
Usage
  • Using the .query() method will send the TRIGger:A:PULSEWidth:WHEn? query.
  • Using the .verify(value) method will send the TRIGger:A:PULSEWidth:WHEn? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:PULSEWidth:WHEn value command.
SCPI Syntax
- TRIGger:A:PULSEWidth:WHEn {LESSthan|MOREthan|EQual|UNEQual}
- TRIGger:A:PULSEWidth:WHEn?
Info
  • LESSthan argument sets the oscilloscope to trigger if a pulse is detected with width less than the time set by the TRIGGER:A:PULSEWIDTH:WIDTH command.
  • MOREthan argument sets the oscilloscope to trigger if a pulse is detected with width more than the time set by the TRIGGER:A:PULSEWIDTH:WIDTH command.
  • EQUal argument sets the oscilloscope to trigger if a pulse is detected with width equal to the time period specified in TRIGGER:A:PULSEWIDTH:WIDTH within a ±5% tolerance.
  • UNEQual argument sets the oscilloscope to trigger if a pulse is detected with width greater than or less than (but not equal) the time period specified in TRIGGER:A:PULSEWIDTH:WIDTH within a ±5% tolerance.

TriggerAPulsewidthWidth

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:PULSEWidth:Width command.

Description
  • Sets or returns the width setting for the pulse width trigger.
Usage
  • Using the .query() method will send the TRIGger:A:PULSEWidth:Width? query.
  • Using the .verify(value) method will send the TRIGger:A:PULSEWidth:Width? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:PULSEWidth:Width value command.
SCPI Syntax
- TRIGger:A:PULSEWidth:Width <NR3>
- TRIGger:A:PULSEWidth:Width?
Info
  • <NR3> specifies the pulse width in seconds.

TriggerARisefall

Bases: SCPICmdRead

The TRIGger:A:RISEFall command.

Description
  • Returns transition time trigger parameters.
Usage
  • Using the .query() method will send the TRIGger:A:RISEFall? query.
  • Using the .verify(value) method will send the TRIGger:A:RISEFall? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:RISEFall?
Properties
  • .deltatime: The TRIGger:A:RISEFall:DELTatime command.
  • .polarity: The TRIGger:A:RISEFall:POLarity command.
  • .source: The TRIGger:A:RISEFall:SOUrce command.
  • .when: The TRIGger:A:RISEFall:WHEn command.

deltatime property

Return the TRIGger:A:RISEFall:DELTatime command.

Description
  • This command specifies the delta time used in calculating the transition value for the transition trigger.
Usage
  • Using the .query() method will send the TRIGger:A:RISEFall:DELTatime? query.
  • Using the .verify(value) method will send the TRIGger:A:RISEFall:DELTatime? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RISEFall:DELTatime value command.
SCPI Syntax
- TRIGger:A:RISEFall:DELTatime <NR3>
- TRIGger:A:RISEFall:DELTatime?
Info
  • <NR3> is a floating point number that specifies the delta time, in seconds.

polarity property

Return the TRIGger:A:RISEFall:POLarity command.

Description
  • This command specifies the polarity for the transition trigger.
Usage
  • Using the .query() method will send the TRIGger:A:RISEFall:POLarity? query.
  • Using the .verify(value) method will send the TRIGger:A:RISEFall:POLarity? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RISEFall:POLarity value command.
SCPI Syntax
- TRIGger:A:RISEFall:POLarity {EITher|NEGative|POSitive}
- TRIGger:A:RISEFall:POLarity?
Info
  • POSitive indicates that a pulse edge must traverse from the lower (most negative) to higher (most positive) level for transition triggering to occur.
  • NEGative indicates that a pulse edge must traverse from the upper (most positive) to lower (most negative) level for transition triggering to occur.
  • EITher indicates either positive or negative polarity.

source property

Return the TRIGger:A:RISEFall:SOUrce command.

Description
  • Sets or returns the source for transition trigger.
Usage
  • Using the .query() method will send the TRIGger:A:RISEFall:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:RISEFall:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RISEFall:SOUrce value command.
SCPI Syntax
- TRIGger:A:RISEFall:SOUrce {CH<x>|D<x>}
- TRIGger:A:RISEFall:SOUrce?
Info
  • CH<x> specifies one of the input channels. x has a minimum of 1 and a maximum of 4.
  • D<x> specifies one of the input digital channels. x has a minimum of 0 and a maximum of 15.

when property

Return the TRIGger:A:RISEFall:WHEn command.

Description
  • This command specifies whether to check for a transitioning signal that is faster or slower than the specified delta time.
Usage
  • Using the .query() method will send the TRIGger:A:RISEFall:WHEn? query.
  • Using the .verify(value) method will send the TRIGger:A:RISEFall:WHEn? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RISEFall:WHEn value command.
SCPI Syntax
- TRIGger:A:RISEFall:WHEn {SLOWer|FASTer|EQual|UNEQual}
- TRIGger:A:RISEFall:WHEn?
Info
  • FASTer sets the trigger to occur when the signal transition time is faster than the time set by TRIGger:A:TRANsition:DELTatime.
  • SLOWer sets the trigger to occur when the signal transition time is slower than the time set by.TRIGger:A:TRANsition:DELTatime.
  • EQual sets the trigger to occur when the signal transition time is equal to the time set by TRIGger:A:TRANsition:DELTatime.
  • UNEQual sets the trigger to occur when the signal transition time is not equal to the time set by TRIGger:A:TRANsition:DELTatime.

TriggerARisefallDeltatime

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:RISEFall:DELTatime command.

Description
  • This command specifies the delta time used in calculating the transition value for the transition trigger.
Usage
  • Using the .query() method will send the TRIGger:A:RISEFall:DELTatime? query.
  • Using the .verify(value) method will send the TRIGger:A:RISEFall:DELTatime? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RISEFall:DELTatime value command.
SCPI Syntax
- TRIGger:A:RISEFall:DELTatime <NR3>
- TRIGger:A:RISEFall:DELTatime?
Info
  • <NR3> is a floating point number that specifies the delta time, in seconds.

TriggerARisefallPolarity

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:RISEFall:POLarity command.

Description
  • This command specifies the polarity for the transition trigger.
Usage
  • Using the .query() method will send the TRIGger:A:RISEFall:POLarity? query.
  • Using the .verify(value) method will send the TRIGger:A:RISEFall:POLarity? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RISEFall:POLarity value command.
SCPI Syntax
- TRIGger:A:RISEFall:POLarity {EITher|NEGative|POSitive}
- TRIGger:A:RISEFall:POLarity?
Info
  • POSitive indicates that a pulse edge must traverse from the lower (most negative) to higher (most positive) level for transition triggering to occur.
  • NEGative indicates that a pulse edge must traverse from the upper (most positive) to lower (most negative) level for transition triggering to occur.
  • EITher indicates either positive or negative polarity.

TriggerARisefallSource

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:RISEFall:SOUrce command.

Description
  • Sets or returns the source for transition trigger.
Usage
  • Using the .query() method will send the TRIGger:A:RISEFall:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:RISEFall:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RISEFall:SOUrce value command.
SCPI Syntax
- TRIGger:A:RISEFall:SOUrce {CH<x>|D<x>}
- TRIGger:A:RISEFall:SOUrce?
Info
  • CH<x> specifies one of the input channels. x has a minimum of 1 and a maximum of 4.
  • D<x> specifies one of the input digital channels. x has a minimum of 0 and a maximum of 15.

TriggerARisefallWhen

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:RISEFall:WHEn command.

Description
  • This command specifies whether to check for a transitioning signal that is faster or slower than the specified delta time.
Usage
  • Using the .query() method will send the TRIGger:A:RISEFall:WHEn? query.
  • Using the .verify(value) method will send the TRIGger:A:RISEFall:WHEn? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RISEFall:WHEn value command.
SCPI Syntax
- TRIGger:A:RISEFall:WHEn {SLOWer|FASTer|EQual|UNEQual}
- TRIGger:A:RISEFall:WHEn?
Info
  • FASTer sets the trigger to occur when the signal transition time is faster than the time set by TRIGger:A:TRANsition:DELTatime.
  • SLOWer sets the trigger to occur when the signal transition time is slower than the time set by.TRIGger:A:TRANsition:DELTatime.
  • EQual sets the trigger to occur when the signal transition time is equal to the time set by TRIGger:A:TRANsition:DELTatime.
  • UNEQual sets the trigger to occur when the signal transition time is not equal to the time set by TRIGger:A:TRANsition:DELTatime.

TriggerARunt

Bases: SCPICmdRead

The TRIGger:A:RUNT command.

Description
  • Returns the current A runt trigger parameters.
Usage
  • Using the .query() method will send the TRIGger:A:RUNT? query.
  • Using the .verify(value) method will send the TRIGger:A:RUNT? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:RUNT?
Properties
  • .polarity: The TRIGger:A:RUNT:POLarity command.
  • .source: The TRIGger:A:RUNT:SOUrce command.
  • .when: The TRIGger:A:RUNT:WHEn command.
  • .width: The TRIGger:A:RUNT:WIDth command.

polarity property

Return the TRIGger:A:RUNT:POLarity command.

Description
  • This command specifies the polarity for the runt trigger.
Usage
  • Using the .query() method will send the TRIGger:A:RUNT:POLarity? query.
  • Using the .verify(value) method will send the TRIGger:A:RUNT:POLarity? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RUNT:POLarity value command.
SCPI Syntax
- TRIGger:A:RUNT:POLarity {EITher|NEGative|POSitive}
- TRIGger:A:RUNT:POLarity?
Info
  • POSitive indicates that the rising edge crosses the low threshold and the falling edge recrosses the low threshold without either edge ever crossing the high threshold.
  • NEGative indicates that the falling edge crosses the high threshold and the rising edge recrosses the high threshold without either edge ever crossing the low threshold.
  • EITher triggers on a runt of either polarity.

source property

Return the TRIGger:A:RUNT:SOUrce command.

Description
  • This command specifies the source waveform for the runt trigger.
Usage
  • Using the .query() method will send the TRIGger:A:RUNT:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:RUNT:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RUNT:SOUrce value command.
SCPI Syntax
- TRIGger:A:RUNT:SOUrce {CH<x>}
- TRIGger:A:RUNT:SOUrce?
Info
  • CH<x> specifies the analog channel number to use as the source waveform for the runt trigger. To specify the threshold levels when using CH as the source, use TRIGGER:A:LOWERTHRESHOLD:CHX and TRIGGER:A:UPPERTHRESHOLD:CHX.

when property

Return the TRIGger:A:RUNT:WHEn command.

Description
  • This command specifies the type of pulse width the trigger checks for when it detects a runt.
Usage
  • Using the .query() method will send the TRIGger:A:RUNT:WHEn? query.
  • Using the .verify(value) method will send the TRIGger:A:RUNT:WHEn? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RUNT:WHEn value command.
SCPI Syntax
- TRIGger:A:RUNT:WHEn {LESSthan|MOREthan|EQual|UNEQual|OCCURS}
- TRIGger:A:RUNT:WHEn?
Info
  • OCCURS sets the instrument to trigger if a runt signal of any detectable width occurs.
  • LESSthan sets the instrument to trigger if the a runt pulse is detected with width less than the time set by the TRIGGER:A:RUNT:WIDTH command.
  • MOREthan sets the instrument to trigger if the a runt pulse is detected with width greater than the time set by the TRIGGER:A:RUNT:WIDTH command.
  • EQual sets the instrument to trigger if a runt pulse is detected with width equal to the time period specified in TRIGGER:A:RUNT:WIDTH within a ±5% tolerance.
  • UNEQual sets the instrument to trigger if a runt pulse is detected with width greater than or less than (but not equal to) the time period specified in TRIGGER:A:RUNT:WIDTH within a ±5% tolerance.

width property

Return the TRIGger:A:RUNT:WIDth command.

Description
  • This command specifies the width, in seconds, for a runt trigger.
Usage
  • Using the .query() method will send the TRIGger:A:RUNT:WIDth? query.
  • Using the .verify(value) method will send the TRIGger:A:RUNT:WIDth? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RUNT:WIDth value command.
SCPI Syntax
- TRIGger:A:RUNT:WIDth <NR3>
- TRIGger:A:RUNT:WIDth?
Info
  • <NR3> is a floating point number that specifies the minimum width, in seconds.

TriggerARuntPolarity

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:RUNT:POLarity command.

Description
  • This command specifies the polarity for the runt trigger.
Usage
  • Using the .query() method will send the TRIGger:A:RUNT:POLarity? query.
  • Using the .verify(value) method will send the TRIGger:A:RUNT:POLarity? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RUNT:POLarity value command.
SCPI Syntax
- TRIGger:A:RUNT:POLarity {EITher|NEGative|POSitive}
- TRIGger:A:RUNT:POLarity?
Info
  • POSitive indicates that the rising edge crosses the low threshold and the falling edge recrosses the low threshold without either edge ever crossing the high threshold.
  • NEGative indicates that the falling edge crosses the high threshold and the rising edge recrosses the high threshold without either edge ever crossing the low threshold.
  • EITher triggers on a runt of either polarity.

TriggerARuntSource

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:RUNT:SOUrce command.

Description
  • This command specifies the source waveform for the runt trigger.
Usage
  • Using the .query() method will send the TRIGger:A:RUNT:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:RUNT:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RUNT:SOUrce value command.
SCPI Syntax
- TRIGger:A:RUNT:SOUrce {CH<x>}
- TRIGger:A:RUNT:SOUrce?
Info
  • CH<x> specifies the analog channel number to use as the source waveform for the runt trigger. To specify the threshold levels when using CH as the source, use TRIGGER:A:LOWERTHRESHOLD:CHX and TRIGGER:A:UPPERTHRESHOLD:CHX.

TriggerARuntWhen

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:RUNT:WHEn command.

Description
  • This command specifies the type of pulse width the trigger checks for when it detects a runt.
Usage
  • Using the .query() method will send the TRIGger:A:RUNT:WHEn? query.
  • Using the .verify(value) method will send the TRIGger:A:RUNT:WHEn? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RUNT:WHEn value command.
SCPI Syntax
- TRIGger:A:RUNT:WHEn {LESSthan|MOREthan|EQual|UNEQual|OCCURS}
- TRIGger:A:RUNT:WHEn?
Info
  • OCCURS sets the instrument to trigger if a runt signal of any detectable width occurs.
  • LESSthan sets the instrument to trigger if the a runt pulse is detected with width less than the time set by the TRIGGER:A:RUNT:WIDTH command.
  • MOREthan sets the instrument to trigger if the a runt pulse is detected with width greater than the time set by the TRIGGER:A:RUNT:WIDTH command.
  • EQual sets the instrument to trigger if a runt pulse is detected with width equal to the time period specified in TRIGGER:A:RUNT:WIDTH within a ±5% tolerance.
  • UNEQual sets the instrument to trigger if a runt pulse is detected with width greater than or less than (but not equal to) the time period specified in TRIGGER:A:RUNT:WIDTH within a ±5% tolerance.

TriggerARuntWidth

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:RUNT:WIDth command.

Description
  • This command specifies the width, in seconds, for a runt trigger.
Usage
  • Using the .query() method will send the TRIGger:A:RUNT:WIDth? query.
  • Using the .verify(value) method will send the TRIGger:A:RUNT:WIDth? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RUNT:WIDth value command.
SCPI Syntax
- TRIGger:A:RUNT:WIDth <NR3>
- TRIGger:A:RUNT:WIDth?
Info
  • <NR3> is a floating point number that specifies the minimum width, in seconds.

TriggerASethold

Bases: SCPICmdRead

The TRIGger:A:SETHold command.

Description
  • Returns the clock edge polarity, voltage threshold and source input; data voltage threshold and source; and both setup and hold times for setup and hold violation triggering.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:SETHold?
Properties
  • .clock: The TRIGger:A:SETHold:CLOCk command.
  • .data: The TRIGger:A:SETHold:DATa command.
  • .holdtime: The TRIGger:A:SETHold:HOLDTime command.
  • .settime: The TRIGger:A:SETHold:SETTime command.
  • .threshold: The TRIGger:A:SETHold:THReshold command tree.

clock property

Return the TRIGger:A:SETHold:CLOCk command.

Description
  • Returns the clock edge polarity, voltage threshold, and source input for setup and hold triggering.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:CLOCk? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:CLOCk? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:SETHold:CLOCk?
Sub-properties
  • .edge: The TRIGger:A:SETHold:CLOCk:EDGE command.
  • .source: The TRIGger:A:SETHold:CLOCk:SOUrce command.
  • .threshold: The TRIGger:A:SETHold:CLOCk:THReshold command.

data property

Return the TRIGger:A:SETHold:DATa command.

Description
  • Returns the voltage threshold and data source for the setup and hold trigger.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:DATa? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:SETHold:DATa?
Sub-properties
  • .source: The TRIGger:A:SETHold:DATa:SOUrce command.
  • .threshold: The TRIGger:A:SETHold:DATa:THReshold command.

holdtime property

Return the TRIGger:A:SETHold:HOLDTime command.

Description
  • This command specifies the hold time for setup and hold violation triggering. This command is equivalent to selecting Setup/Hold Setup from the Trig menu and then setting the desired Hold Time.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:HOLDTime? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:HOLDTime? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:HOLDTime value command.
SCPI Syntax
- TRIGger:A:SETHold:HOLDTime <NR3>
- TRIGger:A:SETHold:HOLDTime?
Info
  • <NR3> is a floating point number that specifies the hold time setting, in seconds. Positive values for hold time occur after the clock edge. Negative values occur before the clock edge.

settime property

Return the TRIGger:A:SETHold:SETTime command.

Description
  • This command specifies the setup time for setup and hold violation triggering. This command is equivalent to selecting Setup/Hold Setup from the Trig menu and then setting the desired Setup Time.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:SETTime? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:SETTime? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:SETTime value command.
SCPI Syntax
- TRIGger:A:SETHold:SETTime <NR3>
- TRIGger:A:SETHold:SETTime?
Info
  • <NR3> is a floating point number that specifies the setup time for setup and hold violation triggering.

threshold property

Return the TRIGger:A:SETHold:THReshold command tree.

Usage
  • Using the .query() method will send the TRIGger:A:SETHold:THReshold? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:THReshold? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .ch: The TRIGger:A:SETHold:THReshold:CH<x> command.
  • .d: The TRIGger:A:SETHold:THReshold:D<x> command.

TriggerASetholdClock

Bases: SCPICmdRead

The TRIGger:A:SETHold:CLOCk command.

Description
  • Returns the clock edge polarity, voltage threshold, and source input for setup and hold triggering.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:CLOCk? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:CLOCk? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:SETHold:CLOCk?
Properties
  • .edge: The TRIGger:A:SETHold:CLOCk:EDGE command.
  • .source: The TRIGger:A:SETHold:CLOCk:SOUrce command.
  • .threshold: The TRIGger:A:SETHold:CLOCk:THReshold command.

edge property

Return the TRIGger:A:SETHold:CLOCk:EDGE command.

Description
  • This command specifies the clock edge polarity for setup and hold triggering.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:CLOCk:EDGE? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:CLOCk:EDGE? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:CLOCk:EDGE value command.
SCPI Syntax
- TRIGger:A:SETHold:CLOCk:EDGE {FALL|RISe}
- TRIGger:A:SETHold:CLOCk:EDGE?
Info
  • FALL specifies polarity as the clock falling edge.
  • RISe specifies polarity as the clock rising edge.

source property

Return the TRIGger:A:SETHold:CLOCk:SOUrce command.

Description
  • Sets or returns the clock source for the setup and hold triggering.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:CLOCk:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:CLOCk:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:CLOCk:SOUrce value command.
SCPI Syntax
- TRIGger:A:SETHold:CLOCk:SOUrce {CH<x>|D<x>}
- TRIGger:A:SETHold:CLOCk:SOUrce?
Info
  • CH<x> specifies the input channel number. x has a minimum of 1 and a maximum of 4.
  • D<x> specifies the input digital channel number. x has a minimum of 0 and a maximum of 15.

threshold property

Return the TRIGger:A:SETHold:CLOCk:THReshold command.

Description
  • Sets or returns the clock voltage threshold for the setup and hold trigger.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:CLOCk:THReshold? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:CLOCk:THReshold? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:CLOCk:THReshold value command.
SCPI Syntax
- TRIGger:A:SETHold:CLOCk:THReshold {<NR3>|TTL|ECL}
- TRIGger:A:SETHold:CLOCk:THReshold?
Info
  • TTL specifies a preset TTL high level of 1.4 V.
  • ECL specifies a preset ECL high level of -1.3 V.
  • <NR3> is the clock level, in volts.

TriggerASetholdClockEdge

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:SETHold:CLOCk:EDGE command.

Description
  • This command specifies the clock edge polarity for setup and hold triggering.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:CLOCk:EDGE? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:CLOCk:EDGE? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:CLOCk:EDGE value command.
SCPI Syntax
- TRIGger:A:SETHold:CLOCk:EDGE {FALL|RISe}
- TRIGger:A:SETHold:CLOCk:EDGE?
Info
  • FALL specifies polarity as the clock falling edge.
  • RISe specifies polarity as the clock rising edge.

TriggerASetholdClockSource

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:SETHold:CLOCk:SOUrce command.

Description
  • Sets or returns the clock source for the setup and hold triggering.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:CLOCk:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:CLOCk:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:CLOCk:SOUrce value command.
SCPI Syntax
- TRIGger:A:SETHold:CLOCk:SOUrce {CH<x>|D<x>}
- TRIGger:A:SETHold:CLOCk:SOUrce?
Info
  • CH<x> specifies the input channel number. x has a minimum of 1 and a maximum of 4.
  • D<x> specifies the input digital channel number. x has a minimum of 0 and a maximum of 15.

TriggerASetholdClockThreshold

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:SETHold:CLOCk:THReshold command.

Description
  • Sets or returns the clock voltage threshold for the setup and hold trigger.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:CLOCk:THReshold? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:CLOCk:THReshold? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:CLOCk:THReshold value command.
SCPI Syntax
- TRIGger:A:SETHold:CLOCk:THReshold {<NR3>|TTL|ECL}
- TRIGger:A:SETHold:CLOCk:THReshold?
Info
  • TTL specifies a preset TTL high level of 1.4 V.
  • ECL specifies a preset ECL high level of -1.3 V.
  • <NR3> is the clock level, in volts.

TriggerASetholdData

Bases: SCPICmdRead

The TRIGger:A:SETHold:DATa command.

Description
  • Returns the voltage threshold and data source for the setup and hold trigger.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:DATa? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:SETHold:DATa?
Properties
  • .source: The TRIGger:A:SETHold:DATa:SOUrce command.
  • .threshold: The TRIGger:A:SETHold:DATa:THReshold command.

source property

Return the TRIGger:A:SETHold:DATa:SOUrce command.

Description
  • Sets or returns the data source for the setup and hold trigger. You cannot specify the same source for both clock and data. For DPO models, you can specify only a single data source. Data sources for DPO models may be one of CH1-CH4 or D0-D15.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:DATa:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:DATa:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:DATa:SOUrce value command.
SCPI Syntax
- TRIGger:A:SETHold:DATa:SOUrce DPO Models:{CH<x>|D<x>}
- TRIGger:A:SETHold:DATa:SOUrce?
Info
  • <wfm> specifies the source channel number and is one of CH1-CH4, and D0-D15. You can specify only one waveform on a DPO.

threshold property

Return the TRIGger:A:SETHold:DATa:THReshold command.

Description
  • Sets or returns the data voltage threshold for setup and hold trigger. The digital channels do not have independent trigger levels. Channels D0-D7 share one common trigger level and D8-D15 share another common trigger level. For example changing the trigger level for D3 changes the levels for D0-D7.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:DATa:THReshold? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:DATa:THReshold? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:DATa:THReshold value command.
SCPI Syntax
- TRIGger:A:SETHold:DATa:THReshold {<NR3>|TTL|ECL}
- TRIGger:A:SETHold:DATa:THReshold?
Info
  • TTL specifies the preset TTL high level of 1.4 V.
  • ECL specifies the preset ECL high level of -1.3 V.
  • <NR3> is the setup and hold data level, in V.

TriggerASetholdDataSource

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:SETHold:DATa:SOUrce command.

Description
  • Sets or returns the data source for the setup and hold trigger. You cannot specify the same source for both clock and data. For DPO models, you can specify only a single data source. Data sources for DPO models may be one of CH1-CH4 or D0-D15.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:DATa:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:DATa:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:DATa:SOUrce value command.
SCPI Syntax
- TRIGger:A:SETHold:DATa:SOUrce DPO Models:{CH<x>|D<x>}
- TRIGger:A:SETHold:DATa:SOUrce?
Info
  • <wfm> specifies the source channel number and is one of CH1-CH4, and D0-D15. You can specify only one waveform on a DPO.

TriggerASetholdDataThreshold

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:SETHold:DATa:THReshold command.

Description
  • Sets or returns the data voltage threshold for setup and hold trigger. The digital channels do not have independent trigger levels. Channels D0-D7 share one common trigger level and D8-D15 share another common trigger level. For example changing the trigger level for D3 changes the levels for D0-D7.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:DATa:THReshold? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:DATa:THReshold? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:DATa:THReshold value command.
SCPI Syntax
- TRIGger:A:SETHold:DATa:THReshold {<NR3>|TTL|ECL}
- TRIGger:A:SETHold:DATa:THReshold?
Info
  • TTL specifies the preset TTL high level of 1.4 V.
  • ECL specifies the preset ECL high level of -1.3 V.
  • <NR3> is the setup and hold data level, in V.

TriggerASetholdHoldtime

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:SETHold:HOLDTime command.

Description
  • This command specifies the hold time for setup and hold violation triggering. This command is equivalent to selecting Setup/Hold Setup from the Trig menu and then setting the desired Hold Time.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:HOLDTime? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:HOLDTime? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:HOLDTime value command.
SCPI Syntax
- TRIGger:A:SETHold:HOLDTime <NR3>
- TRIGger:A:SETHold:HOLDTime?
Info
  • <NR3> is a floating point number that specifies the hold time setting, in seconds. Positive values for hold time occur after the clock edge. Negative values occur before the clock edge.

TriggerASetholdSettime

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:SETHold:SETTime command.

Description
  • This command specifies the setup time for setup and hold violation triggering. This command is equivalent to selecting Setup/Hold Setup from the Trig menu and then setting the desired Setup Time.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:SETTime? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:SETTime? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:SETTime value command.
SCPI Syntax
- TRIGger:A:SETHold:SETTime <NR3>
- TRIGger:A:SETHold:SETTime?
Info
  • <NR3> is a floating point number that specifies the setup time for setup and hold violation triggering.

TriggerASetholdThreshold

Bases: SCPICmdRead

The TRIGger:A:SETHold:THReshold command tree.

Usage
  • Using the .query() method will send the TRIGger:A:SETHold:THReshold? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:THReshold? query and raise an AssertionError if the returned value does not match value.
Properties
  • .ch: The TRIGger:A:SETHold:THReshold:CH<x> command.
  • .d: The TRIGger:A:SETHold:THReshold:D<x> command.

ch property

Return the TRIGger:A:SETHold:THReshold:CH<x> command.

Description
  • This command specifies the threshold for the analog channel . x can be 1-4. All trigger types using the channel are affected.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:THReshold:CH<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:THReshold:CH<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:THReshold:CH<x> value command.
SCPI Syntax
- TRIGger:A:SETHold:THReshold:CH<x> {<NR3>|ECL|TTL}
- TRIGger:A:SETHold:THReshold:CH<x>?
Info
  • <NR3> is a floating point number that specifies the threshold voltage, in volts.
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.

d property

Return the TRIGger:A:SETHold:THReshold:D<x> command.

Description
  • This command sets the threshold for the specified digital channel. can be D0 - D15. All trigger types using the digital channel are affected.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:THReshold:D<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:THReshold:D<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:THReshold:D<x> value command.
SCPI Syntax
- TRIGger:A:SETHold:THReshold:D<x> {<NR3>|ECL|TTL}
- TRIGger:A:SETHold:THReshold:D<x>?
Info
  • <NR3> is a floating point number that specifies the threshold voltage, in volts.
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.

TriggerASetholdThresholdChannel

Bases: ValidatedChannel, SCPICmdWrite, SCPICmdRead

The TRIGger:A:SETHold:THReshold:CH<x> command.

Description
  • This command specifies the threshold for the analog channel . x can be 1-4. All trigger types using the channel are affected.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:THReshold:CH<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:THReshold:CH<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:THReshold:CH<x> value command.
SCPI Syntax
- TRIGger:A:SETHold:THReshold:CH<x> {<NR3>|ECL|TTL}
- TRIGger:A:SETHold:THReshold:CH<x>?
Info
  • <NR3> is a floating point number that specifies the threshold voltage, in volts.
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.

TriggerASetholdThresholdDigitalBit

Bases: ValidatedDigitalBit, SCPICmdWrite, SCPICmdRead

The TRIGger:A:SETHold:THReshold:D<x> command.

Description
  • This command sets the threshold for the specified digital channel. can be D0 - D15. All trigger types using the digital channel are affected.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:THReshold:D<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:THReshold:D<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:THReshold:D<x> value command.
SCPI Syntax
- TRIGger:A:SETHold:THReshold:D<x> {<NR3>|ECL|TTL}
- TRIGger:A:SETHold:THReshold:D<x>?
Info
  • <NR3> is a floating point number that specifies the threshold voltage, in volts.
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.

TriggerATransition

Bases: SCPICmdRead

The TRIGger:A:TRANsition command.

Description
  • Returns transition time trigger parameters.
Usage
  • Using the .query() method will send the TRIGger:A:TRANsition? query.
  • Using the .verify(value) method will send the TRIGger:A:TRANsition? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:TRANsition?
Properties
  • .deltatime: The TRIGger:A:TRANsition:DELTatime command.
  • .polarity: The TRIGger:A:TRANsition:POLarity command.
  • .source: The TRIGger:A:TRANsition:SOUrce command.
  • .when: The TRIGger:A:TRANsition:WHEn command.

deltatime property

Return the TRIGger:A:TRANsition:DELTatime command.

Description
  • This command specifies the delta time used in calculating the transition value for the transition trigger.
Usage
  • Using the .query() method will send the TRIGger:A:TRANsition:DELTatime? query.
  • Using the .verify(value) method will send the TRIGger:A:TRANsition:DELTatime? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:TRANsition:DELTatime value command.
SCPI Syntax
- TRIGger:A:TRANsition:DELTatime <NR3>
- TRIGger:A:TRANsition:DELTatime?
Info
  • <NR3> is a floating point number that specifies the delta time, in seconds.

polarity property

Return the TRIGger:A:TRANsition:POLarity command.

Description
  • This command specifies the polarity for the transition trigger.
Usage
  • Using the .query() method will send the TRIGger:A:TRANsition:POLarity? query.
  • Using the .verify(value) method will send the TRIGger:A:TRANsition:POLarity? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:TRANsition:POLarity value command.
SCPI Syntax
- TRIGger:A:TRANsition:POLarity {EITher|NEGative|POSitive}
- TRIGger:A:TRANsition:POLarity?
Info
  • POSitive indicates that a pulse edge must traverse from the lower (most negative) to higher (most positive) level for transition triggering to occur.
  • NEGative indicates that a pulse edge must traverse from the upper (most positive) to lower (most negative) level for transition triggering to occur.
  • EITher indicates either positive or negative polarity.

source property

Return the TRIGger:A:TRANsition:SOUrce command.

Description
  • Sets or returns the source for transition trigger.
Usage
  • Using the .query() method will send the TRIGger:A:TRANsition:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:TRANsition:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:TRANsition:SOUrce value command.
SCPI Syntax
- TRIGger:A:TRANsition:SOUrce {CH<x>|D<x>}
- TRIGger:A:TRANsition:SOUrce?
Info
  • CH<x> specifies one of the input channels. x has a minimum of 1 and a maximum of 4.
  • D<x> specifies one of the input digital channels. x has a minimum of 0 and a maximum of 15.

when property

Return the TRIGger:A:TRANsition:WHEn command.

Description
  • This command specifies whether to check for a transitioning signal that is faster or slower than the specified delta time.
Usage
  • Using the .query() method will send the TRIGger:A:TRANsition:WHEn? query.
  • Using the .verify(value) method will send the TRIGger:A:TRANsition:WHEn? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:TRANsition:WHEn value command.
SCPI Syntax
- TRIGger:A:TRANsition:WHEn {SLOWer|FASTer|EQual|UNEQual}
- TRIGger:A:TRANsition:WHEn?
Info
  • FASTer sets the trigger to occur when the signal transition time is faster than the time set by TRIGger:A:TRANsition:DELTatime.
  • SLOWer sets the trigger to occur when the signal transition time is slower than the time set by.TRIGger:A:TRANsition:DELTatime.
  • EQual sets the trigger to occur when the signal transition time is equal to the time set by TRIGger:A:TRANsition:DELTatime.
  • UNEQual sets the trigger to occur when the signal transition time is not equal to the time set by TRIGger:A:TRANsition:DELTatime.

TriggerATransitionDeltatime

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:TRANsition:DELTatime command.

Description
  • This command specifies the delta time used in calculating the transition value for the transition trigger.
Usage
  • Using the .query() method will send the TRIGger:A:TRANsition:DELTatime? query.
  • Using the .verify(value) method will send the TRIGger:A:TRANsition:DELTatime? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:TRANsition:DELTatime value command.
SCPI Syntax
- TRIGger:A:TRANsition:DELTatime <NR3>
- TRIGger:A:TRANsition:DELTatime?
Info
  • <NR3> is a floating point number that specifies the delta time, in seconds.

TriggerATransitionPolarity

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:TRANsition:POLarity command.

Description
  • This command specifies the polarity for the transition trigger.
Usage
  • Using the .query() method will send the TRIGger:A:TRANsition:POLarity? query.
  • Using the .verify(value) method will send the TRIGger:A:TRANsition:POLarity? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:TRANsition:POLarity value command.
SCPI Syntax
- TRIGger:A:TRANsition:POLarity {EITher|NEGative|POSitive}
- TRIGger:A:TRANsition:POLarity?
Info
  • POSitive indicates that a pulse edge must traverse from the lower (most negative) to higher (most positive) level for transition triggering to occur.
  • NEGative indicates that a pulse edge must traverse from the upper (most positive) to lower (most negative) level for transition triggering to occur.
  • EITher indicates either positive or negative polarity.

TriggerATransitionSource

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:TRANsition:SOUrce command.

Description
  • Sets or returns the source for transition trigger.
Usage
  • Using the .query() method will send the TRIGger:A:TRANsition:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:TRANsition:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:TRANsition:SOUrce value command.
SCPI Syntax
- TRIGger:A:TRANsition:SOUrce {CH<x>|D<x>}
- TRIGger:A:TRANsition:SOUrce?
Info
  • CH<x> specifies one of the input channels. x has a minimum of 1 and a maximum of 4.
  • D<x> specifies one of the input digital channels. x has a minimum of 0 and a maximum of 15.

TriggerATransitionWhen

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:TRANsition:WHEn command.

Description
  • This command specifies whether to check for a transitioning signal that is faster or slower than the specified delta time.
Usage
  • Using the .query() method will send the TRIGger:A:TRANsition:WHEn? query.
  • Using the .verify(value) method will send the TRIGger:A:TRANsition:WHEn? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:TRANsition:WHEn value command.
SCPI Syntax
- TRIGger:A:TRANsition:WHEn {SLOWer|FASTer|EQual|UNEQual}
- TRIGger:A:TRANsition:WHEn?
Info
  • FASTer sets the trigger to occur when the signal transition time is faster than the time set by TRIGger:A:TRANsition:DELTatime.
  • SLOWer sets the trigger to occur when the signal transition time is slower than the time set by.TRIGger:A:TRANsition:DELTatime.
  • EQual sets the trigger to occur when the signal transition time is equal to the time set by TRIGger:A:TRANsition:DELTatime.
  • UNEQual sets the trigger to occur when the signal transition time is not equal to the time set by TRIGger:A:TRANsition:DELTatime.

TriggerAType

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:TYPe command.

Description
  • Sets or returns the type of A trigger. The five types of triggers are of Edge, Logic, Pulse, Serial, and Video. Logic and Pulse triggers contain classes. Logic triggers consist of State, Pattern, and SetHold classes; Pulse triggers consist of Runt, Width, and Transition logic classes. Once you have set the trigger type, you may also need to identify the associated trigger class. For details on selecting Logic and Pulse trigger classes, see TRIGGER:A:LOGIC:CLASS and TRIGGER:A:PULSE:CLASS respectively.
Usage
  • Using the .query() method will send the TRIGger:A:TYPe? query.
  • Using the .verify(value) method will send the TRIGger:A:TYPe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:TYPe value command.
SCPI Syntax
- TRIGger:A:TYPe {EDGe|LOGic|PULSe|BUS|VIDeo}
- TRIGger:A:TYPe?
Info
  • EDGe is a normal trigger. A trigger event occurs when a signal passes through a specified voltage level in a specified direction and is controlled by the TRIGGER:A:EDGE commands.
  • LOGic specifies that a trigger occurs when specified conditions are met and is controlled by the TRIGGER:A:LOGIC commands.
  • PULSe specifies that a trigger occurs when a specified pulse is found and is controlled by the TRIGGER:A:PULSE commands.
  • BUS specifies that a trigger occurs when a communications signal is found. Supports CAN, I2C, SPI, and RS232 communications signals.
  • VIDeo specifies that the trigger occurs when a video signal is found.

TriggerAUpperthreshold

Bases: SCPICmdRead

The TRIGger:A:UPPerthreshold command tree.

Usage
  • Using the .query() method will send the TRIGger:A:UPPerthreshold? query.
  • Using the .verify(value) method will send the TRIGger:A:UPPerthreshold? query and raise an AssertionError if the returned value does not match value.
Properties
  • .ch: The TRIGger:A:UPPerthreshold:CH<x> command.

ch property

Return the TRIGger:A:UPPerthreshold:CH<x> command.

Description
  • This command sets the upper threshold for channel , where x is the analog channel number 1-4. Each channel can have an independent level. Used only for runt and transition trigger types.
Usage
  • Using the .query() method will send the TRIGger:A:UPPerthreshold:CH<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:UPPerthreshold:CH<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:UPPerthreshold:CH<x> value command.
SCPI Syntax
- TRIGger:A:UPPerthreshold:CH<x> {<NR3>|ECL|TTL}
- TRIGger:A:UPPerthreshold:CH<x>?
Info
  • <NR3> is a floating point number that specifies the threshold level, in volts.
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.

TriggerAUpperthresholdChannel

Bases: ValidatedChannel, SCPICmdWrite, SCPICmdRead

The TRIGger:A:UPPerthreshold:CH<x> command.

Description
  • This command sets the upper threshold for channel , where x is the analog channel number 1-4. Each channel can have an independent level. Used only for runt and transition trigger types.
Usage
  • Using the .query() method will send the TRIGger:A:UPPerthreshold:CH<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:UPPerthreshold:CH<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:UPPerthreshold:CH<x> value command.
SCPI Syntax
- TRIGger:A:UPPerthreshold:CH<x> {<NR3>|ECL|TTL}
- TRIGger:A:UPPerthreshold:CH<x>?
Info
  • <NR3> is a floating point number that specifies the threshold level, in volts.
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.

TriggerAVideo

Bases: SCPICmdRead

The TRIGger:A:VIDeo command.

Description
  • Returns the A trigger video parameters.
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:VIDeo?
Properties
  • .custom: The TRIGger:A:VIDeo:CUSTom command.
  • .hdtv: The TRIGger:A:VIDeo:HDtv command tree.
  • .holdoff: The TRIGger:A:VIDeo:HOLDoff command tree.
  • .line: The TRIGger:A:VIDeo:LINE command.
  • .polarity: The TRIGger:A:VIDeo:POLarity command.
  • .source: The TRIGger:A:VIDeo:SOUrce command.
  • .standard: The TRIGger:A:VIDeo:STANdard command.
  • .sync: The TRIGger:A:VIDeo:SYNC command.
  • .field: The TRIGger:A:VIDeo:FIELD command.

custom property

Return the TRIGger:A:VIDeo:CUSTom command.

Description
  • This query-only command returns the A trigger custom video parameters.
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:CUSTom? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:CUSTom? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:VIDeo:CUSTom?
Sub-properties
  • .lineperiod: The TRIGger:A:VIDeo:CUSTom:LINEPeriod command.
  • .scan: The TRIGger:A:VIDeo:CUSTom:SCAN command.
  • .syncinterval: The TRIGger:A:VIDeo:CUSTom:SYNCInterval command.
  • .format: The TRIGger:A:VIDeo:CUSTom:FORMat command.
  • .type: The TRIGger:A:VIDeo:CUSTom:TYPE command.

field property

Return the TRIGger:A:VIDeo:FIELD command.

Description
  • This command sets the video field to use for triggering on video signals (odd fields, even fields, all fields, all lines, numeric).
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:FIELD? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:FIELD? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:FIELD value command.
SCPI Syntax
- TRIGger:A:VIDeo:FIELD {ODD|EVEN|ALLFields|ALLLines|NUMERic}
- TRIGger:A:VIDeo:FIELD?
Info
  • ODD argument sets the oscilloscope to trigger on interlaced video odd fields.
  • EVEN argument sets the oscilloscope to trigger on interlaced video even fields.
  • ALLFields argument sets the oscilloscope to trigger on all fields.
  • ALLLines argument sets the oscilloscope to trigger on all video lines.
  • NUMERic argument sets the oscilloscope to trigger on the video signal line specified by the TRIGGER:A:VIDEO:LINE command.

hdtv property

Return the TRIGger:A:VIDeo:HDtv command tree.

Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:HDtv? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:HDtv? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .format: The TRIGger:A:VIDeo:HDtv:FORMat command.

holdoff property

Return the TRIGger:A:VIDeo:HOLDoff command tree.

Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:HOLDoff? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:HOLDoff? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .field: The TRIGger:A:VIDeo:HOLDoff:FIELD command.

line property

Return the TRIGger:A:VIDeo:LINE command.

Description
  • This command lets you set the specific video line number to be used for triggering on a video signal. You must also use the command to specify NUMERic as the video field to use.
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:LINE? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:LINE? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:LINE value command.
SCPI Syntax
- TRIGger:A:VIDeo:LINE <NR1>
- TRIGger:A:VIDeo:LINE?
Info
  • <NR1> argument is an integer that sets the video line number on which the oscilloscope triggers. The following table lists the valid choices, depending on the active video standard.

polarity property

Return the TRIGger:A:VIDeo:POLarity command.

Description
  • Sets or returns the polarity of the A video trigger.
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:POLarity? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:POLarity? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:POLarity value command.
SCPI Syntax
- TRIGger:A:VIDeo:POLarity {NEGative|POSitive|NORMal|INVERTed}
- TRIGger:A:VIDeo:POLarity?
Info
  • POSitive argument sets the oscilloscope to trigger on a positive video sync pulse.
  • NEGative argument sets the oscilloscope to trigger on a negative video sync pulse.

source property

Return the TRIGger:A:VIDeo:SOUrce command.

Description
  • This command sets the source channel to use for triggering on video signals (CH1-4).
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:SOUrce value command.
SCPI Syntax
- TRIGger:A:VIDeo:SOUrce {CH<x>}
- TRIGger:A:VIDeo:SOUrce?
Info
  • CH<x> specifies the input channel to use as the A video trigger. x has a minimum of 1 and a maximum of 4.

standard property

Return the TRIGger:A:VIDeo:STANdard command.

Description
  • Sets or returns the standard for the video trigger.
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:STANdard? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:STANdard? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:STANdard value command.
SCPI Syntax
- TRIGger:A:VIDeo:STANdard {NTSc|PAL|SECAM}
- TRIGger:A:VIDeo:STANdard?
Info
  • NTSc sets the oscilloscope to trigger on video signals that meet the NTSC 525/60/2:1 standard (a line rate of 525 lines per frame and a field rate of 60 Hz).
  • PAL sets the oscilloscope to trigger on video signals that meet the NTSC 625/50/2:1 standard (a line rate of 625 lines per frame and a field rate of 50 Hz).
  • SECAM sets the oscilloscope to trigger on video signals that meet the SECAM standard.

sync property

Return the TRIGger:A:VIDeo:SYNC command.

Description
  • This command sets the video field to use for triggering on video signals (odd fields, even fields, all fields, all lines, numeric).
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:SYNC? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:SYNC? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:SYNC value command.
SCPI Syntax
- TRIGger:A:VIDeo:SYNC {ODD|EVEN|ALLFields|ALLLines|NUMERic}
- TRIGger:A:VIDeo:SYNC?
Info
  • ODD argument sets the oscilloscope to trigger on interlaced video odd fields.
  • EVEN argument sets the oscilloscope to trigger on interlaced video even fields.
  • ALLFields argument sets the oscilloscope to trigger on all fields.
  • ALLLines argument sets the oscilloscope to trigger on all video lines.
  • NUMERic argument sets the oscilloscope to trigger on the video signal line specified by the TRIGGER:A:VIDEO:LINE command.

TriggerAVideoCustom

Bases: SCPICmdRead

The TRIGger:A:VIDeo:CUSTom command.

Description
  • This query-only command returns the A trigger custom video parameters.
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:CUSTom? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:CUSTom? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:A:VIDeo:CUSTom?
Properties
  • .lineperiod: The TRIGger:A:VIDeo:CUSTom:LINEPeriod command.
  • .scan: The TRIGger:A:VIDeo:CUSTom:SCAN command.
  • .syncinterval: The TRIGger:A:VIDeo:CUSTom:SYNCInterval command.
  • .format: The TRIGger:A:VIDeo:CUSTom:FORMat command.
  • .type: The TRIGger:A:VIDeo:CUSTom:TYPE command.

format property

Return the TRIGger:A:VIDeo:CUSTom:FORMat command.

Description
  • Sets or returns the video trigger format. Use this command only when the video format is set to custom.
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:CUSTom:FORMat? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:CUSTom:FORMat? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:CUSTom:FORMat value command.
SCPI Syntax
- TRIGger:A:VIDeo:CUSTom:FORMat {INTERLAced|PROGressive}
- TRIGger:A:VIDeo:CUSTom:FORMat?
Info
  • INTERLAced argument sets the format for interlaced video lines.
  • PROGressive argument sets the format for progressive video lines.

lineperiod property

Return the TRIGger:A:VIDeo:CUSTom:LINEPeriod command.

Description
  • This command sets the line period for the standard under test. To use this command, you must also set the video standard to BILevelcustom or TRILevelcustom (using TRIGGER:A:VIDEO:STANDARD).
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:CUSTom:LINEPeriod? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:CUSTom:LINEPeriod? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:CUSTom:LINEPeriod value command.
SCPI Syntax
- TRIGger:A:VIDeo:CUSTom:LINEPeriod <NR3>
- TRIGger:A:VIDeo:CUSTom:LINEPeriod?
Info
  • <NR3> is the custom video line period.

scan property

Return the TRIGger:A:VIDeo:CUSTom:SCAN command.

Description
  • Sets or returns the horizontal line scan rate of the A video trigger. Use this command only when the video format is set to custom.
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:CUSTom:SCAN? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:CUSTom:SCAN? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:CUSTom:SCAN value command.
SCPI Syntax
- TRIGger:A:VIDeo:CUSTom:SCAN {RATE15K|RATE20K|RATE25K|RATE35K|RATE50K}
- TRIGger:A:VIDeo:CUSTom:SCAN?
Info
  • RATE15 sets the range of the video line scan rate to 15 kHz through 20 kHz. This is the standard broadcast rate.
  • RATE20 sets the range of the video line scan rate to 20 kHz through 25 kHz.
  • RATE25 sets the range of the video line scan rate to 25 kHz through 35 kHz.
  • RATE35 sets the range of the video line scan rate to 35 kHz through 50 kHz.
  • RATE50 sets the range of the video line scan rate to 50 kHz through 65 kHz.

syncinterval property

Return the TRIGger:A:VIDeo:CUSTom:SYNCInterval command.

Description
  • This command sets the sync interval for the standard under test to use for triggering on video signals. This is only required for BiLevel Custom. To use this command, you must also set the video standard to BILevelcustom (using TRIGGER:A:VIDEO:STANDARD).
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:CUSTom:SYNCInterval? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:CUSTom:SYNCInterval? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:CUSTom:SYNCInterval value command.
SCPI Syntax
- TRIGger:A:VIDeo:CUSTom:SYNCInterval <NR3>
- TRIGger:A:VIDeo:CUSTom:SYNCInterval?
Info
  • <NR3> is the sync interval.

type property

Return the TRIGger:A:VIDeo:CUSTom:TYPE command.

Description
  • Sets or returns the video trigger format. Use this command only when the video format is set to custom.
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:CUSTom:TYPE? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:CUSTom:TYPE? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:CUSTom:TYPE value command.
SCPI Syntax
- TRIGger:A:VIDeo:CUSTom:TYPE {INTERLAced|PROGressive}
- TRIGger:A:VIDeo:CUSTom:TYPE?
Info
  • INTERLAced argument sets the format for interlaced video lines.
  • PROGressive argument sets the format for progressive video lines.

TriggerAVideoCustomFormat

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:VIDeo:CUSTom:FORMat command.

Description
  • Sets or returns the video trigger format. Use this command only when the video format is set to custom.
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:CUSTom:FORMat? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:CUSTom:FORMat? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:CUSTom:FORMat value command.
SCPI Syntax
- TRIGger:A:VIDeo:CUSTom:FORMat {INTERLAced|PROGressive}
- TRIGger:A:VIDeo:CUSTom:FORMat?
Info
  • INTERLAced argument sets the format for interlaced video lines.
  • PROGressive argument sets the format for progressive video lines.

TriggerAVideoCustomLineperiod

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:VIDeo:CUSTom:LINEPeriod command.

Description
  • This command sets the line period for the standard under test. To use this command, you must also set the video standard to BILevelcustom or TRILevelcustom (using TRIGGER:A:VIDEO:STANDARD).
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:CUSTom:LINEPeriod? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:CUSTom:LINEPeriod? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:CUSTom:LINEPeriod value command.
SCPI Syntax
- TRIGger:A:VIDeo:CUSTom:LINEPeriod <NR3>
- TRIGger:A:VIDeo:CUSTom:LINEPeriod?
Info
  • <NR3> is the custom video line period.

TriggerAVideoCustomScan

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:VIDeo:CUSTom:SCAN command.

Description
  • Sets or returns the horizontal line scan rate of the A video trigger. Use this command only when the video format is set to custom.
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:CUSTom:SCAN? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:CUSTom:SCAN? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:CUSTom:SCAN value command.
SCPI Syntax
- TRIGger:A:VIDeo:CUSTom:SCAN {RATE15K|RATE20K|RATE25K|RATE35K|RATE50K}
- TRIGger:A:VIDeo:CUSTom:SCAN?
Info
  • RATE15 sets the range of the video line scan rate to 15 kHz through 20 kHz. This is the standard broadcast rate.
  • RATE20 sets the range of the video line scan rate to 20 kHz through 25 kHz.
  • RATE25 sets the range of the video line scan rate to 25 kHz through 35 kHz.
  • RATE35 sets the range of the video line scan rate to 35 kHz through 50 kHz.
  • RATE50 sets the range of the video line scan rate to 50 kHz through 65 kHz.

TriggerAVideoCustomSyncinterval

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:VIDeo:CUSTom:SYNCInterval command.

Description
  • This command sets the sync interval for the standard under test to use for triggering on video signals. This is only required for BiLevel Custom. To use this command, you must also set the video standard to BILevelcustom (using TRIGGER:A:VIDEO:STANDARD).
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:CUSTom:SYNCInterval? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:CUSTom:SYNCInterval? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:CUSTom:SYNCInterval value command.
SCPI Syntax
- TRIGger:A:VIDeo:CUSTom:SYNCInterval <NR3>
- TRIGger:A:VIDeo:CUSTom:SYNCInterval?
Info
  • <NR3> is the sync interval.

TriggerAVideoCustomType

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:VIDeo:CUSTom:TYPE command.

Description
  • Sets or returns the video trigger format. Use this command only when the video format is set to custom.
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:CUSTom:TYPE? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:CUSTom:TYPE? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:CUSTom:TYPE value command.
SCPI Syntax
- TRIGger:A:VIDeo:CUSTom:TYPE {INTERLAced|PROGressive}
- TRIGger:A:VIDeo:CUSTom:TYPE?
Info
  • INTERLAced argument sets the format for interlaced video lines.
  • PROGressive argument sets the format for progressive video lines.

TriggerAVideoField

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:VIDeo:FIELD command.

Description
  • This command sets the video field to use for triggering on video signals (odd fields, even fields, all fields, all lines, numeric).
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:FIELD? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:FIELD? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:FIELD value command.
SCPI Syntax
- TRIGger:A:VIDeo:FIELD {ODD|EVEN|ALLFields|ALLLines|NUMERic}
- TRIGger:A:VIDeo:FIELD?
Info
  • ODD argument sets the oscilloscope to trigger on interlaced video odd fields.
  • EVEN argument sets the oscilloscope to trigger on interlaced video even fields.
  • ALLFields argument sets the oscilloscope to trigger on all fields.
  • ALLLines argument sets the oscilloscope to trigger on all video lines.
  • NUMERic argument sets the oscilloscope to trigger on the video signal line specified by the TRIGGER:A:VIDEO:LINE command.

TriggerAVideoHdtv

Bases: SCPICmdRead

The TRIGger:A:VIDeo:HDtv command tree.

Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:HDtv? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:HDtv? query and raise an AssertionError if the returned value does not match value.
Properties
  • .format: The TRIGger:A:VIDeo:HDtv:FORMat command.

format property

Return the TRIGger:A:VIDeo:HDtv:FORMat command.

Description
  • Sets or returns the HDTV video signal format on which to trigger.
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:HDtv:FORMat? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:HDtv:FORMat? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:HDtv:FORMat value command.
SCPI Syntax
- TRIGger:A:VIDeo:HDtv:FORMat {HD1080P24|HD720P60|HD480P60|HD1080I50|HD1080P25|HD1080I60|HD1080PSF24}
- TRIGger:A:VIDeo:HDtv:FORMat?

TriggerAVideoHdtvFormat

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:VIDeo:HDtv:FORMat command.

Description
  • Sets or returns the HDTV video signal format on which to trigger.
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:HDtv:FORMat? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:HDtv:FORMat? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:HDtv:FORMat value command.
SCPI Syntax
- TRIGger:A:VIDeo:HDtv:FORMat {HD1080P24|HD720P60|HD480P60|HD1080I50|HD1080P25|HD1080I60|HD1080PSF24}
- TRIGger:A:VIDeo:HDtv:FORMat?

TriggerAVideoHoldoff

Bases: SCPICmdRead

The TRIGger:A:VIDeo:HOLDoff command tree.

Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:HOLDoff? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:HOLDoff? query and raise an AssertionError if the returned value does not match value.
Properties
  • .field: The TRIGger:A:VIDeo:HOLDoff:FIELD command.

field property

Return the TRIGger:A:VIDeo:HOLDoff:FIELD command.

Description
  • This command sets the video trigger holdoff, in terms of video fields, to use for triggering on video signals.
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:HOLDoff:FIELD? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:HOLDoff:FIELD? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:HOLDoff:FIELD value command.
SCPI Syntax
- TRIGger:A:VIDeo:HOLDoff:FIELD <NR3>
- TRIGger:A:VIDeo:HOLDoff:FIELD?
Info
  • <NR3> argument is a real number from 0.0 to 8.5 in increments of 0.5. The argument sets the number of fields that the oscilloscope waits before rearming the video trigger.

TriggerAVideoHoldoffField

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:VIDeo:HOLDoff:FIELD command.

Description
  • This command sets the video trigger holdoff, in terms of video fields, to use for triggering on video signals.
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:HOLDoff:FIELD? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:HOLDoff:FIELD? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:HOLDoff:FIELD value command.
SCPI Syntax
- TRIGger:A:VIDeo:HOLDoff:FIELD <NR3>
- TRIGger:A:VIDeo:HOLDoff:FIELD?
Info
  • <NR3> argument is a real number from 0.0 to 8.5 in increments of 0.5. The argument sets the number of fields that the oscilloscope waits before rearming the video trigger.

TriggerAVideoLine

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:VIDeo:LINE command.

Description
  • This command lets you set the specific video line number to be used for triggering on a video signal. You must also use the command to specify NUMERic as the video field to use.
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:LINE? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:LINE? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:LINE value command.
SCPI Syntax
- TRIGger:A:VIDeo:LINE <NR1>
- TRIGger:A:VIDeo:LINE?
Info
  • <NR1> argument is an integer that sets the video line number on which the oscilloscope triggers. The following table lists the valid choices, depending on the active video standard.

TriggerAVideoPolarity

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:VIDeo:POLarity command.

Description
  • Sets or returns the polarity of the A video trigger.
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:POLarity? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:POLarity? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:POLarity value command.
SCPI Syntax
- TRIGger:A:VIDeo:POLarity {NEGative|POSitive|NORMal|INVERTed}
- TRIGger:A:VIDeo:POLarity?
Info
  • POSitive argument sets the oscilloscope to trigger on a positive video sync pulse.
  • NEGative argument sets the oscilloscope to trigger on a negative video sync pulse.

TriggerAVideoSource

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:VIDeo:SOUrce command.

Description
  • This command sets the source channel to use for triggering on video signals (CH1-4).
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:SOUrce value command.
SCPI Syntax
- TRIGger:A:VIDeo:SOUrce {CH<x>}
- TRIGger:A:VIDeo:SOUrce?
Info
  • CH<x> specifies the input channel to use as the A video trigger. x has a minimum of 1 and a maximum of 4.

TriggerAVideoStandard

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:VIDeo:STANdard command.

Description
  • Sets or returns the standard for the video trigger.
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:STANdard? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:STANdard? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:STANdard value command.
SCPI Syntax
- TRIGger:A:VIDeo:STANdard {NTSc|PAL|SECAM}
- TRIGger:A:VIDeo:STANdard?
Info
  • NTSc sets the oscilloscope to trigger on video signals that meet the NTSC 525/60/2:1 standard (a line rate of 525 lines per frame and a field rate of 60 Hz).
  • PAL sets the oscilloscope to trigger on video signals that meet the NTSC 625/50/2:1 standard (a line rate of 625 lines per frame and a field rate of 50 Hz).
  • SECAM sets the oscilloscope to trigger on video signals that meet the SECAM standard.

TriggerAVideoSync

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:VIDeo:SYNC command.

Description
  • This command sets the video field to use for triggering on video signals (odd fields, even fields, all fields, all lines, numeric).
Usage
  • Using the .query() method will send the TRIGger:A:VIDeo:SYNC? query.
  • Using the .verify(value) method will send the TRIGger:A:VIDeo:SYNC? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:VIDeo:SYNC value command.
SCPI Syntax
- TRIGger:A:VIDeo:SYNC {ODD|EVEN|ALLFields|ALLLines|NUMERic}
- TRIGger:A:VIDeo:SYNC?
Info
  • ODD argument sets the oscilloscope to trigger on interlaced video odd fields.
  • EVEN argument sets the oscilloscope to trigger on interlaced video even fields.
  • ALLFields argument sets the oscilloscope to trigger on all fields.
  • ALLLines argument sets the oscilloscope to trigger on all video lines.
  • NUMERic argument sets the oscilloscope to trigger on the video signal line specified by the TRIGGER:A:VIDEO:LINE command.

TriggerB

Bases: SCPICmdRead

The TRIGger:B command tree.

Usage
  • Using the .query() method will send the TRIGger:B? query.
  • Using the .verify(value) method will send the TRIGger:B? query and raise an AssertionError if the returned value does not match value.
Properties
  • .level: The TRIGger:B:LEVel command tree.
  • .lowerthreshold: The TRIGger:B:LOWerthreshold command tree.

level property

Return the TRIGger:B:LEVel command tree.

Usage
  • Using the .query() method will send the TRIGger:B:LEVel? query.
  • Using the .verify(value) method will send the TRIGger:B:LEVel? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .d: The TRIGger:B:LEVel:D<x> command.

lowerthreshold property

lowerthreshold: TriggerBLowerthreshold

Return the TRIGger:B:LOWerthreshold command tree.

Usage
  • Using the .query() method will send the TRIGger:B:LOWerthreshold? query.
  • Using the .verify(value) method will send the TRIGger:B:LOWerthreshold? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .d: The TRIGger:B:LOWerthreshold:D<x> command.

TriggerBLevel

Bases: SCPICmdRead

The TRIGger:B:LEVel command tree.

Usage
  • Using the .query() method will send the TRIGger:B:LEVel? query.
  • Using the .verify(value) method will send the TRIGger:B:LEVel? query and raise an AssertionError if the returned value does not match value.
Properties
  • .d: The TRIGger:B:LEVel:D<x> command.

d property

Return the TRIGger:B:LEVel:D<x> command.

Description
  • This command specifies the B trigger level for digital channel , where x is the channel number. Each channel can have an independent level.
Usage
  • Using the .query() method will send the TRIGger:B:LEVel:D<x>? query.
  • Using the .verify(value) method will send the TRIGger:B:LEVel:D<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:B:LEVel:D<x> value command.
SCPI Syntax
- TRIGger:B:LEVel:D<x> {ECL|TTL|<NR3>}
- TRIGger:B:LEVel:D<x>?
Info
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.
  • <NR3> is a floating point number that specifies the trigger level in user units (usually volts).

TriggerBLevelDigitalBit

Bases: ValidatedDigitalBit, SCPICmdWrite, SCPICmdRead

The TRIGger:B:LEVel:D<x> command.

Description
  • This command specifies the B trigger level for digital channel , where x is the channel number. Each channel can have an independent level.
Usage
  • Using the .query() method will send the TRIGger:B:LEVel:D<x>? query.
  • Using the .verify(value) method will send the TRIGger:B:LEVel:D<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:B:LEVel:D<x> value command.
SCPI Syntax
- TRIGger:B:LEVel:D<x> {ECL|TTL|<NR3>}
- TRIGger:B:LEVel:D<x>?
Info
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.
  • <NR3> is a floating point number that specifies the trigger level in user units (usually volts).

TriggerBLowerthreshold

Bases: SCPICmdRead

The TRIGger:B:LOWerthreshold command tree.

Usage
  • Using the .query() method will send the TRIGger:B:LOWerthreshold? query.
  • Using the .verify(value) method will send the TRIGger:B:LOWerthreshold? query and raise an AssertionError if the returned value does not match value.
Properties
  • .d: The TRIGger:B:LOWerthreshold:D<x> command.

d property

Return the TRIGger:B:LOWerthreshold:D<x> command.

Description
  • Sets or queries the lower threshold for the digital channel selected. Each channel can have an independent level. Used in runt and transition triggers as the lower threshold. Used for all other trigger types as the single level/threshold.
Usage
  • Using the .query() method will send the TRIGger:B:LOWerthreshold:D<x>? query.
  • Using the .verify(value) method will send the TRIGger:B:LOWerthreshold:D<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:B:LOWerthreshold:D<x> value command.
SCPI Syntax
- TRIGger:B:LOWerthreshold:D<x> {<NR3>|ECL|TTL}
- TRIGger:B:LOWerthreshold:D<x>?
Info
  • <NR3> is a floating point number that specifies the threshold in volts.
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.

TriggerBLowerthresholdDigitalBit

Bases: ValidatedDigitalBit, SCPICmdWrite, SCPICmdRead

The TRIGger:B:LOWerthreshold:D<x> command.

Description
  • Sets or queries the lower threshold for the digital channel selected. Each channel can have an independent level. Used in runt and transition triggers as the lower threshold. Used for all other trigger types as the single level/threshold.
Usage
  • Using the .query() method will send the TRIGger:B:LOWerthreshold:D<x>? query.
  • Using the .verify(value) method will send the TRIGger:B:LOWerthreshold:D<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:B:LOWerthreshold:D<x> value command.
SCPI Syntax
- TRIGger:B:LOWerthreshold:D<x> {<NR3>|ECL|TTL}
- TRIGger:B:LOWerthreshold:D<x>?
Info
  • <NR3> is a floating point number that specifies the threshold in volts.
  • ECL specifies a preset ECL high level of -1.3V.
  • TTL specifies a preset TTL high level of 1.4V.

TriggerExternal

Bases: SCPICmdRead

The TRIGger:EXTernal command.

Description
  • Returns all external trigger-related parameters for the probe attached to the Aux Input connector.
Usage
  • Using the .query() method will send the TRIGger:EXTernal? query.
  • Using the .verify(value) method will send the TRIGger:EXTernal? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:EXTernal?
Properties
  • .probe: The TRIGger:EXTernal:PRObe command.
  • .yunits: The TRIGger:EXTernal:YUNIts command.

probe property

Return the TRIGger:EXTernal:PRObe command.

Description
  • This command specifies the attenuation factor value of the probe attached to the Aux Input connector.
Usage
  • Using the .query() method will send the TRIGger:EXTernal:PRObe? query.
  • Using the .verify(value) method will send the TRIGger:EXTernal:PRObe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:EXTernal:PRObe value command.
SCPI Syntax
- TRIGger:EXTernal:PRObe <NR3>
- TRIGger:EXTernal:PRObe?
Info
  • <NR3> is a floating point number that specifies the attenuation factor of the probe.

yunits property

Return the TRIGger:EXTernal:YUNIts command.

Description
  • Returns the vertical (Y) units of the probe attached to the Aux In connector.
Usage
  • Using the .query() method will send the TRIGger:EXTernal:YUNIts? query.
  • Using the .verify(value) method will send the TRIGger:EXTernal:YUNIts? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:EXTernal:YUNIts?

TriggerExternalProbe

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:EXTernal:PRObe command.

Description
  • This command specifies the attenuation factor value of the probe attached to the Aux Input connector.
Usage
  • Using the .query() method will send the TRIGger:EXTernal:PRObe? query.
  • Using the .verify(value) method will send the TRIGger:EXTernal:PRObe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:EXTernal:PRObe value command.
SCPI Syntax
- TRIGger:EXTernal:PRObe <NR3>
- TRIGger:EXTernal:PRObe?
Info
  • <NR3> is a floating point number that specifies the attenuation factor of the probe.

TriggerExternalYunits

Bases: SCPICmdRead

The TRIGger:EXTernal:YUNIts command.

Description
  • Returns the vertical (Y) units of the probe attached to the Aux In connector.
Usage
  • Using the .query() method will send the TRIGger:EXTernal:YUNIts? query.
  • Using the .verify(value) method will send the TRIGger:EXTernal:YUNIts? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:EXTernal:YUNIts?

TriggerFrequency

Bases: SCPICmdRead

The TRIGger:FREQuency command.

Description
  • Returns the trigger frequency in hertz if available. If the trigger frequency is not currently available, the IEEE Not A Number (NaN = 99.10E+36) value is returned. The maximum precision of the returned frequency is 12 digits. Use the DISPLAY:TRIGFREQUENCY command to enable/disable the calculation of the trigger frequency.
Usage
  • Using the .query() method will send the TRIGger:FREQuency? query.
  • Using the .verify(value) method will send the TRIGger:FREQuency? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:FREQuency?

TriggerState

Bases: SCPICmdRead

The TRIGger:STATE command.

Description
  • This query-only command returns the current state of the triggering system.
Usage
  • Using the .query() method will send the TRIGger:STATE? query.
  • Using the .verify(value) method will send the TRIGger:STATE? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:STATE?