trigger

The trigger commands module.

These commands are used in the following models: MSO2

THIS FILE IS AUTO-GENERATED, IT SHOULD NOT BE MANUALLY MODIFIED.

Please report an issue if one is found.

Commands and Queries
- TRIGger FORCe
- TRIGger:A SETLevel
- TRIGger:A:BUS:B<x>:CAN:CONDition {SOF|FRAMEtype|IDentifier|DATa|IDANDDATA|EOF|ERRor|FDBITS}
- TRIGger:A:BUS:B<x>:CAN:CONDition?
- TRIGger:A:BUS:B<x>:CAN:DATa:DIRection {READ|WRITE|NOCARE}
- TRIGger:A:BUS:B<x>:CAN:DATa:DIRection?
- TRIGger:A:BUS:B<x>:CAN:DATa:OFFSet <NR1>
- TRIGger:A:BUS:B<x>:CAN:DATa:OFFSet?
- TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier {LESSthan|MOREthan|EQual|UNEQual|LESSEQual|MOREEQual}
- TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier?
- TRIGger:A:BUS:B<x>:CAN:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:CAN:DATa:SIZe?
- TRIGger:A:BUS:B<x>:CAN:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:CAN:DATa:VALue?
- TRIGger:A:BUS:B<x>:CAN:ERRType {ACKMISS|BITSTUFFing|FORMERRor|ANYERRor}
- TRIGger:A:BUS:B<x>:CAN:ERRType?
- TRIGger:A:BUS:B<x>:CAN:FD:BRSBit {ONE|ZERo|NOCARE}
- TRIGger:A:BUS:B<x>:CAN:FD:BRSBit?
- TRIGger:A:BUS:B<x>:CAN:FD:ESIBit {ONE|ZERo|NOCARE}
- TRIGger:A:BUS:B<x>:CAN:FD:ESIBit?
- TRIGger:A:BUS:B<x>:CAN:FRAMEtype {DATa|REMote|ERRor|OVERLoad}
- TRIGger:A:BUS:B<x>:CAN:FRAMEtype?
- TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe {STandard|EXTended}
- TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe?
- TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue <QString>
- TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue?
- TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe {ADDR7|ADDR10}
- TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe?
- TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue <QString>
- TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue?
- TRIGger:A:BUS:B<x>:I2C:CONDition {STARt|STOP|REPEATstart|ACKMISS|ADDRess|DATa|ADDRANDDATA}
- TRIGger:A:BUS:B<x>:I2C:CONDition?
- TRIGger:A:BUS:B<x>:I2C:DATa:DIRection {READ|WRITE|NOCARE}
- TRIGger:A:BUS:B<x>:I2C:DATa:DIRection?
- TRIGger:A:BUS:B<x>:I2C:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:I2C:DATa:SIZe?
- TRIGger:A:BUS:B<x>:I2C:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:I2C:DATa:VALue?
- TRIGger:A:BUS:B<x>:LIN:CONDition {SYNCfield|IDentifier|DATa|IDANDDATA|WAKEup|SLEEP|ERRor}
- TRIGger:A:BUS:B<x>:LIN:CONDition?
- TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue <QString>
- TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue?
- TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier {LESSthan|MOREthan|EQual|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier?
- TRIGger:A:BUS:B<x>:LIN:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:LIN:DATa:SIZe?
- TRIGger:A:BUS:B<x>:LIN:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:LIN:DATa:VALue?
- TRIGger:A:BUS:B<x>:LIN:ERRTYPE {SYNC|PARity|CHecksum}
- TRIGger:A:BUS:B<x>:LIN:ERRTYPE?
- TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue <QString>
- TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue?
- TRIGger:A:BUS:B<x>:PARallel:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:PARallel:DATa:VALue?
- TRIGger:A:BUS:B<x>:RS232C:CONDition {STARt|EOp|DATa|PARItyerror}
- TRIGger:A:BUS:B<x>:RS232C:CONDition?
- TRIGger:A:BUS:B<x>:RS232C:DATa:SIZe <NR3>
- TRIGger:A:BUS:B<x>:RS232C:DATa:SIZe?
- TRIGger:A:BUS:B<x>:RS232C:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:RS232C:DATa:VALue?
- TRIGger:A:BUS:B<x>:SENT:CONDition {START|FAST|SLOW|ERRor}
- TRIGger:A:BUS:B<x>:SENT:CONDition?
- TRIGger:A:BUS:B<x>:SENT:ERRType CRC
- TRIGger:A:BUS:B<x>:SENT:ERRType:CRC {FAST|SLOW}
- TRIGger:A:BUS:B<x>:SENT:ERRType:CRC?
- TRIGger:A:BUS:B<x>:SENT:ERRType?
- TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:HIVALue <QString>
- TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:HIVALue?
- TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:QUALifier {EQual|UNEQual|LESSthan|MOREthan|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:QUALifier?
- TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:VALue <Qstring>
- TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:VALue?
- TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:HIVALue <QString>
- TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:HIVALue?
- TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:QUALifier {EQual|UNEQual|LESSthan|MOREthan|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:QUALifier?
- TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:VALue <Qstring>
- TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:VALue?
- TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:HIVALue <QString>
- TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:HIVALue?
- TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:QUALifier {EQual|UNEQual|LESSthan|MOREthan|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:QUALifier?
- TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:VALue <Qstring>
- TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:VALue?
- TRIGger:A:BUS:B<x>:SENT:FAST:INVERTNIBble:VALue <Qstring>
- TRIGger:A:BUS:B<x>:SENT:FAST:INVERTNIBble:VALue?
- TRIGger:A:BUS:B<x>:SENT:FAST:STATus:VALue <Qstring>
- TRIGger:A:BUS:B<x>:SENT:FAST:STATus:VALue?
- TRIGger:A:BUS:B<x>:SENT:PAUSE:QUALifier {EQual|UNEQual|LESSthan|MOREthan|LESSEQual|MOREEQual|Inrange|OUTrange}
- TRIGger:A:BUS:B<x>:SENT:PAUSE:QUALifier?
- TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:HIVALue <QString>
- TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:HIVALue?
- TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:QUALifier {EQual|UNEQual|LESSthan|MOREthan|LESSEQual|MOREEQual|INRange|OUTRange}
- TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:QUALifier?
- TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:VALue <Qstring>
- TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:VALue?
- TRIGger:A:BUS:B<x>:SENT:SLOW:IDentifier:VALue <Qstring>
- TRIGger:A:BUS:B<x>:SENT:SLOW:IDentifier:VALue?
- TRIGger:A:BUS:B<x>:SPI:CONDition {SS|STARTofframe|DATa}
- TRIGger:A:BUS:B<x>:SPI:CONDition?
- TRIGger:A:BUS:B<x>:SPI:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:SPI:DATa:SIZe?
- TRIGger:A:BUS:B<x>:SPI:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:SPI:DATa:VALue?
- TRIGger:A:BUS:SOUrce B<x>
- TRIGger:A:BUS:SOUrce?
- TRIGger:A:EDGE:COUPling {DC|HFRej|LFRej|NOISErej}
- TRIGger:A:EDGE:COUPling?
- TRIGger:A:EDGE:SLOpe {RISe|FALL|EITher}
- TRIGger:A:EDGE:SLOpe?
- TRIGger:A:EDGE:SOUrce {CH<x>|DCH<x>_D<x>|INTernal|AUXiliary}
- TRIGger:A:EDGE:SOUrce?
- TRIGger:A:HOLDoff:TIMe <NR3>
- TRIGger:A:HOLDoff:TIMe?
- TRIGger:A:LEVel:CH<x> <NR3>
- TRIGger:A:LEVel:CH<x>?
- TRIGger:A:LOGICPattern:CH<x> {HIGH|LOW|X}
- TRIGger:A:LOGICPattern:CH<x>?
- TRIGger:A:LOGICPattern:DCH<x>_D<x> {HIGH|LOW|X}
- TRIGger:A:LOGICPattern:DCH<x>_D<x>?
- TRIGger:A:LOGIc:DELTatime <NR3>
- TRIGger:A:LOGIc:DELTatime?
- TRIGger:A:LOGIc:FUNCtion {AND|NANd|NOR|OR}
- TRIGger:A:LOGIc:FUNCtion?
- TRIGger:A:LOGIc:INPut:CLOCk:SOUrce {CH<x>|DCH<x>_D<x>}
- TRIGger:A:LOGIc:INPut:CLOCk:SOUrce?
- TRIGger:A:LOGIc:POLarity {POSitive|NEGative|EITher}
- TRIGger:A:LOGIc:POLarity?
- TRIGger:A:LOGIc:USECLockedge {OFF|ON|0|1|<NR1>}
- TRIGger:A:LOGIc:USECLockedge?
- TRIGger:A:LOGIc:WHEn {TRUe|FALSe|MOREThan|LESSThan|EQual|UNEQual}
- TRIGger:A:LOGIc:WHEn?
- TRIGger:A:LOWerthreshold:CH<x> <NR3>
- TRIGger:A:LOWerthreshold:CH<x>?
- TRIGger:A:MODe {AUTO|NORMal}
- TRIGger:A:MODe?
- TRIGger:A:PULSEWidth:HIGHLimit <NR3>
- TRIGger:A:PULSEWidth:HIGHLimit?
- TRIGger:A:PULSEWidth:LOWLimit <NR3>
- TRIGger:A:PULSEWidth:LOWLimit?
- TRIGger:A:PULSEWidth:POLarity {NEGative|POSitive}
- TRIGger:A:PULSEWidth:POLarity?
- TRIGger:A:PULSEWidth:SOUrce {CH<x>|DCH<x>_D<x>}
- TRIGger:A:PULSEWidth:SOUrce?
- TRIGger:A:PULSEWidth:WHEn {LESSthan|MOREthan|EQual|UNEQual|WIThin|OUTside}
- TRIGger:A:PULSEWidth:WHEn?
- TRIGger:A:RUNT:POLarity {EITher|NEGative|POSitive}
- TRIGger:A:RUNT:POLarity?
- TRIGger:A:RUNT:SOUrce {CH<x>}
- TRIGger:A:RUNT:SOUrce?
- TRIGger:A:RUNT:WHEn {LESSthan|MOREthan|EQual|UNEQual|OCCURS}
- TRIGger:A:RUNT:WHEn?
- TRIGger:A:RUNT:WIDth <NR3>
- TRIGger:A:RUNT:WIDth?
- TRIGger:A:SETHOLDLOGICVAL:DCH<x>_D<x> {INCLude|DONTInclude}
- TRIGger:A:SETHOLDLOGICVAL:DCH<x>_D<x>?
- TRIGger:A:SETHold:CLOCk:EDGE {FALL|RISe}
- TRIGger:A:SETHold:CLOCk:EDGE?
- TRIGger:A:SETHold:CLOCk:SOUrce {CH<x>|DCH<x>_D<x>}
- TRIGger:A:SETHold:CLOCk:SOUrce?
- TRIGger:A:SETHold:HOLDTime <NR3>
- TRIGger:A:SETHold:HOLDTime?
- TRIGger:A:SETHold:SETTime <NR3>
- TRIGger:A:SETHold:SETTime?
- TRIGger:A:TIMEOut:POLarity {STAYSHigh|STAYSLow|EITher}
- TRIGger:A:TIMEOut:POLarity?
- TRIGger:A:TIMEOut:SOUrce {CH<x>|DCH<x>_D<x>}
- TRIGger:A:TIMEOut:SOUrce?
- TRIGger:A:TIMEOut:TIMe <NR3>
- TRIGger:A:TIMEOut:TIMe?
- TRIGger:A:TYPe {EDGE|WIDth|RISE|FALL|TIMEOut|RUNt|LOGIc|SETHold|BUS}
- TRIGger:A:TYPe?
- TRIGger:A:UPPerthreshold:CH<x> <NR3>
- TRIGger:A:UPPerthreshold:CH<x>?
- TRIGger:A?
- TRIGger:AUXLevel {<NR3>|ECL|TTL}
- TRIGger:AUXLevel?
- TRIGger:HYSTeresis:USER:STATe {ON|OFF|1|0}
- TRIGger:HYSTeresis:USER:STATe?
- TRIGger:HYSTeresis:USER:VALue <NR1>
- TRIGger:HYSTeresis:USER:VALue?
- TRIGger:STATE?
- TRIGger?

Trigger

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger command.

Description
  • This command forces a trigger event to occur. The query returns the current trigger parameters for the instrument.
Usage
  • Using the .query() method will send the TRIGger? query.
  • Using the .verify(value) method will send the TRIGger? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger value command.
SCPI Syntax
- TRIGger FORCe
- TRIGger?
Info
  • FORCe creates a trigger event. If TRIGger:STATE is set to READy, the acquisition will complete. Otherwise, this command will be ignored. This is equivalent to pressing the Force button on the front panel.
Properties
  • .a: The TRIGger:A command.
  • .auxlevel: The TRIGger:AUXLevel command.
  • .hysteresis: The TRIGger:HYSTeresis command tree.
  • .state: The TRIGger:STATE command.

a property

Return the TRIGger:A command.

Description
  • This command sets the A trigger level automatically to 50% of the range of the minimum and maximum values of the trigger input signal. The query returns current trigger parameters. The trigger level is the voltage threshold through which the trigger source signal must pass to generate a trigger event. This command is equivalent to pushing the LEVEL knob on the front panel.
Usage
  • Using the .query() method will send the TRIGger:A? query.
  • Using the .verify(value) method will send the TRIGger:A? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A value command.
SCPI Syntax
- TRIGger:A SETLevel
- TRIGger:A?
Info
  • SETLevel sets the trigger level to 50% of the range of the minimum and maximum values of the trigger input signal.
Sub-properties
  • .bus: The TRIGger:A:BUS command tree.
  • .edge: The TRIGger:A:EDGE command tree.
  • .holdoff: The TRIGger:A:HOLDoff command tree.
  • .level: The TRIGger:A:LEVel command tree.
  • .logicpattern: The TRIGger:A:LOGICPattern command tree.
  • .logic: The TRIGger:A:LOGIc command tree.
  • .lowerthreshold: The TRIGger:A:LOWerthreshold command tree.
  • .mode: The TRIGger:A:MODe command.
  • .pulsewidth: The TRIGger:A:PULSEWidth command tree.
  • .runt: The TRIGger:A:RUNT command tree.
  • .setholdlogicval: The TRIGger:A:SETHOLDLOGICVAL command tree.
  • .sethold: The TRIGger:A:SETHold command tree.
  • .timeout: The TRIGger:A:TIMEOut command tree.
  • .type: The TRIGger:A:TYPe command.
  • .upperthreshold: The TRIGger:A:UPPerthreshold command tree.

auxlevel property

auxlevel: TriggerAuxlevel

Return the TRIGger:AUXLevel command.

Description
  • This command sets or queries the Auxiliary Input voltage level to use for an edge trigger.
Usage
  • Using the .query() method will send the TRIGger:AUXLevel? query.
  • Using the .verify(value) method will send the TRIGger:AUXLevel? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:AUXLevel value command.
SCPI Syntax
- TRIGger:AUXLevel {<NR3>|ECL|TTL}
- TRIGger:AUXLevel?
Info
  • <NR3> is trigger level in Volts.
  • ECL sets trigger level to -1.3 Volts.
  • TTL sets trigger level to 1.4 Volts.

hysteresis property

hysteresis: TriggerHysteresis

Return the TRIGger:HYSTeresis command tree.

Usage
  • Using the .query() method will send the TRIGger:HYSTeresis? query.
  • Using the .verify(value) method will send the TRIGger:HYSTeresis? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .user: The TRIGger:HYSTeresis:USER command tree.

state property

state: TriggerState

Return the TRIGger:STATE command.

Description
  • This query-only command returns the current state of the triggering system.
Usage
  • Using the .query() method will send the TRIGger:STATE? query.
  • Using the .verify(value) method will send the TRIGger:STATE? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:STATE?

TriggerA

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A command.

Description
  • This command sets the A trigger level automatically to 50% of the range of the minimum and maximum values of the trigger input signal. The query returns current trigger parameters. The trigger level is the voltage threshold through which the trigger source signal must pass to generate a trigger event. This command is equivalent to pushing the LEVEL knob on the front panel.
Usage
  • Using the .query() method will send the TRIGger:A? query.
  • Using the .verify(value) method will send the TRIGger:A? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A value command.
SCPI Syntax
- TRIGger:A SETLevel
- TRIGger:A?
Info
  • SETLevel sets the trigger level to 50% of the range of the minimum and maximum values of the trigger input signal.
Properties
  • .bus: The TRIGger:A:BUS command tree.
  • .edge: The TRIGger:A:EDGE command tree.
  • .holdoff: The TRIGger:A:HOLDoff command tree.
  • .level: The TRIGger:A:LEVel command tree.
  • .logicpattern: The TRIGger:A:LOGICPattern command tree.
  • .logic: The TRIGger:A:LOGIc command tree.
  • .lowerthreshold: The TRIGger:A:LOWerthreshold command tree.
  • .mode: The TRIGger:A:MODe command.
  • .pulsewidth: The TRIGger:A:PULSEWidth command tree.
  • .runt: The TRIGger:A:RUNT command tree.
  • .setholdlogicval: The TRIGger:A:SETHOLDLOGICVAL command tree.
  • .sethold: The TRIGger:A:SETHold command tree.
  • .timeout: The TRIGger:A:TIMEOut command tree.
  • .type: The TRIGger:A:TYPe command.
  • .upperthreshold: The TRIGger:A:UPPerthreshold command tree.

bus property

Return the TRIGger:A:BUS command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .b: The TRIGger:A:BUS:B<x> command tree.
  • .source: The TRIGger:A:BUS:SOUrce command.

edge property

Return the TRIGger:A:EDGE command tree.

Usage
  • Using the .query() method will send the TRIGger:A:EDGE? query.
  • Using the .verify(value) method will send the TRIGger:A:EDGE? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .coupling: The TRIGger:A:EDGE:COUPling command.
  • .slope: The TRIGger:A:EDGE:SLOpe command.
  • .source: The TRIGger:A:EDGE:SOUrce command.

holdoff property

holdoff: TriggerAHoldoff

Return the TRIGger:A:HOLDoff command tree.

Usage
  • Using the .query() method will send the TRIGger:A:HOLDoff? query.
  • Using the .verify(value) method will send the TRIGger:A:HOLDoff? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .time: The TRIGger:A:HOLDoff:TIMe command.

level property

Return the TRIGger:A:LEVel command tree.

Usage
  • Using the .query() method will send the TRIGger:A:LEVel? query.
  • Using the .verify(value) method will send the TRIGger:A:LEVel? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .ch: The TRIGger:A:LEVel:CH<x> command.

logic property

Return the TRIGger:A:LOGIc command tree.

Usage
  • Using the .query() method will send the TRIGger:A:LOGIc? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .deltatime: The TRIGger:A:LOGIc:DELTatime command.
  • .function: The TRIGger:A:LOGIc:FUNCtion command.
  • .input: The TRIGger:A:LOGIc:INPut command tree.
  • .polarity: The TRIGger:A:LOGIc:POLarity command.
  • .useclockedge: The TRIGger:A:LOGIc:USECLockedge command.
  • .when: The TRIGger:A:LOGIc:WHEn command.

logicpattern property

logicpattern: TriggerALogicpattern

Return the TRIGger:A:LOGICPattern command tree.

Usage
  • Using the .query() method will send the TRIGger:A:LOGICPattern? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGICPattern? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .ch: The TRIGger:A:LOGICPattern:CH<x> command.
  • .dch: The TRIGger:A:LOGICPattern:DCH<x> command tree.

lowerthreshold property

lowerthreshold: TriggerALowerthreshold

Return the TRIGger:A:LOWerthreshold command tree.

Usage
  • Using the .query() method will send the TRIGger:A:LOWerthreshold? query.
  • Using the .verify(value) method will send the TRIGger:A:LOWerthreshold? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .ch: The TRIGger:A:LOWerthreshold:CH<x> command.

mode property

Return the TRIGger:A:MODe command.

Description
  • This command sets or queries the A trigger mode. This command is equivalent to pushing the Mode button on the front panel.
Usage
  • Using the .query() method will send the TRIGger:A:MODe? query.
  • Using the .verify(value) method will send the TRIGger:A:MODe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:MODe value command.
SCPI Syntax
- TRIGger:A:MODe {AUTO|NORMal}
- TRIGger:A:MODe?
Info
  • AUTO generates a trigger if one is not detected within a specified time period.
  • NORMal waits for a valid trigger event.

pulsewidth property

pulsewidth: TriggerAPulsewidth

Return the TRIGger:A:PULSEWidth command tree.

Usage
  • Using the .query() method will send the TRIGger:A:PULSEWidth? query.
  • Using the .verify(value) method will send the TRIGger:A:PULSEWidth? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .highlimit: The TRIGger:A:PULSEWidth:HIGHLimit command.
  • .lowlimit: The TRIGger:A:PULSEWidth:LOWLimit command.
  • .polarity: The TRIGger:A:PULSEWidth:POLarity command.
  • .source: The TRIGger:A:PULSEWidth:SOUrce command.
  • .when: The TRIGger:A:PULSEWidth:WHEn command.

runt property

Return the TRIGger:A:RUNT command tree.

Usage
  • Using the .query() method will send the TRIGger:A:RUNT? query.
  • Using the .verify(value) method will send the TRIGger:A:RUNT? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .polarity: The TRIGger:A:RUNT:POLarity command.
  • .source: The TRIGger:A:RUNT:SOUrce command.
  • .when: The TRIGger:A:RUNT:WHEn command.
  • .width: The TRIGger:A:RUNT:WIDth command.

sethold property

sethold: TriggerASethold

Return the TRIGger:A:SETHold command tree.

Usage
  • Using the .query() method will send the TRIGger:A:SETHold? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .clock: The TRIGger:A:SETHold:CLOCk command tree.
  • .holdtime: The TRIGger:A:SETHold:HOLDTime command.
  • .settime: The TRIGger:A:SETHold:SETTime command.

setholdlogicval property

setholdlogicval: TriggerASetholdlogicval

Return the TRIGger:A:SETHOLDLOGICVAL command tree.

Usage
  • Using the .query() method will send the TRIGger:A:SETHOLDLOGICVAL? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHOLDLOGICVAL? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .dch: The TRIGger:A:SETHOLDLOGICVAL:DCH<x> command tree.

timeout property

timeout: TriggerATimeout

Return the TRIGger:A:TIMEOut command tree.

Usage
  • Using the .query() method will send the TRIGger:A:TIMEOut? query.
  • Using the .verify(value) method will send the TRIGger:A:TIMEOut? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .polarity: The TRIGger:A:TIMEOut:POLarity command.
  • .source: The TRIGger:A:TIMEOut:SOUrce command.
  • .time: The TRIGger:A:TIMEOut:TIMe command.

type property

Return the TRIGger:A:TYPe command.

Description
  • This command sets or queries the type of A trigger.
Usage
  • Using the .query() method will send the TRIGger:A:TYPe? query.
  • Using the .verify(value) method will send the TRIGger:A:TYPe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:TYPe value command.
SCPI Syntax
- TRIGger:A:TYPe {EDGE|WIDth|RISE|FALL|TIMEOut|RUNt|LOGIc|SETHold|BUS}
- TRIGger:A:TYPe?
Info
  • EDGE is a normal trigger. A trigger event occurs when a signal passes through a specified voltage level in a specified direction and is controlled by the TRIGger:A:EDGE commands.
  • WIDth specifies that the trigger occurs when a pulse with a specified width is found.
  • RISE specifies that the trigger occurs when a pulse with a specified rise is found.
  • FALL specifies that the trigger occurs when a pulse with a specified fall is found.
  • TIMEOut specifies that a trigger occurs when a pulse with the specified timeout is found.
  • RUNt specifies that a trigger occurs when a pulse with the specified parameters is found.
  • LOGIc specifies that a trigger occurs when specified conditions are met and is controlled by the TRIGger:A:LOGIc commands.
  • SETHold specifies that a trigger occurs when a signal is found that meets the setup and hold parameters.
  • BUS specifies that a trigger occurs when a signal is found that meets the specified bus setup parameters.

upperthreshold property

upperthreshold: TriggerAUpperthreshold

Return the TRIGger:A:UPPerthreshold command tree.

Usage
  • Using the .query() method will send the TRIGger:A:UPPerthreshold? query.
  • Using the .verify(value) method will send the TRIGger:A:UPPerthreshold? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .ch: The TRIGger:A:UPPerthreshold:CH<x> command.

TriggerABus

Bases: SCPICmdRead

The TRIGger:A:BUS command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS? query and raise an AssertionError if the returned value does not match value.
Properties
  • .b: The TRIGger:A:BUS:B<x> command tree.
  • .source: The TRIGger:A:BUS:SOUrce command.

b property

Return the TRIGger:A:BUS:B<x> command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .can: The TRIGger:A:BUS:B<x>:CAN command tree.
  • .i2c: The TRIGger:A:BUS:B<x>:I2C command tree.
  • .lin: The TRIGger:A:BUS:B<x>:LIN command tree.
  • .parallel: The TRIGger:A:BUS:B<x>:PARallel command tree.
  • .rs232c: The TRIGger:A:BUS:B<x>:RS232C command tree.
  • .sent: The TRIGger:A:BUS:B<x>:SENT command tree.
  • .spi: The TRIGger:A:BUS:B<x>:SPI command tree.

source property

Return the TRIGger:A:BUS:SOUrce command.

Description
  • This command sets or queries the source bus for a bus trigger.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:SOUrce value command.
SCPI Syntax
- TRIGger:A:BUS:SOUrce B<x>
- TRIGger:A:BUS:SOUrce?
Info
  • B<x> sets the selected source to the bus.

TriggerABusBItem

Bases: ValidatedDynamicNumberCmd, SCPICmdRead

The TRIGger:A:BUS:B<x> command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>? query and raise an AssertionError if the returned value does not match value.
Properties
  • .can: The TRIGger:A:BUS:B<x>:CAN command tree.
  • .i2c: The TRIGger:A:BUS:B<x>:I2C command tree.
  • .lin: The TRIGger:A:BUS:B<x>:LIN command tree.
  • .parallel: The TRIGger:A:BUS:B<x>:PARallel command tree.
  • .rs232c: The TRIGger:A:BUS:B<x>:RS232C command tree.
  • .sent: The TRIGger:A:BUS:B<x>:SENT command tree.
  • .spi: The TRIGger:A:BUS:B<x>:SPI command tree.

can property

Return the TRIGger:A:BUS:B<x>:CAN command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .condition: The TRIGger:A:BUS:B<x>:CAN:CONDition command.
  • .data: The TRIGger:A:BUS:B<x>:CAN:DATa command tree.
  • .errtype: The TRIGger:A:BUS:B<x>:CAN:ERRType command.
  • .fd: The TRIGger:A:BUS:B<x>:CAN:FD command tree.
  • .frametype: The TRIGger:A:BUS:B<x>:CAN:FRAMEtype command.
  • .identifier: The TRIGger:A:BUS:B<x>:CAN:IDentifier command tree.

i2c property

Return the TRIGger:A:BUS:B<x>:I2C command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .address: The TRIGger:A:BUS:B<x>:I2C:ADDRess command tree.
  • .condition: The TRIGger:A:BUS:B<x>:I2C:CONDition command.
  • .data: The TRIGger:A:BUS:B<x>:I2C:DATa command tree.

lin property

Return the TRIGger:A:BUS:B<x>:LIN command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .condition: The TRIGger:A:BUS:B<x>:LIN:CONDition command.
  • .data: The TRIGger:A:BUS:B<x>:LIN:DATa command tree.
  • .errtype: The TRIGger:A:BUS:B<x>:LIN:ERRTYPE command.
  • .identifier: The TRIGger:A:BUS:B<x>:LIN:IDentifier command tree.

parallel property

Return the TRIGger:A:BUS:B<x>:PARallel command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:PARallel? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:PARallel? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .data: The TRIGger:A:BUS:B<x>:PARallel:DATa command tree.

rs232c property

Return the TRIGger:A:BUS:B<x>:RS232C command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .condition: The TRIGger:A:BUS:B<x>:RS232C:CONDition command.
  • .data: The TRIGger:A:BUS:B<x>:RS232C:DATa command tree.

sent property

Return the TRIGger:A:BUS:B<x>:SENT command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT? query and raise an AssertionError if the returned value does not match value.
Info
  • B<x> is the number of the bus waveform.
Sub-properties
  • .condition: The TRIGger:A:BUS:B<x>:SENT:CONDition command.
  • .errtype: The TRIGger:A:BUS:B<x>:SENT:ERRType command.
  • .fast: The TRIGger:A:BUS:B<x>:SENT:FAST command tree.
  • .pause: The TRIGger:A:BUS:B<x>:SENT:PAUSE command tree.
  • .slow: The TRIGger:A:BUS:B<x>:SENT:SLOW command tree.

spi property

Return the TRIGger:A:BUS:B<x>:SPI command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .condition: The TRIGger:A:BUS:B<x>:SPI:CONDition command.
  • .data: The TRIGger:A:BUS:B<x>:SPI:DATa command tree.

TriggerABusBItemCan

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN? query and raise an AssertionError if the returned value does not match value.
Properties
  • .condition: The TRIGger:A:BUS:B<x>:CAN:CONDition command.
  • .data: The TRIGger:A:BUS:B<x>:CAN:DATa command tree.
  • .errtype: The TRIGger:A:BUS:B<x>:CAN:ERRType command.
  • .fd: The TRIGger:A:BUS:B<x>:CAN:FD command tree.
  • .frametype: The TRIGger:A:BUS:B<x>:CAN:FRAMEtype command.
  • .identifier: The TRIGger:A:BUS:B<x>:CAN:IDentifier command tree.

condition property

Return the TRIGger:A:BUS:B<x>:CAN:CONDition command.

Description
  • This command sets the condition (start of frame, frame type, identifier, matching data, EOF, missing ACK field, bit-stuffing error) to be used when triggering on a CAN bus signal. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:CONDition {SOF|FRAMEtype|IDentifier|DATa|IDANDDATA|EOF|ERRor|FDBITS}
- TRIGger:A:BUS:B<x>:CAN:CONDition?
Info
  • SOF enables triggering on the start of frame.
  • FDBITS enables triggering on the values of the BRS and ESI bits in an FD packet.
  • FRAMEtype enables triggering on the type of frame.
  • IDentifier enables triggering on a matching identifier.
  • DATa enables triggering on matching data.
  • IDANDDATA enables triggering on a matching identifier and matching data.
  • EOF enables triggering on the end of frame.
  • ERRor enables triggering on a specified error condition.

data property

Return the TRIGger:A:BUS:B<x>:CAN:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .direction: The TRIGger:A:BUS:B<x>:CAN:DATa:DIRection command.
  • .offset: The TRIGger:A:BUS:B<x>:CAN:DATa:OFFSet command.
  • .qualifier: The TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier command.
  • .size: The TRIGger:A:BUS:B<x>:CAN:DATa:SIZe command.
  • .value: The TRIGger:A:BUS:B<x>:CAN:DATa:VALue command.

errtype property

Return the TRIGger:A:BUS:B<x>:CAN:ERRType command.

Description
  • This command sets or queries the type of error condition for a CAN bus to triggering on. The bus number is specified by x. The trigger condition must be set to ERRor.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:ERRType? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:ERRType? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:ERRType value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:ERRType {ACKMISS|BITSTUFFing|FORMERRor|ANYERRor}
- TRIGger:A:BUS:B<x>:CAN:ERRType?
Info
  • ACKMISS specifies triggering on a missing ACK field.
  • BITSTUFFing specifies triggering on a bit stuffing error.
  • FORMERRor specifies triggering on a CAN FD form error. To use this option, the CAN standard must be set to FDISO or FDNONISO.
  • ANYERRor specifies triggering on any error type.

fd property

Return the TRIGger:A:BUS:B<x>:CAN:FD command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:FD? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:FD? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .brsbit: The TRIGger:A:BUS:B<x>:CAN:FD:BRSBit command.
  • .esibit: The TRIGger:A:BUS:B<x>:CAN:FD:ESIBit command.

frametype property

Return the TRIGger:A:BUS:B<x>:CAN:FRAMEtype command.

Description
  • This command sets the frame type (data, remote, error or overload) to be used when triggering on a CAN bus signal. The trigger condition must be set to FRAMEtype (using TRIGGER:A:BUS:BX:CAN:CONDITION). B is the bus number.The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:FRAMEtype? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:FRAMEtype? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:FRAMEtype value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:FRAMEtype {DATa|REMote|ERRor|OVERLoad}
- TRIGger:A:BUS:B<x>:CAN:FRAMEtype?
Info
  • DATa specifies a data frame type.
  • REMote specifies a remote frame type.
  • ERRor specifies an error frame type.
  • OVERLoad specifies an overload frame type.

identifier property

Return the TRIGger:A:BUS:B<x>:CAN:IDentifier command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .mode: The TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe command.
  • .value: The TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue command.

TriggerABusBItemCanCondition

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:CONDition command.

Description
  • This command sets the condition (start of frame, frame type, identifier, matching data, EOF, missing ACK field, bit-stuffing error) to be used when triggering on a CAN bus signal. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:CONDition {SOF|FRAMEtype|IDentifier|DATa|IDANDDATA|EOF|ERRor|FDBITS}
- TRIGger:A:BUS:B<x>:CAN:CONDition?
Info
  • SOF enables triggering on the start of frame.
  • FDBITS enables triggering on the values of the BRS and ESI bits in an FD packet.
  • FRAMEtype enables triggering on the type of frame.
  • IDentifier enables triggering on a matching identifier.
  • DATa enables triggering on matching data.
  • IDANDDATA enables triggering on a matching identifier and matching data.
  • EOF enables triggering on the end of frame.
  • ERRor enables triggering on a specified error condition.

TriggerABusBItemCanData

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa? query and raise an AssertionError if the returned value does not match value.
Properties
  • .direction: The TRIGger:A:BUS:B<x>:CAN:DATa:DIRection command.
  • .offset: The TRIGger:A:BUS:B<x>:CAN:DATa:OFFSet command.
  • .qualifier: The TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier command.
  • .size: The TRIGger:A:BUS:B<x>:CAN:DATa:SIZe command.
  • .value: The TRIGger:A:BUS:B<x>:CAN:DATa:VALue command.

direction property

Return the TRIGger:A:BUS:B<x>:CAN:DATa:DIRection command.

Description
  • This command sets the data direction (read, write or ‘nocare’) to be used to search on a CAN bus signal. The trigger condition must be set to IDentifier (using TRIGGER:A:BUS:BX:CAN:CONDITION). The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:DATa:DIRection? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:DIRection? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:DIRection value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:DATa:DIRection {READ|WRITE|NOCARE}
- TRIGger:A:BUS:B<x>:CAN:DATa:DIRection?
Info
  • READ sets the CAN data direction to READ.
  • WRITE sets the CAN data direction to WRITE.
  • NOCARE sets the CAN data direction to either.

offset property

Return the TRIGger:A:BUS:B<x>:CAN:DATa:OFFSet command.

Description
  • This command sets or queries the data offset value, in bytes, to use when triggering on the CAN data field. The bus number is specified by x. The trigger condition must be set to DATA or IDANDDATA.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:DATa:OFFSet? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:OFFSet? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:OFFSet value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:DATa:OFFSet <NR1>
- TRIGger:A:BUS:B<x>:CAN:DATa:OFFSet?
Info
  • <NR1> is an integer whose minimum and default values are -1 (don’t care), and the maximum is up to 7 (for CAN 2.0) or up to 63 (for ISO CAN FD and Non-ISO CAN FD).

qualifier property

Return the TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier command.

Description
  • This command sets the qualifier (<, >, =, ≠, ≤, ≥) to be used when triggering on a CAN bus signal. The trigger condition must be set to IDANDDATA or DATa (using TRIGGER:A:BUS:BX:CAN:CONDITION). The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier {LESSthan|MOREthan|EQual|UNEQual|LESSEQual|MOREEQual}
- TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier?
Info
  • LESSthan sets the instrument to trigger when the data is less than the qualifier value.
  • MOREthan sets the instrument to trigger when the data is greater than the qualifier value.
  • EQual sets the instrument to trigger when the data is equal to the qualifier value.
  • UNEQual sets the instrument to trigger when the data is not equal to the qualifier value.
  • LESSEQual sets the instrument to trigger when the data is less than or equal to the qualifier value.
  • MOREEQual sets the instrument to trigger when the data is greater than or equal to the qualifier value.

size property

Return the TRIGger:A:BUS:B<x>:CAN:DATa:SIZe command.

Description
  • This command sets the length of the data string, in bytes, to be used when triggering on a CAN bus signal. The trigger condition must be set to IDANDDATA or DATa (using TRIGGER:A:BUS:BX:CAN:CONDITION). The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:CAN:DATa:SIZe?
Info
  • <NR1> is the length of the data string in bytes.

value property

Return the TRIGger:A:BUS:B<x>:CAN:DATa:VALue command.

Description
  • This command sets the binary data value to be used when triggering on a CAN bus signal. The trigger condition must be set to IDANDDATA or DATa (using TRIGGER:A:BUS:BX:CAN:CONDITION). The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:CAN:DATa:VALue?
Info
  • <QString> is the data value in binary format. The only allowed characters in the QString are 0, 1, and X.

TriggerABusBItemCanDataDirection

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:DATa:DIRection command.

Description
  • This command sets the data direction (read, write or ‘nocare’) to be used to search on a CAN bus signal. The trigger condition must be set to IDentifier (using TRIGGER:A:BUS:BX:CAN:CONDITION). The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:DATa:DIRection? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:DIRection? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:DIRection value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:DATa:DIRection {READ|WRITE|NOCARE}
- TRIGger:A:BUS:B<x>:CAN:DATa:DIRection?
Info
  • READ sets the CAN data direction to READ.
  • WRITE sets the CAN data direction to WRITE.
  • NOCARE sets the CAN data direction to either.

TriggerABusBItemCanDataOffset

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:DATa:OFFSet command.

Description
  • This command sets or queries the data offset value, in bytes, to use when triggering on the CAN data field. The bus number is specified by x. The trigger condition must be set to DATA or IDANDDATA.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:DATa:OFFSet? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:OFFSet? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:OFFSet value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:DATa:OFFSet <NR1>
- TRIGger:A:BUS:B<x>:CAN:DATa:OFFSet?
Info
  • <NR1> is an integer whose minimum and default values are -1 (don’t care), and the maximum is up to 7 (for CAN 2.0) or up to 63 (for ISO CAN FD and Non-ISO CAN FD).

TriggerABusBItemCanDataQualifier

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier command.

Description
  • This command sets the qualifier (<, >, =, ≠, ≤, ≥) to be used when triggering on a CAN bus signal. The trigger condition must be set to IDANDDATA or DATa (using TRIGGER:A:BUS:BX:CAN:CONDITION). The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier {LESSthan|MOREthan|EQual|UNEQual|LESSEQual|MOREEQual}
- TRIGger:A:BUS:B<x>:CAN:DATa:QUALifier?
Info
  • LESSthan sets the instrument to trigger when the data is less than the qualifier value.
  • MOREthan sets the instrument to trigger when the data is greater than the qualifier value.
  • EQual sets the instrument to trigger when the data is equal to the qualifier value.
  • UNEQual sets the instrument to trigger when the data is not equal to the qualifier value.
  • LESSEQual sets the instrument to trigger when the data is less than or equal to the qualifier value.
  • MOREEQual sets the instrument to trigger when the data is greater than or equal to the qualifier value.

TriggerABusBItemCanDataSize

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:DATa:SIZe command.

Description
  • This command sets the length of the data string, in bytes, to be used when triggering on a CAN bus signal. The trigger condition must be set to IDANDDATA or DATa (using TRIGGER:A:BUS:BX:CAN:CONDITION). The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:CAN:DATa:SIZe?
Info
  • <NR1> is the length of the data string in bytes.

TriggerABusBItemCanDataValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:DATa:VALue command.

Description
  • This command sets the binary data value to be used when triggering on a CAN bus signal. The trigger condition must be set to IDANDDATA or DATa (using TRIGGER:A:BUS:BX:CAN:CONDITION). The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:DATa:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:CAN:DATa:VALue?
Info
  • <QString> is the data value in binary format. The only allowed characters in the QString are 0, 1, and X.

TriggerABusBItemCanErrtype

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:ERRType command.

Description
  • This command sets or queries the type of error condition for a CAN bus to triggering on. The bus number is specified by x. The trigger condition must be set to ERRor.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:ERRType? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:ERRType? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:ERRType value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:ERRType {ACKMISS|BITSTUFFing|FORMERRor|ANYERRor}
- TRIGger:A:BUS:B<x>:CAN:ERRType?
Info
  • ACKMISS specifies triggering on a missing ACK field.
  • BITSTUFFing specifies triggering on a bit stuffing error.
  • FORMERRor specifies triggering on a CAN FD form error. To use this option, the CAN standard must be set to FDISO or FDNONISO.
  • ANYERRor specifies triggering on any error type.

TriggerABusBItemCanFd

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:FD command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:FD? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:FD? query and raise an AssertionError if the returned value does not match value.
Properties
  • .brsbit: The TRIGger:A:BUS:B<x>:CAN:FD:BRSBit command.
  • .esibit: The TRIGger:A:BUS:B<x>:CAN:FD:ESIBit command.

brsbit property

Return the TRIGger:A:BUS:B<x>:CAN:FD:BRSBit command.

Description
  • This command sets or queries the value of the bit rate switch bit (BRS bit) for a CAN bus to triggering on. The bus number is specified by x. The trigger condition must be set to FDBITS, and the CAN standard must be FDISO or FDNONISO.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:FD:BRSBit? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:FD:BRSBit? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:FD:BRSBit value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:FD:BRSBit {ONE|ZERo|NOCARE}
- TRIGger:A:BUS:B<x>:CAN:FD:BRSBit?
Info
  • ONE filters CAN FD packets to only match those where the BRS bit has a value of 1 (fast data enabled).
  • ZERo filters CAN FD packets to only match those where the BRS bit has a value of 0 (fast data disabled).
  • NOCARE disables filtering of CAN FD packets on the BRS bit.

esibit property

Return the TRIGger:A:BUS:B<x>:CAN:FD:ESIBit command.

Description
  • This command sets or queries the value of the error state indicator bit (ESI bit) for a CAN bus to triggering on. The bus number is specified by x. The trigger condition must be set to FDBITS, and the CAN standard must be FDISO or FDNONISO.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:FD:ESIBit? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:FD:ESIBit? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:FD:ESIBit value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:FD:ESIBit {ONE|ZERo|NOCARE}
- TRIGger:A:BUS:B<x>:CAN:FD:ESIBit?
Info
  • ONE filters CAN FD packets to only match those where the ESI bit has a value of 1 (recessive).
  • ZERo filters CAN FD packets to only match those where the ESI bit has a value of 0 (dominant).
  • NOCARE disables filtering of CAN FD packets on the ESI bit.

TriggerABusBItemCanFdBrsbit

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:FD:BRSBit command.

Description
  • This command sets or queries the value of the bit rate switch bit (BRS bit) for a CAN bus to triggering on. The bus number is specified by x. The trigger condition must be set to FDBITS, and the CAN standard must be FDISO or FDNONISO.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:FD:BRSBit? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:FD:BRSBit? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:FD:BRSBit value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:FD:BRSBit {ONE|ZERo|NOCARE}
- TRIGger:A:BUS:B<x>:CAN:FD:BRSBit?
Info
  • ONE filters CAN FD packets to only match those where the BRS bit has a value of 1 (fast data enabled).
  • ZERo filters CAN FD packets to only match those where the BRS bit has a value of 0 (fast data disabled).
  • NOCARE disables filtering of CAN FD packets on the BRS bit.

TriggerABusBItemCanFdEsibit

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:FD:ESIBit command.

Description
  • This command sets or queries the value of the error state indicator bit (ESI bit) for a CAN bus to triggering on. The bus number is specified by x. The trigger condition must be set to FDBITS, and the CAN standard must be FDISO or FDNONISO.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:FD:ESIBit? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:FD:ESIBit? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:FD:ESIBit value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:FD:ESIBit {ONE|ZERo|NOCARE}
- TRIGger:A:BUS:B<x>:CAN:FD:ESIBit?
Info
  • ONE filters CAN FD packets to only match those where the ESI bit has a value of 1 (recessive).
  • ZERo filters CAN FD packets to only match those where the ESI bit has a value of 0 (dominant).
  • NOCARE disables filtering of CAN FD packets on the ESI bit.

TriggerABusBItemCanFrametype

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:FRAMEtype command.

Description
  • This command sets the frame type (data, remote, error or overload) to be used when triggering on a CAN bus signal. The trigger condition must be set to FRAMEtype (using TRIGGER:A:BUS:BX:CAN:CONDITION). B is the bus number.The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:FRAMEtype? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:FRAMEtype? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:FRAMEtype value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:FRAMEtype {DATa|REMote|ERRor|OVERLoad}
- TRIGger:A:BUS:B<x>:CAN:FRAMEtype?
Info
  • DATa specifies a data frame type.
  • REMote specifies a remote frame type.
  • ERRor specifies an error frame type.
  • OVERLoad specifies an overload frame type.

TriggerABusBItemCanIdentifier

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:IDentifier command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier? query and raise an AssertionError if the returned value does not match value.
Properties
  • .mode: The TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe command.
  • .value: The TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue command.

mode property

Return the TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe command.

Description
  • This command sets the addressing mode (standard or extended format) to be used when triggering on a CAN bus signal. The trigger condition must be set to IDANDDATA or DATa (using TRIGGER:A:BUS:BX:CAN:CONDITION). The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe {STandard|EXTended}
- TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe?
Info
  • STandard specifies the standard addressing mode.
  • EXTended specifies the extended addressing mode.

value property

Return the TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue command.

Description
  • This command sets the binary address value to be used when triggering on a CAN bus signal. The trigger condition must be set to IDANDDATA or DATa (using TRIGGER:A:BUS:BX:CAN:CONDITION). The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue <QString>
- TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue?
Info
  • <QString> is up to 29 bits specifying the binary identifier value. The only allowed characters in the QString are 0, 1, and X.

TriggerABusBItemCanIdentifierMode

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe command.

Description
  • This command sets the addressing mode (standard or extended format) to be used when triggering on a CAN bus signal. The trigger condition must be set to IDANDDATA or DATa (using TRIGGER:A:BUS:BX:CAN:CONDITION). The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe {STandard|EXTended}
- TRIGger:A:BUS:B<x>:CAN:IDentifier:MODe?
Info
  • STandard specifies the standard addressing mode.
  • EXTended specifies the extended addressing mode.

TriggerABusBItemCanIdentifierValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue command.

Description
  • This command sets the binary address value to be used when triggering on a CAN bus signal. The trigger condition must be set to IDANDDATA or DATa (using TRIGGER:A:BUS:BX:CAN:CONDITION). The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue <QString>
- TRIGger:A:BUS:B<x>:CAN:IDentifier:VALue?
Info
  • <QString> is up to 29 bits specifying the binary identifier value. The only allowed characters in the QString are 0, 1, and X.

TriggerABusBItemI2c

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:I2C command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C? query and raise an AssertionError if the returned value does not match value.
Properties
  • .address: The TRIGger:A:BUS:B<x>:I2C:ADDRess command tree.
  • .condition: The TRIGger:A:BUS:B<x>:I2C:CONDition command.
  • .data: The TRIGger:A:BUS:B<x>:I2C:DATa command tree.

address property

Return the TRIGger:A:BUS:B<x>:I2C:ADDRess command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .mode: The TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe command.
  • .value: The TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue command.

condition property

Return the TRIGger:A:BUS:B<x>:I2C:CONDition command.

Description
  • This command specifies the trigger condition for an I 2 C trigger. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:CONDition {STARt|STOP|REPEATstart|ACKMISS|ADDRess|DATa|ADDRANDDATA}
- TRIGger:A:BUS:B<x>:I2C:CONDition?
Info
  • STARt specifies a search based on start condition.
  • STOP specifies a search based on stop condition.
  • REPEATstart specifies a search based on repeat of start condition.
  • ACKMISS specifies a search based on missing acknowledgement condition.
  • ADDRess specifies a search based on address.
  • DATa specifies a search based on data.
  • ADDRANDDATA specifies a search based on address and data.

data property

Return the TRIGger:A:BUS:B<x>:I2C:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .direction: The TRIGger:A:BUS:B<x>:I2C:DATa:DIRection command.
  • .size: The TRIGger:A:BUS:B<x>:I2C:DATa:SIZe command.
  • .value: The TRIGger:A:BUS:B<x>:I2C:DATa:VALue command.

TriggerABusBItemI2cAddress

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:I2C:ADDRess command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess? query and raise an AssertionError if the returned value does not match value.
Properties
  • .mode: The TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe command.
  • .value: The TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue command.

mode property

Return the TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe command.

Description
  • This command specifies the I 2 C address mode to 7 or 10-bit. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe {ADDR7|ADDR10}
- TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe?
Info
  • ADDR7 specifies the 7-bit I2C address mode.
  • ADDR10 specifies the 10-bit I2C address mode.

value property

Return the TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue command.

Description
  • This command specifies the binary address string used for the I 2 C trigger if the trigger condition is ADDRESS or ADDRANDDATA. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue <QString>
- TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue?
Info
  • <QString> is up to 7 or 10-bits depending on the address mode that specifies the address. The only allowed characters in the QString are 0, 1, and X.

TriggerABusBItemI2cAddressMode

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe command.

Description
  • This command specifies the I 2 C address mode to 7 or 10-bit. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe {ADDR7|ADDR10}
- TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe?
Info
  • ADDR7 specifies the 7-bit I2C address mode.
  • ADDR10 specifies the 10-bit I2C address mode.

TriggerABusBItemI2cAddressValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue command.

Description
  • This command specifies the binary address string used for the I 2 C trigger if the trigger condition is ADDRESS or ADDRANDDATA. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue <QString>
- TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue?
Info
  • <QString> is up to 7 or 10-bits depending on the address mode that specifies the address. The only allowed characters in the QString are 0, 1, and X.

TriggerABusBItemI2cCondition

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:I2C:CONDition command.

Description
  • This command specifies the trigger condition for an I 2 C trigger. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:CONDition {STARt|STOP|REPEATstart|ACKMISS|ADDRess|DATa|ADDRANDDATA}
- TRIGger:A:BUS:B<x>:I2C:CONDition?
Info
  • STARt specifies a search based on start condition.
  • STOP specifies a search based on stop condition.
  • REPEATstart specifies a search based on repeat of start condition.
  • ACKMISS specifies a search based on missing acknowledgement condition.
  • ADDRess specifies a search based on address.
  • DATa specifies a search based on data.
  • ADDRANDDATA specifies a search based on address and data.

TriggerABusBItemI2cData

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:I2C:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa? query and raise an AssertionError if the returned value does not match value.
Properties
  • .direction: The TRIGger:A:BUS:B<x>:I2C:DATa:DIRection command.
  • .size: The TRIGger:A:BUS:B<x>:I2C:DATa:SIZe command.
  • .value: The TRIGger:A:BUS:B<x>:I2C:DATa:VALue command.

direction property

Return the TRIGger:A:BUS:B<x>:I2C:DATa:DIRection command.

Description
  • This command specifies the I 2 C trigger type to be valid on a Read, Write, or Either condition. Read or write is indicated by the R/W bit in the I 2 C protocol. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:DATa:DIRection? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa:DIRection? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa:DIRection value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:DATa:DIRection {READ|WRITE|NOCARE}
- TRIGger:A:BUS:B<x>:I2C:DATa:DIRection?
Info
  • READ specifies read as the data direction.
  • WRITE specifies write as the data direction.
  • NOCARE specifies either as the data direction.

size property

Return the TRIGger:A:BUS:B<x>:I2C:DATa:SIZe command.

Description
  • This command specifies the length of the data string in bytes to be used for an I2C trigger if the trigger condition is DATA or ADDRANDDATA. Applies to bus , where the bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:I2C:DATa:SIZe?
Info
  • <NR1> is the length of the data string in bytes.

value property

Return the TRIGger:A:BUS:B<x>:I2C:DATa:VALue command.

Description
  • This command specifies the binary data string used for I2C triggering if the trigger condition is DATA or ADDRANDDATA. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:I2C:DATa:VALue?
Info
  • <QString> is the binary data string, where the number of bits is 8 times the number of bytes specified. The only allowed characters in the string are 0, 1, and X.

TriggerABusBItemI2cDataDirection

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:I2C:DATa:DIRection command.

Description
  • This command specifies the I 2 C trigger type to be valid on a Read, Write, or Either condition. Read or write is indicated by the R/W bit in the I 2 C protocol. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:DATa:DIRection? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa:DIRection? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa:DIRection value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:DATa:DIRection {READ|WRITE|NOCARE}
- TRIGger:A:BUS:B<x>:I2C:DATa:DIRection?
Info
  • READ specifies read as the data direction.
  • WRITE specifies write as the data direction.
  • NOCARE specifies either as the data direction.

TriggerABusBItemI2cDataSize

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:I2C:DATa:SIZe command.

Description
  • This command specifies the length of the data string in bytes to be used for an I2C trigger if the trigger condition is DATA or ADDRANDDATA. Applies to bus , where the bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:I2C:DATa:SIZe?
Info
  • <NR1> is the length of the data string in bytes.

TriggerABusBItemI2cDataValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:I2C:DATa:VALue command.

Description
  • This command specifies the binary data string used for I2C triggering if the trigger condition is DATA or ADDRANDDATA. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:I2C:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:I2C:DATa:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:I2C:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:I2C:DATa:VALue?
Info
  • <QString> is the binary data string, where the number of bits is 8 times the number of bytes specified. The only allowed characters in the string are 0, 1, and X.

TriggerABusBItemLin

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:LIN command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN? query and raise an AssertionError if the returned value does not match value.
Properties
  • .condition: The TRIGger:A:BUS:B<x>:LIN:CONDition command.
  • .data: The TRIGger:A:BUS:B<x>:LIN:DATa command tree.
  • .errtype: The TRIGger:A:BUS:B<x>:LIN:ERRTYPE command.
  • .identifier: The TRIGger:A:BUS:B<x>:LIN:IDentifier command tree.

condition property

Return the TRIGger:A:BUS:B<x>:LIN:CONDition command.

Description
  • This command specifies the trigger condition for LIN. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:CONDition {SYNCfield|IDentifier|DATa|IDANDDATA|WAKEup|SLEEP|ERRor}
- TRIGger:A:BUS:B<x>:LIN:CONDition?
Info
  • SYNCfield sets the LIN trigger condition to sync field.
  • IDentifier sets the LIN trigger condition to identifier.
  • DATa sets the LIN trigger condition to data.
  • IDANDDATA sets the LIN trigger condition to id and data.
  • WAKEup sets the LIN trigger condition to wake up.
  • SLEEP sets the LIN trigger condition to sleep.
  • ERRor sets the LIN trigger condition to error.

data property

Return the TRIGger:A:BUS:B<x>:LIN:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .hivalue: The TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue command.
  • .qualifier: The TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier command.
  • .size: The TRIGger:A:BUS:B<x>:LIN:DATa:SIZe command.
  • .value: The TRIGger:A:BUS:B<x>:LIN:DATa:VALue command.

errtype property

Return the TRIGger:A:BUS:B<x>:LIN:ERRTYPE command.

Description
  • This command specifies the error type be used for LIN trigger. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:ERRTYPE? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:ERRTYPE? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:ERRTYPE value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:ERRTYPE {SYNC|PARity|CHecksum}
- TRIGger:A:BUS:B<x>:LIN:ERRTYPE?
Info
  • SYNC sets the LIN error type to SYNC.
  • PARity sets the LIN error type to parity.
  • CHecksum sets the LIN error type to checksum.

identifier property

Return the TRIGger:A:BUS:B<x>:LIN:IDentifier command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:IDentifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:IDentifier? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .value: The TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue command.

TriggerABusBItemLinCondition

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:LIN:CONDition command.

Description
  • This command specifies the trigger condition for LIN. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:CONDition {SYNCfield|IDentifier|DATa|IDANDDATA|WAKEup|SLEEP|ERRor}
- TRIGger:A:BUS:B<x>:LIN:CONDition?
Info
  • SYNCfield sets the LIN trigger condition to sync field.
  • IDentifier sets the LIN trigger condition to identifier.
  • DATa sets the LIN trigger condition to data.
  • IDANDDATA sets the LIN trigger condition to id and data.
  • WAKEup sets the LIN trigger condition to wake up.
  • SLEEP sets the LIN trigger condition to sleep.
  • ERRor sets the LIN trigger condition to error.

TriggerABusBItemLinData

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:LIN:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa? query and raise an AssertionError if the returned value does not match value.
Properties
  • .hivalue: The TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue command.
  • .qualifier: The TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier command.
  • .size: The TRIGger:A:BUS:B<x>:LIN:DATa:SIZe command.
  • .value: The TRIGger:A:BUS:B<x>:LIN:DATa:VALue command.

hivalue property

Return the TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue command.

Description
  • This command specifies the high data value string used for a LIN bus trigger when the trigger condition is DATA or IDANDDATA and the data qualifier is INRANGE or OUTRANGE. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue <QString>
- TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue?
Info
  • <QString> is a quoted string that is the binary data string used for LIN trigger if the trigger condition is ID or IDANDDATA.

qualifier property

Return the TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier command.

Description
  • This command specifies the LIN data qualifier. This only applies if the trigger condition is IDANDDATA or DATA. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier {LESSthan|MOREthan|EQual|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier?
Info
  • LESSthan sets the LIN data qualifier to less than.
  • MOREthan sets the LIN data qualifier to greater than.
  • EQual sets the LIN data qualifier to equal.
  • UNEQual sets the LIN data qualifier to not equal.
  • LESSEQual sets the LIN data qualifier to less than or equal.
  • MOREEQual sets the LIN data qualifier to greater than or equal.
  • INrange sets the LIN data qualifier to in range.
  • OUTrange sets the LIN data qualifier to out of range.

size property

Return the TRIGger:A:BUS:B<x>:LIN:DATa:SIZe command.

Description
  • This command specifies the length of the data string in bytes to be used for LIN trigger. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:LIN:DATa:SIZe?
Info
  • <NR1> is the size of the data string in bytes.

value property

Return the TRIGger:A:BUS:B<x>:LIN:DATa:VALue command.

Description
  • This command specifies the binary data string to be used for LIN trigger condition if trigger condition is ID or IDANDDATA. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:LIN:DATa:VALue?
Info
  • <QString> is a quoted string that is the LIN trigger data value.

TriggerABusBItemLinDataHivalue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue command.

Description
  • This command specifies the high data value string used for a LIN bus trigger when the trigger condition is DATA or IDANDDATA and the data qualifier is INRANGE or OUTRANGE. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue <QString>
- TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue?
Info
  • <QString> is a quoted string that is the binary data string used for LIN trigger if the trigger condition is ID or IDANDDATA.

TriggerABusBItemLinDataQualifier

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier command.

Description
  • This command specifies the LIN data qualifier. This only applies if the trigger condition is IDANDDATA or DATA. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier {LESSthan|MOREthan|EQual|UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier?
Info
  • LESSthan sets the LIN data qualifier to less than.
  • MOREthan sets the LIN data qualifier to greater than.
  • EQual sets the LIN data qualifier to equal.
  • UNEQual sets the LIN data qualifier to not equal.
  • LESSEQual sets the LIN data qualifier to less than or equal.
  • MOREEQual sets the LIN data qualifier to greater than or equal.
  • INrange sets the LIN data qualifier to in range.
  • OUTrange sets the LIN data qualifier to out of range.

TriggerABusBItemLinDataSize

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:LIN:DATa:SIZe command.

Description
  • This command specifies the length of the data string in bytes to be used for LIN trigger. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:LIN:DATa:SIZe?
Info
  • <NR1> is the size of the data string in bytes.

TriggerABusBItemLinDataValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:LIN:DATa:VALue command.

Description
  • This command specifies the binary data string to be used for LIN trigger condition if trigger condition is ID or IDANDDATA. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:DATa:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:LIN:DATa:VALue?
Info
  • <QString> is a quoted string that is the LIN trigger data value.

TriggerABusBItemLinErrtype

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:LIN:ERRTYPE command.

Description
  • This command specifies the error type be used for LIN trigger. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:ERRTYPE? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:ERRTYPE? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:ERRTYPE value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:ERRTYPE {SYNC|PARity|CHecksum}
- TRIGger:A:BUS:B<x>:LIN:ERRTYPE?
Info
  • SYNC sets the LIN error type to SYNC.
  • PARity sets the LIN error type to parity.
  • CHecksum sets the LIN error type to checksum.

TriggerABusBItemLinIdentifier

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:LIN:IDentifier command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:IDentifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:IDentifier? query and raise an AssertionError if the returned value does not match value.
Properties
  • .value: The TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue command.

value property

Return the TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue command.

Description
  • This command specifies the binary address string used for LIN bus trigger if the trigger condition is ID or IDANDDATA. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue <QString>
- TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue?
Info
  • <QString> is the binary address string used for LIN trigger if the trigger condition is ID or IDANDDATA.

TriggerABusBItemLinIdentifierValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue command.

Description
  • This command specifies the binary address string used for LIN bus trigger if the trigger condition is ID or IDANDDATA. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue <QString>
- TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue?
Info
  • <QString> is the binary address string used for LIN trigger if the trigger condition is ID or IDANDDATA.

TriggerABusBItemParallel

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:PARallel command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:PARallel? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:PARallel? query and raise an AssertionError if the returned value does not match value.
Properties
  • .data: The TRIGger:A:BUS:B<x>:PARallel:DATa command tree.

data property

Return the TRIGger:A:BUS:B<x>:PARallel:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:PARallel:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:PARallel:DATa? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .value: The TRIGger:A:BUS:B<x>:PARallel:DATa:VALue command.

TriggerABusBItemParallelData

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:PARallel:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:PARallel:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:PARallel:DATa? query and raise an AssertionError if the returned value does not match value.
Properties
  • .value: The TRIGger:A:BUS:B<x>:PARallel:DATa:VALue command.

value property

Return the TRIGger:A:BUS:B<x>:PARallel:DATa:VALue command.

Description
  • This command specifies the binary data string used for a Parallel Bus trigger. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:PARallel:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:PARallel:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:PARallel:DATa:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:PARallel:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:PARallel:DATa:VALue?
Info
  • <QString> is the binary data string used for a Parallel Bus trigger.

TriggerABusBItemParallelDataValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:PARallel:DATa:VALue command.

Description
  • This command specifies the binary data string used for a Parallel Bus trigger. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:PARallel:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:PARallel:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:PARallel:DATa:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:PARallel:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:PARallel:DATa:VALue?
Info
  • <QString> is the binary data string used for a Parallel Bus trigger.

TriggerABusBItemRs232c

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:RS232C command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C? query and raise an AssertionError if the returned value does not match value.
Properties
  • .condition: The TRIGger:A:BUS:B<x>:RS232C:CONDition command.
  • .data: The TRIGger:A:BUS:B<x>:RS232C:DATa command tree.

condition property

Return the TRIGger:A:BUS:B<x>:RS232C:CONDition command.

Description
  • This command specifies the condition for an RS-232C trigger, where the bus number is specified by< >x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:RS232C:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:RS232C:CONDition {STARt|EOp|DATa|PARItyerror}
- TRIGger:A:BUS:B<x>:RS232C:CONDition?
Info
  • STARt sets the Trigger on condition to Start.
  • EOp sets the Trigger on condition to End of Packet.
  • DATa sets the Trigger on condition to Data.
  • PARItyerror sets the Trigger on condition to Parity Error.

data property

Return the TRIGger:A:BUS:B<x>:RS232C:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:DATa? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .size: The TRIGger:A:BUS:B<x>:RS232C:DATa:SIZe command.
  • .value: The TRIGger:A:BUS:B<x>:RS232C:DATa:VALue command.

TriggerABusBItemRs232cCondition

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:RS232C:CONDition command.

Description
  • This command specifies the condition for an RS-232C trigger, where the bus number is specified by< >x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:RS232C:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:RS232C:CONDition {STARt|EOp|DATa|PARItyerror}
- TRIGger:A:BUS:B<x>:RS232C:CONDition?
Info
  • STARt sets the Trigger on condition to Start.
  • EOp sets the Trigger on condition to End of Packet.
  • DATa sets the Trigger on condition to Data.
  • PARItyerror sets the Trigger on condition to Parity Error.

TriggerABusBItemRs232cData

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:RS232C:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:DATa? query and raise an AssertionError if the returned value does not match value.
Properties
  • .size: The TRIGger:A:BUS:B<x>:RS232C:DATa:SIZe command.
  • .value: The TRIGger:A:BUS:B<x>:RS232C:DATa:VALue command.

size property

Return the TRIGger:A:BUS:B<x>:RS232C:DATa:SIZe command.

Description
  • This command sets or queries the length of the data string in bytes to be used for an RS-232C trigger when the trigger condition is Data. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:RS232C:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:RS232C:DATa:SIZe <NR3>
- TRIGger:A:BUS:B<x>:RS232C:DATa:SIZe?
Info
  • <NR3> specifies the data size in bytes.

value property

Return the TRIGger:A:BUS:B<x>:RS232C:DATa:VALue command.

Description
  • This command sets or queries the data address string used for the RS-232 bus trigger when the trigger condition is set to Data. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:RS232C:DATa:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:RS232C:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:RS232C:DATa:VALue?
Info
  • <QString> specifies the address value. The argument is a string of 0, 1, or X representing a binary number.

TriggerABusBItemRs232cDataSize

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:RS232C:DATa:SIZe command.

Description
  • This command sets or queries the length of the data string in bytes to be used for an RS-232C trigger when the trigger condition is Data. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:RS232C:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:RS232C:DATa:SIZe <NR3>
- TRIGger:A:BUS:B<x>:RS232C:DATa:SIZe?
Info
  • <NR3> specifies the data size in bytes.

TriggerABusBItemRs232cDataValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:RS232C:DATa:VALue command.

Description
  • This command sets or queries the data address string used for the RS-232 bus trigger when the trigger condition is set to Data. The bus number is specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:RS232C:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:RS232C:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:RS232C:DATa:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:RS232C:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:RS232C:DATa:VALue?
Info
  • <QString> specifies the address value. The argument is a string of 0, 1, or X representing a binary number.

TriggerABusBItemSent

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:SENT command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT? query and raise an AssertionError if the returned value does not match value.
Info
  • B<x> is the number of the bus waveform.
Properties
  • .condition: The TRIGger:A:BUS:B<x>:SENT:CONDition command.
  • .errtype: The TRIGger:A:BUS:B<x>:SENT:ERRType command.
  • .fast: The TRIGger:A:BUS:B<x>:SENT:FAST command tree.
  • .pause: The TRIGger:A:BUS:B<x>:SENT:PAUSE command tree.
  • .slow: The TRIGger:A:BUS:B<x>:SENT:SLOW command tree.

condition property

Return the TRIGger:A:BUS:B<x>:SENT:CONDition command.

Description
  • This command sets or queries the trigger condition for a SENT bus.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SENT:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SENT:CONDition {START|FAST|SLOW|ERRor}
- TRIGger:A:BUS:B<x>:SENT:CONDition?
Info
  • B<x> is the number of the bus waveform.
  • START sets triggering on start of packet.
  • FAST sets triggering on fast channel packets.
  • SLOW sets triggering on slow channel packets.
  • ERRor sets triggering on errors.

errtype property

Return the TRIGger:A:BUS:B<x>:SENT:ERRType command.

Description
  • This command sets or queries the error type to be used when triggering on SENT data.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:ERRType? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:ERRType? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SENT:ERRType value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SENT:ERRType CRC
- TRIGger:A:BUS:B<x>:SENT:ERRType?
Info
  • B<x> is the number of the bus waveform.
  • CRC specifies triggering on CRC errors.
Sub-properties
  • .crc: The TRIGger:A:BUS:B<x>:SENT:ERRType:CRC command.

fast property

Return the TRIGger:A:BUS:B<x>:SENT:FAST command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:FAST? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .chan1a: The TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A command tree.
  • .chan2b: The TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B command tree.
  • .counter: The TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer command tree.
  • .invertnibble: The TRIGger:A:BUS:B<x>:SENT:FAST:INVERTNIBble command tree.
  • .status: The TRIGger:A:BUS:B<x>:SENT:FAST:STATus command tree.

pause property

Return the TRIGger:A:BUS:B<x>:SENT:PAUSE command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:PAUSE? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:PAUSE? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .qualifier: The TRIGger:A:BUS:B<x>:SENT:PAUSE:QUALifier command.

slow property

Return the TRIGger:A:BUS:B<x>:SENT:SLOW command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:SLOW? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:SLOW? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .data: The TRIGger:A:BUS:B<x>:SENT:SLOW:DATA command tree.
  • .identifier: The TRIGger:A:BUS:B<x>:SENT:SLOW:IDentifier command tree.

TriggerABusBItemSentCondition

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:SENT:CONDition command.

Description
  • This command sets or queries the trigger condition for a SENT bus.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SENT:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SENT:CONDition {START|FAST|SLOW|ERRor}
- TRIGger:A:BUS:B<x>:SENT:CONDition?
Info
  • B<x> is the number of the bus waveform.
  • START sets triggering on start of packet.
  • FAST sets triggering on fast channel packets.
  • SLOW sets triggering on slow channel packets.
  • ERRor sets triggering on errors.

TriggerABusBItemSentErrtype

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:SENT:ERRType command.

Description
  • This command sets or queries the error type to be used when triggering on SENT data.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:ERRType? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:ERRType? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SENT:ERRType value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SENT:ERRType CRC
- TRIGger:A:BUS:B<x>:SENT:ERRType?
Info
  • B<x> is the number of the bus waveform.
  • CRC specifies triggering on CRC errors.
Properties
  • .crc: The TRIGger:A:BUS:B<x>:SENT:ERRType:CRC command.

crc property

Return the TRIGger:A:BUS:B<x>:SENT:ERRType:CRC command.

Description
  • This command sets or queries the CRC error type to be used when triggering on SENT data.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:ERRType:CRC? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:ERRType:CRC? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SENT:ERRType:CRC value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SENT:ERRType:CRC {FAST|SLOW}
- TRIGger:A:BUS:B<x>:SENT:ERRType:CRC?
Info
  • B<x> is the number of the bus waveform.
  • FAST specifies triggering on CRC errors in only the Fast Channel.
  • SLOW specifies triggering on CRC errors in only the slow channel.

TriggerABusBItemSentErrtypeCrc

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:SENT:ERRType:CRC command.

Description
  • This command sets or queries the CRC error type to be used when triggering on SENT data.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:ERRType:CRC? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:ERRType:CRC? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SENT:ERRType:CRC value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SENT:ERRType:CRC {FAST|SLOW}
- TRIGger:A:BUS:B<x>:SENT:ERRType:CRC?
Info
  • B<x> is the number of the bus waveform.
  • FAST specifies triggering on CRC errors in only the Fast Channel.
  • SLOW specifies triggering on CRC errors in only the slow channel.

TriggerABusBItemSentFast

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:SENT:FAST command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:FAST? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST? query and raise an AssertionError if the returned value does not match value.
Properties
  • .chan1a: The TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A command tree.
  • .chan2b: The TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B command tree.
  • .counter: The TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer command tree.
  • .invertnibble: The TRIGger:A:BUS:B<x>:SENT:FAST:INVERTNIBble command tree.
  • .status: The TRIGger:A:BUS:B<x>:SENT:FAST:STATus command tree.

chan1a property

Return the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .hivalue: The TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:HIVALue command.
  • .qualifier: The TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:QUALifier command.
  • .value: The TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:VALue command.

chan2b property

Return the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .hivalue: The TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:HIVALue command.
  • .qualifier: The TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:QUALifier command.
  • .value: The TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:VALue command.

counter property

Return the TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .hivalue: The TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:HIVALue command.
  • .qualifier: The TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:QUALifier command.
  • .value: The TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:VALue command.

invertnibble property

Return the TRIGger:A:BUS:B<x>:SENT:FAST:INVERTNIBble command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:FAST:INVERTNIBble? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:INVERTNIBble? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .value: The TRIGger:A:BUS:B<x>:SENT:FAST:INVERTNIBble:VALue command.

status property

Return the TRIGger:A:BUS:B<x>:SENT:FAST:STATus command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:FAST:STATus? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:STATus? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .value: The TRIGger:A:BUS:B<x>:SENT:FAST:STATus:VALue command.

TriggerABusBItemSentFastChan1a

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A? query and raise an AssertionError if the returned value does not match value.
Properties
  • .hivalue: The TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:HIVALue command.
  • .qualifier: The TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:QUALifier command.
  • .value: The TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:VALue command.

hivalue property

Return the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:HIVALue command.

Description
  • This command sets or queries the high binary fast channel 1 value to use when triggering on a SENT bus signal. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:HIVALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:HIVALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:HIVALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:HIVALue <QString>
- TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:HIVALue?
Info
  • <Qstring> sets the Fast Channel 1 binary data high value.

qualifier property

Return the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:QUALifier command.

Description
  • This command sets or queries the qualifier to be used when triggering on SENT fast packet bus data for device channel 1. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:QUALifier {EQual|UNEQual|LESSthan|MOREthan|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:QUALifier?
Info
  • EQUal sets the qualifier as Equal.
  • LESSEQual sets the qualifier as Less Than or Equal to.
  • LESSThan sets the qualifier as Less Than.
  • MOREEQual sets the qualifier as More Than or Equal to.
  • MOREThan sets the qualifier as More Than.
  • UNEQual sets the qualifier as Unequal.
  • INrange sets the qualifier to inside a range.
  • OUTrange sets the qualifier to outside a range.

value property

Return the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:VALue command.

Description
  • This command sets or queries the binary fast channel 1 value to be used when triggering on a SENT bus signal. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:VALue <Qstring>
- TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:VALue?
Info
  • <Qstring> is the Fast Channel 1 value on which to trigger.

TriggerABusBItemSentFastChan1aHivalue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:HIVALue command.

Description
  • This command sets or queries the high binary fast channel 1 value to use when triggering on a SENT bus signal. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:HIVALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:HIVALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:HIVALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:HIVALue <QString>
- TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:HIVALue?
Info
  • <Qstring> sets the Fast Channel 1 binary data high value.

TriggerABusBItemSentFastChan1aQualifier

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:QUALifier command.

Description
  • This command sets or queries the qualifier to be used when triggering on SENT fast packet bus data for device channel 1. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:QUALifier {EQual|UNEQual|LESSthan|MOREthan|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:QUALifier?
Info
  • EQUal sets the qualifier as Equal.
  • LESSEQual sets the qualifier as Less Than or Equal to.
  • LESSThan sets the qualifier as Less Than.
  • MOREEQual sets the qualifier as More Than or Equal to.
  • MOREThan sets the qualifier as More Than.
  • UNEQual sets the qualifier as Unequal.
  • INrange sets the qualifier to inside a range.
  • OUTrange sets the qualifier to outside a range.

TriggerABusBItemSentFastChan1aValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:VALue command.

Description
  • This command sets or queries the binary fast channel 1 value to be used when triggering on a SENT bus signal. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:VALue <Qstring>
- TRIGger:A:BUS:B<x>:SENT:FAST:CHAN1A:VALue?
Info
  • <Qstring> is the Fast Channel 1 value on which to trigger.

TriggerABusBItemSentFastChan2b

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B? query and raise an AssertionError if the returned value does not match value.
Properties
  • .hivalue: The TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:HIVALue command.
  • .qualifier: The TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:QUALifier command.
  • .value: The TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:VALue command.

hivalue property

Return the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:HIVALue command.

Description
  • This command sets or queries the high binary fast channel 2 value to use when triggering on a SENT bus signal. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:HIVALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:HIVALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:HIVALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:HIVALue <QString>
- TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:HIVALue?
Info
  • <Qstring> sets the Fast Channel 2 high binary data value.

qualifier property

Return the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:QUALifier command.

Description
  • This command sets or queries the qualifier to be used when triggering on SENT fast packet bus data for device channel 2. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:QUALifier {EQual|UNEQual|LESSthan|MOREthan|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:QUALifier?
Info
  • EQUal sets the qualifier as Equal.
  • LESSEQual sets the qualifier as Less Than or Equal to.
  • LESSThan sets the qualifier as Less Than.
  • MOREEQual sets the qualifier as More Than or Equal to.
  • MOREThan sets the qualifier as More Than.
  • UNEQual sets the qualifier as Unequal.
  • INrange sets the qualifier to inside a range.
  • OUTrange sets the qualifier to outside a range.

value property

Return the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:VALue command.

Description
  • This command sets or queries the binary fast channel 2 value to be used when triggering on a SENT bus signal. The trigger condition must be set to FAST. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:VALue <Qstring>
- TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:VALue?
Info
  • <Qstring> is the Fast Channel 2 binary value on which to trigger.

TriggerABusBItemSentFastChan2bHivalue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:HIVALue command.

Description
  • This command sets or queries the high binary fast channel 2 value to use when triggering on a SENT bus signal. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:HIVALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:HIVALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:HIVALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:HIVALue <QString>
- TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:HIVALue?
Info
  • <Qstring> sets the Fast Channel 2 high binary data value.

TriggerABusBItemSentFastChan2bQualifier

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:QUALifier command.

Description
  • This command sets or queries the qualifier to be used when triggering on SENT fast packet bus data for device channel 2. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:QUALifier {EQual|UNEQual|LESSthan|MOREthan|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:QUALifier?
Info
  • EQUal sets the qualifier as Equal.
  • LESSEQual sets the qualifier as Less Than or Equal to.
  • LESSThan sets the qualifier as Less Than.
  • MOREEQual sets the qualifier as More Than or Equal to.
  • MOREThan sets the qualifier as More Than.
  • UNEQual sets the qualifier as Unequal.
  • INrange sets the qualifier to inside a range.
  • OUTrange sets the qualifier to outside a range.

TriggerABusBItemSentFastChan2bValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:VALue command.

Description
  • This command sets or queries the binary fast channel 2 value to be used when triggering on a SENT bus signal. The trigger condition must be set to FAST. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:VALue <Qstring>
- TRIGger:A:BUS:B<x>:SENT:FAST:CHAN2B:VALue?
Info
  • <Qstring> is the Fast Channel 2 binary value on which to trigger.

TriggerABusBItemSentFastCounter

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer? query and raise an AssertionError if the returned value does not match value.
Properties
  • .hivalue: The TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:HIVALue command.
  • .qualifier: The TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:QUALifier command.
  • .value: The TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:VALue command.

hivalue property

Return the TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:HIVALue command.

Description
  • This command sets or queries the high binary fast message counter value to be used when triggering on a SENT bus signal. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:HIVALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:HIVALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:HIVALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:HIVALue <QString>
- TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:HIVALue?
Info
  • <Qstring> sets the Fast Channel 1 counter binary value.

qualifier property

Return the TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:QUALifier command.

Description
  • This command sets or queries the qualifier to be used when triggering on SENT fast packet bus data for the secure format counter. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:QUALifier {EQual|UNEQual|LESSthan|MOREthan|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:QUALifier?
Info
  • EQUal sets the qualifier as Equal.
  • LESSEQual sets the qualifier as Less Than or Equal to.
  • LESSThan sets the qualifier as Less Than.
  • MOREEQual sets the qualifier as More Than or Equal to.
  • MOREThan sets the qualifier as More Than.
  • UNEQual sets the qualifier as Unequal.
  • INrange sets the qualifier to inside a range.
  • OUTrange sets the qualifier to outside a range.

value property

Return the TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:VALue command.

Description
  • This command sets or queries the binary fast message counter value to be used when triggering on a SENT bus signal. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:VALue <Qstring>
- TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:VALue?
Info
  • <Qstring> is the Fast Channel 1 fast message counter binary value on which to trigger.

TriggerABusBItemSentFastCounterHivalue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:HIVALue command.

Description
  • This command sets or queries the high binary fast message counter value to be used when triggering on a SENT bus signal. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:HIVALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:HIVALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:HIVALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:HIVALue <QString>
- TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:HIVALue?
Info
  • <Qstring> sets the Fast Channel 1 counter binary value.

TriggerABusBItemSentFastCounterQualifier

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:QUALifier command.

Description
  • This command sets or queries the qualifier to be used when triggering on SENT fast packet bus data for the secure format counter. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:QUALifier {EQual|UNEQual|LESSthan|MOREthan|LESSEQual|MOREEQual|INrange|OUTrange}
- TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:QUALifier?
Info
  • EQUal sets the qualifier as Equal.
  • LESSEQual sets the qualifier as Less Than or Equal to.
  • LESSThan sets the qualifier as Less Than.
  • MOREEQual sets the qualifier as More Than or Equal to.
  • MOREThan sets the qualifier as More Than.
  • UNEQual sets the qualifier as Unequal.
  • INrange sets the qualifier to inside a range.
  • OUTrange sets the qualifier to outside a range.

TriggerABusBItemSentFastCounterValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:VALue command.

Description
  • This command sets or queries the binary fast message counter value to be used when triggering on a SENT bus signal. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:VALue <Qstring>
- TRIGger:A:BUS:B<x>:SENT:FAST:COUNTer:VALue?
Info
  • <Qstring> is the Fast Channel 1 fast message counter binary value on which to trigger.

TriggerABusBItemSentFastInvertnibble

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:SENT:FAST:INVERTNIBble command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:FAST:INVERTNIBble? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:INVERTNIBble? query and raise an AssertionError if the returned value does not match value.
Properties
  • .value: The TRIGger:A:BUS:B<x>:SENT:FAST:INVERTNIBble:VALue command.

value property

Return the TRIGger:A:BUS:B<x>:SENT:FAST:INVERTNIBble:VALue command.

Description
  • This command sets or queries the binary fast message inverted nibble value to be used when triggering on a SENT bus signal. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:FAST:INVERTNIBble:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:INVERTNIBble:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:INVERTNIBble:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SENT:FAST:INVERTNIBble:VALue <Qstring>
- TRIGger:A:BUS:B<x>:SENT:FAST:INVERTNIBble:VALue?
Info
  • <Qstring> is the Fast Channel 1 inverted nibble binary value on which to trigger.

TriggerABusBItemSentFastInvertnibbleValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:SENT:FAST:INVERTNIBble:VALue command.

Description
  • This command sets or queries the binary fast message inverted nibble value to be used when triggering on a SENT bus signal. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:FAST:INVERTNIBble:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:INVERTNIBble:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:INVERTNIBble:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SENT:FAST:INVERTNIBble:VALue <Qstring>
- TRIGger:A:BUS:B<x>:SENT:FAST:INVERTNIBble:VALue?
Info
  • <Qstring> is the Fast Channel 1 inverted nibble binary value on which to trigger.

TriggerABusBItemSentFastStatus

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:SENT:FAST:STATus command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:FAST:STATus? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:STATus? query and raise an AssertionError if the returned value does not match value.
Properties
  • .value: The TRIGger:A:BUS:B<x>:SENT:FAST:STATus:VALue command.

value property

Return the TRIGger:A:BUS:B<x>:SENT:FAST:STATus:VALue command.

Description
  • This command sets or queries the binary status value to be used when triggering on a SENT bus signal. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:FAST:STATus:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:STATus:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:STATus:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SENT:FAST:STATus:VALue <Qstring>
- TRIGger:A:BUS:B<x>:SENT:FAST:STATus:VALue?
Info
  • <Qstring> is the binary status value on which to trigger.

TriggerABusBItemSentFastStatusValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:SENT:FAST:STATus:VALue command.

Description
  • This command sets or queries the binary status value to be used when triggering on a SENT bus signal. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:FAST:STATus:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:STATus:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SENT:FAST:STATus:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SENT:FAST:STATus:VALue <Qstring>
- TRIGger:A:BUS:B<x>:SENT:FAST:STATus:VALue?
Info
  • <Qstring> is the binary status value on which to trigger.

TriggerABusBItemSentPause

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:SENT:PAUSE command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:PAUSE? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:PAUSE? query and raise an AssertionError if the returned value does not match value.
Properties
  • .qualifier: The TRIGger:A:BUS:B<x>:SENT:PAUSE:QUALifier command.

qualifier property

Return the TRIGger:A:BUS:B<x>:SENT:PAUSE:QUALifier command.

Description
  • This command sets or queries the qualifier to be used when triggering on SENT pause pulses. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:PAUSE:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:PAUSE:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SENT:PAUSE:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SENT:PAUSE:QUALifier {EQual|UNEQual|LESSthan|MOREthan|LESSEQual|MOREEQual|Inrange|OUTrange}
- TRIGger:A:BUS:B<x>:SENT:PAUSE:QUALifier?
Info
  • EQUal sets the qualifier as Equal.
  • INrange sets the qualifier to in range.
  • LESSEQual sets the qualifier as Less Than or Equal to.
  • LESSThan sets the qualifier as Less Than.
  • MOREEQual sets the qualifier as More Than or Equal to.
  • MOREThan sets the qualifier as More Than.
  • OUTrange sets the qualifier to out of range.
  • UNEQual sets the qualifier as Unequal.

TriggerABusBItemSentPauseQualifier

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:SENT:PAUSE:QUALifier command.

Description
  • This command sets or queries the qualifier to be used when triggering on SENT pause pulses. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:PAUSE:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:PAUSE:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SENT:PAUSE:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SENT:PAUSE:QUALifier {EQual|UNEQual|LESSthan|MOREthan|LESSEQual|MOREEQual|Inrange|OUTrange}
- TRIGger:A:BUS:B<x>:SENT:PAUSE:QUALifier?
Info
  • EQUal sets the qualifier as Equal.
  • INrange sets the qualifier to in range.
  • LESSEQual sets the qualifier as Less Than or Equal to.
  • LESSThan sets the qualifier as Less Than.
  • MOREEQual sets the qualifier as More Than or Equal to.
  • MOREThan sets the qualifier as More Than.
  • OUTrange sets the qualifier to out of range.
  • UNEQual sets the qualifier as Unequal.

TriggerABusBItemSentSlow

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:SENT:SLOW command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:SLOW? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:SLOW? query and raise an AssertionError if the returned value does not match value.
Properties
  • .data: The TRIGger:A:BUS:B<x>:SENT:SLOW:DATA command tree.
  • .identifier: The TRIGger:A:BUS:B<x>:SENT:SLOW:IDentifier command tree.

data property

Return the TRIGger:A:BUS:B<x>:SENT:SLOW:DATA command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:SLOW:DATA? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:SLOW:DATA? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .hivalue: The TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:HIVALue command.
  • .qualifier: The TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:QUALifier command.
  • .value: The TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:VALue command.

identifier property

Return the TRIGger:A:BUS:B<x>:SENT:SLOW:IDentifier command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:SLOW:IDentifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:SLOW:IDentifier? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .value: The TRIGger:A:BUS:B<x>:SENT:SLOW:IDentifier:VALue command.

TriggerABusBItemSentSlowData

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:SENT:SLOW:DATA command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:SLOW:DATA? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:SLOW:DATA? query and raise an AssertionError if the returned value does not match value.
Properties
  • .hivalue: The TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:HIVALue command.
  • .qualifier: The TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:QUALifier command.
  • .value: The TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:VALue command.

hivalue property

Return the TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:HIVALue command.

Description
  • This command sets or queries the high binary Slow channel data value to use when triggering on a SENT bus signal. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:HIVALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:HIVALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:HIVALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:HIVALue <QString>
- TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:HIVALue?
Info
  • <Qstring> sets the binary Slow channel data value.

qualifier property

Return the TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:QUALifier command.

Description
  • This command sets or queries the binary identifier value to use when triggering on a SENT bus signal. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:QUALifier {EQual|UNEQual|LESSthan|MOREthan|LESSEQual|MOREEQual|INRange|OUTRange}
- TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:QUALifier?
Info
  • EQUal specifies the qualifier as Equal.
  • UNEQual specifies the qualifier as Not Equal to.
  • LESSthan specifies the qualifier as Less Than.
  • MOREthan specifies the qualifier as More Than.
  • LESSEQual specifies the qualifier as Less Than or Equal to.
  • MOREEQual specifies the qualifier as More Than or Equal to.
  • INRange sets the qualifier to inside a range.
  • OUTRange sets the qualifier to outside a range.

value property

Return the TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:VALue command.

Description
  • This command sets or queries the binary slow channel value to use when triggering on a SENT bus signal. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:VALue <Qstring>
- TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:VALue?
Info
  • <Qstring> is the binary slow channel data value.

TriggerABusBItemSentSlowDataHivalue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:HIVALue command.

Description
  • This command sets or queries the high binary Slow channel data value to use when triggering on a SENT bus signal. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:HIVALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:HIVALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:HIVALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:HIVALue <QString>
- TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:HIVALue?
Info
  • <Qstring> sets the binary Slow channel data value.

TriggerABusBItemSentSlowDataQualifier

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:QUALifier command.

Description
  • This command sets or queries the binary identifier value to use when triggering on a SENT bus signal. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:QUALifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:QUALifier? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:QUALifier value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:QUALifier {EQual|UNEQual|LESSthan|MOREthan|LESSEQual|MOREEQual|INRange|OUTRange}
- TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:QUALifier?
Info
  • EQUal specifies the qualifier as Equal.
  • UNEQual specifies the qualifier as Not Equal to.
  • LESSthan specifies the qualifier as Less Than.
  • MOREthan specifies the qualifier as More Than.
  • LESSEQual specifies the qualifier as Less Than or Equal to.
  • MOREEQual specifies the qualifier as More Than or Equal to.
  • INRange sets the qualifier to inside a range.
  • OUTRange sets the qualifier to outside a range.

TriggerABusBItemSentSlowDataValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:VALue command.

Description
  • This command sets or queries the binary slow channel value to use when triggering on a SENT bus signal. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:VALue <Qstring>
- TRIGger:A:BUS:B<x>:SENT:SLOW:DATA:VALue?
Info
  • <Qstring> is the binary slow channel data value.

TriggerABusBItemSentSlowIdentifier

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:SENT:SLOW:IDentifier command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:SLOW:IDentifier? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:SLOW:IDentifier? query and raise an AssertionError if the returned value does not match value.
Properties
  • .value: The TRIGger:A:BUS:B<x>:SENT:SLOW:IDentifier:VALue command.

value property

Return the TRIGger:A:BUS:B<x>:SENT:SLOW:IDentifier:VALue command.

Description
  • This command sets or queries the qualifier to use when triggering on SENT slow packet bus data. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:SLOW:IDentifier:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:SLOW:IDentifier:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SENT:SLOW:IDentifier:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SENT:SLOW:IDentifier:VALue <Qstring>
- TRIGger:A:BUS:B<x>:SENT:SLOW:IDentifier:VALue?
Info
  • <Qstring> is the binary identifier value.

TriggerABusBItemSentSlowIdentifierValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:SENT:SLOW:IDentifier:VALue command.

Description
  • This command sets or queries the qualifier to use when triggering on SENT slow packet bus data. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SENT:SLOW:IDentifier:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SENT:SLOW:IDentifier:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SENT:SLOW:IDentifier:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SENT:SLOW:IDentifier:VALue <Qstring>
- TRIGger:A:BUS:B<x>:SENT:SLOW:IDentifier:VALue?
Info
  • <Qstring> is the binary identifier value.

TriggerABusBItemSpi

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:SPI command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI? query and raise an AssertionError if the returned value does not match value.
Properties
  • .condition: The TRIGger:A:BUS:B<x>:SPI:CONDition command.
  • .data: The TRIGger:A:BUS:B<x>:SPI:DATa command tree.

condition property

Return the TRIGger:A:BUS:B<x>:SPI:CONDition command.

Description
  • This command specifies the trigger condition for a SPI trigger. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SPI:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SPI:CONDition {SS|STARTofframe|DATa}
- TRIGger:A:BUS:B<x>:SPI:CONDition?
Info
  • SS specifies the Slave Selection condition.
  • STARTofframe is applicable when BUS:B<x>:SPI:FRAMING is set to IDLEtime. When the trigger condition is set to STARTofframe, the instrument triggers on the first SPI clock after an idle time when there are no clocks.
  • DATa sets the trigger condition to Master-In Slave-Out and Master-Out Slave-In.

data property

Return the TRIGger:A:BUS:B<x>:SPI:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .size: The TRIGger:A:BUS:B<x>:SPI:DATa:SIZe command.
  • .value: The TRIGger:A:BUS:B<x>:SPI:DATa:VALue command.

TriggerABusBItemSpiCondition

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:SPI:CONDition command.

Description
  • This command specifies the trigger condition for a SPI trigger. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:CONDition? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:CONDition? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SPI:CONDition value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SPI:CONDition {SS|STARTofframe|DATa}
- TRIGger:A:BUS:B<x>:SPI:CONDition?
Info
  • SS specifies the Slave Selection condition.
  • STARTofframe is applicable when BUS:B<x>:SPI:FRAMING is set to IDLEtime. When the trigger condition is set to STARTofframe, the instrument triggers on the first SPI clock after an idle time when there are no clocks.
  • DATa sets the trigger condition to Master-In Slave-Out and Master-Out Slave-In.

TriggerABusBItemSpiData

Bases: SCPICmdRead

The TRIGger:A:BUS:B<x>:SPI:DATa command tree.

Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa? query and raise an AssertionError if the returned value does not match value.
Properties
  • .size: The TRIGger:A:BUS:B<x>:SPI:DATa:SIZe command.
  • .value: The TRIGger:A:BUS:B<x>:SPI:DATa:VALue command.

size property

Return the TRIGger:A:BUS:B<x>:SPI:DATa:SIZe command.

Description
  • This command specifies the length of the data string to be used for a SPI trigger if the trigger condition is DATa. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SPI:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:SPI:DATa:SIZe?
Info
  • <NR1> is the length of the data string in bytes.

value property

Return the TRIGger:A:BUS:B<x>:SPI:DATa:VALue command.

Description
  • This command specifies the binary data string used for SPI triggering if the trigger condition is DATA. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SPI:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:SPI:DATa:VALue?
Info
  • <QString> specifies the data value in the specified valid format. The valid characters are 0, 1, and X for binary format.

TriggerABusBItemSpiDataSize

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:SPI:DATa:SIZe command.

Description
  • This command specifies the length of the data string to be used for a SPI trigger if the trigger condition is DATa. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:SIZe? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:SIZe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:SIZe value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SPI:DATa:SIZe <NR1>
- TRIGger:A:BUS:B<x>:SPI:DATa:SIZe?
Info
  • <NR1> is the length of the data string in bytes.

TriggerABusBItemSpiDataValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:B<x>:SPI:DATa:VALue command.

Description
  • This command specifies the binary data string used for SPI triggering if the trigger condition is DATA. B is the specified bus number.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:B<x>:SPI:DATa:VALue? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:B<x>:SPI:DATa:VALue value command.
SCPI Syntax
- TRIGger:A:BUS:B<x>:SPI:DATa:VALue <QString>
- TRIGger:A:BUS:B<x>:SPI:DATa:VALue?
Info
  • <QString> specifies the data value in the specified valid format. The valid characters are 0, 1, and X for binary format.

TriggerABusSource

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:BUS:SOUrce command.

Description
  • This command sets or queries the source bus for a bus trigger.
Usage
  • Using the .query() method will send the TRIGger:A:BUS:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:BUS:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:BUS:SOUrce value command.
SCPI Syntax
- TRIGger:A:BUS:SOUrce B<x>
- TRIGger:A:BUS:SOUrce?
Info
  • B<x> sets the selected source to the bus.

TriggerAEdge

Bases: SCPICmdRead

The TRIGger:A:EDGE command tree.

Usage
  • Using the .query() method will send the TRIGger:A:EDGE? query.
  • Using the .verify(value) method will send the TRIGger:A:EDGE? query and raise an AssertionError if the returned value does not match value.
Properties
  • .coupling: The TRIGger:A:EDGE:COUPling command.
  • .slope: The TRIGger:A:EDGE:SLOpe command.
  • .source: The TRIGger:A:EDGE:SOUrce command.

coupling property

Return the TRIGger:A:EDGE:COUPling command.

Description
  • This command sets or queries the type of coupling for the edge trigger. This command is equivalent to selecting Edge from the Trigger Type drop-down in the Trigger setup context menu, and choosing from the Coupling drop-down list.
Usage
  • Using the .query() method will send the TRIGger:A:EDGE:COUPling? query.
  • Using the .verify(value) method will send the TRIGger:A:EDGE:COUPling? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:EDGE:COUPling value command.
SCPI Syntax
- TRIGger:A:EDGE:COUPling {DC|HFRej|LFRej|NOISErej}
- TRIGger:A:EDGE:COUPling?
Info
  • DC selects DC trigger coupling, which passes all input signals to the trigger circuitry.
  • HFRej coupling attenuates signals above 50 kHz before passing the signals to the trigger circuitry.
  • LFRej coupling attenuates signals below 80 kHz before passing the signals to the trigger circuitry.
  • NOISErej coupling provides stable triggering by increasing the trigger hysteresis. Increased hysteresis reduces the trigger sensitivity to noise but can require greater trigger signal amplitude.

slope property

Return the TRIGger:A:EDGE:SLOpe command.

Description
  • This command sets or queries the slope for the edge trigger. This command is equivalent to selecting Edge from the Trigger Type drop-down in the Trigger setup context menu, and then choosing the desired Slope. This command is also equivalent to pressing the front-panel Slope button.
Usage
  • Using the .query() method will send the TRIGger:A:EDGE:SLOpe? query.
  • Using the .verify(value) method will send the TRIGger:A:EDGE:SLOpe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:EDGE:SLOpe value command.
SCPI Syntax
- TRIGger:A:EDGE:SLOpe {RISe|FALL|EITher}
- TRIGger:A:EDGE:SLOpe?
Info
  • RISe specifies to trigger on the rising or positive edge of a signal.
  • FALL specifies to trigger on the falling or negative edge of a signal.
  • EITHER specifies to trigger on either the rising or falling edge of a signal.

source property

Return the TRIGger:A:EDGE:SOUrce command.

Description
  • This command sets or queries the source for the edge trigger. For instruments that have an Auxiliary Input, AUXiliary can be selected as trigger source.
Usage
  • Using the .query() method will send the TRIGger:A:EDGE:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:EDGE:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:EDGE:SOUrce value command.
SCPI Syntax
- TRIGger:A:EDGE:SOUrce {CH<x>|DCH<x>_D<x>|INTernal|AUXiliary}
- TRIGger:A:EDGE:SOUrce?
Info
  • CH<x> specifies an analog channel as the edge trigger source.
  • DCH<x>_D<x> specifies a digital channel as the edge trigger source. The supported digital channel value is 1. The supported digital bit values are 0 to 15.
  • INTernal specifies a internal edge trigger source.
  • AUXiliary specifies the Auxiliary Input.

TriggerAEdgeCoupling

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:EDGE:COUPling command.

Description
  • This command sets or queries the type of coupling for the edge trigger. This command is equivalent to selecting Edge from the Trigger Type drop-down in the Trigger setup context menu, and choosing from the Coupling drop-down list.
Usage
  • Using the .query() method will send the TRIGger:A:EDGE:COUPling? query.
  • Using the .verify(value) method will send the TRIGger:A:EDGE:COUPling? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:EDGE:COUPling value command.
SCPI Syntax
- TRIGger:A:EDGE:COUPling {DC|HFRej|LFRej|NOISErej}
- TRIGger:A:EDGE:COUPling?
Info
  • DC selects DC trigger coupling, which passes all input signals to the trigger circuitry.
  • HFRej coupling attenuates signals above 50 kHz before passing the signals to the trigger circuitry.
  • LFRej coupling attenuates signals below 80 kHz before passing the signals to the trigger circuitry.
  • NOISErej coupling provides stable triggering by increasing the trigger hysteresis. Increased hysteresis reduces the trigger sensitivity to noise but can require greater trigger signal amplitude.

TriggerAEdgeSlope

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:EDGE:SLOpe command.

Description
  • This command sets or queries the slope for the edge trigger. This command is equivalent to selecting Edge from the Trigger Type drop-down in the Trigger setup context menu, and then choosing the desired Slope. This command is also equivalent to pressing the front-panel Slope button.
Usage
  • Using the .query() method will send the TRIGger:A:EDGE:SLOpe? query.
  • Using the .verify(value) method will send the TRIGger:A:EDGE:SLOpe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:EDGE:SLOpe value command.
SCPI Syntax
- TRIGger:A:EDGE:SLOpe {RISe|FALL|EITher}
- TRIGger:A:EDGE:SLOpe?
Info
  • RISe specifies to trigger on the rising or positive edge of a signal.
  • FALL specifies to trigger on the falling or negative edge of a signal.
  • EITHER specifies to trigger on either the rising or falling edge of a signal.

TriggerAEdgeSource

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:EDGE:SOUrce command.

Description
  • This command sets or queries the source for the edge trigger. For instruments that have an Auxiliary Input, AUXiliary can be selected as trigger source.
Usage
  • Using the .query() method will send the TRIGger:A:EDGE:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:EDGE:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:EDGE:SOUrce value command.
SCPI Syntax
- TRIGger:A:EDGE:SOUrce {CH<x>|DCH<x>_D<x>|INTernal|AUXiliary}
- TRIGger:A:EDGE:SOUrce?
Info
  • CH<x> specifies an analog channel as the edge trigger source.
  • DCH<x>_D<x> specifies a digital channel as the edge trigger source. The supported digital channel value is 1. The supported digital bit values are 0 to 15.
  • INTernal specifies a internal edge trigger source.
  • AUXiliary specifies the Auxiliary Input.

TriggerAHoldoff

Bases: SCPICmdRead

The TRIGger:A:HOLDoff command tree.

Usage
  • Using the .query() method will send the TRIGger:A:HOLDoff? query.
  • Using the .verify(value) method will send the TRIGger:A:HOLDoff? query and raise an AssertionError if the returned value does not match value.
Properties
  • .time: The TRIGger:A:HOLDoff:TIMe command.

time property

Return the TRIGger:A:HOLDoff:TIMe command.

Description
  • This command sets or queries the A trigger holdoff time. This command is equivalent to selecting Mode & Holdoff from the Trig menu, selecting Time, and then setting the desired Holdoff Time.
Usage
  • Using the .query() method will send the TRIGger:A:HOLDoff:TIMe? query.
  • Using the .verify(value) method will send the TRIGger:A:HOLDoff:TIMe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:HOLDoff:TIMe value command.
SCPI Syntax
- TRIGger:A:HOLDoff:TIMe <NR3>
- TRIGger:A:HOLDoff:TIMe?
Info
  • <NR3> specifies the holdoff time in seconds. The range is from 0 seconds through 10 seconds.

TriggerAHoldoffTime

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:HOLDoff:TIMe command.

Description
  • This command sets or queries the A trigger holdoff time. This command is equivalent to selecting Mode & Holdoff from the Trig menu, selecting Time, and then setting the desired Holdoff Time.
Usage
  • Using the .query() method will send the TRIGger:A:HOLDoff:TIMe? query.
  • Using the .verify(value) method will send the TRIGger:A:HOLDoff:TIMe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:HOLDoff:TIMe value command.
SCPI Syntax
- TRIGger:A:HOLDoff:TIMe <NR3>
- TRIGger:A:HOLDoff:TIMe?
Info
  • <NR3> specifies the holdoff time in seconds. The range is from 0 seconds through 10 seconds.

TriggerALevel

Bases: SCPICmdRead

The TRIGger:A:LEVel command tree.

Usage
  • Using the .query() method will send the TRIGger:A:LEVel? query.
  • Using the .verify(value) method will send the TRIGger:A:LEVel? query and raise an AssertionError if the returned value does not match value.
Properties
  • .ch: The TRIGger:A:LEVel:CH<x> command.

ch property

Return the TRIGger:A:LEVel:CH<x> command.

Description
  • This command sets or queries the CH trigger level for an Edge, Pulse Width, Runt or Rise/Fall (Transition and Slew Rate) trigger when triggering on an analog channel waveform. Each channel can have an independent trigger level. The is the channel number.
Usage
  • Using the .query() method will send the TRIGger:A:LEVel:CH<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LEVel:CH<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LEVel:CH<x> value command.
SCPI Syntax
- TRIGger:A:LEVel:CH<x> <NR3>
- TRIGger:A:LEVel:CH<x>?
Info
  • <NR3> specifies the trigger level in user units (usually volts).

TriggerALevelChannel

Bases: ValidatedChannel, SCPICmdWrite, SCPICmdRead

The TRIGger:A:LEVel:CH<x> command.

Description
  • This command sets or queries the CH trigger level for an Edge, Pulse Width, Runt or Rise/Fall (Transition and Slew Rate) trigger when triggering on an analog channel waveform. Each channel can have an independent trigger level. The is the channel number.
Usage
  • Using the .query() method will send the TRIGger:A:LEVel:CH<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LEVel:CH<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LEVel:CH<x> value command.
SCPI Syntax
- TRIGger:A:LEVel:CH<x> <NR3>
- TRIGger:A:LEVel:CH<x>?
Info
  • <NR3> specifies the trigger level in user units (usually volts).

TriggerALogic

Bases: SCPICmdRead

The TRIGger:A:LOGIc command tree.

Usage
  • Using the .query() method will send the TRIGger:A:LOGIc? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc? query and raise an AssertionError if the returned value does not match value.
Properties
  • .deltatime: The TRIGger:A:LOGIc:DELTatime command.
  • .function: The TRIGger:A:LOGIc:FUNCtion command.
  • .input: The TRIGger:A:LOGIc:INPut command tree.
  • .polarity: The TRIGger:A:LOGIc:POLarity command.
  • .useclockedge: The TRIGger:A:LOGIc:USECLockedge command.
  • .when: The TRIGger:A:LOGIc:WHEn command.

deltatime property

Return the TRIGger:A:LOGIc:DELTatime command.

Description
  • This command specifies or queries the Logic trigger delta time value. The time value is used as part of the Logic trigger condition to determine if the duration of a logic pattern meets the specified time constraints.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:DELTatime? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:DELTatime? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:DELTatime value command.
SCPI Syntax
- TRIGger:A:LOGIc:DELTatime <NR3>
- TRIGger:A:LOGIc:DELTatime?
Info
  • <NR3> the Logic trigger delta time value.

function property

Return the TRIGger:A:LOGIc:FUNCtion command.

Description
  • This command sets or queries the logical combination of the input channels for logic triggers. This command is equivalent to selecting Logic for the Trigger Type, and setting or viewing the Define Logic.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:FUNCtion? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:FUNCtion? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:FUNCtion value command.
SCPI Syntax
- TRIGger:A:LOGIc:FUNCtion {AND|NANd|NOR|OR}
- TRIGger:A:LOGIc:FUNCtion?
Info
  • AND specifies to trigger if all conditions are true.
  • NANd specifies to trigger if any of the conditions are false.
  • NOR specifies to trigger if all conditions are false.
  • OR specifies to trigger if any of the conditions are true.

input property

Return the TRIGger:A:LOGIc:INPut command tree.

Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:INPut? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:INPut? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .clock: The TRIGger:A:LOGIc:INPut:CLOCk command tree.

polarity property

Return the TRIGger:A:LOGIc:POLarity command.

Description
  • This command sets or queries the polarity for the clock channel when Use Clock Edge is set to Yes for Logic trigger type.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:POLarity? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:POLarity? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:POLarity value command.
SCPI Syntax
- TRIGger:A:LOGIc:POLarity {POSitive|NEGative|EITher}
- TRIGger:A:LOGIc:POLarity?
Info
  • NEGative specifies negative polarity.
  • POSITIVe specifies positive polarity.
  • EITher specifies either polarity.

useclockedge property

Return the TRIGger:A:LOGIc:USECLockedge command.

Description
  • This command specifies whether or not Logic trigger type uses clock source.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:USECLockedge? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:USECLockedge? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:USECLockedge value command.
SCPI Syntax
- TRIGger:A:LOGIc:USECLockedge {OFF|ON|0|1|<NR1>}
- TRIGger:A:LOGIc:USECLockedge?
Info
  • ON specifies that logic trigger type uses clock source.
  • 1 specifies that logic trigger type uses clock source.
  • OFF specifies that logic trigger type does not use clock source.
  • 0 specifies that logic trigger type does not use clock source.
  • <NR1> = 0 specifies that logic trigger type does not use clock source; any other value uses clock source.

when property

Return the TRIGger:A:LOGIc:WHEn command.

Description
  • This command sets or queries the condition for generating an A or B logic trigger with respect to the defined input pattern. This command is equivalent to selecting Logic for Trigger Type, Use Clock Edge to No, and choosing a trigger condition from the Logic Pattern drop-down list.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:WHEn? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:WHEn? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:WHEn value command.
SCPI Syntax
- TRIGger:A:LOGIc:WHEn {TRUe|FALSe|MOREThan|LESSThan|EQual|UNEQual}
- TRIGger:A:LOGIc:WHEn?
Info
  • TRUe triggers on an input pattern that is true.
  • FALSe triggers on an input pattern that is false.
  • MOREthan triggers on an input pattern that is true for a time period greater than a user defined Time Limit (DELTatime) value.
  • LESSthan triggers on an input pattern that is true for a time period less than a user defined Time Limit (DELTatime) value.
  • EQual triggers on an input pattern that is true for a time period equal to a user defined Time Limit (DELTatime) value.
  • UNEQual triggers on an input pattern that is true for a time period not equal to a user defined Time Limit (DELTatime) value.

TriggerALogicDeltatime

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOGIc:DELTatime command.

Description
  • This command specifies or queries the Logic trigger delta time value. The time value is used as part of the Logic trigger condition to determine if the duration of a logic pattern meets the specified time constraints.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:DELTatime? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:DELTatime? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:DELTatime value command.
SCPI Syntax
- TRIGger:A:LOGIc:DELTatime <NR3>
- TRIGger:A:LOGIc:DELTatime?
Info
  • <NR3> the Logic trigger delta time value.

TriggerALogicFunction

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOGIc:FUNCtion command.

Description
  • This command sets or queries the logical combination of the input channels for logic triggers. This command is equivalent to selecting Logic for the Trigger Type, and setting or viewing the Define Logic.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:FUNCtion? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:FUNCtion? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:FUNCtion value command.
SCPI Syntax
- TRIGger:A:LOGIc:FUNCtion {AND|NANd|NOR|OR}
- TRIGger:A:LOGIc:FUNCtion?
Info
  • AND specifies to trigger if all conditions are true.
  • NANd specifies to trigger if any of the conditions are false.
  • NOR specifies to trigger if all conditions are false.
  • OR specifies to trigger if any of the conditions are true.

TriggerALogicInput

Bases: SCPICmdRead

The TRIGger:A:LOGIc:INPut command tree.

Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:INPut? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:INPut? query and raise an AssertionError if the returned value does not match value.
Properties
  • .clock: The TRIGger:A:LOGIc:INPut:CLOCk command tree.

clock property

Return the TRIGger:A:LOGIc:INPut:CLOCk command tree.

Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:INPut:CLOCk? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:INPut:CLOCk? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .source: The TRIGger:A:LOGIc:INPut:CLOCk:SOUrce command.

TriggerALogicInputClock

Bases: SCPICmdRead

The TRIGger:A:LOGIc:INPut:CLOCk command tree.

Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:INPut:CLOCk? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:INPut:CLOCk? query and raise an AssertionError if the returned value does not match value.
Properties
  • .source: The TRIGger:A:LOGIc:INPut:CLOCk:SOUrce command.

source property

Return the TRIGger:A:LOGIc:INPut:CLOCk:SOUrce command.

Description
  • This command specifies the channel to use as the clock source for logic trigger.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:INPut:CLOCk:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:INPut:CLOCk:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:INPut:CLOCk:SOUrce value command.
SCPI Syntax
- TRIGger:A:LOGIc:INPut:CLOCk:SOUrce {CH<x>|DCH<x>_D<x>}
- TRIGger:A:LOGIc:INPut:CLOCk:SOUrce?
Info
  • CH<x> specifies an analog channel as the clock source. Number of channels depends on instrument configuration.
  • DCH<x>_D<x> specifies a digital channel as the clock source. The supported digital channel value is 1. The supported digital bit values are 0 to 15.

TriggerALogicInputClockSource

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOGIc:INPut:CLOCk:SOUrce command.

Description
  • This command specifies the channel to use as the clock source for logic trigger.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:INPut:CLOCk:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:INPut:CLOCk:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:INPut:CLOCk:SOUrce value command.
SCPI Syntax
- TRIGger:A:LOGIc:INPut:CLOCk:SOUrce {CH<x>|DCH<x>_D<x>}
- TRIGger:A:LOGIc:INPut:CLOCk:SOUrce?
Info
  • CH<x> specifies an analog channel as the clock source. Number of channels depends on instrument configuration.
  • DCH<x>_D<x> specifies a digital channel as the clock source. The supported digital channel value is 1. The supported digital bit values are 0 to 15.

TriggerALogicPolarity

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOGIc:POLarity command.

Description
  • This command sets or queries the polarity for the clock channel when Use Clock Edge is set to Yes for Logic trigger type.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:POLarity? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:POLarity? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:POLarity value command.
SCPI Syntax
- TRIGger:A:LOGIc:POLarity {POSitive|NEGative|EITher}
- TRIGger:A:LOGIc:POLarity?
Info
  • NEGative specifies negative polarity.
  • POSITIVe specifies positive polarity.
  • EITher specifies either polarity.

TriggerALogicUseclockedge

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOGIc:USECLockedge command.

Description
  • This command specifies whether or not Logic trigger type uses clock source.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:USECLockedge? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:USECLockedge? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:USECLockedge value command.
SCPI Syntax
- TRIGger:A:LOGIc:USECLockedge {OFF|ON|0|1|<NR1>}
- TRIGger:A:LOGIc:USECLockedge?
Info
  • ON specifies that logic trigger type uses clock source.
  • 1 specifies that logic trigger type uses clock source.
  • OFF specifies that logic trigger type does not use clock source.
  • 0 specifies that logic trigger type does not use clock source.
  • <NR1> = 0 specifies that logic trigger type does not use clock source; any other value uses clock source.

TriggerALogicWhen

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOGIc:WHEn command.

Description
  • This command sets or queries the condition for generating an A or B logic trigger with respect to the defined input pattern. This command is equivalent to selecting Logic for Trigger Type, Use Clock Edge to No, and choosing a trigger condition from the Logic Pattern drop-down list.
Usage
  • Using the .query() method will send the TRIGger:A:LOGIc:WHEn? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGIc:WHEn? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGIc:WHEn value command.
SCPI Syntax
- TRIGger:A:LOGIc:WHEn {TRUe|FALSe|MOREThan|LESSThan|EQual|UNEQual}
- TRIGger:A:LOGIc:WHEn?
Info
  • TRUe triggers on an input pattern that is true.
  • FALSe triggers on an input pattern that is false.
  • MOREthan triggers on an input pattern that is true for a time period greater than a user defined Time Limit (DELTatime) value.
  • LESSthan triggers on an input pattern that is true for a time period less than a user defined Time Limit (DELTatime) value.
  • EQual triggers on an input pattern that is true for a time period equal to a user defined Time Limit (DELTatime) value.
  • UNEQual triggers on an input pattern that is true for a time period not equal to a user defined Time Limit (DELTatime) value.

TriggerALogicpattern

Bases: SCPICmdRead

The TRIGger:A:LOGICPattern command tree.

Usage
  • Using the .query() method will send the TRIGger:A:LOGICPattern? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGICPattern? query and raise an AssertionError if the returned value does not match value.
Properties
  • .ch: The TRIGger:A:LOGICPattern:CH<x> command.
  • .dch: The TRIGger:A:LOGICPattern:DCH<x> command tree.

ch property

Return the TRIGger:A:LOGICPattern:CH<x> command.

Description
  • This command sets or queries the Logic Pattern for the specified channel. This command is used along with the Define Logic choice (LOGIc:FUNCtion) to determine when the logic trigger occurs.
Usage
  • Using the .query() method will send the TRIGger:A:LOGICPattern:CH<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGICPattern:CH<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGICPattern:CH<x> value command.
SCPI Syntax
- TRIGger:A:LOGICPattern:CH<x> {HIGH|LOW|X}
- TRIGger:A:LOGICPattern:CH<x>?
Info
  • CH<x> specifies the channel.
  • HIGH specifies triggering when the pattern is high.
  • LOW specifies triggering when the pattern is low.
  • X specifies triggering when the pattern is high or low.

dch property

Return the TRIGger:A:LOGICPattern:DCH<x> command tree.

Usage
  • Using the .query() method will send the TRIGger:A:LOGICPattern:DCH<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGICPattern:DCH<x>? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .d: The TRIGger:A:LOGICPattern:DCH<x>_D<x> command.

TriggerALogicpatternChannel

Bases: ValidatedChannel, SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOGICPattern:CH<x> command.

Description
  • This command sets or queries the Logic Pattern for the specified channel. This command is used along with the Define Logic choice (LOGIc:FUNCtion) to determine when the logic trigger occurs.
Usage
  • Using the .query() method will send the TRIGger:A:LOGICPattern:CH<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGICPattern:CH<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGICPattern:CH<x> value command.
SCPI Syntax
- TRIGger:A:LOGICPattern:CH<x> {HIGH|LOW|X}
- TRIGger:A:LOGICPattern:CH<x>?
Info
  • CH<x> specifies the channel.
  • HIGH specifies triggering when the pattern is high.
  • LOW specifies triggering when the pattern is low.
  • X specifies triggering when the pattern is high or low.

TriggerALogicpatternDchItem

Bases: ValidatedDynamicNumberCmd, SCPICmdRead

The TRIGger:A:LOGICPattern:DCH<x> command tree.

Usage
  • Using the .query() method will send the TRIGger:A:LOGICPattern:DCH<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGICPattern:DCH<x>? query and raise an AssertionError if the returned value does not match value.
Properties
  • .d: The TRIGger:A:LOGICPattern:DCH<x>_D<x> command.

d property

Return the TRIGger:A:LOGICPattern:DCH<x>_D<x> command.

Description
  • This command sets or queries the Logic Pattern for the specified digital channel. This command is used along with the Define Logic choice (LOGIc:FUNCtion) to determine when the logic trigger occurs.
Usage
  • Using the .query() method will send the TRIGger:A:LOGICPattern:DCH<x>_D<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGICPattern:DCH<x>_D<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGICPattern:DCH<x>_D<x> value command.
SCPI Syntax
- TRIGger:A:LOGICPattern:DCH<x>_D<x> {HIGH|LOW|X}
- TRIGger:A:LOGICPattern:DCH<x>_D<x>?
Info
  • DCH<x>_D<x> specifies the digital channel. The supported digital channel value is 1. The supported digital bits values are 0 to 15.
  • HIGH specifies triggering when the pattern is high.
  • LOW specifies triggering when the pattern is low.
  • X specifies triggering when the pattern is high or low.

TriggerALogicpatternDchItemDigitalBit

Bases: ValidatedDigitalBit, SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOGICPattern:DCH<x>_D<x> command.

Description
  • This command sets or queries the Logic Pattern for the specified digital channel. This command is used along with the Define Logic choice (LOGIc:FUNCtion) to determine when the logic trigger occurs.
Usage
  • Using the .query() method will send the TRIGger:A:LOGICPattern:DCH<x>_D<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LOGICPattern:DCH<x>_D<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOGICPattern:DCH<x>_D<x> value command.
SCPI Syntax
- TRIGger:A:LOGICPattern:DCH<x>_D<x> {HIGH|LOW|X}
- TRIGger:A:LOGICPattern:DCH<x>_D<x>?
Info
  • DCH<x>_D<x> specifies the digital channel. The supported digital channel value is 1. The supported digital bits values are 0 to 15.
  • HIGH specifies triggering when the pattern is high.
  • LOW specifies triggering when the pattern is low.
  • X specifies triggering when the pattern is high or low.

TriggerALowerthreshold

Bases: SCPICmdRead

The TRIGger:A:LOWerthreshold command tree.

Usage
  • Using the .query() method will send the TRIGger:A:LOWerthreshold? query.
  • Using the .verify(value) method will send the TRIGger:A:LOWerthreshold? query and raise an AssertionError if the returned value does not match value.
Properties
  • .ch: The TRIGger:A:LOWerthreshold:CH<x> command.

ch property

Return the TRIGger:A:LOWerthreshold:CH<x> command.

Description
  • This command sets or queries the A or B lower trigger level threshold for the channel, specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:LOWerthreshold:CH<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LOWerthreshold:CH<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOWerthreshold:CH<x> value command.
SCPI Syntax
- TRIGger:A:LOWerthreshold:CH<x> <NR3>
- TRIGger:A:LOWerthreshold:CH<x>?
Info
  • <NR3> specifies the threshold voltage in user units.

TriggerALowerthresholdChannel

Bases: ValidatedChannel, SCPICmdWrite, SCPICmdRead

The TRIGger:A:LOWerthreshold:CH<x> command.

Description
  • This command sets or queries the A or B lower trigger level threshold for the channel, specified by x.
Usage
  • Using the .query() method will send the TRIGger:A:LOWerthreshold:CH<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:LOWerthreshold:CH<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:LOWerthreshold:CH<x> value command.
SCPI Syntax
- TRIGger:A:LOWerthreshold:CH<x> <NR3>
- TRIGger:A:LOWerthreshold:CH<x>?
Info
  • <NR3> specifies the threshold voltage in user units.

TriggerAMode

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:MODe command.

Description
  • This command sets or queries the A trigger mode. This command is equivalent to pushing the Mode button on the front panel.
Usage
  • Using the .query() method will send the TRIGger:A:MODe? query.
  • Using the .verify(value) method will send the TRIGger:A:MODe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:MODe value command.
SCPI Syntax
- TRIGger:A:MODe {AUTO|NORMal}
- TRIGger:A:MODe?
Info
  • AUTO generates a trigger if one is not detected within a specified time period.
  • NORMal waits for a valid trigger event.

TriggerAPulsewidth

Bases: SCPICmdRead

The TRIGger:A:PULSEWidth command tree.

Usage
  • Using the .query() method will send the TRIGger:A:PULSEWidth? query.
  • Using the .verify(value) method will send the TRIGger:A:PULSEWidth? query and raise an AssertionError if the returned value does not match value.
Properties
  • .highlimit: The TRIGger:A:PULSEWidth:HIGHLimit command.
  • .lowlimit: The TRIGger:A:PULSEWidth:LOWLimit command.
  • .polarity: The TRIGger:A:PULSEWidth:POLarity command.
  • .source: The TRIGger:A:PULSEWidth:SOUrce command.
  • .when: The TRIGger:A:PULSEWidth:WHEn command.

highlimit property

Return the TRIGger:A:PULSEWidth:HIGHLimit command.

Description
  • This command specifies the upper limit to use, in seconds, when triggering on detection of a pulse whose duration is inside or outside a range of two values. (Use TRIGGER:A:PULSEWIDTH:LOWLIMIT to specify the lower value of the range.)
Usage
  • Using the .query() method will send the TRIGger:A:PULSEWidth:HIGHLimit? query.
  • Using the .verify(value) method will send the TRIGger:A:PULSEWidth:HIGHLimit? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:PULSEWidth:HIGHLimit value command.
SCPI Syntax
- TRIGger:A:PULSEWidth:HIGHLimit <NR3>
- TRIGger:A:PULSEWidth:HIGHLimit?
Info
  • <NR3> is a floating point number that represents the higher value of the range.

lowlimit property

Return the TRIGger:A:PULSEWidth:LOWLimit command.

Description
  • This command specifies the lower limit to use, in seconds, when triggering on detection of a pulse whose duration is inside or outside a range of two values. (Use TRIGGER:A:PULSEWIDTH:HIGHLIMIT to specify the upper limit of the range.) This command also specifies the single limit to use, in seconds, when triggering on detection of a pulse whose duration is less than, greater than, equal to, or not equal to this time limit.
Usage
  • Using the .query() method will send the TRIGger:A:PULSEWidth:LOWLimit? query.
  • Using the .verify(value) method will send the TRIGger:A:PULSEWidth:LOWLimit? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:PULSEWidth:LOWLimit value command.
SCPI Syntax
- TRIGger:A:PULSEWidth:LOWLimit <NR3>
- TRIGger:A:PULSEWidth:LOWLimit?
Info
  • <NR3> is a floating point number that represents the lower value of the range.

polarity property

Return the TRIGger:A:PULSEWidth:POLarity command.

Description
  • This command specifies the polarity for a pulse width trigger.
Usage
  • Using the .query() method will send the TRIGger:A:PULSEWidth:POLarity? query.
  • Using the .verify(value) method will send the TRIGger:A:PULSEWidth:POLarity? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:PULSEWidth:POLarity value command.
SCPI Syntax
- TRIGger:A:PULSEWidth:POLarity {NEGative|POSitive}
- TRIGger:A:PULSEWidth:POLarity?
Info
  • NEGative specifies a negative pulse.
  • POSitive specifies a positive pulse.

source property

Return the TRIGger:A:PULSEWidth:SOUrce command.

Description
  • This command specifies the source waveform for a pulse width trigger.
Usage
  • Using the .query() method will send the TRIGger:A:PULSEWidth:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:PULSEWidth:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:PULSEWidth:SOUrce value command.
SCPI Syntax
- TRIGger:A:PULSEWidth:SOUrce {CH<x>|DCH<x>_D<x>}
- TRIGger:A:PULSEWidth:SOUrce?
Info
  • CH<x> specifies an analog input channel as the pulse-width trigger source.
  • DCH<x>_D<x> specifies an digital input channel as the pulse-width trigger source. The supported digital channel value is 1. The supported digital bit values are 0 to 15.

when property

Return the TRIGger:A:PULSEWidth:WHEn command.

Description
  • This command specifies to trigger when a pulse is detected with a width (duration) that is less than, greater than, equal to, or unequal to a specified value (set using TRIGGER:A:PULSEWIDTH:LOWLIMIT), OR whose width falls outside of or within a specified range of two values (set using TRIGGER:A:PULSEWIDTH:LOWLIMIT and TRIGGER:A:PULSEWIDTH:HIGHLIMIT).
Usage
  • Using the .query() method will send the TRIGger:A:PULSEWidth:WHEn? query.
  • Using the .verify(value) method will send the TRIGger:A:PULSEWidth:WHEn? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:PULSEWidth:WHEn value command.
SCPI Syntax
- TRIGger:A:PULSEWidth:WHEn {LESSthan|MOREthan|EQual|UNEQual|WIThin|OUTside}
- TRIGger:A:PULSEWidth:WHEn?
Info
  • LESSthan causes a trigger when a pulse is detected with a width less than the time set by the TRIGGER:A:PULSEWIDTH:LOWLIMIT command.
  • MOREthan causes a trigger when a pulse is detected with a width greater than the time set by the TRIGGER:A:PULSEWIDTH:LOWLIMIT command.
  • EQual causes a trigger when a pulse is detected with a width equal to the time period specified in TRIGGER:A:PULSEWIDTH:LOWLIMIT within a ±5% tolerance.
  • UNEQual causes a trigger when a pulse is detected with a width greater than or less than (but not equal) the time period specified in TRIGGER:A:PULSEWIDTH:LOWLIMIT within a ±5% tolerance.
  • WIThin causes a trigger when a pulse is detected that is within a range set by two values.
  • OUTside causes a trigger when a pulse is detected that is outside of a range set by two values.

TriggerAPulsewidthHighlimit

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:PULSEWidth:HIGHLimit command.

Description
  • This command specifies the upper limit to use, in seconds, when triggering on detection of a pulse whose duration is inside or outside a range of two values. (Use TRIGGER:A:PULSEWIDTH:LOWLIMIT to specify the lower value of the range.)
Usage
  • Using the .query() method will send the TRIGger:A:PULSEWidth:HIGHLimit? query.
  • Using the .verify(value) method will send the TRIGger:A:PULSEWidth:HIGHLimit? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:PULSEWidth:HIGHLimit value command.
SCPI Syntax
- TRIGger:A:PULSEWidth:HIGHLimit <NR3>
- TRIGger:A:PULSEWidth:HIGHLimit?
Info
  • <NR3> is a floating point number that represents the higher value of the range.

TriggerAPulsewidthLowlimit

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:PULSEWidth:LOWLimit command.

Description
  • This command specifies the lower limit to use, in seconds, when triggering on detection of a pulse whose duration is inside or outside a range of two values. (Use TRIGGER:A:PULSEWIDTH:HIGHLIMIT to specify the upper limit of the range.) This command also specifies the single limit to use, in seconds, when triggering on detection of a pulse whose duration is less than, greater than, equal to, or not equal to this time limit.
Usage
  • Using the .query() method will send the TRIGger:A:PULSEWidth:LOWLimit? query.
  • Using the .verify(value) method will send the TRIGger:A:PULSEWidth:LOWLimit? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:PULSEWidth:LOWLimit value command.
SCPI Syntax
- TRIGger:A:PULSEWidth:LOWLimit <NR3>
- TRIGger:A:PULSEWidth:LOWLimit?
Info
  • <NR3> is a floating point number that represents the lower value of the range.

TriggerAPulsewidthPolarity

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:PULSEWidth:POLarity command.

Description
  • This command specifies the polarity for a pulse width trigger.
Usage
  • Using the .query() method will send the TRIGger:A:PULSEWidth:POLarity? query.
  • Using the .verify(value) method will send the TRIGger:A:PULSEWidth:POLarity? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:PULSEWidth:POLarity value command.
SCPI Syntax
- TRIGger:A:PULSEWidth:POLarity {NEGative|POSitive}
- TRIGger:A:PULSEWidth:POLarity?
Info
  • NEGative specifies a negative pulse.
  • POSitive specifies a positive pulse.

TriggerAPulsewidthSource

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:PULSEWidth:SOUrce command.

Description
  • This command specifies the source waveform for a pulse width trigger.
Usage
  • Using the .query() method will send the TRIGger:A:PULSEWidth:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:PULSEWidth:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:PULSEWidth:SOUrce value command.
SCPI Syntax
- TRIGger:A:PULSEWidth:SOUrce {CH<x>|DCH<x>_D<x>}
- TRIGger:A:PULSEWidth:SOUrce?
Info
  • CH<x> specifies an analog input channel as the pulse-width trigger source.
  • DCH<x>_D<x> specifies an digital input channel as the pulse-width trigger source. The supported digital channel value is 1. The supported digital bit values are 0 to 15.

TriggerAPulsewidthWhen

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:PULSEWidth:WHEn command.

Description
  • This command specifies to trigger when a pulse is detected with a width (duration) that is less than, greater than, equal to, or unequal to a specified value (set using TRIGGER:A:PULSEWIDTH:LOWLIMIT), OR whose width falls outside of or within a specified range of two values (set using TRIGGER:A:PULSEWIDTH:LOWLIMIT and TRIGGER:A:PULSEWIDTH:HIGHLIMIT).
Usage
  • Using the .query() method will send the TRIGger:A:PULSEWidth:WHEn? query.
  • Using the .verify(value) method will send the TRIGger:A:PULSEWidth:WHEn? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:PULSEWidth:WHEn value command.
SCPI Syntax
- TRIGger:A:PULSEWidth:WHEn {LESSthan|MOREthan|EQual|UNEQual|WIThin|OUTside}
- TRIGger:A:PULSEWidth:WHEn?
Info
  • LESSthan causes a trigger when a pulse is detected with a width less than the time set by the TRIGGER:A:PULSEWIDTH:LOWLIMIT command.
  • MOREthan causes a trigger when a pulse is detected with a width greater than the time set by the TRIGGER:A:PULSEWIDTH:LOWLIMIT command.
  • EQual causes a trigger when a pulse is detected with a width equal to the time period specified in TRIGGER:A:PULSEWIDTH:LOWLIMIT within a ±5% tolerance.
  • UNEQual causes a trigger when a pulse is detected with a width greater than or less than (but not equal) the time period specified in TRIGGER:A:PULSEWIDTH:LOWLIMIT within a ±5% tolerance.
  • WIThin causes a trigger when a pulse is detected that is within a range set by two values.
  • OUTside causes a trigger when a pulse is detected that is outside of a range set by two values.

TriggerARunt

Bases: SCPICmdRead

The TRIGger:A:RUNT command tree.

Usage
  • Using the .query() method will send the TRIGger:A:RUNT? query.
  • Using the .verify(value) method will send the TRIGger:A:RUNT? query and raise an AssertionError if the returned value does not match value.
Properties
  • .polarity: The TRIGger:A:RUNT:POLarity command.
  • .source: The TRIGger:A:RUNT:SOUrce command.
  • .when: The TRIGger:A:RUNT:WHEn command.
  • .width: The TRIGger:A:RUNT:WIDth command.

polarity property

Return the TRIGger:A:RUNT:POLarity command.

Description
  • This command specifies the polarity for the runt trigger.
Usage
  • Using the .query() method will send the TRIGger:A:RUNT:POLarity? query.
  • Using the .verify(value) method will send the TRIGger:A:RUNT:POLarity? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RUNT:POLarity value command.
SCPI Syntax
- TRIGger:A:RUNT:POLarity {EITher|NEGative|POSitive}
- TRIGger:A:RUNT:POLarity?
Info
  • POSitive indicates that the rising edge crosses the low threshold and the falling edge recrosses the low threshold without either edge ever crossing the high threshold.
  • NEGative indicates that the falling edge crosses the high threshold and the rising edge recrosses the high threshold without either edge ever crossing the low threshold.
  • EITher triggers on a runt of either polarity.

source property

Return the TRIGger:A:RUNT:SOUrce command.

Description
  • This command specifies the source waveform for the runt trigger.
Usage
  • Using the .query() method will send the TRIGger:A:RUNT:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:RUNT:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RUNT:SOUrce value command.
SCPI Syntax
- TRIGger:A:RUNT:SOUrce {CH<x>}
- TRIGger:A:RUNT:SOUrce?
Info
  • CH<x> specifies the analog channel number to use as the source waveform for the runt trigger. To specify the threshold levels when using CH as the source, use TRIGGER:A:LOWERTHRESHOLD:CHX and TRIGGER:A:UPPERTHRESHOLD:CHX.

when property

Return the TRIGger:A:RUNT:WHEn command.

Description
  • This command specifies the type of pulse width the trigger checks for when it detects a runt.
Usage
  • Using the .query() method will send the TRIGger:A:RUNT:WHEn? query.
  • Using the .verify(value) method will send the TRIGger:A:RUNT:WHEn? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RUNT:WHEn value command.
SCPI Syntax
- TRIGger:A:RUNT:WHEn {LESSthan|MOREthan|EQual|UNEQual|OCCURS}
- TRIGger:A:RUNT:WHEn?
Info
  • OCCURS sets the instrument to trigger if a runt signal of any detectable width occurs.
  • LESSthan sets the instrument to trigger if the a runt pulse is detected with width less than the time set by the TRIGGER:A:RUNT:WIDTH command.
  • MOREthan sets the instrument to trigger if the a runt pulse is detected with width greater than the time set by the TRIGGER:A:RUNT:WIDTH command.
  • EQual sets the instrument to trigger if a runt pulse is detected with width equal to the time period specified in TRIGGER:A:RUNT:WIDTH within a ±5% tolerance.
  • UNEQual sets the instrument to trigger if a runt pulse is detected with width greater than or less than (but not equal to) the time period specified in TRIGGER:A:RUNT:WIDTH within a ±5% tolerance.

width property

Return the TRIGger:A:RUNT:WIDth command.

Description
  • This command specifies the width, in seconds, for a runt trigger.
Usage
  • Using the .query() method will send the TRIGger:A:RUNT:WIDth? query.
  • Using the .verify(value) method will send the TRIGger:A:RUNT:WIDth? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RUNT:WIDth value command.
SCPI Syntax
- TRIGger:A:RUNT:WIDth <NR3>
- TRIGger:A:RUNT:WIDth?
Info
  • <NR3> is a floating point number that specifies the minimum width, in seconds.

TriggerARuntPolarity

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:RUNT:POLarity command.

Description
  • This command specifies the polarity for the runt trigger.
Usage
  • Using the .query() method will send the TRIGger:A:RUNT:POLarity? query.
  • Using the .verify(value) method will send the TRIGger:A:RUNT:POLarity? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RUNT:POLarity value command.
SCPI Syntax
- TRIGger:A:RUNT:POLarity {EITher|NEGative|POSitive}
- TRIGger:A:RUNT:POLarity?
Info
  • POSitive indicates that the rising edge crosses the low threshold and the falling edge recrosses the low threshold without either edge ever crossing the high threshold.
  • NEGative indicates that the falling edge crosses the high threshold and the rising edge recrosses the high threshold without either edge ever crossing the low threshold.
  • EITher triggers on a runt of either polarity.

TriggerARuntSource

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:RUNT:SOUrce command.

Description
  • This command specifies the source waveform for the runt trigger.
Usage
  • Using the .query() method will send the TRIGger:A:RUNT:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:RUNT:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RUNT:SOUrce value command.
SCPI Syntax
- TRIGger:A:RUNT:SOUrce {CH<x>}
- TRIGger:A:RUNT:SOUrce?
Info
  • CH<x> specifies the analog channel number to use as the source waveform for the runt trigger. To specify the threshold levels when using CH as the source, use TRIGGER:A:LOWERTHRESHOLD:CHX and TRIGGER:A:UPPERTHRESHOLD:CHX.

TriggerARuntWhen

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:RUNT:WHEn command.

Description
  • This command specifies the type of pulse width the trigger checks for when it detects a runt.
Usage
  • Using the .query() method will send the TRIGger:A:RUNT:WHEn? query.
  • Using the .verify(value) method will send the TRIGger:A:RUNT:WHEn? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RUNT:WHEn value command.
SCPI Syntax
- TRIGger:A:RUNT:WHEn {LESSthan|MOREthan|EQual|UNEQual|OCCURS}
- TRIGger:A:RUNT:WHEn?
Info
  • OCCURS sets the instrument to trigger if a runt signal of any detectable width occurs.
  • LESSthan sets the instrument to trigger if the a runt pulse is detected with width less than the time set by the TRIGGER:A:RUNT:WIDTH command.
  • MOREthan sets the instrument to trigger if the a runt pulse is detected with width greater than the time set by the TRIGGER:A:RUNT:WIDTH command.
  • EQual sets the instrument to trigger if a runt pulse is detected with width equal to the time period specified in TRIGGER:A:RUNT:WIDTH within a ±5% tolerance.
  • UNEQual sets the instrument to trigger if a runt pulse is detected with width greater than or less than (but not equal to) the time period specified in TRIGGER:A:RUNT:WIDTH within a ±5% tolerance.

TriggerARuntWidth

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:RUNT:WIDth command.

Description
  • This command specifies the width, in seconds, for a runt trigger.
Usage
  • Using the .query() method will send the TRIGger:A:RUNT:WIDth? query.
  • Using the .verify(value) method will send the TRIGger:A:RUNT:WIDth? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:RUNT:WIDth value command.
SCPI Syntax
- TRIGger:A:RUNT:WIDth <NR3>
- TRIGger:A:RUNT:WIDth?
Info
  • <NR3> is a floating point number that specifies the minimum width, in seconds.

TriggerASethold

Bases: SCPICmdRead

The TRIGger:A:SETHold command tree.

Usage
  • Using the .query() method will send the TRIGger:A:SETHold? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold? query and raise an AssertionError if the returned value does not match value.
Properties
  • .clock: The TRIGger:A:SETHold:CLOCk command tree.
  • .holdtime: The TRIGger:A:SETHold:HOLDTime command.
  • .settime: The TRIGger:A:SETHold:SETTime command.

clock property

Return the TRIGger:A:SETHold:CLOCk command tree.

Usage
  • Using the .query() method will send the TRIGger:A:SETHold:CLOCk? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:CLOCk? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .edge: The TRIGger:A:SETHold:CLOCk:EDGE command.
  • .source: The TRIGger:A:SETHold:CLOCk:SOUrce command.

holdtime property

Return the TRIGger:A:SETHold:HOLDTime command.

Description
  • This command specifies the hold time for setup and hold violation triggering. This command is equivalent to selecting Setup/Hold Setup from the Trig menu and then setting the desired Hold Time.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:HOLDTime? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:HOLDTime? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:HOLDTime value command.
SCPI Syntax
- TRIGger:A:SETHold:HOLDTime <NR3>
- TRIGger:A:SETHold:HOLDTime?
Info
  • <NR3> is a floating point number that specifies the hold time setting, in seconds. Positive values for hold time occur after the clock edge. Negative values occur before the clock edge.

settime property

Return the TRIGger:A:SETHold:SETTime command.

Description
  • This command specifies the setup time for setup and hold violation triggering. This command is equivalent to selecting Setup/Hold Setup from the Trig menu and then setting the desired Setup Time.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:SETTime? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:SETTime? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:SETTime value command.
SCPI Syntax
- TRIGger:A:SETHold:SETTime <NR3>
- TRIGger:A:SETHold:SETTime?
Info
  • <NR3> is a floating point number that specifies the setup time for setup and hold violation triggering.

TriggerASetholdClock

Bases: SCPICmdRead

The TRIGger:A:SETHold:CLOCk command tree.

Usage
  • Using the .query() method will send the TRIGger:A:SETHold:CLOCk? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:CLOCk? query and raise an AssertionError if the returned value does not match value.
Properties
  • .edge: The TRIGger:A:SETHold:CLOCk:EDGE command.
  • .source: The TRIGger:A:SETHold:CLOCk:SOUrce command.

edge property

Return the TRIGger:A:SETHold:CLOCk:EDGE command.

Description
  • This command specifies the clock edge polarity for setup and hold triggering.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:CLOCk:EDGE? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:CLOCk:EDGE? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:CLOCk:EDGE value command.
SCPI Syntax
- TRIGger:A:SETHold:CLOCk:EDGE {FALL|RISe}
- TRIGger:A:SETHold:CLOCk:EDGE?
Info
  • FALL specifies polarity as the clock falling edge.
  • RISe specifies polarity as the clock rising edge.

source property

Return the TRIGger:A:SETHold:CLOCk:SOUrce command.

Description
  • This command specifies the clock source for the setup and hold triggering. You cannot specify the same source for both clock and data.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:CLOCk:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:CLOCk:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:CLOCk:SOUrce value command.
SCPI Syntax
- TRIGger:A:SETHold:CLOCk:SOUrce {CH<x>|DCH<x>_D<x>}
- TRIGger:A:SETHold:CLOCk:SOUrce?
Info
  • CH<x> specifies the analog channel to use as the clock source waveform.
  • DCH<x>_D<x> specifies the digital channel to use as the clock source waveform. The supported digital channel value is 1. The supported digital bit values are 0 to 15.

TriggerASetholdClockEdge

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:SETHold:CLOCk:EDGE command.

Description
  • This command specifies the clock edge polarity for setup and hold triggering.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:CLOCk:EDGE? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:CLOCk:EDGE? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:CLOCk:EDGE value command.
SCPI Syntax
- TRIGger:A:SETHold:CLOCk:EDGE {FALL|RISe}
- TRIGger:A:SETHold:CLOCk:EDGE?
Info
  • FALL specifies polarity as the clock falling edge.
  • RISe specifies polarity as the clock rising edge.

TriggerASetholdClockSource

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:SETHold:CLOCk:SOUrce command.

Description
  • This command specifies the clock source for the setup and hold triggering. You cannot specify the same source for both clock and data.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:CLOCk:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:CLOCk:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:CLOCk:SOUrce value command.
SCPI Syntax
- TRIGger:A:SETHold:CLOCk:SOUrce {CH<x>|DCH<x>_D<x>}
- TRIGger:A:SETHold:CLOCk:SOUrce?
Info
  • CH<x> specifies the analog channel to use as the clock source waveform.
  • DCH<x>_D<x> specifies the digital channel to use as the clock source waveform. The supported digital channel value is 1. The supported digital bit values are 0 to 15.

TriggerASetholdHoldtime

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:SETHold:HOLDTime command.

Description
  • This command specifies the hold time for setup and hold violation triggering. This command is equivalent to selecting Setup/Hold Setup from the Trig menu and then setting the desired Hold Time.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:HOLDTime? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:HOLDTime? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:HOLDTime value command.
SCPI Syntax
- TRIGger:A:SETHold:HOLDTime <NR3>
- TRIGger:A:SETHold:HOLDTime?
Info
  • <NR3> is a floating point number that specifies the hold time setting, in seconds. Positive values for hold time occur after the clock edge. Negative values occur before the clock edge.

TriggerASetholdSettime

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:SETHold:SETTime command.

Description
  • This command specifies the setup time for setup and hold violation triggering. This command is equivalent to selecting Setup/Hold Setup from the Trig menu and then setting the desired Setup Time.
Usage
  • Using the .query() method will send the TRIGger:A:SETHold:SETTime? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHold:SETTime? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHold:SETTime value command.
SCPI Syntax
- TRIGger:A:SETHold:SETTime <NR3>
- TRIGger:A:SETHold:SETTime?
Info
  • <NR3> is a floating point number that specifies the setup time for setup and hold violation triggering.

TriggerASetholdlogicval

Bases: SCPICmdRead

The TRIGger:A:SETHOLDLOGICVAL command tree.

Usage
  • Using the .query() method will send the TRIGger:A:SETHOLDLOGICVAL? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHOLDLOGICVAL? query and raise an AssertionError if the returned value does not match value.
Properties
  • .dch: The TRIGger:A:SETHOLDLOGICVAL:DCH<x> command tree.

dch property

Return the TRIGger:A:SETHOLDLOGICVAL:DCH<x> command tree.

Usage
  • Using the .query() method will send the TRIGger:A:SETHOLDLOGICVAL:DCH<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHOLDLOGICVAL:DCH<x>? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .d: The TRIGger:A:SETHOLDLOGICVAL:DCH<x>_D<x> command.

TriggerASetholdlogicvalDchItem

Bases: ValidatedDynamicNumberCmd, SCPICmdRead

The TRIGger:A:SETHOLDLOGICVAL:DCH<x> command tree.

Usage
  • Using the .query() method will send the TRIGger:A:SETHOLDLOGICVAL:DCH<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHOLDLOGICVAL:DCH<x>? query and raise an AssertionError if the returned value does not match value.
Properties
  • .d: The TRIGger:A:SETHOLDLOGICVAL:DCH<x>_D<x> command.

d property

Return the TRIGger:A:SETHOLDLOGICVAL:DCH<x>_D<x> command.

Description
  • This command sets or queries the conditions used for generating an A logic pattern, with respect to the defined input pattern, and identifies the time that the selected pattern may be true and still generate the trigger.
Usage
  • Using the .query() method will send the TRIGger:A:SETHOLDLOGICVAL:DCH<x>_D<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHOLDLOGICVAL:DCH<x>_D<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHOLDLOGICVAL:DCH<x>_D<x> value command.
SCPI Syntax
- TRIGger:A:SETHOLDLOGICVAL:DCH<x>_D<x> {INCLude|DONTInclude}
- TRIGger:A:SETHOLDLOGICVAL:DCH<x>_D<x>?
Info
  • DCH<x>_D<x> specifies the digital channel to use as the clock source waveform. The supported digital channel value is 1. The supported digital bit values are 0 to 15.
  • INCLude specifies including the specified digital channel SETHOLD inputs.
  • DONTInclude specifies not including the specified digital channel SETHOLD inputs.

TriggerASetholdlogicvalDchItemDigitalBit

Bases: ValidatedDigitalBit, SCPICmdWrite, SCPICmdRead

The TRIGger:A:SETHOLDLOGICVAL:DCH<x>_D<x> command.

Description
  • This command sets or queries the conditions used for generating an A logic pattern, with respect to the defined input pattern, and identifies the time that the selected pattern may be true and still generate the trigger.
Usage
  • Using the .query() method will send the TRIGger:A:SETHOLDLOGICVAL:DCH<x>_D<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:SETHOLDLOGICVAL:DCH<x>_D<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:SETHOLDLOGICVAL:DCH<x>_D<x> value command.
SCPI Syntax
- TRIGger:A:SETHOLDLOGICVAL:DCH<x>_D<x> {INCLude|DONTInclude}
- TRIGger:A:SETHOLDLOGICVAL:DCH<x>_D<x>?
Info
  • DCH<x>_D<x> specifies the digital channel to use as the clock source waveform. The supported digital channel value is 1. The supported digital bit values are 0 to 15.
  • INCLude specifies including the specified digital channel SETHOLD inputs.
  • DONTInclude specifies not including the specified digital channel SETHOLD inputs.

TriggerATimeout

Bases: SCPICmdRead

The TRIGger:A:TIMEOut command tree.

Usage
  • Using the .query() method will send the TRIGger:A:TIMEOut? query.
  • Using the .verify(value) method will send the TRIGger:A:TIMEOut? query and raise an AssertionError if the returned value does not match value.
Properties
  • .polarity: The TRIGger:A:TIMEOut:POLarity command.
  • .source: The TRIGger:A:TIMEOut:SOUrce command.
  • .time: The TRIGger:A:TIMEOut:TIMe command.

polarity property

Return the TRIGger:A:TIMEOut:POLarity command.

Description
  • When triggering using the TIMEOut trigger type, this commands specifies the polarity to be used.
Usage
  • Using the .query() method will send the TRIGger:A:TIMEOut:POLarity? query.
  • Using the .verify(value) method will send the TRIGger:A:TIMEOut:POLarity? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:TIMEOut:POLarity value command.
SCPI Syntax
- TRIGger:A:TIMEOut:POLarity {STAYSHigh|STAYSLow|EITher}
- TRIGger:A:TIMEOut:POLarity?
Info
  • STAYSHigh . Trigger when the signal stays high during the timeout time specified by the command TRIGGER:A:TIMEOUT:TIME.
  • STAYSLow . Trigger when the signal stays low during the timeout time specified by the command TRIGGER:A:TIMEOUT:TIME.
  • EITher . Trigger when the signal is either high or low during the timeout time specified by the command TRIGGER:A:TIMEOUT:TIME.

source property

Return the TRIGger:A:TIMEOut:SOUrce command.

Description
  • When triggering using the TIMEOut trigger type, this command specifies the source. The available sources are live channels and digital channels. The default is channel 1. The timeout trigger type is selected using TRIGGER:A:TYPE TIMEOut.
Usage
  • Using the .query() method will send the TRIGger:A:TIMEOut:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:TIMEOut:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:TIMEOut:SOUrce value command.
SCPI Syntax
- TRIGger:A:TIMEOut:SOUrce {CH<x>|DCH<x>_D<x>}
- TRIGger:A:TIMEOut:SOUrce?
Info
  • CH<x> specifies an analog channel as the timeout trigger source.
  • DCH<x>_D<x> specifies a digital channel as the timeout trigger source. The supported digital channel value is 1. The supported digital bit values are 0 to 15.

time property

Return the TRIGger:A:TIMEOut:TIMe command.

Description
  • When triggering using the TIMEOut trigger type, this command specifies the timeout time, in seconds. This command is equivalent to selecting Timeout from the Trig menu and setting a value for Time Limit. The timeout trigger type is selected using TRIGGER:A:TYPE TIMEOut
Usage
  • Using the .query() method will send the TRIGger:A:TIMEOut:TIMe? query.
  • Using the .verify(value) method will send the TRIGger:A:TIMEOut:TIMe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:TIMEOut:TIMe value command.
SCPI Syntax
- TRIGger:A:TIMEOut:TIMe <NR3>
- TRIGger:A:TIMEOut:TIMe?
Info
  • <NR3> is a floating point number that specifies the timeout time, in seconds.

TriggerATimeoutPolarity

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:TIMEOut:POLarity command.

Description
  • When triggering using the TIMEOut trigger type, this commands specifies the polarity to be used.
Usage
  • Using the .query() method will send the TRIGger:A:TIMEOut:POLarity? query.
  • Using the .verify(value) method will send the TRIGger:A:TIMEOut:POLarity? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:TIMEOut:POLarity value command.
SCPI Syntax
- TRIGger:A:TIMEOut:POLarity {STAYSHigh|STAYSLow|EITher}
- TRIGger:A:TIMEOut:POLarity?
Info
  • STAYSHigh . Trigger when the signal stays high during the timeout time specified by the command TRIGGER:A:TIMEOUT:TIME.
  • STAYSLow . Trigger when the signal stays low during the timeout time specified by the command TRIGGER:A:TIMEOUT:TIME.
  • EITher . Trigger when the signal is either high or low during the timeout time specified by the command TRIGGER:A:TIMEOUT:TIME.

TriggerATimeoutSource

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:TIMEOut:SOUrce command.

Description
  • When triggering using the TIMEOut trigger type, this command specifies the source. The available sources are live channels and digital channels. The default is channel 1. The timeout trigger type is selected using TRIGGER:A:TYPE TIMEOut.
Usage
  • Using the .query() method will send the TRIGger:A:TIMEOut:SOUrce? query.
  • Using the .verify(value) method will send the TRIGger:A:TIMEOut:SOUrce? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:TIMEOut:SOUrce value command.
SCPI Syntax
- TRIGger:A:TIMEOut:SOUrce {CH<x>|DCH<x>_D<x>}
- TRIGger:A:TIMEOut:SOUrce?
Info
  • CH<x> specifies an analog channel as the timeout trigger source.
  • DCH<x>_D<x> specifies a digital channel as the timeout trigger source. The supported digital channel value is 1. The supported digital bit values are 0 to 15.

TriggerATimeoutTime

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:TIMEOut:TIMe command.

Description
  • When triggering using the TIMEOut trigger type, this command specifies the timeout time, in seconds. This command is equivalent to selecting Timeout from the Trig menu and setting a value for Time Limit. The timeout trigger type is selected using TRIGGER:A:TYPE TIMEOut
Usage
  • Using the .query() method will send the TRIGger:A:TIMEOut:TIMe? query.
  • Using the .verify(value) method will send the TRIGger:A:TIMEOut:TIMe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:TIMEOut:TIMe value command.
SCPI Syntax
- TRIGger:A:TIMEOut:TIMe <NR3>
- TRIGger:A:TIMEOut:TIMe?
Info
  • <NR3> is a floating point number that specifies the timeout time, in seconds.

TriggerAType

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:A:TYPe command.

Description
  • This command sets or queries the type of A trigger.
Usage
  • Using the .query() method will send the TRIGger:A:TYPe? query.
  • Using the .verify(value) method will send the TRIGger:A:TYPe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:TYPe value command.
SCPI Syntax
- TRIGger:A:TYPe {EDGE|WIDth|RISE|FALL|TIMEOut|RUNt|LOGIc|SETHold|BUS}
- TRIGger:A:TYPe?
Info
  • EDGE is a normal trigger. A trigger event occurs when a signal passes through a specified voltage level in a specified direction and is controlled by the TRIGger:A:EDGE commands.
  • WIDth specifies that the trigger occurs when a pulse with a specified width is found.
  • RISE specifies that the trigger occurs when a pulse with a specified rise is found.
  • FALL specifies that the trigger occurs when a pulse with a specified fall is found.
  • TIMEOut specifies that a trigger occurs when a pulse with the specified timeout is found.
  • RUNt specifies that a trigger occurs when a pulse with the specified parameters is found.
  • LOGIc specifies that a trigger occurs when specified conditions are met and is controlled by the TRIGger:A:LOGIc commands.
  • SETHold specifies that a trigger occurs when a signal is found that meets the setup and hold parameters.
  • BUS specifies that a trigger occurs when a signal is found that meets the specified bus setup parameters.

TriggerAUpperthreshold

Bases: SCPICmdRead

The TRIGger:A:UPPerthreshold command tree.

Usage
  • Using the .query() method will send the TRIGger:A:UPPerthreshold? query.
  • Using the .verify(value) method will send the TRIGger:A:UPPerthreshold? query and raise an AssertionError if the returned value does not match value.
Properties
  • .ch: The TRIGger:A:UPPerthreshold:CH<x> command.

ch property

Return the TRIGger:A:UPPerthreshold:CH<x> command.

Description
  • This command sets or queries the specified channel upper trigger level. The CH range is 1 to 4 and depends on the number of analog channels on your instrument.
Usage
  • Using the .query() method will send the TRIGger:A:UPPerthreshold:CH<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:UPPerthreshold:CH<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:UPPerthreshold:CH<x> value command.
SCPI Syntax
- TRIGger:A:UPPerthreshold:CH<x> <NR3>
- TRIGger:A:UPPerthreshold:CH<x>?
Info
  • <NR3> specifies the trigger level in user units (usually volts).

TriggerAUpperthresholdChannel

Bases: ValidatedChannel, SCPICmdWrite, SCPICmdRead

The TRIGger:A:UPPerthreshold:CH<x> command.

Description
  • This command sets or queries the specified channel upper trigger level. The CH range is 1 to 4 and depends on the number of analog channels on your instrument.
Usage
  • Using the .query() method will send the TRIGger:A:UPPerthreshold:CH<x>? query.
  • Using the .verify(value) method will send the TRIGger:A:UPPerthreshold:CH<x>? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:A:UPPerthreshold:CH<x> value command.
SCPI Syntax
- TRIGger:A:UPPerthreshold:CH<x> <NR3>
- TRIGger:A:UPPerthreshold:CH<x>?
Info
  • <NR3> specifies the trigger level in user units (usually volts).

TriggerAuxlevel

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:AUXLevel command.

Description
  • This command sets or queries the Auxiliary Input voltage level to use for an edge trigger.
Usage
  • Using the .query() method will send the TRIGger:AUXLevel? query.
  • Using the .verify(value) method will send the TRIGger:AUXLevel? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:AUXLevel value command.
SCPI Syntax
- TRIGger:AUXLevel {<NR3>|ECL|TTL}
- TRIGger:AUXLevel?
Info
  • <NR3> is trigger level in Volts.
  • ECL sets trigger level to -1.3 Volts.
  • TTL sets trigger level to 1.4 Volts.

TriggerHysteresis

Bases: SCPICmdRead

The TRIGger:HYSTeresis command tree.

Usage
  • Using the .query() method will send the TRIGger:HYSTeresis? query.
  • Using the .verify(value) method will send the TRIGger:HYSTeresis? query and raise an AssertionError if the returned value does not match value.
Properties
  • .user: The TRIGger:HYSTeresis:USER command tree.

user property

Return the TRIGger:HYSTeresis:USER command tree.

Usage
  • Using the .query() method will send the TRIGger:HYSTeresis:USER? query.
  • Using the .verify(value) method will send the TRIGger:HYSTeresis:USER? query and raise an AssertionError if the returned value does not match value.
Sub-properties
  • .state: The TRIGger:HYSTeresis:USER:STATe command.
  • .value: The TRIGger:HYSTeresis:USER:VALue command.

TriggerHysteresisUser

Bases: SCPICmdRead

The TRIGger:HYSTeresis:USER command tree.

Usage
  • Using the .query() method will send the TRIGger:HYSTeresis:USER? query.
  • Using the .verify(value) method will send the TRIGger:HYSTeresis:USER? query and raise an AssertionError if the returned value does not match value.
Properties
  • .state: The TRIGger:HYSTeresis:USER:STATe command.
  • .value: The TRIGger:HYSTeresis:USER:VALue command.

state property

Return the TRIGger:HYSTeresis:USER:STATe command.

Description
  • This command enables or disables user-defined trigger hysteresis.
Usage
  • Using the .query() method will send the TRIGger:HYSTeresis:USER:STATe? query.
  • Using the .verify(value) method will send the TRIGger:HYSTeresis:USER:STATe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:HYSTeresis:USER:STATe value command.
SCPI Syntax
- TRIGger:HYSTeresis:USER:STATe {ON|OFF|1|0}
- TRIGger:HYSTeresis:USER:STATe?
Info
  • ON enables user-defined trigger hysteresis.
  • OFF disables user-defined trigger hysteresis.
  • 1 enables user-defined trigger hysteresis.
  • 0 disables user-defined trigger hysteresis.

value property

Return the TRIGger:HYSTeresis:USER:VALue command.

Description
  • This command sets or returns the height of the user-defined trigger hysteresis zone in volts.
Usage
  • Using the .query() method will send the TRIGger:HYSTeresis:USER:VALue? query.
  • Using the .verify(value) method will send the TRIGger:HYSTeresis:USER:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:HYSTeresis:USER:VALue value command.
SCPI Syntax
- TRIGger:HYSTeresis:USER:VALue <NR1>
- TRIGger:HYSTeresis:USER:VALue?
Info
  • <NR1> sets the height of the hysteresis zone in volts.

TriggerHysteresisUserState

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:HYSTeresis:USER:STATe command.

Description
  • This command enables or disables user-defined trigger hysteresis.
Usage
  • Using the .query() method will send the TRIGger:HYSTeresis:USER:STATe? query.
  • Using the .verify(value) method will send the TRIGger:HYSTeresis:USER:STATe? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:HYSTeresis:USER:STATe value command.
SCPI Syntax
- TRIGger:HYSTeresis:USER:STATe {ON|OFF|1|0}
- TRIGger:HYSTeresis:USER:STATe?
Info
  • ON enables user-defined trigger hysteresis.
  • OFF disables user-defined trigger hysteresis.
  • 1 enables user-defined trigger hysteresis.
  • 0 disables user-defined trigger hysteresis.

TriggerHysteresisUserValue

Bases: SCPICmdWrite, SCPICmdRead

The TRIGger:HYSTeresis:USER:VALue command.

Description
  • This command sets or returns the height of the user-defined trigger hysteresis zone in volts.
Usage
  • Using the .query() method will send the TRIGger:HYSTeresis:USER:VALue? query.
  • Using the .verify(value) method will send the TRIGger:HYSTeresis:USER:VALue? query and raise an AssertionError if the returned value does not match value.
  • Using the .write(value) method will send the TRIGger:HYSTeresis:USER:VALue value command.
SCPI Syntax
- TRIGger:HYSTeresis:USER:VALue <NR1>
- TRIGger:HYSTeresis:USER:VALue?
Info
  • <NR1> sets the height of the hysteresis zone in volts.

TriggerState

Bases: SCPICmdRead

The TRIGger:STATE command.

Description
  • This query-only command returns the current state of the triggering system.
Usage
  • Using the .query() method will send the TRIGger:STATE? query.
  • Using the .verify(value) method will send the TRIGger:STATE? query and raise an AssertionError if the returned value does not match value.
SCPI Syntax
- TRIGger:STATE?